HQHui Qiu

Hui Qiu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hui Qiu has a total of 26 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A High Accuracy and Ultra-Energy-Efficient Zero-Shot-Retraining Seizure Detection Processor

    by Jiahao Liu, Xiao Liu, Xu Wang, Ziyi Xie, Chaozheng Guo, Zirui Zhong, Jiajing Fan, Hui Qiu, Yiming Xu, Huajing Qin, et al.

    Recently, wearable devices integrating seizure detection processors have been developed to detect seizures in real time for alerting, recording, or in-device treatment purposes. High accuracy and low energy consumption are paramount for seizure detection processors. Many existing seizure detection processors are able to achieve high accuracy when large amounts of seizure data from the test patient is available for the training, which requires the test patient to undergo time-consuming and costly hospitalization due to the low occurrence of seizure data and therefore is impractical. This work proposes a high-accuracy and ultra-energy-efficient zero-shot-retraining seizure detection processor that requires no seizure data from the test patient for retraining. Two novel techniques have been proposed to improve the accuracy and reduce energy consumption, including a hybrid-feature-driven adaptive processing architecture with on-chip learning for improving the accuracy against inter-patient variation and reduce the classification energy consumption and a learning-based adaptive channel selection technique to identify the redundant electroencephalogram (EEG) channels for further energy saving while maintaining high accuracy. The proposed seizure detection processor has been implemented and fabricated in 55-nm CMOS technology. It demonstrates high sensitivity (i.e., 100% event-based sensitivity) and specificity (i.e., 94%) with extremely low energy consumption (i.e., $0.07~\mu $ J/classification and $0.1~\mu $ J/learning) while requiring no seizure data from the test patient for retraining, outperforming the state-of-the-art designs.


  • An Ultra-Low Power Reconfigurable Biomedical AI Processor With Adaptive Learning for Versatile Wearable Intelligent Health Monitoring

    by Jiahao Liu, Jiajing Fan, Zirui Zhong, Hui Qiu, Jianbiao Xiao, Yong Zhou, Zhen Zhu, Guanghai Dai, Ning Wang, Qingsong Liu, et al.

    Wearable intelligent health monitoring devices with on-device biomedical AI processor can be used to detect the abnormity in users' biomedical signals (e.g., ECG arrythmia classification, EEG-based seizure detection). This requires ultra-low power and reconfigurable biomedical AI processor to support battery-supplied wearable devices and versatile intelligent health monitoring applications while achieving high classification accuracy. However, existing designs have issues in meeting one or more of the above requirements. In this work, a reconfigurable biomedical AI processor (named BioAIP) is proposed, mainly featuring: 1) a reconfigurable biomedical AI processing architecture to support versatile biomedical AI processing. 2) an event-driven biomedical AI processing architecture with approximate data compression to reduce the power consumption. 3) an AI-based adaptive-learning architecture to address patient-to-patient variation and improve the classification accuracy. The design has been implemented and fabricated using a 65nm CMOS process technology. It has been demonstrated with three typical biomedical AI applications, including ECG arrythmia classification, EEG-based seizure detection and EMG-based hand gesture recognition. Compared with the state-of-the-art designs optimized for single biomedical AI tasks, the BioAIP achieves the lowest energy per classification among the designs with similar accuracy, while supporting various biomedical AI tasks.