IÇİrEm Çötert

İrEm Çötert

*This is an algorithmically generated author record based on publicly available information.

İrEm Çötert has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    In-Vitro Comparison of Screw Loosening, Fracture Strength and Failure Mode of Implant-Supported Hybrid-Abutment Crowns and Screwmentable Crowns Manufactured with Different Materials

    by İ Çötert, M Ulusoy, Ag Türk

    Background: Hybrid-abutment crowns and screwmentable crowns offer a fusion of the benefits from both screw and cement-retained restorations, potentially enhancing the overall performance of the restoration. Aim: This study aimed to evaluate the screw loosening and fracture strength of hybrid-abutment crowns and screwmentable crowns made with two different materials. Methods: Forty single-crown were made on titanium implants and divided into four groups ( n = 10) [SM-Ti: Screwmentable titanium-porcelain crowns on stock titanium abutment; SM-Zr: Screwmentable zirconia-porcelain crowns on stock zirconia abutment; AC-Ti: Titanium-porcelain abutment crowns; AC-Zr: Zirconia-porcelain abutment crowns.] Specimens were torqued with 30 NCm and thermocycled between 5℃ and 55℃ in 20-second cycles for 5000 cycles. Removal torque values (RTV) were measured. Following the RTV measurement, the screws were changed with fresh screws and torqued again. Afterwards, specimens were loaded to fracture and fracture strengths were recorded, failure modes were examined. Statistical Analysis Used: Analysis of variance and Bonferroni test was performed. Results: The AC-Ti group displayed the highest mean torque loss (%20.09 ± 6.49) and the SM-Ti group displayed the lowest (%9.59 ± 8.84). Only the difference between AC-Ti and SM-Ti groups was found statistically significant, there are no significant differences between other groups. The fracture strengths are 385.84 ± 27.68 N, 313.18 ± 39.97 N, 272.69 ± 35.03 N, and 156.71 ± 19.83 N for AC-Ti, AC-Zr, SM-Ti, and SM-Zr groups, respectively and all differences were found to be statistically significant. Failures occurred as deformation in titanium components, whereas fractures were observed in zirconia components. Conclusion: Screw loosening was observed only in the AC-Ti group. No significant difference was observed among the torque loss values in the remaining groups. Titanium and zirconia materials do not exert any influence on screw loosening after thermal aging for hybrid-abutment crowns. Moreover, when assessing fracture strength, hybrid-abutment crowns exhibit superior strength and durability compared to screwmentable crowns.


  • Open Access

    Comparative evaluation of desensitizing agents on shear bond strength of zirconia to dentin

    by İrEm Çötert, Merve Aytuğ, H. Serdar Çötert

    The purpose of the study is to evaluate the effect of 7 different desensitizing agents on the shear bond strength (SBS) of zirconia restorations to dentin with a self-adhesive resin cement and determine the failure modes. Eighty molars’ occlusal surfaces were ground to expose dentin and were randomly divided into 8 groups (n = 10): 1. Gluma (HEMA/Glutaraldehyde) 2. Bifluoride (Sodium Fluoride/Calcium Fluoride) 3. Admira (Bis-GMA/HEMA) 4. Smart Protect (Glutaraldehyde) 5. Teethmate (Tetracalcium phosphate, Dicalcium phosphate) 6. Clinpro White (Sodium fluoride) 7. BisBlock (Oxalic acid) and 8. Control (No-treatment). After applying the agent, a self-adhesive resin cement (Rely-X U200) was used to lute zirconia discs (4 mm height and 4 mm diameter) to dentin. After stored in distilled water at 37 °C for 24 h, all groups were thermocycled for 2500 cycles between 5 ± 2 °C and 55 ± 2 °C. Specimens were submitted to SBS test with a universal testing machine at a crosshead speed of 0.5 mm/min until failure. SBS values were compared with ANOVA. Post-hoc multiple comparisons were performed with Dunnett T3. The failure modes of specimens were examined with stereomicroscope at a magnification of 20X and the distribution of the failure modes were evaluated with Pearson Chi-Square test. Regarding mean SBS values in MPa’s; Admira (10.70 ± 3.99), Smart Protect (9.62 ± 3.93), and Gluma (8.90 ± 3.76) treatments showed higher SBS values compared to control group (p < .05) according to ANOVA. The SBS values of Teethmate (5.31 ± 2.37) and Clinpro White (4.32 ± 2.44) were higher than control group but the difference was not found significant (p > .05). BisBlock (2.33 ± 1.94) and Bifluouride (1.60 ± 1.47) groups showed the lowest SBS values but their difference between control group was not found statistically significant (p > .05). Most specimens showed adhesive failure but no statistically significant difference was found in the distributions of failure modes according to Chi-square test. Within the limitation of the study; Admira, Smart Protect, and Gluma increased the SBS of the zirconia restorations to dentin and can be recommended to use on prepared dentin surfaces prior to the cementation.


  • Open Access

    Fixed Prosthodontic Rehabilitation of a Patient with Cleidocranial Dysplasia: A Case Report

    by Merve Karakaya, İrem Çötert, İrem Nur Yücel, H. Serdar Çötert

    Introduction: Cleidocranial Dysplasia (CCD) is a rare congenital disease characterized by skeletal and dental anomalies. Clinical findings of CCD patients include low facial height, pseudoprognathism, unerupted teeth, an excessive deep bite, chewing difficulties, and unsatisfied dentofacial appearance. These patients’ dental treatments present a substantial challenge. Case Representation: This case report describes the prosthodontic treatment of a 29-year-old male CCD patient using porcelain-fused-to-metal restorations. The avoidance of a surgical procedure serves to minimize the potential for complications and expedites the attainment of outcomes with greater celerity. Throughout the follow-up period of 1 year, the patient maintained good periodontal health. The restoration of masticatory function and enhancement of facial esthetics were successfully achieved and the patient expressed a high degree of satisfaction with the outcome of the treatment. Conclusion: The use of fixed prostheses in CCD patients is a treatment modality that resolves many of the issues caused by the surgical approach.

  • Open Access

    Survival of Partial Laminate Veneers and Categorical Covariates Affecting the Survival: A Systematic Review

    by İrEm Çötert, H. Serdar Çötert

    Background: Partial laminate veneers (PLV) have been accepted widely among both clinicians and patients with their favorable specifications, such as conservativeness, superior esthetics, bond strength and durability, for three decades. Various esthetic and functional impairments spreading in a wide range may be restored with veneers instead of full contour crowns. Objective: Although advantages, partial laminate veneers are not free from complications and various factors can influence the service duration of these restorations. Methods: An electronic Pubmed/Medline and Google Academic search was conducted without time restriction, providing information on porcelain laminate veneer’s failure rate and survival. Assessment of the identified studies was performed by two independent reviewers. Clinical service durations and various types of failures were evaluated. Results: Debonding, fracture, discoloration of the porcelain; staining or disintegration of tooth-porcelain margin; hypersensitivity, secondary caries, pulp necrosis and the periodontal responses were the more frequently studied failures. The mean CFR was found as 8,22% per study. Enamel substrate, incisal overlapping and lithium disilicate veneers presented lower failure rates in comparison with dentine substrate, non-overlapping and feldspathic veneers. Conclusion: PLV’s have high survival rates. The overall survival of PLV restorations can be affected by several prognostic variables.