Ke-Lin Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ke-Lin Chen has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Lung-Kwang Pan
Department of Medical Imaging and Radiological Sciences, Central Taiwan University of Science and Technology, Takun, Taichung 406, Taiwan
3 shared publications - Bing-Ru Peng
Department of Medical Imaging and Radiological Sciences, Central Taiwan University of Science and Technology, Taichung 406, Taiwan
2 shared publications - Chih-Sheng Lin
The Affiliated BenQ Hospital of Nanjing Medical University
2 shared publications - Tsung-Han Lin
Department of Medical Imaging and Radiological Sciences, Central Taiwan University of Science and Technology, Takun, Taichung 406, Taiwan, ROC
2 shared publications - Ya-Hui Lin
Department of Medical Imaging and Radiological Sciences, Central Taiwan University of Science and Technology, Takun, Taichung 406
2 shared publications - Chih-Sheng Lin
Department of Radiology, BenQ Medical Center, Affiliated BenQ Hospital of the Nanjing Medical University, Nanjing 211166, Jiangsu, P. R. China
1 shared publication
Latest Publications
- Open Access
- 25 September 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (19) , 2126
Best-Corrected Visual Acuity Quantitative Prediction for Cataract Patients: AI-Assisted Clinical Diagnostics Facilitation via the Inverse Problem Algorithm
Objective: This study provided a quantitative prediction of best-corrected visual acuity (BCVA) for cataract patients using the inverse problem algorithm (IPA) technique earlier proposed by the authors. Methods: To this end, seven risk factors (age, BMI, MAP, IOP, HbA1c, LDL-C, and gender) were linked by a semi-empirical formula by normalizing each factor into a dimensionless range of −1.0 to +1.0. The adopted inverse problem algorithm (IPA) technique was run via a self-developed program in STATISTICA 7.0, featuring a 29-term nonlinear equation considering seven risk factors, cross-interaction between various pairs of factors, and one constant term [7 + (7 × 6)/2 + 1 = 29]. The IPA neglected quadratic, triple, or quadruple factors′ cross-interactions. This study used a dataset of 632 cataract patients to attain a reliable BCVA prediction with a variance of 0.929. A verification dataset of 160 patients with similar symptoms was used to verify this approach′s feasibility, reaching a good correlation with R2 = 0.909. Results: The verification group′s derived average AT (agreement) (9.12 ± 27.00%) indicated a slight deviation between the theoretical prediction and practical BCVA. The significant factors were age, body mass index (BMI), and intraocular pressure (IOP), whereas mean arterial pressure (MAP), hemoglobin A1c (HbA1c), low-density-lipoprotein cholesterol (LDL-C), and gender insignificantly contributed to BCVA. Conclusions: The proposed approach is instrumental in AI-assisted clinical diagnosis, yielding robust BCVA predictions for individual cataract patients based on their biological indices before the ophthalmological examination procedure.
- 25 September 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (19) , 2126
Open AccessBest-Corrected Visual Acuity Quantitative Prediction for Cataract Patients: AI-Assisted Clinical Diagnostics Facilitation via the Inverse Problem Algorithm
Objective: This study provided a quantitative prediction of best-corrected visual acuity (BCVA) for cataract patients using the inverse problem algorithm (IPA) technique earlier proposed by the authors. Methods: To this end, seven risk factors (age, BMI, MAP, IOP, HbA1c, LDL-C, and gender) were linked by a semi-empirical formula by normalizing each factor into a dimensionless range of −1.0 to +1.0. The adopted inverse problem algorithm (IPA) technique was run via a self-developed program in STATISTICA 7.0, featuring a 29-term nonlinear equation considering seven risk factors, cross-interaction between various pairs of factors, and one constant term [7 + (7 × 6)/2 + 1 = 29]. The IPA neglected quadratic, triple, or quadruple factors′ cross-interactions. This study used a dataset of 632 cataract patients to attain a reliable BCVA prediction with a variance of 0.929. A verification dataset of 160 patients with similar symptoms was used to verify this approach′s feasibility, reaching a good correlation with R2 = 0.909. Results: The verification group′s derived average AT (agreement) (9.12 ± 27.00%) indicated a slight deviation between the theoretical prediction and practical BCVA. The significant factors were age, body mass index (BMI), and intraocular pressure (IOP), whereas mean arterial pressure (MAP), hemoglobin A1c (HbA1c), low-density-lipoprotein cholesterol (LDL-C), and gender insignificantly contributed to BCVA. Conclusions: The proposed approach is instrumental in AI-assisted clinical diagnosis, yielding robust BCVA predictions for individual cataract patients based on their biological indices before the ophthalmological examination procedure.
- 24 August 2024
- Published by World Scientific Pub Co Pte Ltd in Journal of Mechanics in Medicine and Biology
- Vol. 24 (08)
ADVANCED TECHNIQUE AND MULTI-W-SHAPED SLIT GAUGE FOR QUANTIFYING SPECT SPATIAL RESOLUTION OF GAMMA CAMERA SCAN DATA: AN ENHANCED STUDY
The advanced technique comprising an enhanced multi-W-shaped gauge and Taguchi-based analytical program of gamma camera (GC) spatial resolution optimization was proposed and successfully applied to the routine diagnosis of nuclear examination. The indigenous gauge was revised from a V-shaped gauge for computer tomography (CT) scanning. The multi-W-shaped slit had a gradually narrowing gap between two adjacent V-slits; once the gap was beyond the GC recognizable limit, the acquired imaging blurred, and the discrimination between V-slits was lost. The five factors of GC data collecting were assigned as A (detector to target distance), B (total counts), C (zoom of ROI), D (matrix size), and E (energy width). Taguchi’s orthogonal array ([ ]) of factor combinations was adopted to arrange them into 18 groups. The reproducibility was ensured by the manual ranking of the acquired SPECT imaging quality by three seasoned radiology experts in three discrete periods. Next, Matlab and OriginPro software packages performed the SPECT analysis via the Poisson distribution program, identifying the peak center and FWHM of peaks of interest in SPECT imaging to quantify the spatial resolution and calculate the minimum detectable difference (MDD). The smallest MDD of 6.21[ ]mm revealed the optimal combination of factors for GC data collecting: A1 (DTD 5[ ]cm), B3 (TC 225), C3 (Zm 1.0), D1 (MS [ ]), and E2 (EW 10%). The conventional preset and group 7 (with the highest signal-to-noise ratio) had MDD values of 8.19[ ]mm and 7.62[ ]mm.
- 24 August 2024
- Published by World Scientific Pub Co Pte Ltd in Journal of Mechanics in Medicine and Biology
- Vol. 24 (08)
ADVANCED TECHNIQUE AND MULTI-W-SHAPED SLIT GAUGE FOR QUANTIFYING SPECT SPATIAL RESOLUTION OF GAMMA CAMERA SCAN DATA: AN ENHANCED STUDY
The advanced technique comprising an enhanced multi-W-shaped gauge and Taguchi-based analytical program of gamma camera (GC) spatial resolution optimization was proposed and successfully applied to the routine diagnosis of nuclear examination. The indigenous gauge was revised from a V-shaped gauge for computer tomography (CT) scanning. The multi-W-shaped slit had a gradually narrowing gap between two adjacent V-slits; once the gap was beyond the GC recognizable limit, the acquired imaging blurred, and the discrimination between V-slits was lost. The five factors of GC data collecting were assigned as A (detector to target distance), B (total counts), C (zoom of ROI), D (matrix size), and E (energy width). Taguchi’s orthogonal array ([ ]) of factor combinations was adopted to arrange them into 18 groups. The reproducibility was ensured by the manual ranking of the acquired SPECT imaging quality by three seasoned radiology experts in three discrete periods. Next, Matlab and OriginPro software packages performed the SPECT analysis via the Poisson distribution program, identifying the peak center and FWHM of peaks of interest in SPECT imaging to quantify the spatial resolution and calculate the minimum detectable difference (MDD). The smallest MDD of 6.21[ ]mm revealed the optimal combination of factors for GC data collecting: A1 (DTD 5[ ]cm), B3 (TC 225), C3 (Zm 1.0), D1 (MS [ ]), and E2 (EW 10%). The conventional preset and group 7 (with the highest signal-to-noise ratio) had MDD values of 8.19[ ]mm and 7.62[ ]mm.
- Open Access
- 31 October 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (21) , 3354
Inverse Problem Algorithm-Based Time-Resolved Imaging of Head and Neck Computed Tomography Angiography Contrast Kinetics with Clinical Testification
This study mitigated the challenge of head and neck CT angiography by IPA-based time-resolved imaging of contrast kinetics. To this end, 627 cerebral hemorrhage patients with dizziness, brain aneurysm, stroke, or hemorrhagic stroke diagnosis were randomly categorized into three groups, namely, the original dataset (450), verification group (112), and in vivo testified group (65), in the Affiliated BenQ Hospital of Nanjing Medical University. In the first stage, seven risk factors were assigned: age, CTA tube voltage, body surface area, heart rate per minute, cardiac output blood per minute, the actual injected amount of contrast media, and CTA delayed trigger timing. The expectation value of the semi-empirical formula was the CTA number of the patient’s left artery (LA). Accordingly, 29 items of the first-order nonlinear equation were calculated via the inverse problem analysis (IPA) technique run in the STATISTICA 7.0 program, yielding a loss function and variance of 3.1837 and 0.8892, respectively. A dimensionless AT was proposed to imply the coincidence, with a lower AT indicating a smaller deviation between theoretical and practical values. The derived formula was confirmed for the verification group of 112 patients, reaching high coincidence, with average ATavg and standard deviation values of 3.57% and 3.06%, respectively. In the second stage, the formula was refined to find the optimal amount of contrast media for the CTA number of LA approaching 400. Finally, the above procedure was applied to head and neck CTA images of the third group of 65 patients, reaching an average CTA number of LA of 407.8 ± 16.2 and finding no significant fluctuations.
- 31 October 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (21) , 3354
Open AccessInverse Problem Algorithm-Based Time-Resolved Imaging of Head and Neck Computed Tomography Angiography Contrast Kinetics with Clinical Testification
This study mitigated the challenge of head and neck CT angiography by IPA-based time-resolved imaging of contrast kinetics. To this end, 627 cerebral hemorrhage patients with dizziness, brain aneurysm, stroke, or hemorrhagic stroke diagnosis were randomly categorized into three groups, namely, the original dataset (450), verification group (112), and in vivo testified group (65), in the Affiliated BenQ Hospital of Nanjing Medical University. In the first stage, seven risk factors were assigned: age, CTA tube voltage, body surface area, heart rate per minute, cardiac output blood per minute, the actual injected amount of contrast media, and CTA delayed trigger timing. The expectation value of the semi-empirical formula was the CTA number of the patient’s left artery (LA). Accordingly, 29 items of the first-order nonlinear equation were calculated via the inverse problem analysis (IPA) technique run in the STATISTICA 7.0 program, yielding a loss function and variance of 3.1837 and 0.8892, respectively. A dimensionless AT was proposed to imply the coincidence, with a lower AT indicating a smaller deviation between theoretical and practical values. The derived formula was confirmed for the verification group of 112 patients, reaching high coincidence, with average ATavg and standard deviation values of 3.57% and 3.06%, respectively. In the second stage, the formula was refined to find the optimal amount of contrast media for the CTA number of LA approaching 400. Finally, the above procedure was applied to head and neck CTA images of the third group of 65 patients, reaching an average CTA number of LA of 407.8 ± 16.2 and finding no significant fluctuations.