Kenan Ma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kenan Ma has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Hu Chen
Chinese Academy of Medical Sciences
3 shared publications - Yuchun Sun
Chinese Academy of Medical Sciences & NMPA Key Laboratory for Dental Materials
3 shared publications - Sukun Tian
School of Stomatology, Peking University, Beijing 100081, China
2 shared publications - Dong Zhou
Chinese Academy of Medical Sciences
1 shared publication - Enlin Pang
Research and Development Department, Nanjing Profeta Intelligent Technology Co., Ltd
1 shared publication - Hefei Bai
Chinese Academy of Medical Sciences
1 shared publication
Latest Publications
- Open Access
- 31 October 2023
- Published by Taylor & Francis in Virtual and Physical Prototyping
- Vol. 18 (1)
Investigation of the ageing conditions of PEEK powder for the selective laser sintering process
- 31 October 2023
- Published by Taylor & Francis in Virtual and Physical Prototyping
- Vol. 18 (1)
Open AccessInvestigation of the ageing conditions of PEEK powder for the selective laser sintering process
- 19 April 2022
- Published by Emerald Publishing in Rapid Prototyping Journal
- Vol. 28 (9) , 1625-1635
Effects of selective laser melting process parameters on the accuracy of the intaglio surface of maxillary removable partial denture frameworks
Purpose: This in vitro study aims to explore the effects of selective laser melting (SLM) process parameters on the accuracy of the intaglio surface of cobalt–chromium alloy (Co–Cr), commercially pure titanium (CP Ti) and titanium alloy (Ti–6Al–4V) maxillary removable partial denture (RPD) frameworks and optimize these process parameters. Design/methodology/approach: Maxillary RPD framework specimens designed on a benchmark model were built. The process parameters, including contour scan speed and laser power, infill scan speed and laser power, hatch space, build orientation and metallic powder type, were arranged through the Taguchi design. Three-dimensional deviations of the clasps area, connector area and overall area of maxillary RPD frameworks were analyzed by using root mean square (RMS) as a metric. One-way analyses of variance with the above RMSs as the dependent variable were carried out (α = 0.05). Findings: Maxillary RPD frameworks built horizontally had a more accurate intaglio surface than those built at other orientation angles; CP Ti or Ti–6Al–4V maxillary RPD frameworks had a more accurate intaglio surface than Co–Cr ones; the Maxillary RPD framework built with a higher infill scan speed and lower infill laser power had the more accurate intaglio surface than the one built with other levels of these two process parameters. Originality/value: A novel benchmark model for evaluating the accuracy of the intaglio surface of maxillary RPD frameworks manufactured by SLM is proposed. The accuracy of the intaglio surface of maxillary RPD frameworks can be improved by adjusting SLM process parameters. The optimal setting of process parameters concerning the accuracy of the intaglio surface of maxillary RPD frameworks was given.
- 19 April 2022
- Published by Emerald Publishing in Rapid Prototyping Journal
- Vol. 28 (9) , 1625-1635
Effects of selective laser melting process parameters on the accuracy of the intaglio surface of maxillary removable partial denture frameworks
Purpose: This in vitro study aims to explore the effects of selective laser melting (SLM) process parameters on the accuracy of the intaglio surface of cobalt–chromium alloy (Co–Cr), commercially pure titanium (CP Ti) and titanium alloy (Ti–6Al–4V) maxillary removable partial denture (RPD) frameworks and optimize these process parameters. Design/methodology/approach: Maxillary RPD framework specimens designed on a benchmark model were built. The process parameters, including contour scan speed and laser power, infill scan speed and laser power, hatch space, build orientation and metallic powder type, were arranged through the Taguchi design. Three-dimensional deviations of the clasps area, connector area and overall area of maxillary RPD frameworks were analyzed by using root mean square (RMS) as a metric. One-way analyses of variance with the above RMSs as the dependent variable were carried out (α = 0.05). Findings: Maxillary RPD frameworks built horizontally had a more accurate intaglio surface than those built at other orientation angles; CP Ti or Ti–6Al–4V maxillary RPD frameworks had a more accurate intaglio surface than Co–Cr ones; the Maxillary RPD framework built with a higher infill scan speed and lower infill laser power had the more accurate intaglio surface than the one built with other levels of these two process parameters. Originality/value: A novel benchmark model for evaluating the accuracy of the intaglio surface of maxillary RPD frameworks manufactured by SLM is proposed. The accuracy of the intaglio surface of maxillary RPD frameworks can be improved by adjusting SLM process parameters. The optimal setting of process parameters concerning the accuracy of the intaglio surface of maxillary RPD frameworks was given.