M. Mahabubur Rahman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
M. Mahabubur Rahman has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
Bappa Sarkar
Bio IT Convergence Laboratory, Department of Electronic Convergence Engineering, 20 Kwangwoon-ro, Nowon-gu, Kwang-woon University, Seoul, 01897, Republic of Korea
5 shared publications- Joon Sub Shim
Bio IT Convergence Laboratory, Department of Electronic Convergence Engineering, 20 Kwangwoon-ro, Nowon-gu, Kwang-woon University, Seoul 01897, Republic of Korea
5 shared publications Joon S. Shim
4 shared publications- Nabil Hossain Bhuiyan
Bio IT Convergence Laboratory, Department of Electronic Convergence Engineering, 20 Kwangwoon-ro, Nowon-gu, Kwang-woon University, Seoul, 01897, Republic of Korea
4 shared publications - Sarwar Hossen
Bio IT Convergence Laboratory, Department of Electronic Convergence Engineering, 20 Kwangwoon-ro, Nowon-gu, Kwang-woon University, Seoul, 01897, Republic of Korea
4 shared publications - Gyeong J. Jin
Bio IT Convergence Laboratory, Department of Electronic Convergence Engineering, Kwang-woon University, 20 Kwangwoon-ro, Nowon-gu, Seoul 01897, Republic of Korea
3 shared publications
Latest Publications
- 4 October 2025
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 292, 118063
Amplification of electrochemical signal by moving interdigitated electrode array for highly sensitive detection of Alzheimer's disease markers in blood
- 4 October 2025
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 292, 118063
Amplification of electrochemical signal by moving interdigitated electrode array for highly sensitive detection of Alzheimer's disease markers in blood
- 15 July 2025
- Published by Elsevier in Journal of Power Sources
- Vol. 654
Laser-induced graphite-graphene matrix with pre-lithiation for high-performance lithium-ion battery
- 15 July 2025
- Published by Elsevier in Journal of Power Sources
- Vol. 654
Laser-induced graphite-graphene matrix with pre-lithiation for high-performance lithium-ion battery
- 17 June 2025
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 393
Wrist-wearable blood flow meter by biomimetically structured conductive PDMS composite
- 17 June 2025
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 393
Wrist-wearable blood flow meter by biomimetically structured conductive PDMS composite
- 2 June 2025
- Published by Elsevier in Journal of Power Sources
- Vol. 650
High density 3D-structured graphene for long-life and high energy density lithium-ion battery
- 2 June 2025
- Published by Elsevier in Journal of Power Sources
- Vol. 650
High density 3D-structured graphene for long-life and high energy density lithium-ion battery
- 11 November 2024
- Published by Elsevier in Journal of Power Sources
- Vol. 626
Polyethersulfone-based thick polymer-supported graphene sheet for high energy density lithium-ion battery
- 11 November 2024
- Published by Elsevier in Journal of Power Sources
- Vol. 626
Polyethersulfone-based thick polymer-supported graphene sheet for high energy density lithium-ion battery
- 6 September 2024
- Published by Royal Society of Chemistry (RSC) in Biomaterials Science
- Vol. 12 (20) , 5203-5214
Development of a highly sensitive CNT-metal graphene hybrid nano-IDA electrochemical biosensor for the diagnosis of Alzheimer's disease
The blood-based detection of Alzheimer's disease (AD) is becoming challenging since the blood–brain barrier (BBB) restricts the direct circulation of AD molecules in the blood, thereby precluding the detection of AD at an early-stage. Herein, we report the development of a novel CNT-metal-porous graphene hybrid (CNT-MGH) nano-interdigitated array (n-IDA) electrochemical 8-well biosensor for the successful early-stage diagnosis of AD from blood. Laser-induced graphene (LIG) technology has been used to fabricate the proposed CNT-MGH n-IDA 8-well sensor. Firstly, the electrochemical characterization (i.e., electrode gap, material composition, etc.) of the proposed sensor was demonstrated by measuring p-aminophenol (PAP) with a limit of detection (LOD) of 0.1 picomole. Subsequently, the CNT-MGH n-IDA 8-well sensor was then used to diagnose AD via novel blood biomarkers p-Tau 217 and p-Tau 181 using an electrochemical enzyme-linked immunosorbent assay (e-ELISA) enzyme by-product PAP. During e-ELISA, the alkaline phosphatase enzyme (IgG-AP) tagged to the detection antibody produced an electroactive ELISA by-product PAP by reacting with the enzyme–substrate 4-aminophenyl phosphate (PAPP). Finally, the CNT-MGH n-IDA 8-well sensor was then used to measure the current generated by the redox reaction via the e-ELISA by-product PAP. While quantified, the proposed CNT-MGH n-IDA 8-well sensor successfully detected p-Tau 217 and p-Tau 181 proteins in blood with LODs of 0.16 pg ml−1 and 0.08 pg ml−1, respectively.
- 6 September 2024
- Published by Royal Society of Chemistry (RSC) in Biomaterials Science
- Vol. 12 (20) , 5203-5214
Development of a highly sensitive CNT-metal graphene hybrid nano-IDA electrochemical biosensor for the diagnosis of Alzheimer's disease
The blood-based detection of Alzheimer's disease (AD) is becoming challenging since the blood–brain barrier (BBB) restricts the direct circulation of AD molecules in the blood, thereby precluding the detection of AD at an early-stage. Herein, we report the development of a novel CNT-metal-porous graphene hybrid (CNT-MGH) nano-interdigitated array (n-IDA) electrochemical 8-well biosensor for the successful early-stage diagnosis of AD from blood. Laser-induced graphene (LIG) technology has been used to fabricate the proposed CNT-MGH n-IDA 8-well sensor. Firstly, the electrochemical characterization (i.e., electrode gap, material composition, etc.) of the proposed sensor was demonstrated by measuring p-aminophenol (PAP) with a limit of detection (LOD) of 0.1 picomole. Subsequently, the CNT-MGH n-IDA 8-well sensor was then used to diagnose AD via novel blood biomarkers p-Tau 217 and p-Tau 181 using an electrochemical enzyme-linked immunosorbent assay (e-ELISA) enzyme by-product PAP. During e-ELISA, the alkaline phosphatase enzyme (IgG-AP) tagged to the detection antibody produced an electroactive ELISA by-product PAP by reacting with the enzyme–substrate 4-aminophenyl phosphate (PAPP). Finally, the CNT-MGH n-IDA 8-well sensor was then used to measure the current generated by the redox reaction via the e-ELISA by-product PAP. While quantified, the proposed CNT-MGH n-IDA 8-well sensor successfully detected p-Tau 217 and p-Tau 181 proteins in blood with LODs of 0.16 pg ml−1 and 0.08 pg ml−1, respectively.
- Open Access
- 3 July 2024
- Published by Wiley in Small Methods
- Vol. 8 (9) , e2400189
Polymer‐Supported Graphene Sheet as a Vertically Conductive Anode of Lithium‐Ion Battery
The increasing demand for electric vehicles necessitates the development of cost‐effective, mass‐producible, long‐lasting, and highly conductive batteries. Making this kind of battery is exceedingly tricky. This study introduces an innovative fabrication technique utilizing a laser‐induced graphene (LIG) approach on commercial Kapton film to create hexagonal pores. These pores form vertical conduction paths for electron and ion transportation during lithiation and delithiation, significantly enhancing conductivity. The nongraphitized portion of the Kapton film makes it a binder‐less, free‐standing electrode, providing mechanical stability. Various analytical techniques, including scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), Raman spectroscopy, and atomic force microscopy (AFM) are utilized to confirm the transformation of a 3D porous graphene sheet from a commercial Kapton film. Cross‐sectional SEM images verify the vertical connections. The specific capacity of 581 mAh g−1 is maintained until the end, with 99% coulombic efficiency at 0.1C. This simple manufacturing method paves the pathway for future LIG‐based, cost‐effective, lightweight, mass‐producible, long‐lasting, vertically conductive electrodes for lithium‐ion batteries.
- 3 July 2024
- Published by Wiley in Small Methods
- Vol. 8 (9) , e2400189
Open AccessPolymer‐Supported Graphene Sheet as a Vertically Conductive Anode of Lithium‐Ion Battery
The increasing demand for electric vehicles necessitates the development of cost‐effective, mass‐producible, long‐lasting, and highly conductive batteries. Making this kind of battery is exceedingly tricky. This study introduces an innovative fabrication technique utilizing a laser‐induced graphene (LIG) approach on commercial Kapton film to create hexagonal pores. These pores form vertical conduction paths for electron and ion transportation during lithiation and delithiation, significantly enhancing conductivity. The nongraphitized portion of the Kapton film makes it a binder‐less, free‐standing electrode, providing mechanical stability. Various analytical techniques, including scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), Raman spectroscopy, and atomic force microscopy (AFM) are utilized to confirm the transformation of a 3D porous graphene sheet from a commercial Kapton film. Cross‐sectional SEM images verify the vertical connections. The specific capacity of 581 mAh g−1 is maintained until the end, with 99% coulombic efficiency at 0.1C. This simple manufacturing method paves the pathway for future LIG‐based, cost‐effective, lightweight, mass‐producible, long‐lasting, vertically conductive electrodes for lithium‐ion batteries.
- 6 November 2023
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 244, 115803
Lithography-free interdigitated electrodes by trench-filling patterning on polymer substrate for Alzheimer's disease detection
- 6 November 2023
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 244, 115803
Lithography-free interdigitated electrodes by trench-filling patterning on polymer substrate for Alzheimer's disease detection
- 1 March 2022
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 355
Lab-in-a-Cup (LiC): An autonomous fluidic device for daily urinalysis using smartphone
- 1 March 2022
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 355
Lab-in-a-Cup (LiC): An autonomous fluidic device for daily urinalysis using smartphone
- 14 August 2018
- Published by Springer Nature in Zeitschrift für angewandte Mathematik und Physik
- Vol. 69 (5) , 113
A note on buoyancy effects in von K $\acute{a}$ a ´ rm $\acute{a}$ a ´ n flow over a rotating disk- 14 August 2018
- Published by Springer Nature in Zeitschrift für angewandte Mathematik und Physik
- Vol. 69 (5) , 113
A note on buoyancy effects in von K $\acute{a}$ a ´ rm $\acute{a}$ a ´ n flow over a rotating disk