James W. Schmidt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
James W. Schmidt has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Michael R. Moldover
National Institute of Standards and Technology 2
2 shared publications - Andrew D. Koffman
National Institute of Standards and Technology, 100 Bureau Drive, Gaithersburg, MD, United States of America
1 shared publication B E Welch
Div. of Thermophysics, Nat. Inst. of Stand. & Technol., Gaithersburg, MD, USA
1 shared publication- Bryan C. Waltrip
National Institute of Standards and Technology, Gaithersburg, MD, USA
1 shared publication C D Ehrlich
Div. of Thermophysics, Nat. Inst. of Stand. & Technol., Gaithersburg, MD, USA
1 shared publication- Christopher W Meyer
National Institute for Standards and Technology (NIST), Bldg. 221, Rm. B131. 100 Bureau Dr. Gaithersburg, MD 20899, United States of America
1 shared publication
Latest Publications
- Open Access
- 20 November 2023
- Published by IOP Publishing in Metrologia
- Vol. 60 (6) , 065014
A high accuracy reference facility for ongoing comparisons of CO2 in air standards
The design, performance characteristics and validation of a next generation reference facility for carbon dioxide (CO2) in air standards based on manometry is presented. Novel attributes of the facility include automated operation, avoidance of significant pressure corrections for measurements on extracted CO2, fully characterized trapping efficiencies, and reduced measurement uncertainty. Improvements in system performance have been achieved using specific materials, notably Silconert®-treated stainless-steel, providing increased mechanical stability whilst minimizing carbon dioxide adsorption on surfaces, and avoiding use of elastomer O-rings, which would lead to losses of CO2. Full automation of the cryogenic extraction process of CO2 from air has been achieved, avoiding any manual intervention within the temperature stabilized section of the facility, and allowed full characterization and correction for trapping efficiencies and trace water measurement. The facility has been validated across the CO2 in air amount fraction range of (380–800) µmol mol−1 using standards with values traceable to the reference value of the CCQM−K120 (2018) comparison. It was demonstrated to operate with a standard measurement uncertainty of 0.09 µmol mol−1 at 400 µmol mol−1. The automation allows five measurement results per day to be produced with a typical standard deviation of the mean at or below 0.02 µmol mol−1. The facility will be used as a stable reference in the future BIPM.QM−K2 ongoing comparison, to compare consistency of amount fraction values in different CO2 in air standards. The CO2 amount fraction in two ensembles of nine BIPM standards covering the same range will also be measured with the facility to provide their SI-traceable values, and further monitored on a longer time scale. Each ensemble will constitute a CO2 in air scale to be compared with other available scales such as WMO.CO2.X2019 through the BIPM.QM−K5 comparison.
- 20 November 2023
- Published by IOP Publishing in Metrologia
- Vol. 60 (6) , 065014
Open AccessA high accuracy reference facility for ongoing comparisons of CO2 in air standards
The design, performance characteristics and validation of a next generation reference facility for carbon dioxide (CO2) in air standards based on manometry is presented. Novel attributes of the facility include automated operation, avoidance of significant pressure corrections for measurements on extracted CO2, fully characterized trapping efficiencies, and reduced measurement uncertainty. Improvements in system performance have been achieved using specific materials, notably Silconert®-treated stainless-steel, providing increased mechanical stability whilst minimizing carbon dioxide adsorption on surfaces, and avoiding use of elastomer O-rings, which would lead to losses of CO2. Full automation of the cryogenic extraction process of CO2 from air has been achieved, avoiding any manual intervention within the temperature stabilized section of the facility, and allowed full characterization and correction for trapping efficiencies and trace water measurement. The facility has been validated across the CO2 in air amount fraction range of (380–800) µmol mol−1 using standards with values traceable to the reference value of the CCQM−K120 (2018) comparison. It was demonstrated to operate with a standard measurement uncertainty of 0.09 µmol mol−1 at 400 µmol mol−1. The automation allows five measurement results per day to be produced with a typical standard deviation of the mean at or below 0.02 µmol mol−1. The facility will be used as a stable reference in the future BIPM.QM−K2 ongoing comparison, to compare consistency of amount fraction values in different CO2 in air standards. The CO2 amount fraction in two ensembles of nine BIPM standards covering the same range will also be measured with the facility to provide their SI-traceable values, and further monitored on a longer time scale. Each ensemble will constitute a CO2 in air scale to be compared with other available scales such as WMO.CO2.X2019 through the BIPM.QM−K5 comparison.
- Open Access
- 6 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-10
Measurement of the Frequency Dependence of Four Terminal-Pair Air Capacitors With a Vector Network Analyzer
Four terminal-pair air capacitors are important transfer standards to calibrate LCR meters up to a frequency of 10 MHz. We report a simple and new method to obtain the frequency dependence of the four terminal-pair capacitance of these standards using a four-channel vector network analyzer (VNA). The frequency dependence of the capacitance of an air capacitor and its uncertainty can be obtained from a single set of measurements without changing connections between the standard and the VNA, as has been the case in previously published work. The calculation of the frequency dependency is straightforward and model-independent. Nevertheless, an elementary model is provided to explain the observed frequency dependence. This article allows every laboratory with a four-channel VNA to measure the frequency dependence of these capacitors. Hence, a significant shortening of the traceability chain is achieved.
- 6 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-10
Open AccessMeasurement of the Frequency Dependence of Four Terminal-Pair Air Capacitors With a Vector Network Analyzer
Four terminal-pair air capacitors are important transfer standards to calibrate LCR meters up to a frequency of 10 MHz. We report a simple and new method to obtain the frequency dependence of the four terminal-pair capacitance of these standards using a four-channel vector network analyzer (VNA). The frequency dependence of the capacitance of an air capacitor and its uncertainty can be obtained from a single set of measurements without changing connections between the standard and the VNA, as has been the case in previously published work. The calculation of the frequency dependency is straightforward and model-independent. Nevertheless, an elementary model is provided to explain the observed frequency dependence. This article allows every laboratory with a four-channel VNA to measure the frequency dependence of these capacitors. Hence, a significant shortening of the traceability chain is achieved.
- 25 September 2008
- Published by American Physical Society (APS) in Physical Review A
- Vol. 78 (3) , 032522
Electric and magnetic susceptibilities of gaseous oxygen: Present data and modern theory compared
We used a cross capacitor to measure the relative dielectric permittivity of at 273, 293, and and at pressures up to . Simultaneously we measured oxygen’s complex refractive index using a quasispherical cavity resonator at frequencies between 2.4 and . The combined results from these measurements determine oxygen’s frequency-dependent, relative magnetic permeability with an uncertainty of less than 1% of at pressures above . Regression of these data to a model for oxygen’s impact—broadened microwave spectrum allowed us to determine two quantities that are, in principle, amenable to calculation: the molar magnetic susceptibility in the limits of zero pressure and zero frequency and the second magnetic virial coefficient . With oxygen’s electronic factor constrained to (the value known from laser magnetic resonance, EPR, and molecular beam experiments) we obtained and . The result for is consistent with a recent ab initio calculation . Our measurements of oxygen’s magnetic susceptibility are the first made relative to the susceptibility of helium calculated ab initio. All previous measurements were made relative to the diamagnetic susceptibility of water. These previous measurements, published in 1943 or earlier, span the wider range . Our measurements of determine the static molecular dielectric polarizability of oxygen: , which deviates by and from two recent ab initio calculations.- 25 September 2008
- Published by American Physical Society (APS) in Physical Review A
- Vol. 78 (3) , 032522
Electric and magnetic susceptibilities of gaseous oxygen: Present data and modern theory compared
We used a cross capacitor to measure the relative dielectric permittivity of at 273, 293, and and at pressures up to . Simultaneously we measured oxygen’s complex refractive index using a quasispherical cavity resonator at frequencies between 2.4 and . The combined results from these measurements determine oxygen’s frequency-dependent, relative magnetic permeability with an uncertainty of less than 1% of at pressures above . Regression of these data to a model for oxygen’s impact—broadened microwave spectrum allowed us to determine two quantities that are, in principle, amenable to calculation: the molar magnetic susceptibility in the limits of zero pressure and zero frequency and the second magnetic virial coefficient . With oxygen’s electronic factor constrained to (the value known from laser magnetic resonance, EPR, and molecular beam experiments) we obtained and . The result for is consistent with a recent ab initio calculation . Our measurements of oxygen’s magnetic susceptibility are the first made relative to the susceptibility of helium calculated ab initio. All previous measurements were made relative to the diamagnetic susceptibility of water. These previous measurements, published in 1943 or earlier, span the wider range . Our measurements of determine the static molecular dielectric polarizability of oxygen: , which deviates by and from two recent ab initio calculations.- Open Access
- 1 March 2003
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 108 (2) , 135-45
A primary dead-weight tester for pressures (0.05-1.0) MPa
Recent advances in technology on two fronts, 1) the fabrication of large-diameter pistons and cylinders with good geometry, and 2) the ability to measure the dimensions of these components with high accuracy, have allowed dead-weight testers at the National Institute of Standards and Technology (NIST) to generate pressures that approach total relative uncertainties previously obtained only by manometers. This paper describes a 35 mm diameter piston/cylinder assembly (known within NIST as PG-39) that serves as a pressure standard in which both the piston and the cylinder have been accurately dimensioned by Physikalisch Technische Bundesanstalt (PTB). Both artifacts (piston and cylinder) appeared to be round within ±30 nm and straight within ±100 nm over a substantial fraction of their heights. Based on the diameters at 20 °C provided by PTB (±15 nm) and on the good geometry of the artifact, the relative uncertainties for the effective area were estimated to be about 2.2 × 10(-6) (1σ).
- 1 March 2003
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 108 (2) , 135-45
Open AccessA primary dead-weight tester for pressures (0.05-1.0) MPa
Recent advances in technology on two fronts, 1) the fabrication of large-diameter pistons and cylinders with good geometry, and 2) the ability to measure the dimensions of these components with high accuracy, have allowed dead-weight testers at the National Institute of Standards and Technology (NIST) to generate pressures that approach total relative uncertainties previously obtained only by manometers. This paper describes a 35 mm diameter piston/cylinder assembly (known within NIST as PG-39) that serves as a pressure standard in which both the piston and the cylinder have been accurately dimensioned by Physikalisch Technische Bundesanstalt (PTB). Both artifacts (piston and cylinder) appeared to be round within ±30 nm and straight within ±100 nm over a substantial fraction of their heights. Based on the diameters at 20 °C provided by PTB (±15 nm) and on the good geometry of the artifact, the relative uncertainties for the effective area were estimated to be about 2.2 × 10(-6) (1σ).
- 1 May 1996
- Published by Elsevier in International Journal of Refrigeration
- Vol. 19 (4) , 285-294
Thermodynamic properties of CHF2CF2CH2F, 1,1,2,2,3-pentafluoropropane
- 1 May 1996
- Published by Elsevier in International Journal of Refrigeration
- Vol. 19 (4) , 285-294
Thermodynamic properties of CHF2CF2CH2F, 1,1,2,2,3-pentafluoropropane
- 1 January 1993
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 4 (1) , 26-34
Operational mode and gas species effects on rotational drag in pneumatic dead weight pressure gauges
Rotational dissipation in a low-pressure pneumatic dead weight piston gauge has been measured for four gases: He, H2, N2 and SF6. Significant differences in the rotational dissipation were observed between the four gas species. Even larger differences were observed between two operational modes (gauge and absolute). The measured results are interpreted by a model for the rotational dissipation due to the gas in the annular region between the piston and cylinder. Good agreement was found between the measured and modelled results for all four species with essentially no adjustable parameters.
- 1 January 1993
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 4 (1) , 26-34
Operational mode and gas species effects on rotational drag in pneumatic dead weight pressure gauges
Rotational dissipation in a low-pressure pneumatic dead weight piston gauge has been measured for four gases: He, H2, N2 and SF6. Significant differences in the rotational dissipation were observed between the four gas species. Even larger differences were observed between two operational modes (gauge and absolute). The measured results are interpreted by a model for the rotational dissipation due to the gas in the annular region between the piston and cylinder. Good agreement was found between the measured and modelled results for all four species with essentially no adjustable parameters.