Natalie Taylor
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Natalie Taylor has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Robert M. Gifford
University of Edinburgh School of Neurological and Cardiovascular Sciences, Queen’s Medical Research Institute , Edinburgh EH16 4TJ
6 shared publications A Carroll
Royal Centre for Defence Medicine, Birmingham, UK
2 shared publications- Stefano Capella
Institute of Naval Medicine, Royal Navy
2 shared publications A Tsanas
Usher Institute, Edinburgh Medical School, University of Edinburgh, Edinburgh, UK
1 shared publication- Adrian J. Wilson
Department of Research and Development, University Hospitals Coventry and Warwickshire NHS Trust, Coventry, England, UK
1 shared publication Alexander Heuser
GEOMAR Helmholtz Centre for Ocean Research Kiel
1 shared publication
Latest Publications
- 1 December 2025
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 139 (6) , 1687-1693
Bone calcium balance following an Antarctic expedition
This study provides new insight into bone calcium balance in extreme environments using a novel and noninvasive approach of naturally occurring calcium isotopes. Decreases in fat mass and body mass provide evidence that participants were in energy deficit, but most reproductive and thyroid hormones remained stable. Whole-body and regional aBMD decreased. Group-level urine δ 44/42 Ca-a marker of bone calcium balance did not change across the expedition, but individuals displayed significant variability in responses.
- 1 December 2025
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 139 (6) , 1687-1693
Bone calcium balance following an Antarctic expedition
This study provides new insight into bone calcium balance in extreme environments using a novel and noninvasive approach of naturally occurring calcium isotopes. Decreases in fat mass and body mass provide evidence that participants were in energy deficit, but most reproductive and thyroid hormones remained stable. Whole-body and regional aBMD decreased. Group-level urine δ 44/42 Ca-a marker of bone calcium balance did not change across the expedition, but individuals displayed significant variability in responses.
- 14 November 2025
- Published by Taylor & Francis in Journal of Medical Engineering & Technology
- Vol. 50 (2) , 111-128
What makes wearable devices usable? Lessons learned from a 47-day Antarctic ski expedition to the South Pole (INSPIRE22)
Wearable devices are used increasingly within the medical world, ranging from monitoring for head trauma to screening for heat injuries. Understanding what makes these devices tolerable to the end user in remote hostile environments is crucial for research, military, and humanitarian medicine, with broader translational implications. This opportunistic qualitative study trialled five different forms of wearable devices on the Interdisciplinary South Pole Innovation and Research Expedition 2022 (INSPIRE 22), an expedition which skied from the edge of the Antarctic land mass to the South Pole. It also examined the feasibility of near-real time analysis of wearable data from a hostile environment remotely from the UK. Key findings highlighted that usability of wearable devices was impacted by human-device interface factors (comfort, user buy in, and charging) and device resource requirements (power, data, and storage space on a personal mobile phone). Users required a more positive than negative aspects to maintain device interaction. Near-real-time data analysis of wearable technology from extreme environments is feasible but only on a small inconsistent scale due to limited connectivity. Reliable internet access, broader bandwidth, and better user access to data are essential to achieve meaningful health and performance insights for the individual and wider organisations.
- 14 November 2025
- Published by Taylor & Francis in Journal of Medical Engineering & Technology
- Vol. 50 (2) , 111-128
What makes wearable devices usable? Lessons learned from a 47-day Antarctic ski expedition to the South Pole (INSPIRE22)
Wearable devices are used increasingly within the medical world, ranging from monitoring for head trauma to screening for heat injuries. Understanding what makes these devices tolerable to the end user in remote hostile environments is crucial for research, military, and humanitarian medicine, with broader translational implications. This opportunistic qualitative study trialled five different forms of wearable devices on the Interdisciplinary South Pole Innovation and Research Expedition 2022 (INSPIRE 22), an expedition which skied from the edge of the Antarctic land mass to the South Pole. It also examined the feasibility of near-real time analysis of wearable data from a hostile environment remotely from the UK. Key findings highlighted that usability of wearable devices was impacted by human-device interface factors (comfort, user buy in, and charging) and device resource requirements (power, data, and storage space on a personal mobile phone). Users required a more positive than negative aspects to maintain device interaction. Near-real-time data analysis of wearable technology from extreme environments is feasible but only on a small inconsistent scale due to limited connectivity. Reliable internet access, broader bandwidth, and better user access to data are essential to achieve meaningful health and performance insights for the individual and wider organisations.
- Open Access
- 22 May 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-11
Preserved circadian variation in cortisol and androgens during a ski traverse of Antarctica in summer
Antarctic expeditions present extreme physiological challenges due to cold temperatures, high physical exertion, and 24-hour daylight. This observational study evaluated endocrine adaptation in nine participants (six men, three women) during a 47-day, 1,000 km unassisted ski traverse. Detailed salivary sampling was conducted before, during and after the expedition, corroborated by blood and hair sampling before and after the expedition. Cortisol, testosterone, and androstenedione were measured using mass spectrometry, and thyroid hormones via immunoassay. Diurnal cortisol, androstenedione and testosterone variation was preserved, while the morning cortisol increased during the expedition, suggesting that exercise demands overshadow the effects of continuous daylight in controlling hypothalamic-pituitary-adrenal and gonadal axis function. Morning testosterone decreased during the expedition, with a greater effect seen among men. No significant changes were seen in blood or hair steroid hormones. Gonadotropins in women indicated central suppression pre-expedition, normalizing post-expedition. Thyroid-stimulating hormone levels increased post-expedition without significant changes in free T3 or T4, consistent with mild polar T3 syndrome. These findings highlight the adaptability of hypothalamic-pituitary function to combined stressors of exercise, energy deficit, and cold. This is the first study to capture in situ endocrine responses during an Antarctic traverse, advancing our understanding of human adaptation in extreme environments.
- 22 May 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-11
Open AccessPreserved circadian variation in cortisol and androgens during a ski traverse of Antarctica in summer
Antarctic expeditions present extreme physiological challenges due to cold temperatures, high physical exertion, and 24-hour daylight. This observational study evaluated endocrine adaptation in nine participants (six men, three women) during a 47-day, 1,000 km unassisted ski traverse. Detailed salivary sampling was conducted before, during and after the expedition, corroborated by blood and hair sampling before and after the expedition. Cortisol, testosterone, and androstenedione were measured using mass spectrometry, and thyroid hormones via immunoassay. Diurnal cortisol, androstenedione and testosterone variation was preserved, while the morning cortisol increased during the expedition, suggesting that exercise demands overshadow the effects of continuous daylight in controlling hypothalamic-pituitary-adrenal and gonadal axis function. Morning testosterone decreased during the expedition, with a greater effect seen among men. No significant changes were seen in blood or hair steroid hormones. Gonadotropins in women indicated central suppression pre-expedition, normalizing post-expedition. Thyroid-stimulating hormone levels increased post-expedition without significant changes in free T3 or T4, consistent with mild polar T3 syndrome. These findings highlight the adaptability of hypothalamic-pituitary function to combined stressors of exercise, energy deficit, and cold. This is the first study to capture in situ endocrine responses during an Antarctic traverse, advancing our understanding of human adaptation in extreme environments.
- 16 May 2024
- Published by BMJ in BMJ Military Health
- Vol. 171 (4) , 382-383
Enhancing decision-making in the Armed Forces through wearable technology: what do commanders think?
- 16 May 2024
- Published by BMJ in BMJ Military Health
- Vol. 171 (4) , 382-383
Enhancing decision-making in the Armed Forces through wearable technology: what do commanders think?
- 11 April 2024
- Published by BMJ in BMJ Military Health
- Vol. 171 (4) , 350-356
Assessment of salivary cortisol dynamics in an infantry training exercise: a pilot study
Introduction: Measuring cortisol during military training offers insights into physiological responses to stress. We attempted precisely timed, cortisol awakening response (CAR) and pre-sleep cortisol (PSC), and diurnal slope (peak morning minus evening cortisol), during a British Army exercise. We aimed to understand cortisol dynamics and evaluate the feasibility of CAR and PSC in this environment. Method: Setting: high-intensity, 10-day infantry exercise. Participants: regular infantry soldiers exercising (EX, n=25) or headquarters-based (HQ, n=6). Participants undertook PSC and WAKE and WAKE+30 min samples after 1–2 days, 5–6 days and 9–10 days. Wrist-worn GENEActiv accelerometers were used to assess sleep duration in EX only. Samples taken ±15 min from prespecified time points were deemed adherent. Validated questionnaires were used to measure resilience and perceived stress. Cortisol and cortisone were measured simultaneously by liquid chromatography tandem mass spectrometry. Results: From adherent participants’ samples, CAR was positive and tended to decrease as the exercise progressed. From all available data, HQ demonstrated greater diurnal slope than EX (F=7.68, p=0.02), reflecting higher morning cortisol (F=4.72, p=0.038) and lower PSC (p=0.04). No differences were seen in cortisol:cortisone ratio. 26.1% of CAR samples were adherent, with moderately strong associations between adherence and stress (r=0.41, p=0.009) but no association between adherence and day of exercise (χ2=0.27, p=0.8), sleep duration (r=–0.112, p=0.43) or resilience (r=–0.79, p=0.75). Test–retest reliability ratings for CAR were Cronbach’s α of 0.48, –11.7 and 0.34 for the beginning, middle and end of the exercise, respectively. Conclusions: We observed a reduction in morning cortisol and decreased diurnal slope during a high-intensity military exercise, compared with the HQ comparator cohort in whom diurnal slope was preserved. A carefully timed CAR was not feasible in this setting.
- 11 April 2024
- Published by BMJ in BMJ Military Health
- Vol. 171 (4) , 350-356
Assessment of salivary cortisol dynamics in an infantry training exercise: a pilot study
Introduction: Measuring cortisol during military training offers insights into physiological responses to stress. We attempted precisely timed, cortisol awakening response (CAR) and pre-sleep cortisol (PSC), and diurnal slope (peak morning minus evening cortisol), during a British Army exercise. We aimed to understand cortisol dynamics and evaluate the feasibility of CAR and PSC in this environment. Method: Setting: high-intensity, 10-day infantry exercise. Participants: regular infantry soldiers exercising (EX, n=25) or headquarters-based (HQ, n=6). Participants undertook PSC and WAKE and WAKE+30 min samples after 1–2 days, 5–6 days and 9–10 days. Wrist-worn GENEActiv accelerometers were used to assess sleep duration in EX only. Samples taken ±15 min from prespecified time points were deemed adherent. Validated questionnaires were used to measure resilience and perceived stress. Cortisol and cortisone were measured simultaneously by liquid chromatography tandem mass spectrometry. Results: From adherent participants’ samples, CAR was positive and tended to decrease as the exercise progressed. From all available data, HQ demonstrated greater diurnal slope than EX (F=7.68, p=0.02), reflecting higher morning cortisol (F=4.72, p=0.038) and lower PSC (p=0.04). No differences were seen in cortisol:cortisone ratio. 26.1% of CAR samples were adherent, with moderately strong associations between adherence and stress (r=0.41, p=0.009) but no association between adherence and day of exercise (χ2=0.27, p=0.8), sleep duration (r=–0.112, p=0.43) or resilience (r=–0.79, p=0.75). Test–retest reliability ratings for CAR were Cronbach’s α of 0.48, –11.7 and 0.34 for the beginning, middle and end of the exercise, respectively. Conclusions: We observed a reduction in morning cortisol and decreased diurnal slope during a high-intensity military exercise, compared with the HQ comparator cohort in whom diurnal slope was preserved. A carefully timed CAR was not feasible in this setting.
- 24 November 2023
- Published by BMJ in BMJ Military Health
- Vol. 171 (3) , 245-249
Five-day evaluation of the acceptability and comfort of wearable technology at four anatomical locations during military training
Introduction: Wearable sensor technologies enable Defence to optimise human performance, remotely identify physiological abnormalities and enhance medical support. Maximising the acceptability of devices will ensure they are worn alongside other equipment. This study assessed the acceptability and comfort of four devices at different anatomical locations during military training. Method: A cross-sectional pilot study during a live firing infantry exercise or adventurous training assessed four anatomical locations concurrently over 5 days: finger, wrist, upper arm and chest. Participants rated comfort, acceptability and preference using a standardised questionnaire after 12 hours and 5 days of wear. Results: Twenty-one regular British Army personnel soldiers participated, aged 24.4 (4.3) years. The upper arm location received the highest rating by participants for comfort, followed in order by wrist, finger and chest (p=0.002, Χ2=40.0). The finger was most commonly identified as uncomfortable during specific activities (76%), followed by chest (48%), wrist (23%) and upper arm devices (14%). There was no significant difference in participant confidence in the devices to collect data or allow movement, but there was a trend towards greater confidence in upper arm and wrist locations to stay in position than the others (p=0.059, Χ2=28.0). After 5 days of wear, 43% of participants said they preferred the upper arm for comfort, followed by wrist (36%), finger (24%) and chest (10%). 73% and 71% would wear the wrist and upper arm devices on deployed operations, compared with 29% and 24% for chest and finger devices, respectively. Conclusion: The upper arm location offered greater acceptability and comfort than finger, wrist or chest locations. It is essential to consider such findings from occupationally relevant settings when selecting wearable technology. A larger service evaluation in diverse settings is recommended to guide the choice of the most acceptable wearable devices across different equipment, roles and environments.
- 24 November 2023
- Published by BMJ in BMJ Military Health
- Vol. 171 (3) , 245-249
Five-day evaluation of the acceptability and comfort of wearable technology at four anatomical locations during military training
Introduction: Wearable sensor technologies enable Defence to optimise human performance, remotely identify physiological abnormalities and enhance medical support. Maximising the acceptability of devices will ensure they are worn alongside other equipment. This study assessed the acceptability and comfort of four devices at different anatomical locations during military training. Method: A cross-sectional pilot study during a live firing infantry exercise or adventurous training assessed four anatomical locations concurrently over 5 days: finger, wrist, upper arm and chest. Participants rated comfort, acceptability and preference using a standardised questionnaire after 12 hours and 5 days of wear. Results: Twenty-one regular British Army personnel soldiers participated, aged 24.4 (4.3) years. The upper arm location received the highest rating by participants for comfort, followed in order by wrist, finger and chest (p=0.002, Χ2=40.0). The finger was most commonly identified as uncomfortable during specific activities (76%), followed by chest (48%), wrist (23%) and upper arm devices (14%). There was no significant difference in participant confidence in the devices to collect data or allow movement, but there was a trend towards greater confidence in upper arm and wrist locations to stay in position than the others (p=0.059, Χ2=28.0). After 5 days of wear, 43% of participants said they preferred the upper arm for comfort, followed by wrist (36%), finger (24%) and chest (10%). 73% and 71% would wear the wrist and upper arm devices on deployed operations, compared with 29% and 24% for chest and finger devices, respectively. Conclusion: The upper arm location offered greater acceptability and comfort than finger, wrist or chest locations. It is essential to consider such findings from occupationally relevant settings when selecting wearable technology. A larger service evaluation in diverse settings is recommended to guide the choice of the most acceptable wearable devices across different equipment, roles and environments.