Ya-Hui Lin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ya-Hui Lin has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Bing-Ru Peng
Department of Medical Imaging and Radiological Sciences, Central Taiwan University of Science and Technology, Taichung 406, Taiwan
2 shared publications - Ke-Lin Chen
Department of Radiology, The First Affiliated Hospital of Ningbo University, Ningbo 315012, China
2 shared publications - Lung-Kwang Pan
Department of Medical Imaging and Radiological Sciences, Central Taiwan University of Science and Technology, Takun, Taichung 406, Taiwan
2 shared publications - Tsung-Han Lin
Department of Medical Imaging and Radiological Sciences, Central Taiwan University of Science and Technology, Takun, Taichung 406, Taiwan, ROC
2 shared publications Bing-Ru Peng
Department of Medical Imaging and Radiological Sciences, Central Taiwan University of Science and Technology, Takun, Taichung 406
1 shared publication- Chih-Sheng Lin
The Affiliated BenQ Hospital of Nanjing Medical University
1 shared publication
Latest Publications
- 17 February 2026
- Published by SAGE Publications in Technology and Health Care
- Vol. 34 (2) , 208-221
Valproic acid physiological pharmacokinetics simulation for epilepsy patients via a refined seven-compartmental model: A pilot study
This study simulated valproic acid (VPA) physiological pharmacokinetics for epilepsy patients via a refined seven-compartmental model. The seven compartments were defined as oral, GI Tract, liver, whole body (WB), cerebrospinal fluid (CSF), kidney, and bladder. A first-order system of seven differential equations was defined according to this specific model and solved by a self-developed program run in MATLAB to evaluate the VPA time-dependent change among compartments. Each compartment's preset dissolving half-life (in hours) was as follows: oral 0.05, GI Tract 0.10, liver 0.5, WB 2.2, CSF 0.8, kidney 1.2, and bladder 0.5, respectively. The derived results were reorganized according to various presets of dissolving half-lives of the liver, WB, CSF, or kidney to analyze the VPA time-dependent changes under various scenarios. Either the liver or WB was the dominant compartment in this model, which mainly controlled the VPA changes. In contrast, others compartments followed the principle of secular equilibrium in the chain decay of radioactive nuclides. Accordingly, the VPA degradation changes in WB (“mother” compartment) mainly affected the VPA changes in other (“daughter”) compartments. Thus, the predicted VPA degradation in CSF, kidney, or bladder was always longer than in WB despite its dissolving half-life changes. The predicted results of VPA changes in various compartments were also compared with other studies, and a reasonable agreement was reached on whether the dissolving half-life of the liver or WB ranged from the original 0.2/2.2 to 1.4/0.9 h. The programable capability of this self-developed program allows one to easily modify the primary preset to comply with findings from other studies and has great potential in similar applications.
- 17 February 2026
- Published by SAGE Publications in Technology and Health Care
- Vol. 34 (2) , 208-221
Valproic acid physiological pharmacokinetics simulation for epilepsy patients via a refined seven-compartmental model: A pilot study
This study simulated valproic acid (VPA) physiological pharmacokinetics for epilepsy patients via a refined seven-compartmental model. The seven compartments were defined as oral, GI Tract, liver, whole body (WB), cerebrospinal fluid (CSF), kidney, and bladder. A first-order system of seven differential equations was defined according to this specific model and solved by a self-developed program run in MATLAB to evaluate the VPA time-dependent change among compartments. Each compartment's preset dissolving half-life (in hours) was as follows: oral 0.05, GI Tract 0.10, liver 0.5, WB 2.2, CSF 0.8, kidney 1.2, and bladder 0.5, respectively. The derived results were reorganized according to various presets of dissolving half-lives of the liver, WB, CSF, or kidney to analyze the VPA time-dependent changes under various scenarios. Either the liver or WB was the dominant compartment in this model, which mainly controlled the VPA changes. In contrast, others compartments followed the principle of secular equilibrium in the chain decay of radioactive nuclides. Accordingly, the VPA degradation changes in WB (“mother” compartment) mainly affected the VPA changes in other (“daughter”) compartments. Thus, the predicted VPA degradation in CSF, kidney, or bladder was always longer than in WB despite its dissolving half-life changes. The predicted results of VPA changes in various compartments were also compared with other studies, and a reasonable agreement was reached on whether the dissolving half-life of the liver or WB ranged from the original 0.2/2.2 to 1.4/0.9 h. The programable capability of this self-developed program allows one to easily modify the primary preset to comply with findings from other studies and has great potential in similar applications.
- 24 August 2024
- Published by World Scientific Pub Co Pte Ltd in Journal of Mechanics in Medicine and Biology
- Vol. 24 (08)
ADVANCED TECHNIQUE AND MULTI-W-SHAPED SLIT GAUGE FOR QUANTIFYING SPECT SPATIAL RESOLUTION OF GAMMA CAMERA SCAN DATA: AN ENHANCED STUDY
The advanced technique comprising an enhanced multi-W-shaped gauge and Taguchi-based analytical program of gamma camera (GC) spatial resolution optimization was proposed and successfully applied to the routine diagnosis of nuclear examination. The indigenous gauge was revised from a V-shaped gauge for computer tomography (CT) scanning. The multi-W-shaped slit had a gradually narrowing gap between two adjacent V-slits; once the gap was beyond the GC recognizable limit, the acquired imaging blurred, and the discrimination between V-slits was lost. The five factors of GC data collecting were assigned as A (detector to target distance), B (total counts), C (zoom of ROI), D (matrix size), and E (energy width). Taguchi’s orthogonal array ([ ]) of factor combinations was adopted to arrange them into 18 groups. The reproducibility was ensured by the manual ranking of the acquired SPECT imaging quality by three seasoned radiology experts in three discrete periods. Next, Matlab and OriginPro software packages performed the SPECT analysis via the Poisson distribution program, identifying the peak center and FWHM of peaks of interest in SPECT imaging to quantify the spatial resolution and calculate the minimum detectable difference (MDD). The smallest MDD of 6.21[ ]mm revealed the optimal combination of factors for GC data collecting: A1 (DTD 5[ ]cm), B3 (TC 225), C3 (Zm 1.0), D1 (MS [ ]), and E2 (EW 10%). The conventional preset and group 7 (with the highest signal-to-noise ratio) had MDD values of 8.19[ ]mm and 7.62[ ]mm.
- 24 August 2024
- Published by World Scientific Pub Co Pte Ltd in Journal of Mechanics in Medicine and Biology
- Vol. 24 (08)
ADVANCED TECHNIQUE AND MULTI-W-SHAPED SLIT GAUGE FOR QUANTIFYING SPECT SPATIAL RESOLUTION OF GAMMA CAMERA SCAN DATA: AN ENHANCED STUDY
The advanced technique comprising an enhanced multi-W-shaped gauge and Taguchi-based analytical program of gamma camera (GC) spatial resolution optimization was proposed and successfully applied to the routine diagnosis of nuclear examination. The indigenous gauge was revised from a V-shaped gauge for computer tomography (CT) scanning. The multi-W-shaped slit had a gradually narrowing gap between two adjacent V-slits; once the gap was beyond the GC recognizable limit, the acquired imaging blurred, and the discrimination between V-slits was lost. The five factors of GC data collecting were assigned as A (detector to target distance), B (total counts), C (zoom of ROI), D (matrix size), and E (energy width). Taguchi’s orthogonal array ([ ]) of factor combinations was adopted to arrange them into 18 groups. The reproducibility was ensured by the manual ranking of the acquired SPECT imaging quality by three seasoned radiology experts in three discrete periods. Next, Matlab and OriginPro software packages performed the SPECT analysis via the Poisson distribution program, identifying the peak center and FWHM of peaks of interest in SPECT imaging to quantify the spatial resolution and calculate the minimum detectable difference (MDD). The smallest MDD of 6.21[ ]mm revealed the optimal combination of factors for GC data collecting: A1 (DTD 5[ ]cm), B3 (TC 225), C3 (Zm 1.0), D1 (MS [ ]), and E2 (EW 10%). The conventional preset and group 7 (with the highest signal-to-noise ratio) had MDD values of 8.19[ ]mm and 7.62[ ]mm.
- Open Access
- 31 October 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (21) , 3354
Inverse Problem Algorithm-Based Time-Resolved Imaging of Head and Neck Computed Tomography Angiography Contrast Kinetics with Clinical Testification
This study mitigated the challenge of head and neck CT angiography by IPA-based time-resolved imaging of contrast kinetics. To this end, 627 cerebral hemorrhage patients with dizziness, brain aneurysm, stroke, or hemorrhagic stroke diagnosis were randomly categorized into three groups, namely, the original dataset (450), verification group (112), and in vivo testified group (65), in the Affiliated BenQ Hospital of Nanjing Medical University. In the first stage, seven risk factors were assigned: age, CTA tube voltage, body surface area, heart rate per minute, cardiac output blood per minute, the actual injected amount of contrast media, and CTA delayed trigger timing. The expectation value of the semi-empirical formula was the CTA number of the patient’s left artery (LA). Accordingly, 29 items of the first-order nonlinear equation were calculated via the inverse problem analysis (IPA) technique run in the STATISTICA 7.0 program, yielding a loss function and variance of 3.1837 and 0.8892, respectively. A dimensionless AT was proposed to imply the coincidence, with a lower AT indicating a smaller deviation between theoretical and practical values. The derived formula was confirmed for the verification group of 112 patients, reaching high coincidence, with average ATavg and standard deviation values of 3.57% and 3.06%, respectively. In the second stage, the formula was refined to find the optimal amount of contrast media for the CTA number of LA approaching 400. Finally, the above procedure was applied to head and neck CTA images of the third group of 65 patients, reaching an average CTA number of LA of 407.8 ± 16.2 and finding no significant fluctuations.
- 31 October 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (21) , 3354
Open AccessInverse Problem Algorithm-Based Time-Resolved Imaging of Head and Neck Computed Tomography Angiography Contrast Kinetics with Clinical Testification
This study mitigated the challenge of head and neck CT angiography by IPA-based time-resolved imaging of contrast kinetics. To this end, 627 cerebral hemorrhage patients with dizziness, brain aneurysm, stroke, or hemorrhagic stroke diagnosis were randomly categorized into three groups, namely, the original dataset (450), verification group (112), and in vivo testified group (65), in the Affiliated BenQ Hospital of Nanjing Medical University. In the first stage, seven risk factors were assigned: age, CTA tube voltage, body surface area, heart rate per minute, cardiac output blood per minute, the actual injected amount of contrast media, and CTA delayed trigger timing. The expectation value of the semi-empirical formula was the CTA number of the patient’s left artery (LA). Accordingly, 29 items of the first-order nonlinear equation were calculated via the inverse problem analysis (IPA) technique run in the STATISTICA 7.0 program, yielding a loss function and variance of 3.1837 and 0.8892, respectively. A dimensionless AT was proposed to imply the coincidence, with a lower AT indicating a smaller deviation between theoretical and practical values. The derived formula was confirmed for the verification group of 112 patients, reaching high coincidence, with average ATavg and standard deviation values of 3.57% and 3.06%, respectively. In the second stage, the formula was refined to find the optimal amount of contrast media for the CTA number of LA approaching 400. Finally, the above procedure was applied to head and neck CTA images of the third group of 65 patients, reaching an average CTA number of LA of 407.8 ± 16.2 and finding no significant fluctuations.