Yuan Luo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yuan Luo has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Weiping Lin
Sichuan University
4 shared publications - Yanxi Wang
Key Laboratory of Radiation Physics and Technology, Ministry of Education, Institute of Nuclear Science and Technology, Sichuan University, Chengdu 610064, China
3 shared publications - Long Ma
Key Laboratory of Radiation Physics and Technology of the Ministry of Education, Institute of Nuclear Science and Technology, Sichuan University, Chengdu, China
2 shared publications - Y. F. Qu
Southwestern Inst Phys, Chengdu 610064, Peoples R China
2 shared publications D. Xie
1 shared publicationDehao Xie
Key Laboratory of Radiation Physics and Technology, Ministry of Education, Institute of Nuclear Science and Technology, Sichuan University, Chengdu 610064, China
1 shared publication
Latest Publications
- 1 March 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (03) , P03030
Calibration of an E//B Neutral Particle Analyzer and novel data analysis for its first experiment on the HL-3 tokamak
An E parallel B type neutral particle analyzer (E//B NPA) with mass and energy resolution has been developed and successfully conducted its first experiment on the HL-3 tokamak. The mass and energy calibration of the E//B NPA was performed using H + and D + beams on a 300 kV ion accelerator. Results indicate that the E//B NPA is capable of detecting H + in the energy range of 27.4 keV to 462.4 keV and D + in the range of 15.6 keV to 233.4 keV, with an energy resolution of less than 10%. Thanks to background resolving ability of LYSO+SiPM detector module, a novel method was employed for data analysis during the first experiment conducted on the HL-3 tokamak. Background measurements revealed that secondary gamma rays produced from the interaction between neutrons from deuteron fusion reactions and materials surrounding the detector modules were the primary source of background radiation. Based on this background study, the net spectrum of each detector was obtained by subtracting the evaluated background component according to the shape of the background spectrum. Time tracing of neutral particles was obtained by subtracting the evaluated background from the measured neutron flux. Ultimately, neutral energy spectra of H and D are obtained. These results confirm that the E//B NPA is reliably applied for the fast ion detection and neutral flux measurement on the HL-3 tokamak.
- 1 March 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (03) , P03030
Calibration of an E//B Neutral Particle Analyzer and novel data analysis for its first experiment on the HL-3 tokamak
An E parallel B type neutral particle analyzer (E//B NPA) with mass and energy resolution has been developed and successfully conducted its first experiment on the HL-3 tokamak. The mass and energy calibration of the E//B NPA was performed using H + and D + beams on a 300 kV ion accelerator. Results indicate that the E//B NPA is capable of detecting H + in the energy range of 27.4 keV to 462.4 keV and D + in the range of 15.6 keV to 233.4 keV, with an energy resolution of less than 10%. Thanks to background resolving ability of LYSO+SiPM detector module, a novel method was employed for data analysis during the first experiment conducted on the HL-3 tokamak. Background measurements revealed that secondary gamma rays produced from the interaction between neutrons from deuteron fusion reactions and materials surrounding the detector modules were the primary source of background radiation. Based on this background study, the net spectrum of each detector was obtained by subtracting the evaluated background component according to the shape of the background spectrum. Time tracing of neutral particles was obtained by subtracting the evaluated background from the measured neutron flux. Ultimately, neutral energy spectra of H and D are obtained. These results confirm that the E//B NPA is reliably applied for the fast ion detection and neutral flux measurement on the HL-3 tokamak.
- 2 December 2023
- Published by Elsevier in Fusion Engineering and Design
- Vol. 198
A simulation study of a collimating shield structure in a vertical neutron camera on HL-3
- 2 December 2023
- Published by Elsevier in Fusion Engineering and Design
- Vol. 198
A simulation study of a collimating shield structure in a vertical neutron camera on HL-3
- 22 November 2023
- Published by Elsevier in Fusion Engineering and Design
- Vol. 197
Development and validation of the E parallel B type neutral particle analyzer on the HL-3 tokamak
- 22 November 2023
- Published by Elsevier in Fusion Engineering and Design
- Vol. 197
Development and validation of the E parallel B type neutral particle analyzer on the HL-3 tokamak