Jiaxiang Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jiaxiang Wang has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Zhuoqing Yang
School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai, China
5 shared publications - Zhiyuan Hu
National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Shanghai Jiao Tong University, Shanghai, China
4 shared publications - Fengming Ye
Shanghai Jiao Tong University
3 shared publications - Chenyang Zhou
Shanghai Jiao Tong University
2 shared publications - Guifu Ding
National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Shanghai Jiao Tong University, Shanghai, China
2 shared publications Jianwei Hou
Shanghai Jiao Tong University
2 shared publications
Latest Publications
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 73 (11) , 6805-6814
Data-Driven Geometric Optimization of Size-Adaptive 3-D Multimodal Microscaffolds for Conformal Organoid Interfacing
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 73 (11) , 6805-6814
Data-Driven Geometric Optimization of Size-Adaptive 3-D Multimodal Microscaffolds for Conformal Organoid Interfacing
- 15 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. PP (1530437X) , 1
A Self-Folding 3D Bioelectronic Micro-Cage with Dealloyed Nanoporous Electrodes for Multimodal Monitoring of Cardiac Organoids
The geometric mismatch between rigid planar microelectrode arrays (MEAs) and soft three-dimensional (3D) organoids, alongside high electrode-tissue interface impedance, limits the fidelity of in vitro bioelectronic interrogations. We present a self-folding 3D bioelectronic micro-cage featuring dealloyed nanoporous electrodes to omnidirectionally encapsulate hiPSC-derived cardiac organoids for multimodal electrophysiological and thermal monitoring. Fabricated via a wafer-scale MEMS process, the planar SiO2/PI bilayer utilizes an intrinsic residual stress gradient to spontaneously self-assemble into a 3D conformal cage upon release. Crucially, a magnetron co-sputtered Au-Cu alloy was employed for the electrode layer. During the selective etching of the Cu sacrificial layer, simultaneous dealloying occurs, generating a high-surface-area nanoporous gold electrode structure. The scaffold achieved a predictable folding radius optimized for ~500 μm organoids. The optimized nanoporous gold electrodes exhibited significantly reduced electrochemical impedance (8.3kΩ at 1 kHz) and a massively enhanced charge storage capacity (53 mC/cm²) compared to standard bare gold. Integrated serpentine resistive sensors exhibited highly linear temperature-dependent resistance changes (R² = 0.9993), enabling on-device temperature monitoring during organoid assays. Functionally, the micro-cage recorded synchronized 3D extracellular field potentials from cardiac organoids and monitored electrophysiological responses to externally applied thermal perturbations and pharmacological agents, including Verapamil and Norepinephrine. These results demonstrate a promising MEMS-compatible platform for organoid-based electrophysiological recording, temperature monitoring, and proof-of-concept drug-response assessment.
- 15 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. PP (1530437X) , 1
A Self-Folding 3D Bioelectronic Micro-Cage with Dealloyed Nanoporous Electrodes for Multimodal Monitoring of Cardiac Organoids
The geometric mismatch between rigid planar microelectrode arrays (MEAs) and soft three-dimensional (3D) organoids, alongside high electrode-tissue interface impedance, limits the fidelity of in vitro bioelectronic interrogations. We present a self-folding 3D bioelectronic micro-cage featuring dealloyed nanoporous electrodes to omnidirectionally encapsulate hiPSC-derived cardiac organoids for multimodal electrophysiological and thermal monitoring. Fabricated via a wafer-scale MEMS process, the planar SiO2/PI bilayer utilizes an intrinsic residual stress gradient to spontaneously self-assemble into a 3D conformal cage upon release. Crucially, a magnetron co-sputtered Au-Cu alloy was employed for the electrode layer. During the selective etching of the Cu sacrificial layer, simultaneous dealloying occurs, generating a high-surface-area nanoporous gold electrode structure. The scaffold achieved a predictable folding radius optimized for ~500 μm organoids. The optimized nanoporous gold electrodes exhibited significantly reduced electrochemical impedance (8.3kΩ at 1 kHz) and a massively enhanced charge storage capacity (53 mC/cm²) compared to standard bare gold. Integrated serpentine resistive sensors exhibited highly linear temperature-dependent resistance changes (R² = 0.9993), enabling on-device temperature monitoring during organoid assays. Functionally, the micro-cage recorded synchronized 3D extracellular field potentials from cardiac organoids and monitored electrophysiological responses to externally applied thermal perturbations and pharmacological agents, including Verapamil and Norepinephrine. These results demonstrate a promising MEMS-compatible platform for organoid-based electrophysiological recording, temperature monitoring, and proof-of-concept drug-response assessment.
- 29 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 73 (3) , 1585-1595
A Thin-Film Strain Sensor With Near-Zero Temperature Interference and High Stability
Strain sensors are critical for dynamic strain monitoring in fields such as bridge safety assessment, but their accuracy in variable-temperature environments is hindered by temperature interference, a key issue that limits their reliability despite demands for high sensitivity and strong antitemperature capability. Here, we develop a resistive strain sensor based on a homogeneous composite thin-film, fabricated using microelectromechanical system (MEMS) technology. The design leverages defect-free, dense, and low-roughness microstructures, as well as the balanced electron scattering mechanisms in materials with positive/negative temperature coefficient of resistance (TCR) to clarify the microscopic nature of near-zero TCR. The resulting strain sensor exhibits a near-zero TCR of –3.5ppm/°C, strong antitemperature interference, and high long-term stability with a resistance drift rate (DR) of only 0.00019/h. It also shows good linearity and repeatability in strain response. Simulated bridge vibration tests confirm its rapid, consistent response to vibrations of varying amplitudes and ability to detect low-frequency microstrains, providing an effective solution for accurate long-term strain monitoring in variable-temperature scenarios.
- 29 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 73 (3) , 1585-1595
A Thin-Film Strain Sensor With Near-Zero Temperature Interference and High Stability
Strain sensors are critical for dynamic strain monitoring in fields such as bridge safety assessment, but their accuracy in variable-temperature environments is hindered by temperature interference, a key issue that limits their reliability despite demands for high sensitivity and strong antitemperature capability. Here, we develop a resistive strain sensor based on a homogeneous composite thin-film, fabricated using microelectromechanical system (MEMS) technology. The design leverages defect-free, dense, and low-roughness microstructures, as well as the balanced electron scattering mechanisms in materials with positive/negative temperature coefficient of resistance (TCR) to clarify the microscopic nature of near-zero TCR. The resulting strain sensor exhibits a near-zero TCR of –3.5ppm/°C, strong antitemperature interference, and high long-term stability with a resistance drift rate (DR) of only 0.00019/h. It also shows good linearity and repeatability in strain response. Simulated bridge vibration tests confirm its rapid, consistent response to vibrations of varying amplitudes and ability to detect low-frequency microstrains, providing an effective solution for accurate long-term strain monitoring in variable-temperature scenarios.
- 13 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (22) , 28129-28140
A Flexible and Dual-Channel Sensing System for Long-Term Nasal and Oral Respiration Simultaneously Monitoring
A flexible and dual-channel sensing system is proposed for monitoring nasal and oral respiration simultaneously during sleep. The system consists of a respiratory sensor and a signal processing circuit. The sensitive units of the respiratory sensor are composed of folding metal resistances which are deposited on flexible substrate by micro-electro-mechanical system technology, and the working principle is based on thermal resistance effect. The simulation demonstrates that there is a remarkable temperature difference in the sensitive units between inhalation and exhalation (10 °С and 19 °С for nasal and oral channel respectively), and the performance tests illustrate that the sensing system has superior sensitivity (9.4 mV and 19.6 mV for nasal and oral channel respectively), stability and anti-interference ability. Also, the system is proved to be able to identify and distinguish various kinds of respiratory diseases including hypopnea, mouth breathing, and apnea. Therefore, the proposed sensing system can serve as an effective method for health monitoring and early screening of respiratory diseases in the future.
- 13 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (22) , 28129-28140
A Flexible and Dual-Channel Sensing System for Long-Term Nasal and Oral Respiration Simultaneously Monitoring
A flexible and dual-channel sensing system is proposed for monitoring nasal and oral respiration simultaneously during sleep. The system consists of a respiratory sensor and a signal processing circuit. The sensitive units of the respiratory sensor are composed of folding metal resistances which are deposited on flexible substrate by micro-electro-mechanical system technology, and the working principle is based on thermal resistance effect. The simulation demonstrates that there is a remarkable temperature difference in the sensitive units between inhalation and exhalation (10 °С and 19 °С for nasal and oral channel respectively), and the performance tests illustrate that the sensing system has superior sensitivity (9.4 mV and 19.6 mV for nasal and oral channel respectively), stability and anti-interference ability. Also, the system is proved to be able to identify and distinguish various kinds of respiratory diseases including hypopnea, mouth breathing, and apnea. Therefore, the proposed sensing system can serve as an effective method for health monitoring and early screening of respiratory diseases in the future.
- Open Access
Automatic assembly of aero engine low pressure turbine shaft based on 3D vision measurement
In order to solve the problem of low automation of Aero-engine Turbine shaft assembly and the difficulty of non-contact high-precision measurement, a structured light binocular measurement technology for key components of aero-engine is proposed in this paper. Combined with three-dimensional point cloud data processing and assembly position matching algorithm, the high-precision measurement of shaft hole assembly posture in the process of turbine shaft docking is realized. Firstly, the screw thread curve on the bolt surface is segmented based on PCA projection and edge point cloud clustering, and Hough transform is used to model fit the three-dimensional thread curve. Then the preprocessed two-dimensional convex hull is constructed to segment the key hole location features, and the mounting surface and hole location obtained by segmentation are fitted based on RANSAC method. Finally, the geometric feature matching is used the evaluation index of turbine shaft assembly is established to optimize the pose. The final measurement accuracy of mounting surface matching is less than 0.05mm, and the measurement accuracy of mounting hole matching based on minimum ance optimization is less than 0.1 degree. The measurement algorithm is implemented on the automatic assembly test-bed of a certain type of aero-engine low-pressure turbine rotor. In the narrow installation space, the assembly process of the turbine shaft assembly, such as the automatic alignment and docking of the shaft hole, the automatic heating and temperature measurement of the installation seam, and the automatic tightening of the two guns, are realized in the narrow installation space Guidance, real-time inspection and assembly result evaluation.
Open AccessAutomatic assembly of aero engine low pressure turbine shaft based on 3D vision measurement
In order to solve the problem of low automation of Aero-engine Turbine shaft assembly and the difficulty of non-contact high-precision measurement, a structured light binocular measurement technology for key components of aero-engine is proposed in this paper. Combined with three-dimensional point cloud data processing and assembly position matching algorithm, the high-precision measurement of shaft hole assembly posture in the process of turbine shaft docking is realized. Firstly, the screw thread curve on the bolt surface is segmented based on PCA projection and edge point cloud clustering, and Hough transform is used to model fit the three-dimensional thread curve. Then the preprocessed two-dimensional convex hull is constructed to segment the key hole location features, and the mounting surface and hole location obtained by segmentation are fitted based on RANSAC method. Finally, the geometric feature matching is used the evaluation index of turbine shaft assembly is established to optimize the pose. The final measurement accuracy of mounting surface matching is less than 0.05mm, and the measurement accuracy of mounting hole matching based on minimum ance optimization is less than 0.1 degree. The measurement algorithm is implemented on the automatic assembly test-bed of a certain type of aero-engine low-pressure turbine rotor. In the narrow installation space, the assembly process of the turbine shaft assembly, such as the automatic alignment and docking of the shaft hole, the automatic heating and temperature measurement of the installation seam, and the automatic tightening of the two guns, are realized in the narrow installation space Guidance, real-time inspection and assembly result evaluation.