Thomas R. Else
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Thomas R. Else has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
- Sarah Elizabeth Bohndiek
Cancer Research UK Cambridge Institute (United Kingdom)
12 shared publications - Janek Gröhl
Univ. of Cambridge (United Kingdom)
9 shared publications - Lina Hacker
Department of Oncology The University of Oxford UK
5 shared publications - Ellie V. Bunce
University of Cambridge, Cancer Research UK Cambridge Institute, Cambridge, United Kingdom
3 shared publications - Ben T. Cox
Department of Medical Physics and Biomedical Engineering, University College London, London, UK
2 shared publications Ellie V. Bunce
Cancer Research UK Cambridge Institute (United Kingdom)
2 shared publications
Latest Publications
- Open Access
Spectral characterisation of short-wave infrared (SWIR) tissue chromophores and tissue-mimicking phantom optical properties
Significance Short-wave infrared (SWIR) sensors promise to expand the capabilities of optical sensing technologies, but the lack of robust data characterising tissue-constituent optical properties in the SWIR makes instrument design challenging. Aim We characterise and evaluate the optical properties of the dominant chromophores in tissue and tissue- mimicking phantoms, from visible to SWIR wavelengths. Approach Using single-integrating sphere systems, we measured the optical properties of single-component chromophores (H2O, haemoglobin, corn oil, synthetic melanin) and multi-component tissues (whole blood, lard), to decouple contributions from optical scattering, H2O absorption and other contributing chromophores; we also characterised commonly-used phantom materials and investigated their potential to mimic soft tissues in the SWIR range using simulations. Results We provide a consistent dataset of absorption and reduced scattering coefficients (µa and µ's) that characterise the dominant tissue chromophores from 450 nm out to 1600 nm. These results were shown to be consistent with literature data, where available. We integrate these data into an open-source Python toolkit, SIMPA, for optical modelling and demonstrate soft tissue simulations that can be probed continuously from visible to SWIR wavelengths. Our findings are compared with tissue-mimicking phantoms, highlighting a need for additives for polymer-based phantoms that mimic SWIR water absorption. Conclusions By providing this open-source dataset, we aim to enable future studies exploring SWIR light-tissue interactions that facilitate rapid assessment and prototyping of next-generation spectroscopy and imaging techniques.
Open AccessSpectral characterisation of short-wave infrared (SWIR) tissue chromophores and tissue-mimicking phantom optical properties
Significance Short-wave infrared (SWIR) sensors promise to expand the capabilities of optical sensing technologies, but the lack of robust data characterising tissue-constituent optical properties in the SWIR makes instrument design challenging. Aim We characterise and evaluate the optical properties of the dominant chromophores in tissue and tissue- mimicking phantoms, from visible to SWIR wavelengths. Approach Using single-integrating sphere systems, we measured the optical properties of single-component chromophores (H2O, haemoglobin, corn oil, synthetic melanin) and multi-component tissues (whole blood, lard), to decouple contributions from optical scattering, H2O absorption and other contributing chromophores; we also characterised commonly-used phantom materials and investigated their potential to mimic soft tissues in the SWIR range using simulations. Results We provide a consistent dataset of absorption and reduced scattering coefficients (µa and µ's) that characterise the dominant tissue chromophores from 450 nm out to 1600 nm. These results were shown to be consistent with literature data, where available. We integrate these data into an open-source Python toolkit, SIMPA, for optical modelling and demonstrate soft tissue simulations that can be probed continuously from visible to SWIR wavelengths. Our findings are compared with tissue-mimicking phantoms, highlighting a need for additives for polymer-based phantoms that mimic SWIR water absorption. Conclusions By providing this open-source dataset, we aim to enable future studies exploring SWIR light-tissue interactions that facilitate rapid assessment and prototyping of next-generation spectroscopy and imaging techniques.
- Open Access
Photoacoustic imaging in mitochondrial disease
Mitochondrial diseases are a diverse group of inherited neuromuscular disorders leading to progressive disability and early mortality. Mitochondrial myopathy is a common feature of mitochondrial disorders, affecting most patients. Assessment of disease progression and treatment efficacy in mitochondrial disease trials has often relied on muscle biopsies, however, these are increasingly considered unfavourable by patients. Imaging biomarkers of disease could reduce the patient burden, enabling non-invasive longitudinal monitoring of molecular information. Photoacoustic imaging combines the molecular sensitivity of light absorption with the deep tissue imaging capabilities of ultrasound, enabling a safe and fast imaging technique. Tuning the wavelength of light allows for the detection of molecular constituents such as oxy- and deoxy-haemoglobin, lipids, and water. These signatures may reflect underlying pathophysiological alterations and serve as valuable indicators of disease state and progression. We conducted an exploratory study of a photoacoustic imaging dataset in patients with mitochondrial myopathy due to the m.3243A>G mt-tRNALeu mutation and compared to healthy volunteers. We generated photoacoustic measurements at wavelengths in the near infrared, comparing absolute values and ratios derived in the bicep muscle. Confounding factors such as skin colour and sex were considered, and we ensured that these parameters were matched in healthy volunteers and patients. We identified significant differences between patients and controls, revealing changes in ratios between water and total haemoglobin, lipid and total haemoglobin, and lipid and water content. This study highlights the promise of photoacoustic imaging as a novel imaging biomarker in mitochondrial myopathies, paving the way for larger scale studies.
Open AccessPhotoacoustic imaging in mitochondrial disease
Mitochondrial diseases are a diverse group of inherited neuromuscular disorders leading to progressive disability and early mortality. Mitochondrial myopathy is a common feature of mitochondrial disorders, affecting most patients. Assessment of disease progression and treatment efficacy in mitochondrial disease trials has often relied on muscle biopsies, however, these are increasingly considered unfavourable by patients. Imaging biomarkers of disease could reduce the patient burden, enabling non-invasive longitudinal monitoring of molecular information. Photoacoustic imaging combines the molecular sensitivity of light absorption with the deep tissue imaging capabilities of ultrasound, enabling a safe and fast imaging technique. Tuning the wavelength of light allows for the detection of molecular constituents such as oxy- and deoxy-haemoglobin, lipids, and water. These signatures may reflect underlying pathophysiological alterations and serve as valuable indicators of disease state and progression. We conducted an exploratory study of a photoacoustic imaging dataset in patients with mitochondrial myopathy due to the m.3243A>G mt-tRNALeu mutation and compared to healthy volunteers. We generated photoacoustic measurements at wavelengths in the near infrared, comparing absolute values and ratios derived in the bicep muscle. Confounding factors such as skin colour and sex were considered, and we ensured that these parameters were matched in healthy volunteers and patients. We identified significant differences between patients and controls, revealing changes in ratios between water and total haemoglobin, lipid and total haemoglobin, and lipid and water content. This study highlights the promise of photoacoustic imaging as a novel imaging biomarker in mitochondrial myopathies, paving the way for larger scale studies.
- Top Cited PapersOpen Access
- 5 July 2025
- Published by Elsevier in Photoacoustics
- Vol. 45, 100745
Artifacts in photoacoustic imaging: Origins and mitigations
- 5 July 2025
- Published by Elsevier in Photoacoustics
- Vol. 45, 100745
Top Cited PapersOpen AccessArtifacts in photoacoustic imaging: Origins and mitigations
- Open Access
- 1 July 2025
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 158 (1) , 590-601
Digital twins enable full-reference quality assessment of photoacoustic image reconstructions
Quantitative comparison of the quality of photoacoustic image reconstruction algorithms remains a major challenge. No-reference image quality measures are often inadequate, but full-reference measures require access to an ideal reference image. While the ground truth is known in simulations, it is unknown in vivo or in phantom studies, as the reference depends on both the phantom properties and the imaging system. This paper tackles this problem by using numerical digital twins of tissue-mimicking phantoms and the imaging system to perform a quantitative calibration to reduce the simulation gap. The contributions of this paper are twofold: First, this digital-twin framework is used to compare multiple state-of-the-art reconstruction algorithms. Second, among these is a Fourier transform-based reconstruction algorithm for circular detection geometries, which is tested on experimental data for the first time. The results demonstrate the usefulness of digital phantom twins by enabling assessment of the accuracy of the numerical forward model and enabling comparison of image reconstruction schemes with full-reference image quality assessment. This paper shows that the Fourier transform-based algorithm yields results comparable to those of iterative time reversal, but at a lower computational cost.
- 1 July 2025
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 158 (1) , 590-601
Open AccessDigital twins enable full-reference quality assessment of photoacoustic image reconstructions
Quantitative comparison of the quality of photoacoustic image reconstruction algorithms remains a major challenge. No-reference image quality measures are often inadequate, but full-reference measures require access to an ideal reference image. While the ground truth is known in simulations, it is unknown in vivo or in phantom studies, as the reference depends on both the phantom properties and the imaging system. This paper tackles this problem by using numerical digital twins of tissue-mimicking phantoms and the imaging system to perform a quantitative calibration to reduce the simulation gap. The contributions of this paper are twofold: First, this digital-twin framework is used to compare multiple state-of-the-art reconstruction algorithms. Second, among these is a Fourier transform-based reconstruction algorithm for circular detection geometries, which is tested on experimental data for the first time. The results demonstrate the usefulness of digital phantom twins by enabling assessment of the accuracy of the numerical forward model and enabling comparison of image reconstruction schemes with full-reference image quality assessment. This paper shows that the Fourier transform-based algorithm yields results comparable to those of iterative time reversal, but at a lower computational cost.
- 20 March 2025
- Published by SPIE-Intl Soc Optical Eng
- Vol. 13319, 103-201
Artifacts in photoacoustic imaging
Photoacoustic imaging (PAI) is rapidly moving from the laboratory to the clinic, increasing the pressure to understand factors that confound image interpretation, such as noise and image artifacts, which might adversely affect patient care. Over the past five years, landmark studies have shown the potential clinical utility of PAI, from breast cancer to Crohn’s disease and neuromuscular dystrophies, leading to recent FDA approval and CE marking of PAI devices. Here, with a view to better presenting and understanding confounding factors in PAI that could influence image interpretation, we will describe the cause and effects of several artifacts present in PA systems, and giving schematic overviews of their appearance to ease identification.
- 20 March 2025
- Published by SPIE-Intl Soc Optical Eng
- Vol. 13319, 103-201
Artifacts in photoacoustic imaging
Photoacoustic imaging (PAI) is rapidly moving from the laboratory to the clinic, increasing the pressure to understand factors that confound image interpretation, such as noise and image artifacts, which might adversely affect patient care. Over the past five years, landmark studies have shown the potential clinical utility of PAI, from breast cancer to Crohn’s disease and neuromuscular dystrophies, leading to recent FDA approval and CE marking of PAI devices. Here, with a view to better presenting and understanding confounding factors in PAI that could influence image interpretation, we will describe the cause and effects of several artifacts present in PA systems, and giving schematic overviews of their appearance to ease identification.
- 20 March 2025
- Published by SPIE-Intl Soc Optical Eng
- Vol. PC13319, 37
Quantification of optical absorption from preclinical photoacoustic images with semisupervised deep learning (Conference Presentation)
Photoacoustic imaging promises functional characterisation of biological tissues, but challenges in quantifying derived biomarkers hinder progress. Additionally, the validation of photoacoustic data processing algorithms is complex due to a simulation gap between simulated and experimental data. In this work, we present a two-stage semi-supervised deep learning approach to tackling these problems. In the first stage, we use time series-domain data to close the aforementioned simulation gap using a semi-supervised training approach. In the second stage, we train a supervised network for the quantification of the optical absorption coefficient from a hybrid dataset of experimental and simulated spatial-domain images. Our results show that we can effectively close the simulation gap and transform the qualitative photoacoustic images into a quantitative domain that is highly correlated with the optical absorption coefficient.
- 20 March 2025
- Published by SPIE-Intl Soc Optical Eng
- Vol. PC13319, 37
Quantification of optical absorption from preclinical photoacoustic images with semisupervised deep learning (Conference Presentation)
Photoacoustic imaging promises functional characterisation of biological tissues, but challenges in quantifying derived biomarkers hinder progress. Additionally, the validation of photoacoustic data processing algorithms is complex due to a simulation gap between simulated and experimental data. In this work, we present a two-stage semi-supervised deep learning approach to tackling these problems. In the first stage, we use time series-domain data to close the aforementioned simulation gap using a semi-supervised training approach. In the second stage, we train a supervised network for the quantification of the optical absorption coefficient from a hybrid dataset of experimental and simulated spatial-domain images. Our results show that we can effectively close the simulation gap and transform the qualitative photoacoustic images into a quantitative domain that is highly correlated with the optical absorption coefficient.
- 20 March 2025
- Published by SPIE-Intl Soc Optical Eng
- Vol. PC13323, PC133230B
Chemical imaging reveals metabolite distribution in tissues using Raman microspectroscopy
Metabolite distribution in living systems is crucial for understanding cellular processes and disease states. Here, we demonstrate that combining spontaneous Raman spectroscopy and stimulated Raman scattering (SRS) microscopy can detect and map fumarate. We identify, based on prior work, a distinct fumarate peak at 1403±5cm-1 and employ ratiometric SRS imaging to highlight the contrast between fumarate and other cellular constituents. Our results show significant differences in fumarate content between normal and fumarate hydratase deficient tissues, consistent with metabolomics measurements. We optimised large-area tissue mapping using image stitching for whole-tissue visualisation, enabling in situ assessment of fumarate distribution. Future studies will focus on expanding this technique to investigate various metabolites in different biomedical contexts, advancing Raman scattering as a valuable tool for label-free, small molecule metabolic imaging.
- 20 March 2025
- Published by SPIE-Intl Soc Optical Eng
- Vol. PC13323, PC133230B
Chemical imaging reveals metabolite distribution in tissues using Raman microspectroscopy
Metabolite distribution in living systems is crucial for understanding cellular processes and disease states. Here, we demonstrate that combining spontaneous Raman spectroscopy and stimulated Raman scattering (SRS) microscopy can detect and map fumarate. We identify, based on prior work, a distinct fumarate peak at 1403±5cm-1 and employ ratiometric SRS imaging to highlight the contrast between fumarate and other cellular constituents. Our results show significant differences in fumarate content between normal and fumarate hydratase deficient tissues, consistent with metabolomics measurements. We optimised large-area tissue mapping using image stitching for whole-tissue visualisation, enabling in situ assessment of fumarate distribution. Future studies will focus on expanding this technique to investigate various metabolites in different biomedical contexts, advancing Raman scattering as a valuable tool for label-free, small molecule metabolic imaging.
- Open Access
- 17 October 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (21) , 215007
Performance evaluation of image co-registration methods in photoacoustic mesoscopy of the vasculature
Objective. The formation of functional vasculature in solid tumours enables delivery of oxygen and nutrients, and is vital for effective treatment with chemotherapeutic agents. Longitudinal characterisation of vascular networks can be enabled using mesoscopic photoacoustic imaging, but requires accurate image co-registration to precisely assess local changes across disease development or in response to therapy. Co-registration in photoacoustic imaging is challenging due to the complex nature of the generated signal, including the sparsity of data, artefacts related to the illumination/detection geometry, scan-to-scan technical variability, and biological variability, such as transient changes in perfusion. To better inform the choice of co-registration algorithms, we compared five open-source methods, in physiological and pathological tissues, with the aim of aligning evolving vascular networks in tumours imaged over growth at different time-points. Approach. Co-registration techniques were applied to 3D vascular images acquired with photoacoustic mesoscopy from murine ears and breast cancer patient-derived xenografts, at a fixed time-point and longitudinally. Images were pre-processed and segmented using an unsupervised generative adversarial network. To compare co-registration quality in different settings, pairs of fixed and moving intensity images and/or segmentations were fed into five methods split into the following categories: affine intensity-based using (1) mutual information (MI) or (2) normalised cross-correlation (NCC) as optimisation metrics, affine shape-based using (3) NCC applied to distance-transformed segmentations or (4) iterative closest point algorithm, and deformable weakly supervised deep learning-based using (5) LocalNet co-registration. Percent-changes in Dice coefficients, surface distances, MI, structural similarity index measure and target registration errors were evaluated. Main results. Co-registration using MI or NCC provided similar alignment performance, better than shape-based methods. LocalNet provided accurate co-registration of substructures by optimising subfield deformation throughout the volumes, outperforming other methods, especially in the longitudinal breast cancer xenograft dataset by minimising target registration errors. Significance. We showed the feasibility of co-registering repeatedly or longitudinally imaged vascular networks in photoacoustic mesoscopy, taking a step towards longitudinal quantitative characterisation of these complex structures. These tools open new outlooks for monitoring tumour angiogenesis at the meso-scale and for quantifying treatment-induced co-localised alterations in the vasculature.
- 17 October 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (21) , 215007
Open AccessPerformance evaluation of image co-registration methods in photoacoustic mesoscopy of the vasculature
Objective. The formation of functional vasculature in solid tumours enables delivery of oxygen and nutrients, and is vital for effective treatment with chemotherapeutic agents. Longitudinal characterisation of vascular networks can be enabled using mesoscopic photoacoustic imaging, but requires accurate image co-registration to precisely assess local changes across disease development or in response to therapy. Co-registration in photoacoustic imaging is challenging due to the complex nature of the generated signal, including the sparsity of data, artefacts related to the illumination/detection geometry, scan-to-scan technical variability, and biological variability, such as transient changes in perfusion. To better inform the choice of co-registration algorithms, we compared five open-source methods, in physiological and pathological tissues, with the aim of aligning evolving vascular networks in tumours imaged over growth at different time-points. Approach. Co-registration techniques were applied to 3D vascular images acquired with photoacoustic mesoscopy from murine ears and breast cancer patient-derived xenografts, at a fixed time-point and longitudinally. Images were pre-processed and segmented using an unsupervised generative adversarial network. To compare co-registration quality in different settings, pairs of fixed and moving intensity images and/or segmentations were fed into five methods split into the following categories: affine intensity-based using (1) mutual information (MI) or (2) normalised cross-correlation (NCC) as optimisation metrics, affine shape-based using (3) NCC applied to distance-transformed segmentations or (4) iterative closest point algorithm, and deformable weakly supervised deep learning-based using (5) LocalNet co-registration. Percent-changes in Dice coefficients, surface distances, MI, structural similarity index measure and target registration errors were evaluated. Main results. Co-registration using MI or NCC provided similar alignment performance, better than shape-based methods. LocalNet provided accurate co-registration of substructures by optimising subfield deformation throughout the volumes, outperforming other methods, especially in the longitudinal breast cancer xenograft dataset by minimising target registration errors. Significance. We showed the feasibility of co-registering repeatedly or longitudinally imaged vascular networks in photoacoustic mesoscopy, taking a step towards longitudinal quantitative characterisation of these complex structures. These tools open new outlooks for monitoring tumour angiogenesis at the meso-scale and for quantifying treatment-induced co-localised alterations in the vasculature.
- Open Access
- 1 June 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 29 (S3) , S33303-18
Distribution-informed and wavelength-flexible data-driven photoacoustic oximetry
Blood oxygen saturation () is an important indicator of individual health status used routinely in patient management.1 Photoacoustic (PA) imaging (PAI) is a promising medical imaging modality for real-time non-invasive spatially resolved measurement of ,2 with early clinical applications3 shown in, for example, inflammatory bowel disease4 and cardiovascular diseases.5 In cancer, alterations in localized levels have been linked to angiogenesis and hypoxia,6 the key hallmarks of cancer that are known to affect treatment outcomes7 and are measurable through PAI.- 1 June 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 29 (S3) , S33303-18
Open AccessDistribution-informed and wavelength-flexible data-driven photoacoustic oximetry
Blood oxygen saturation () is an important indicator of individual health status used routinely in patient management.1 Photoacoustic (PA) imaging (PAI) is a promising medical imaging modality for real-time non-invasive spatially resolved measurement of ,2 with early clinical applications3 shown in, for example, inflammatory bowel disease4 and cardiovascular diseases.5 In cancer, alterations in localized levels have been linked to angiogenesis and hypoxia,6 the key hallmarks of cancer that are known to affect treatment outcomes7 and are measurable through PAI. - Open Access
- 19 January 2024
- Published by The Open Journal in Journal of Open Source Software
- Vol. 9 (93) , 5686
PATATO: a Python photoacoustic tomography analysis toolkit
Photoacoustic imaging (PAI) is an emerging scalable imaging technology that combines the high contrast of optical imaging with the spatiotemporal resolution of ultrasound (Beard, 2011). Using light absorption by endogenous molecules, such as haemoglobin in red blood cells, PAI can reveal the emergence of diseases ranging from inflammation to cancer in both preclinical animal models and in patients (Brown et al., 2019; Regensburger et al., 2021; Steinberg et al., 2019; Wang & Hu, 2012). Extracting accurate photoacoustic imaging biomarkers, such as blood oxygen saturation, from raw data requires a robust image reconstruction and analysis process, which is challenging due to the high dimensionality of the data across spatial, spectral and temporal domains. Here we introduce PATATO, a Python toolkit that offers fast implementations of commonly-used data analysis methods, including preprocessing, reconstruction and temporal data analysis, via a user-friendly command-line interface and Python API. The toolkit uses JAX, a modern machine learning tool, for GPUaccelerated pre-processing and image reconstruction, and NumPy for easy integration with other commonly used Python libraries. PATATO is open-source, hosted on GitHub and PyPi, and distributed under an MIT licence. We have designed PATATO to be modular and extendable to accommodate different data types, reconstruction methods, and custom analyses for specific scientific questions. We welcome contributions, bug reports, and feedback. Detailed examples,
- 19 January 2024
- Published by The Open Journal in Journal of Open Source Software
- Vol. 9 (93) , 5686
Open AccessPATATO: a Python photoacoustic tomography analysis toolkit
Photoacoustic imaging (PAI) is an emerging scalable imaging technology that combines the high contrast of optical imaging with the spatiotemporal resolution of ultrasound (Beard, 2011). Using light absorption by endogenous molecules, such as haemoglobin in red blood cells, PAI can reveal the emergence of diseases ranging from inflammation to cancer in both preclinical animal models and in patients (Brown et al., 2019; Regensburger et al., 2021; Steinberg et al., 2019; Wang & Hu, 2012). Extracting accurate photoacoustic imaging biomarkers, such as blood oxygen saturation, from raw data requires a robust image reconstruction and analysis process, which is challenging due to the high dimensionality of the data across spatial, spectral and temporal domains. Here we introduce PATATO, a Python toolkit that offers fast implementations of commonly-used data analysis methods, including preprocessing, reconstruction and temporal data analysis, via a user-friendly command-line interface and Python API. The toolkit uses JAX, a modern machine learning tool, for GPUaccelerated pre-processing and image reconstruction, and NumPy for easy integration with other commonly used Python libraries. PATATO is open-source, hosted on GitHub and PyPi, and distributed under an MIT licence. We have designed PATATO to be modular and extendable to accommodate different data types, reconstruction methods, and custom analyses for specific scientific questions. We welcome contributions, bug reports, and feedback. Detailed examples,