Sabir Baghirov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sabir Baghirov has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Gregory Kozhushko
National University «Yuri Kondratyuk Poltava Polytechnic
2 shared publications - Svitlana Kyslytsia
National University «Yuri Kondratyuk Poltava Polytechnic
2 shared publications - Svitlana Shpak
State Enterprise «Poltava Regional Research and Technical Center of Standardization, Metrology and Certification
2 shared publications Azerbaijan Technical University
1 shared publication- Demyd V. Pekur
Інститут фізики напівпровідників імені В. Є. Лашкарьова НАН України
1 shared publication Iuliia Basova
Poltava State Agrarian University
1 shared publication
Latest Publications
- Open Access
- 30 December 2025
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 6 (10 (138)) , 48-59
Assessment of energy efficiency and environmental performance of led light sources by the ecodesign methods
The object of the study is the processes and factors that determine the energy efficiency and environmental friendliness of LED light sources and contribute to reducing negative impacts on the environment and human health. The work investigated the levels of energy efficiency and environmental friendliness of commercial samples of LED luminaires for compliance with the requirements of the EU Commission Regulations on Energy Labeling No. 2019/2015 and on Ecodesign No. 2019/2020. The network efficiency coefficient hTM (lm/W) was taken as the energy efficiency criterion. The main environmental friendliness criteria: the limit level of flicker luminance PstLM and the visibility of the stroboscopic effect SVM are established by the EU Commission Regulation No. 2019/2020; the limit level of blue light hazard should not exceed the risk group RG1 according to EN 62471:2018; the limit levels of the Unified Glare Rating UGR according to ISO 8995-1:2025. LED luminaires using high-power LEDs have a hTM coefficient of 135–170 lm/W and comply with energy efficiency classes D and C according to Commission Regulation EU No. 2019/2015. The hTM coefficient of luminaires with low-power LEDs is 100 lm/W, energy efficiency class F. Luminaires with low-power LEDs correspond to the RG0 risk group in terms of blue light safety, and luminaires with high-power LEDs correspond to the RG1 risk group. All tested luminaires meet the requirements of Commission Regulation EU No. 2019/2020 in terms of flicker luminance and visibility of the stroboscopic effect (PstLM < 1, SVM < 0.4). Light exceeding the established limit values for these indicators has a negative impact on health and can be classified as light pollution. Light sources have the greatest impact on the environment as a result of the consumption of electrical energy
- 30 December 2025
- Published by Private Company Technology Center in Eastern-European Journal of Enterprise Technologies
- Vol. 6 (10 (138)) , 48-59
Open AccessAssessment of energy efficiency and environmental performance of led light sources by the ecodesign methods
The object of the study is the processes and factors that determine the energy efficiency and environmental friendliness of LED light sources and contribute to reducing negative impacts on the environment and human health. The work investigated the levels of energy efficiency and environmental friendliness of commercial samples of LED luminaires for compliance with the requirements of the EU Commission Regulations on Energy Labeling No. 2019/2015 and on Ecodesign No. 2019/2020. The network efficiency coefficient hTM (lm/W) was taken as the energy efficiency criterion. The main environmental friendliness criteria: the limit level of flicker luminance PstLM and the visibility of the stroboscopic effect SVM are established by the EU Commission Regulation No. 2019/2020; the limit level of blue light hazard should not exceed the risk group RG1 according to EN 62471:2018; the limit levels of the Unified Glare Rating UGR according to ISO 8995-1:2025. LED luminaires using high-power LEDs have a hTM coefficient of 135–170 lm/W and comply with energy efficiency classes D and C according to Commission Regulation EU No. 2019/2015. The hTM coefficient of luminaires with low-power LEDs is 100 lm/W, energy efficiency class F. Luminaires with low-power LEDs correspond to the RG0 risk group in terms of blue light safety, and luminaires with high-power LEDs correspond to the RG1 risk group. All tested luminaires meet the requirements of Commission Regulation EU No. 2019/2020 in terms of flicker luminance and visibility of the stroboscopic effect (PstLM < 1, SVM < 0.4). Light exceeding the established limit values for these indicators has a negative impact on health and can be classified as light pollution. Light sources have the greatest impact on the environment as a result of the consumption of electrical energy
- Open Access
- 31 July 2025
- Published by OU Scientific Route in EUREKA: Physics and Engineering
- No. 4,p. 180-188
Photobiological safety of household led projectors
The article discusses the influence of LED projector radiation indicators on photobiological and thermal hazards to the human body. The obtained results of the levels of visible radiation of the optical spectrum and the thermal effect of image spotlights intended for use in domestic conditions are presented. The dependences of the energy brightness on the harmfulness function of the spectrum of visible radiation, on the ratio of the field of view angle γ and the solid angle of the light source α, as well as on the measurement distance have been established. It has been shown that when the distance from the observer to the projector increases by more than 1.25 m, the radiation from projectors does not pose any danger and corresponds to the risk group RG0. At a distance of up to one meter from the projector (the range where the degree of visible radiation of the optical spectrum is regulated), the type of light source studied is classified as low hazard RG1 and meets the established requirements of the standard. When the observation range is up to 0.3 m, the level of influence of the danger of visible radiation the optical spectrum increases to the second category. At a distance of 1 m, the luminance LR is almost three orders of magnitude lower than the limit value, and at a distance of 0.5 m, LR is also significantly lower than the limit values. For the closest distance of 0.2 m, the LR level is below the LR limit values for the average risk group RG2 and the level of thermal hazard created by optical radiation with wavelengths of 380‒1400 nm does not exceed the norm for the studied projectors. Conclusions are drawn about the compliance of the studied low‒ power image projectors with the blue light safety conditions established by the international standard
- 31 July 2025
- Published by OU Scientific Route in EUREKA: Physics and Engineering
- No. 4,p. 180-188
Open AccessPhotobiological safety of household led projectors
The article discusses the influence of LED projector radiation indicators on photobiological and thermal hazards to the human body. The obtained results of the levels of visible radiation of the optical spectrum and the thermal effect of image spotlights intended for use in domestic conditions are presented. The dependences of the energy brightness on the harmfulness function of the spectrum of visible radiation, on the ratio of the field of view angle γ and the solid angle of the light source α, as well as on the measurement distance have been established. It has been shown that when the distance from the observer to the projector increases by more than 1.25 m, the radiation from projectors does not pose any danger and corresponds to the risk group RG0. At a distance of up to one meter from the projector (the range where the degree of visible radiation of the optical spectrum is regulated), the type of light source studied is classified as low hazard RG1 and meets the established requirements of the standard. When the observation range is up to 0.3 m, the level of influence of the danger of visible radiation the optical spectrum increases to the second category. At a distance of 1 m, the luminance LR is almost three orders of magnitude lower than the limit value, and at a distance of 0.5 m, LR is also significantly lower than the limit values. For the closest distance of 0.2 m, the LR level is below the LR limit values for the average risk group RG2 and the level of thermal hazard created by optical radiation with wavelengths of 380‒1400 nm does not exceed the norm for the studied projectors. Conclusions are drawn about the compliance of the studied low‒ power image projectors with the blue light safety conditions established by the international standard
- 1 January 2023
- Published by Azerbaijan Technical University in Elmi Əsərlər
- Vol. 11 (1) , 52-55
İŞIQLANDIRMA AVADANLIQLARINDA ELEKTRİK ENERJİSİNӘ QӘNAӘT EDİLMӘSİ KONSEPSİYASININ İŞLӘNİLMӘSİ
İşıqlandırma avadanlıqlarında enerji effektivliyinin yüksәldilmәsi hәm enerji ehtiyatları sәrfiyyatının, hәm dә atmosferdә zәhәrli qazların konsentrasiyasının azalması problemlәrini hәll edir. Mәqalәdә enerjiyә qәnaәtcil işıqlandırmanın inkişafından ötrü mövcud problemlәr araşdırılmış vә onların hәlli konsepsiyası işlәnilmişdir. Qeyd olunmuşdur ki, texniki problemlәrlә bәrabәr qanunvericilik aktlarının qәbul edilmәsi, iqtisadi vә tәşkilatçılıq mәsәlәlәri kompleks şәkildә hәll edilmәlidir.
- 1 January 2023
- Published by Azerbaijan Technical University in Elmi Əsərlər
- Vol. 11 (1) , 52-55
İŞIQLANDIRMA AVADANLIQLARINDA ELEKTRİK ENERJİSİNӘ QӘNAӘT EDİLMӘSİ KONSEPSİYASININ İŞLӘNİLMӘSİ
İşıqlandırma avadanlıqlarında enerji effektivliyinin yüksәldilmәsi hәm enerji ehtiyatları sәrfiyyatının, hәm dә atmosferdә zәhәrli qazların konsentrasiyasının azalması problemlәrini hәll edir. Mәqalәdә enerjiyә qәnaәtcil işıqlandırmanın inkişafından ötrü mövcud problemlәr araşdırılmış vә onların hәlli konsepsiyası işlәnilmişdir. Qeyd olunmuşdur ki, texniki problemlәrlә bәrabәr qanunvericilik aktlarının qәbul edilmәsi, iqtisadi vә tәşkilatçılıq mәsәlәlәri kompleks şәkildә hәll edilmәlidir.
- Open Access
- 30 May 2022
- Published by Ukrainian Research and Design Institute of Building Materials and Products in Sworld-Us Conference proceedings
- No. usc31-00,p. 11-18
ON THE NECESSITY OF DISPOSAL AND REUSE OF LED LIGHT SOURCE MATERIALS AFTER THEIR END OF USE
The paper considers the problems of recycling and reuse of materials of LED light sources after the end of their service life. The emphasis is on the importance of the transition to a circular economy and eco-design as means of sustainable development. Th
- 30 May 2022
- Published by Ukrainian Research and Design Institute of Building Materials and Products in Sworld-Us Conference proceedings
- No. usc31-00,p. 11-18
Open AccessON THE NECESSITY OF DISPOSAL AND REUSE OF LED LIGHT SOURCE MATERIALS AFTER THEIR END OF USE
The paper considers the problems of recycling and reuse of materials of LED light sources after the end of their service life. The emphasis is on the importance of the transition to a circular economy and eco-design as means of sustainable development. Th