Shanshan Long
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Shanshan Long has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
Gongyu Liu
2 shared publicationsXiaogang Yang
2 shared publicationsYongjie Zhao
2 shared publicationsBin Li
1 shared publicationBixuan Wang
1 shared publication- Bo Chen
Department of Mechancial Materials and Manufacturing Engineering Faculty of Science and Engineering University of Nottingham Ningbo China
1 shared publication
Latest Publications
- Open Access
- 15 October 2026
- Published by Wiley in Advanced Science
- p. e78162
Stretchable h‐BN/TPU Fibers for Passive‐Active Dual‐Mode Thermal Management and Wearable Haptic Interfaces
Wearable thermal interfaces require rapid, spatially confined thermal feedback together with mechanical compliance, yet existing passive thermal‐management textiles and active thermal‐haptic devices remain largely separate. Here, a stretchable h ‐BN/TPU composite fiber is developed by coupling microfluidic spinning with non‐solvent‐induced phase separation. Rectangular‐channel confinement aligns hexagonal boron nitride plates within a microporous thermoplastic polyurethane matrix, constructing directional heat‐conduction pathways while preserving large deformation. The optimized 30 wt.% h ‐BN/TPU fiber achieves a dry‐state thermal conductivity of 2.08 and 4.14 W·m −1 ·K −1 under humid conditions, together with 9.67 MPa tensile strength and 422% elongation at break. Pareto‐front analysis identifies the 30 wt.% composition as the thermal‐mechanical knee, arising from the coupled effects of filler orientation, low void fraction, and deformable TPU domains. Woven h ‐BN/TPU fabrics provide passive thermal management, reducing surface temperature by 5.7°C under simulated solar irradiation and maintaining performance after 2000 bending cycles. When integrated into a thermal feedback glove, the fabric enables localized fingertip actuation with a heating rate of +29.55°C·s −1 and a thermal relaxation time of ∼20 s (returning below the warm perception threshold of 35°C). This fiber platform bridges passive heat regulation and active thermal haptics for next‐generation thermally interactive wearables.
- 15 October 2026
- Published by Wiley in Advanced Science
- p. e78162
Open AccessStretchable h‐BN/TPU Fibers for Passive‐Active Dual‐Mode Thermal Management and Wearable Haptic Interfaces
Wearable thermal interfaces require rapid, spatially confined thermal feedback together with mechanical compliance, yet existing passive thermal‐management textiles and active thermal‐haptic devices remain largely separate. Here, a stretchable h ‐BN/TPU composite fiber is developed by coupling microfluidic spinning with non‐solvent‐induced phase separation. Rectangular‐channel confinement aligns hexagonal boron nitride plates within a microporous thermoplastic polyurethane matrix, constructing directional heat‐conduction pathways while preserving large deformation. The optimized 30 wt.% h ‐BN/TPU fiber achieves a dry‐state thermal conductivity of 2.08 and 4.14 W·m −1 ·K −1 under humid conditions, together with 9.67 MPa tensile strength and 422% elongation at break. Pareto‐front analysis identifies the 30 wt.% composition as the thermal‐mechanical knee, arising from the coupled effects of filler orientation, low void fraction, and deformable TPU domains. Woven h ‐BN/TPU fabrics provide passive thermal management, reducing surface temperature by 5.7°C under simulated solar irradiation and maintaining performance after 2000 bending cycles. When integrated into a thermal feedback glove, the fabric enables localized fingertip actuation with a heating rate of +29.55°C·s −1 and a thermal relaxation time of ∼20 s (returning below the warm perception threshold of 35°C). This fiber platform bridges passive heat regulation and active thermal haptics for next‐generation thermally interactive wearables.
- Open Access
- 21 May 2026
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 465
Temperature-self-compensated hydrogel resonant sensor network for high-accuracy, multiplexed, and wireless wound monitoring
- 21 May 2026
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 465
Open AccessTemperature-self-compensated hydrogel resonant sensor network for high-accuracy, multiplexed, and wireless wound monitoring
- Open Access
- 3 March 2026
- Published by IOS Press
- p. 35-42
Optimization Design of a High-Efficiency Cold Plate for Thermal Management Using Additive Manufacturing
Cold plates play a pivotal role in dissipating heat and maintaining the optimal operating temperature of electronic devices. In this paper, we propose an innovative cold-plate design that leverages the geometric freedom offered by additive manufacturing (AM). The design features a bionic configuration composed of tailored micro-fins and porous guide walls. The fins adopt a leaf-vein–inspired pattern with turbo-fan–shaped elements, while curved guide walls channel high-velocity coolant to edge zones. COMSOL simulations demonstrate that the design achieves an average base-plate temperature reduction from 306 K to 301 K as the flow rate increases from 1 L/min to 2 L/min. A 68% improvement in cooling performance over conventional fin-type cold plates was observed, with a mass of just 21g and a thermal resistance as low as 0.0274 K/W. This bio-inspired, lightweight solution adheres to AM fabrication constraints while maintaining low pressure drop and enhanced cooling performance.
- 3 March 2026
- Published by IOS Press
- p. 35-42
Open AccessOptimization Design of a High-Efficiency Cold Plate for Thermal Management Using Additive Manufacturing
Cold plates play a pivotal role in dissipating heat and maintaining the optimal operating temperature of electronic devices. In this paper, we propose an innovative cold-plate design that leverages the geometric freedom offered by additive manufacturing (AM). The design features a bionic configuration composed of tailored micro-fins and porous guide walls. The fins adopt a leaf-vein–inspired pattern with turbo-fan–shaped elements, while curved guide walls channel high-velocity coolant to edge zones. COMSOL simulations demonstrate that the design achieves an average base-plate temperature reduction from 306 K to 301 K as the flow rate increases from 1 L/min to 2 L/min. A 68% improvement in cooling performance over conventional fin-type cold plates was observed, with a mass of just 21g and a thermal resistance as low as 0.0274 K/W. This bio-inspired, lightweight solution adheres to AM fabrication constraints while maintaining low pressure drop and enhanced cooling performance.
- Open Access
- 12 November 2023
- Published by Elsevier in Additive Manufacturing
- Vol. 78
Preventing thermal osteonecrosis through 3D printed ceramic grinding tool
- 12 November 2023
- Published by Elsevier in Additive Manufacturing
- Vol. 78
Open AccessPreventing thermal osteonecrosis through 3D printed ceramic grinding tool
- Open Access
- 9 November 2023
- Published by Elsevier in Chemical Engineering Journal
- Vol. 477
Euler-Euler LES of bubble column bubbly flows by considering sub-grid scale turbulent dispersion effect on modulating bubble transport
- 9 November 2023
- Published by Elsevier in Chemical Engineering Journal
- Vol. 477
Open AccessEuler-Euler LES of bubble column bubbly flows by considering sub-grid scale turbulent dispersion effect on modulating bubble transport
- Open Access
- 1 July 2021
- Published by Frontiers Media SA in Frontiers in Oncology
- Vol. 11
Is Routine Gastroscopy/Colonoscopy Reasonable in Patients With Suspected Ovarian Cancer: A Retrospective Study
Objective: To evaluate the value of routine preoperative gastroscopy/colonoscopy in patients with suspected ovarian cancer for differential diagnosis and judgment of bowel resection.Methods: All women diagnosed with suspected ovarian cancer who underwent gastroscopy/colonoscopy before surgery in our center were retrospectively identified. Gastroscopy/colonoscopy results and clinical pathology, imaging, and surgical findings were analyzed.Results: 389 patients were included. Among them, 40 (including 13 gastric and 9 colonic malignancy) were ovarian metastasis. Compared with imaging, gastrointestinal endoscopy showed no statistical advantage in the specificity and sensitivity (99.4% vs. 99.7%, P=1.0; 55.0% vs. 45.2%, P=0.057; respectively). All patients with gastric/colonic cancer metastasize except for one had indicative imaging or tumor marker abnormalities. Three patients with colonic cancer metastases underwent optimal surgery and alive with no recurrence, the other 19 patients experienced palliative chemotherapy. There is no significant difference in the sensitivity of colonoscopy and imaging in predicting intestinal incision (61.5% vs. 43.8%, P=0.804), whereas the latter had higher specificity (87.8% vs. 74.3%, P=0.001).Conclusions: For patients with suspected ovarian cancer, the incidence of gastrointestinal metastases is low, routine gastroscopy/colonoscopy before treatment is less efficient. Gastroscopy/colonoscopy has limited power to predict the need for gastrointestinal resection before ovarian cancer surgery.
- 1 July 2021
- Published by Frontiers Media SA in Frontiers in Oncology
- Vol. 11
Open AccessIs Routine Gastroscopy/Colonoscopy Reasonable in Patients With Suspected Ovarian Cancer: A Retrospective Study
Objective: To evaluate the value of routine preoperative gastroscopy/colonoscopy in patients with suspected ovarian cancer for differential diagnosis and judgment of bowel resection.Methods: All women diagnosed with suspected ovarian cancer who underwent gastroscopy/colonoscopy before surgery in our center were retrospectively identified. Gastroscopy/colonoscopy results and clinical pathology, imaging, and surgical findings were analyzed.Results: 389 patients were included. Among them, 40 (including 13 gastric and 9 colonic malignancy) were ovarian metastasis. Compared with imaging, gastrointestinal endoscopy showed no statistical advantage in the specificity and sensitivity (99.4% vs. 99.7%, P=1.0; 55.0% vs. 45.2%, P=0.057; respectively). All patients with gastric/colonic cancer metastasize except for one had indicative imaging or tumor marker abnormalities. Three patients with colonic cancer metastases underwent optimal surgery and alive with no recurrence, the other 19 patients experienced palliative chemotherapy. There is no significant difference in the sensitivity of colonoscopy and imaging in predicting intestinal incision (61.5% vs. 43.8%, P=0.804), whereas the latter had higher specificity (87.8% vs. 74.3%, P=0.001).Conclusions: For patients with suspected ovarian cancer, the incidence of gastrointestinal metastases is low, routine gastroscopy/colonoscopy before treatment is less efficient. Gastroscopy/colonoscopy has limited power to predict the need for gastrointestinal resection before ovarian cancer surgery.