Michael Baldock
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Michael Baldock has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Niamh Gill
School of Health Sciences, University of Salford, Salford, UK
2 shared publications - Samantha Curtin
Centre for Human Movement and Rehabilitation, School of Health and Society, University of Salford, Salford M6 6PU, UK
2 shared publications - Alexander Dickinson
University of Southampton
1 shared publication - Alix Chadwell
School of Healthcare Enterprise and Innovation, Faculty of Medicine, University of Southampton, Southampton SO17 1BJ, UK
1 shared publication - Antonio Capozio
School of Biomedical Sciences, Faculty of Biological Sciences, University of Leeds, Leeds LS2 9JT, UK
1 shared publication - David E. Lunn
Leeds Beckett University
1 shared publication
Latest Publications
- Open Access
- 29 September 2026
- Published by MDPI AG in Bioengineering
- Vol. 13 (10) , 1138
End-Effector Robotic Rehabilitation After Spinal Cord Injury: A Systematic Review of Devices, Operational Characteristics Used, Outcome Measures, and Rehabilitation Effectiveness
Background: End-effector robotic devices are increasingly used in rehabilitation to retrain neural pathways through repetitive, task-specific exercise. However, the influence of movement kinematic variables remains unclear. This systematic review aimed to; (i) identify end-effector robotic systems used in upper- and lower-limb spinal cord injury rehabilitation, (ii) describe their technical specifications and operational use, and (iii) explore associations between device use characteristics and study outcomes. Methods: A systematic review of five databases was conducted from inception to June 2026. Results: Fifteen studies, ten lower-limb and five upper-limb, met the inclusion criteria. These covered five commercially available lower-limb devices and three upper-limb devices. Most lower-limb studies demonstrated moderate-to-large improvements in balance, ambulation (WISCI-II), walking endurance (6mWT), and independence (SCIM-III). End-effector training produced comparable outcomes to both conventional therapy and exoskeleton-based rehabilitation in controlled comparisons. Upper-limb studies showed substantial heterogeneity in outcome selection, reflecting diverse rehabilitation goals. Conclusions: WISCI-II and 10MWT were the most used lower-limb functional assessments, with SCIM-III used to assess independence for both upper- and lower-limb motor impairments. Reporting of kinematic settings are often limited and concentrated at study onset, limiting assessment of their contribution to outcomes. Reporting the progression of session-level metrics is needed to better understand how time-varying kinematics affect intervention effectiveness.
- 29 September 2026
- Published by MDPI AG in Bioengineering
- Vol. 13 (10) , 1138
Open AccessEnd-Effector Robotic Rehabilitation After Spinal Cord Injury: A Systematic Review of Devices, Operational Characteristics Used, Outcome Measures, and Rehabilitation Effectiveness
Background: End-effector robotic devices are increasingly used in rehabilitation to retrain neural pathways through repetitive, task-specific exercise. However, the influence of movement kinematic variables remains unclear. This systematic review aimed to; (i) identify end-effector robotic systems used in upper- and lower-limb spinal cord injury rehabilitation, (ii) describe their technical specifications and operational use, and (iii) explore associations between device use characteristics and study outcomes. Methods: A systematic review of five databases was conducted from inception to June 2026. Results: Fifteen studies, ten lower-limb and five upper-limb, met the inclusion criteria. These covered five commercially available lower-limb devices and three upper-limb devices. Most lower-limb studies demonstrated moderate-to-large improvements in balance, ambulation (WISCI-II), walking endurance (6mWT), and independence (SCIM-III). End-effector training produced comparable outcomes to both conventional therapy and exoskeleton-based rehabilitation in controlled comparisons. Upper-limb studies showed substantial heterogeneity in outcome selection, reflecting diverse rehabilitation goals. Conclusions: WISCI-II and 10MWT were the most used lower-limb functional assessments, with SCIM-III used to assess independence for both upper- and lower-limb motor impairments. Reporting of kinematic settings are often limited and concentrated at study onset, limiting assessment of their contribution to outcomes. Reporting the progression of session-level metrics is needed to better understand how time-varying kinematics affect intervention effectiveness.
- Open Access
- 7 May 2025
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 143 (1) , 104390
Detecting inter-adjustment coupling changes for transtibial adjustable prosthetic sockets: A novel motion capture model feasibility study
Prosthetic sockets provide a connection between the residual limb and prosthesis. However, this connection is non-rigid, leading to unintended prosthesis movement during functional activities. These movements can diminish socket function, cause discomfort, and damage soft tissue. Adjustable sockets allow volumetric adjustments to be made; however, their impact on this connection is unknown. This study aims to assess the feasibility of a novel motion capture model in measuring inter-adjustment level prosthetic movement changes for an adjustable socket. A single male participant with unilateral transtibial amputation was recruited, and a bespoke socket with a large adjustable posterior panel was manufactured. Relative movement and comfort of the prosthesis were measured for five socket tightness settings. The novel model detected significant changes in inter-adjustment level prosthetic movements during swing phase, in both surge and pistoning displacements. However, there was no significant difference in the range of movement over the whole gait cycle. The tightest and loosest socket adjustments produced a detectable difference in comfort. Although specific to this individual and socket design, the novel motion capture model proved effective in detecting differences in adjustable prosthetic socket performance. Quantifying the influence of changes in socket shape facilitates a greater understanding of prosthetic fit and comfort.
- 7 May 2025
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 143 (1) , 104390
Open AccessDetecting inter-adjustment coupling changes for transtibial adjustable prosthetic sockets: A novel motion capture model feasibility study
Prosthetic sockets provide a connection between the residual limb and prosthesis. However, this connection is non-rigid, leading to unintended prosthesis movement during functional activities. These movements can diminish socket function, cause discomfort, and damage soft tissue. Adjustable sockets allow volumetric adjustments to be made; however, their impact on this connection is unknown. This study aims to assess the feasibility of a novel motion capture model in measuring inter-adjustment level prosthetic movement changes for an adjustable socket. A single male participant with unilateral transtibial amputation was recruited, and a bespoke socket with a large adjustable posterior panel was manufactured. Relative movement and comfort of the prosthesis were measured for five socket tightness settings. The novel model detected significant changes in inter-adjustment level prosthetic movements during swing phase, in both surge and pistoning displacements. However, there was no significant difference in the range of movement over the whole gait cycle. The tightest and loosest socket adjustments produced a detectable difference in comfort. Although specific to this individual and socket design, the novel motion capture model proved effective in detecting differences in adjustable prosthetic socket performance. Quantifying the influence of changes in socket shape facilitates a greater understanding of prosthetic fit and comfort.
- Open Access
- 6 November 2023
- Published by Springer Nature in Journal of NeuroEngineering and Rehabilitation
- Vol. 20 (1) , 1-18
Adjustable prosthetic sockets: a systematic review of industrial and research design characteristics and their justifications
Background: The prosthetic socket is a key component that influences prosthesis satisfaction, with a poorly fitting prosthetic socket linked to prosthesis abandonment and reduced community participation. This paper reviews adjustable socket designs, as they have the potential to improve prosthetic fit and comfort through accommodating residual limb volume fluctuations and alleviating undue socket pressure. Methods: Systematic literature and patent searches were conducted across multiple databases to identify articles and patents that discussed adjustable prosthetic sockets. The patents were used to find companies, organisations, and institutions who currently sell adjustable sockets or who are developing devices. Results: 50 literature articles and 63 patents were identified for inclusion, representing 35 different designs used in literature and 16 commercially available products. Adjustable sockets are becoming more prevalent with 73% of publications (literature, patents, and news) occurring within the last ten years. Two key design characteristics were identified: principle of adjustability (inflatable bladders, moveable panels, circumferential adjustment, variable length), and surface form (conformable, rigid multi-DOF, and rigid single DOF). Inflatable bladders contributed to 40% of literature used designs with only one identified commercially available design (n = 16) using this approach. Whereas circumferential adjustment designs covered 75% of identified industry designs compared to only 36% of literature devices. Clinical studies were generally small in size and only 17.6% of them assessed a commercially available socket. Discussion: There are clear differences in the design focus taken by industry and researchers, with justification for choice of design and range of adjustment often being unclear. Whilst comfort is often reported as improved with an adjustable socket, the rationale behind this is not often discussed, and small study sizes reduce the outcome viability. Many adjustable sockets lack appropriate safety features to limit over or under tightening, which may present a risk of tissue damage or provide inadequate coupling, affecting function and satisfaction. Furthermore, the relationship between design and comfort or function are rarely investigated and remain a significant gap in the literature. Finally, this review highlights the need for improved collaboration between academia and industry, with a strong disconnect observed between commercial devices and published research studies.
- 6 November 2023
- Published by Springer Nature in Journal of NeuroEngineering and Rehabilitation
- Vol. 20 (1) , 1-18
Open AccessAdjustable prosthetic sockets: a systematic review of industrial and research design characteristics and their justifications
Background: The prosthetic socket is a key component that influences prosthesis satisfaction, with a poorly fitting prosthetic socket linked to prosthesis abandonment and reduced community participation. This paper reviews adjustable socket designs, as they have the potential to improve prosthetic fit and comfort through accommodating residual limb volume fluctuations and alleviating undue socket pressure. Methods: Systematic literature and patent searches were conducted across multiple databases to identify articles and patents that discussed adjustable prosthetic sockets. The patents were used to find companies, organisations, and institutions who currently sell adjustable sockets or who are developing devices. Results: 50 literature articles and 63 patents were identified for inclusion, representing 35 different designs used in literature and 16 commercially available products. Adjustable sockets are becoming more prevalent with 73% of publications (literature, patents, and news) occurring within the last ten years. Two key design characteristics were identified: principle of adjustability (inflatable bladders, moveable panels, circumferential adjustment, variable length), and surface form (conformable, rigid multi-DOF, and rigid single DOF). Inflatable bladders contributed to 40% of literature used designs with only one identified commercially available design (n = 16) using this approach. Whereas circumferential adjustment designs covered 75% of identified industry designs compared to only 36% of literature devices. Clinical studies were generally small in size and only 17.6% of them assessed a commercially available socket. Discussion: There are clear differences in the design focus taken by industry and researchers, with justification for choice of design and range of adjustment often being unclear. Whilst comfort is often reported as improved with an adjustable socket, the rationale behind this is not often discussed, and small study sizes reduce the outcome viability. Many adjustable sockets lack appropriate safety features to limit over or under tightening, which may present a risk of tissue damage or provide inadequate coupling, affecting function and satisfaction. Furthermore, the relationship between design and comfort or function are rarely investigated and remain a significant gap in the literature. Finally, this review highlights the need for improved collaboration between academia and industry, with a strong disconnect observed between commercial devices and published research studies.