Dong Zhou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Dong Zhou has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Enlin Pang
Research and Development Department, Nanjing Profeta Intelligent Technology Co., Ltd
1 shared publication - Hefei Bai
Chinese Academy of Medical Sciences
1 shared publication - Hongqiang Ye
Department of Prosthodontics, Peking University School and Hospital of Stomatology, National Center of Stomatology, National Clinical Research Center for Oral Diseases, National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, No. 22 Zhongguancun South Avenue, Haidian District, Beijing, China, 86 13066994235
1 shared publication - Hu Chen
Chinese Academy of Medical Sciences
1 shared publication - Kenan Ma
Chinese Academy of Medical Sciences
1 shared publication - Shipeng Hu
Chinese Academy of Medical Sciences
1 shared publication
Latest Publications
- Open Access
- 1 January 2026
- Published by XMLink in The Journal of Advanced Prosthodontics
- Vol. 18 (3) , 182-190
Fracture resistance and failure modes in 4- vs. 6-implant supported zirconia full-arch prostheses with and without cantilevers: an in vitro study
To evaluate the fracture resistance and failure modes of IFCDPs supported by 4 versus 6 implants, with and without cantilever loading. Forty monolithic zirconia IFCDP specimens (20 with 4 implants, 20 with 6 implants) were fabricated using CAD-CAM technology and bonded to titanium copings on titanium alloy casts. Specimens were divided into four groups (n = 10 each): Group A (4 implants, non-cantilever load at second premolar), Group B (4 implants, cantilever load at second molar), Group C (6 implants, non-cantilever load at second premolar), and Group D (6 implants, cantilever load at second molar). Mechanical testing was performed using a universal testing machine with a three-point bending fixture loading bilaterally. Failure modes (fracture or cement debonding) and maximum failure loads were recorded. Statistical analysis included Fisher’s exact test for failure mode distribution and two-way ANOVA for failure load. Non-cantilever loading caused framework fractures at high mean loads (Group A: 25,105 ± 5744 N; Group C: 27,189 ± 5753 N), while cantilever loading led to cement debonding at significantly lower failure loads (Group B:1,070 ± 404 N; Group D: 828 ± 432 N). Loading site significantly influenced failure load (P < .001), but implant number and its interaction with loading site had no significant effect (P > .05). Both All-on-4 and All-on-6 zirconia full-arch prostheses show high static fracture resistance, but cantilever loading greatly reduces strength and induces debonding, underscoring the need to minimize cantilever length or improve bonding strategies.
- 1 January 2026
- Published by XMLink in The Journal of Advanced Prosthodontics
- Vol. 18 (3) , 182-190
Open AccessFracture resistance and failure modes in 4- vs. 6-implant supported zirconia full-arch prostheses with and without cantilevers: an in vitro study
To evaluate the fracture resistance and failure modes of IFCDPs supported by 4 versus 6 implants, with and without cantilever loading. Forty monolithic zirconia IFCDP specimens (20 with 4 implants, 20 with 6 implants) were fabricated using CAD-CAM technology and bonded to titanium copings on titanium alloy casts. Specimens were divided into four groups (n = 10 each): Group A (4 implants, non-cantilever load at second premolar), Group B (4 implants, cantilever load at second molar), Group C (6 implants, non-cantilever load at second premolar), and Group D (6 implants, cantilever load at second molar). Mechanical testing was performed using a universal testing machine with a three-point bending fixture loading bilaterally. Failure modes (fracture or cement debonding) and maximum failure loads were recorded. Statistical analysis included Fisher’s exact test for failure mode distribution and two-way ANOVA for failure load. Non-cantilever loading caused framework fractures at high mean loads (Group A: 25,105 ± 5744 N; Group C: 27,189 ± 5753 N), while cantilever loading led to cement debonding at significantly lower failure loads (Group B:1,070 ± 404 N; Group D: 828 ± 432 N). Loading site significantly influenced failure load (P < .001), but implant number and its interaction with loading site had no significant effect (P > .05). Both All-on-4 and All-on-6 zirconia full-arch prostheses show high static fracture resistance, but cantilever loading greatly reduces strength and induces debonding, underscoring the need to minimize cantilever length or improve bonding strategies.