Gyeong J. Jin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Gyeong J. Jin has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- M. Mahabubur Rahman
Bio IT Convergence Laboratory, Department of Electronic Convergence Engineering, 20 Kwangwoon-ro, Nowon-gu, Kwang-woon University, Seoul, 01897, Republic of Korea; Nano Genesis Inc., 20 Kwangwoon-ro, Nowon-gu, Seoul, 01897, Republic of Korea
3 shared publications Bappa Sarkar
2 shared publications- Joon Sub Shim
Bio IT Convergence Laboratory, Department of Electronic Convergence Engineering, 20 Kwangwoon-ro, Nowon-gu, Kwang-woon University, Seoul 01897, Republic of Korea
2 shared publications M. Jalal Uddin
2 shared publicationsJoon S. Shim
1 shared publication- M. Jalal Uddin
Department of Electrical and Electronic Engineering, Islamic University, Kushtia-7003, Bangladesh
1 shared publication
Latest Publications
- 17 June 2025
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 393
Wrist-wearable blood flow meter by biomimetically structured conductive PDMS composite
- 17 June 2025
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 393
Wrist-wearable blood flow meter by biomimetically structured conductive PDMS composite
- 6 September 2024
- Published by Royal Society of Chemistry (RSC) in Biomaterials Science
- Vol. 12 (20) , 5203-5214
Development of a highly sensitive CNT-metal graphene hybrid nano-IDA electrochemical biosensor for the diagnosis of Alzheimer's disease
The blood-based detection of Alzheimer's disease (AD) is becoming challenging since the blood–brain barrier (BBB) restricts the direct circulation of AD molecules in the blood, thereby precluding the detection of AD at an early-stage. Herein, we report the development of a novel CNT-metal-porous graphene hybrid (CNT-MGH) nano-interdigitated array (n-IDA) electrochemical 8-well biosensor for the successful early-stage diagnosis of AD from blood. Laser-induced graphene (LIG) technology has been used to fabricate the proposed CNT-MGH n-IDA 8-well sensor. Firstly, the electrochemical characterization (i.e., electrode gap, material composition, etc.) of the proposed sensor was demonstrated by measuring p-aminophenol (PAP) with a limit of detection (LOD) of 0.1 picomole. Subsequently, the CNT-MGH n-IDA 8-well sensor was then used to diagnose AD via novel blood biomarkers p-Tau 217 and p-Tau 181 using an electrochemical enzyme-linked immunosorbent assay (e-ELISA) enzyme by-product PAP. During e-ELISA, the alkaline phosphatase enzyme (IgG-AP) tagged to the detection antibody produced an electroactive ELISA by-product PAP by reacting with the enzyme–substrate 4-aminophenyl phosphate (PAPP). Finally, the CNT-MGH n-IDA 8-well sensor was then used to measure the current generated by the redox reaction via the e-ELISA by-product PAP. While quantified, the proposed CNT-MGH n-IDA 8-well sensor successfully detected p-Tau 217 and p-Tau 181 proteins in blood with LODs of 0.16 pg ml−1 and 0.08 pg ml−1, respectively.
- 6 September 2024
- Published by Royal Society of Chemistry (RSC) in Biomaterials Science
- Vol. 12 (20) , 5203-5214
Development of a highly sensitive CNT-metal graphene hybrid nano-IDA electrochemical biosensor for the diagnosis of Alzheimer's disease
The blood-based detection of Alzheimer's disease (AD) is becoming challenging since the blood–brain barrier (BBB) restricts the direct circulation of AD molecules in the blood, thereby precluding the detection of AD at an early-stage. Herein, we report the development of a novel CNT-metal-porous graphene hybrid (CNT-MGH) nano-interdigitated array (n-IDA) electrochemical 8-well biosensor for the successful early-stage diagnosis of AD from blood. Laser-induced graphene (LIG) technology has been used to fabricate the proposed CNT-MGH n-IDA 8-well sensor. Firstly, the electrochemical characterization (i.e., electrode gap, material composition, etc.) of the proposed sensor was demonstrated by measuring p-aminophenol (PAP) with a limit of detection (LOD) of 0.1 picomole. Subsequently, the CNT-MGH n-IDA 8-well sensor was then used to diagnose AD via novel blood biomarkers p-Tau 217 and p-Tau 181 using an electrochemical enzyme-linked immunosorbent assay (e-ELISA) enzyme by-product PAP. During e-ELISA, the alkaline phosphatase enzyme (IgG-AP) tagged to the detection antibody produced an electroactive ELISA by-product PAP by reacting with the enzyme–substrate 4-aminophenyl phosphate (PAPP). Finally, the CNT-MGH n-IDA 8-well sensor was then used to measure the current generated by the redox reaction via the e-ELISA by-product PAP. While quantified, the proposed CNT-MGH n-IDA 8-well sensor successfully detected p-Tau 217 and p-Tau 181 proteins in blood with LODs of 0.16 pg ml−1 and 0.08 pg ml−1, respectively.
- 6 November 2023
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 244, 115803
Lithography-free interdigitated electrodes by trench-filling patterning on polymer substrate for Alzheimer's disease detection
- 6 November 2023
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 244, 115803
Lithography-free interdigitated electrodes by trench-filling patterning on polymer substrate for Alzheimer's disease detection