Ellie V. Bunce
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ellie V. Bunce has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Janek Gröhl
Univ. of Cambridge (United Kingdom)
3 shared publications - Lina Hacker
Department of Oncology The University of Oxford UK
3 shared publications - Sarah Elizabeth Bohndiek
Cancer Research UK Cambridge Institute (United Kingdom)
3 shared publications - Thomas R. Else
University of Cambridge, Department of Physics
3 shared publications - Kevin Gu
University of Cambridge, Cancer Research UK Cambridge Institute, Cambridge, United Kingdom
1 shared publication - Kylie Yeung
Oxford Centre for Clinical Magnetic Resonance Research University of Oxford Oxford UK
1 shared publication
Latest Publications
- Open Access
- 1 June 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 29 (S3) , S33303-18
Distribution-informed and wavelength-flexible data-driven photoacoustic oximetry
Blood oxygen saturation () is an important indicator of individual health status used routinely in patient management.1 Photoacoustic (PA) imaging (PAI) is a promising medical imaging modality for real-time non-invasive spatially resolved measurement of ,2 with early clinical applications3 shown in, for example, inflammatory bowel disease4 and cardiovascular diseases.5 In cancer, alterations in localized levels have been linked to angiogenesis and hypoxia,6 the key hallmarks of cancer that are known to affect treatment outcomes7 and are measurable through PAI.- 1 June 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 29 (S3) , S33303-18
Open AccessDistribution-informed and wavelength-flexible data-driven photoacoustic oximetry
Blood oxygen saturation () is an important indicator of individual health status used routinely in patient management.1 Photoacoustic (PA) imaging (PAI) is a promising medical imaging modality for real-time non-invasive spatially resolved measurement of ,2 with early clinical applications3 shown in, for example, inflammatory bowel disease4 and cardiovascular diseases.5 In cancer, alterations in localized levels have been linked to angiogenesis and hypoxia,6 the key hallmarks of cancer that are known to affect treatment outcomes7 and are measurable through PAI. - Open Access
- 20 December 2023
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 29 (S1) , S11506-17
Effects of skin tone on photoacoustic imaging and oximetry
Photoacoustic imaging (PAI) is an emerging molecular imaging modality that provides contrast based on the absorption of light by different molecules (chromophores) in tissue. These molecules may be endogenous, such as hemoglobin, melanin, lipids and water, or exogenous, covering a range of contrast agents.1,2 PAI has the potential to recover the concentration of each of these chromophores based on their unique optical absorption spectra, by acquiring data at multiple wavelengths and subjecting the reconstructed images to multispectral processing methods.3 For example, the recovery of relative concentrations of oxy- and deoxy-hemoglobin is commonly used to derive oxygenation maps from PAI with linear spectral unmixing.4 Obtaining accurate maps of chromophore concentrations, however, is limited by spatial variations in light fluence, which are significant at depth and are highly dependent on the surrounding distribution of optical absorbers and scatterers.3 This is often referred to as ‘spectral coloring’. Several factors can affect tissue optical properties, including age,5 low blood perfusion,6 or skin tone,7 which consequently affect the ability to extract quantitative information from PAI.
- 20 December 2023
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 29 (S1) , S11506-17
Open AccessEffects of skin tone on photoacoustic imaging and oximetry
Photoacoustic imaging (PAI) is an emerging molecular imaging modality that provides contrast based on the absorption of light by different molecules (chromophores) in tissue. These molecules may be endogenous, such as hemoglobin, melanin, lipids and water, or exogenous, covering a range of contrast agents.1,2 PAI has the potential to recover the concentration of each of these chromophores based on their unique optical absorption spectra, by acquiring data at multiple wavelengths and subjecting the reconstructed images to multispectral processing methods.3 For example, the recovery of relative concentrations of oxy- and deoxy-hemoglobin is commonly used to derive oxygenation maps from PAI with linear spectral unmixing.4 Obtaining accurate maps of chromophore concentrations, however, is limited by spatial variations in light fluence, which are significant at depth and are highly dependent on the surrounding distribution of optical absorbers and scatterers.3 This is often referred to as ‘spectral coloring’. Several factors can affect tissue optical properties, including age,5 low blood perfusion,6 or skin tone,7 which consequently affect the ability to extract quantitative information from PAI.
- Open Access
- 8 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 43 (3) , 1214-1224
Moving Beyond Simulation: Data-Driven Quantitative Photoacoustic Imaging Using Tissue-Mimicking Phantoms
Accurate measurement of optical absorption coefficients from photoacoustic imaging (PAI) data would enable direct mapping of molecular concentrations, providing vital clinical insight. The ill-posed nature of the problem of absorption coefficient recovery has prohibited PAI from achieving this goal in living systems due to the domain gap between simulation and experiment. To bridge this gap, we introduce a collection of experimentally well-characterised imaging phantoms and their digital twins. This first-of-a-kind phantom data set enables supervised training of a U-Net on experimental data for pixel-wise estimation of absorption coefficients. We show that training on simulated data results in artefacts and biases in the estimates, reinforcing the existence of a domain gap between simulation and experiment. Training on experimentally acquired data, however, yielded more accurate and robust estimates of optical absorption coefficients. We compare the results to fluence correction with a Monte Carlo model from reference optical properties of the materials, which yields a quantification error of approximately 20%. Application of the trained U-Nets to a blood flow phantom demonstrated spectral biases when training on simulated data, while application to a mouse model highlighted the ability of both learning-based approaches to recover the depth-dependent loss of signal intensity. We demonstrate that training on experimental phantoms can restore the correlation of signal amplitudes measured in depth. While the absolute quantification error remains high and further improvements are needed, our results highlight the promise of deep learning to advance quantitative PAI.
- 8 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 43 (3) , 1214-1224
Open AccessMoving Beyond Simulation: Data-Driven Quantitative Photoacoustic Imaging Using Tissue-Mimicking Phantoms
Accurate measurement of optical absorption coefficients from photoacoustic imaging (PAI) data would enable direct mapping of molecular concentrations, providing vital clinical insight. The ill-posed nature of the problem of absorption coefficient recovery has prohibited PAI from achieving this goal in living systems due to the domain gap between simulation and experiment. To bridge this gap, we introduce a collection of experimentally well-characterised imaging phantoms and their digital twins. This first-of-a-kind phantom data set enables supervised training of a U-Net on experimental data for pixel-wise estimation of absorption coefficients. We show that training on simulated data results in artefacts and biases in the estimates, reinforcing the existence of a domain gap between simulation and experiment. Training on experimentally acquired data, however, yielded more accurate and robust estimates of optical absorption coefficients. We compare the results to fluence correction with a Monte Carlo model from reference optical properties of the materials, which yields a quantification error of approximately 20%. Application of the trained U-Nets to a blood flow phantom demonstrated spectral biases when training on simulated data, while application to a mouse model highlighted the ability of both learning-based approaches to recover the depth-dependent loss of signal intensity. We demonstrate that training on experimental phantoms can restore the correlation of signal amplitudes measured in depth. While the absolute quantification error remains high and further improvements are needed, our results highlight the promise of deep learning to advance quantitative PAI.