Evangelina Martínez-Francés
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Evangelina Martínez-Francés has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Verónica Morán
Medical Physics and Radiation Protection Department, Clínica Universidad de Navarra, Madrid, Spain
3 shared publications - Ana Maria Romero
CIEMAT, Radiation Dosimetry , Avda Complutense 40, 28040 Madrid, Spain
2 shared publications - Carles Domingo
Universitat Autónoma de Barcelona
2 shared publications - Josep María Marti-Climent
Department of Nuclear Medicine, Clínica Universidad de Navarra, Pamplona, Spain
2 shared publications - Pablo Cabello-García
Department of Medical Physics, Clínica Universidad de Navarra, 28027 Madrid, Spain
2 shared publications - Rafael Rodriguez
CIEMAT
2 shared publications
Latest Publications
- Open Access
- 26 May 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (11)
Out-of-field neutron doses in proton therapy: from experimental characterization to a practical calculation tool
Objective: To experimentally characterize out-of-field neutron dose in a pencil beam scanning (PBS) proton therapy treatment room using multiple detectors, to analyze its dependence on proton energy, gantry angle, distance to isocenter, and field size, and to develop a practical calculation tool for neutron dose estimation. Approach: Two extended-range ambient detectors, bubble (BDs) detectors, track-etch, thermoluminescent (TLDs), and three electronic personal dosimeters were used. Measurements were taken at up to 21 points for five proton energies, four gantry angles (ϴ), four field sizes, four measurement lines, and distances of 1-4.7 m from the isocenter. Room symmetry was evaluated. At each point, H*(10) or Hp(10) = a·E p b was assessed, and measurements were also performed for a clinical irradiation, with the resulting doses compared against weighted sums of contributions from individual energy layers. Bland-Altman analyses were applied. Main results: The room was symmetric for ϴ = 270º-90º, while doses at 0º were on average 8% lower than at 180º. Neutron doses for the spot field and 10 × 10 cm 2 field were interchangeable, with 20 × 20 and 30 × 30 cm 2 fields differing by 2-22%. Dose dependence on proton energy followed a power-law, with best fits for ambient detectors and moderate performance for BDs and TLDs. Linear superposition held for ambient and BDs, validating that neutron doses can be approximated as weighted sums of contributions from individual energy layers. A Python-based calculator for out-of-field neutron doses, provided as supplementary material, was developed for six detectors. Significance: This study delivers an easy-to-use Python tool for first-order estimation of out-of-field neutron doses in a PBS proton therapy room for any treatment plan or location. The tool is based on the linear superposition model, is validated against measurements, and accounts for detector-dependent uncertainties.
- 26 May 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (11)
Open AccessOut-of-field neutron doses in proton therapy: from experimental characterization to a practical calculation tool
Objective: To experimentally characterize out-of-field neutron dose in a pencil beam scanning (PBS) proton therapy treatment room using multiple detectors, to analyze its dependence on proton energy, gantry angle, distance to isocenter, and field size, and to develop a practical calculation tool for neutron dose estimation. Approach: Two extended-range ambient detectors, bubble (BDs) detectors, track-etch, thermoluminescent (TLDs), and three electronic personal dosimeters were used. Measurements were taken at up to 21 points for five proton energies, four gantry angles (ϴ), four field sizes, four measurement lines, and distances of 1-4.7 m from the isocenter. Room symmetry was evaluated. At each point, H*(10) or Hp(10) = a·E p b was assessed, and measurements were also performed for a clinical irradiation, with the resulting doses compared against weighted sums of contributions from individual energy layers. Bland-Altman analyses were applied. Main results: The room was symmetric for ϴ = 270º-90º, while doses at 0º were on average 8% lower than at 180º. Neutron doses for the spot field and 10 × 10 cm 2 field were interchangeable, with 20 × 20 and 30 × 30 cm 2 fields differing by 2-22%. Dose dependence on proton energy followed a power-law, with best fits for ambient detectors and moderate performance for BDs and TLDs. Linear superposition held for ambient and BDs, validating that neutron doses can be approximated as weighted sums of contributions from individual energy layers. A Python-based calculator for out-of-field neutron doses, provided as supplementary material, was developed for six detectors. Significance: This study delivers an easy-to-use Python tool for first-order estimation of out-of-field neutron doses in a PBS proton therapy room for any treatment plan or location. The tool is based on the linear superposition model, is validated against measurements, and accounts for detector-dependent uncertainties.
- Open Access
- 19 July 2025
- Published by Elsevier in Physica Medica
- Vol. 136, 105044
Intercomparison of personal and ambient neutron detectors used for radiation protection in a synchrotron-based proton therapy facility: experimental and Monte Carlo results
- 19 July 2025
- Published by Elsevier in Physica Medica
- Vol. 136, 105044
Open AccessIntercomparison of personal and ambient neutron detectors used for radiation protection in a synchrotron-based proton therapy facility: experimental and Monte Carlo results
- Open Access
- 4 April 2025
- Published by Wiley in Medical Physics
- Vol. 52 (6) , 4924-4940
Out‐of‐field neutron radiation from clinical proton, helium, carbon, and oxygen ion beams
Background: In hadron therapy, out‐of‐field doses, which may in the long‐term cause secondary cancers, are mostly due to neutrons. Very recently, 4 He and 16 O beams have been added to protons and 12 C ions for clinical therapy. Purpose: The focus of this article is to compare secondary neutron doses produced by clinical protons, 4 He, 12 C, and 16 O ion beams. Methods: Ambient dose equivalent, H *(10), measurements were performed, with five types of rem counters, of the neutron field produced by the four primary ions impinging on a water phantom. This experiment was performed at the Heidelberg Ion Beam Therapy Center (HIT) in the framework of the activities of the European Radiation Dosimetry Group (EURADOS). The experimental data are normalized to both unit primary particle and target dose, and are further compared to Monte Carlo (MC) simulations performed with the FLUKA and MCNP codes. Results: The intensity of the neutron field increases with ion mass, and the trend is more significant in the forward direction. The minimum H *(10) for all ions, 5µSv/Gy to 10µSv/Gy, was measured in the transverse and backward directions, whereas the maximum measured value was about 1.3 mSv/Gy for primary 16 O ions in the forward direction. Additional MC simulations are presented for a more detailed analysis of the rem counters’ response in the presence of heavy charged fragments. In the downstream direction, for 12 C and 16 O ions, approximately only 30% of the instruments’ counts are due to neutrons. Conclusion: The four extended‐range instruments provide reliable and consistent results, whereas the conventional rem counter underestimates H *(10) in a neutron field with a large high‐energy component. FLUKA and MCNP provide consistent predictions, within a factor of 1.6 for the downstream position and lower differences in the other cases, and are in agreement with the experimental data. It was found that under certain conditions neutrons do not represent the only secondary radiation field to be monitored; the presence of charged particles affects the performance of moderator‐type neutron detectors.
- 4 April 2025
- Published by Wiley in Medical Physics
- Vol. 52 (6) , 4924-4940
Open AccessOut‐of‐field neutron radiation from clinical proton, helium, carbon, and oxygen ion beams
Background: In hadron therapy, out‐of‐field doses, which may in the long‐term cause secondary cancers, are mostly due to neutrons. Very recently, 4 He and 16 O beams have been added to protons and 12 C ions for clinical therapy. Purpose: The focus of this article is to compare secondary neutron doses produced by clinical protons, 4 He, 12 C, and 16 O ion beams. Methods: Ambient dose equivalent, H *(10), measurements were performed, with five types of rem counters, of the neutron field produced by the four primary ions impinging on a water phantom. This experiment was performed at the Heidelberg Ion Beam Therapy Center (HIT) in the framework of the activities of the European Radiation Dosimetry Group (EURADOS). The experimental data are normalized to both unit primary particle and target dose, and are further compared to Monte Carlo (MC) simulations performed with the FLUKA and MCNP codes. Results: The intensity of the neutron field increases with ion mass, and the trend is more significant in the forward direction. The minimum H *(10) for all ions, 5µSv/Gy to 10µSv/Gy, was measured in the transverse and backward directions, whereas the maximum measured value was about 1.3 mSv/Gy for primary 16 O ions in the forward direction. Additional MC simulations are presented for a more detailed analysis of the rem counters’ response in the presence of heavy charged fragments. In the downstream direction, for 12 C and 16 O ions, approximately only 30% of the instruments’ counts are due to neutrons. Conclusion: The four extended‐range instruments provide reliable and consistent results, whereas the conventional rem counter underestimates H *(10) in a neutron field with a large high‐energy component. FLUKA and MCNP provide consistent predictions, within a factor of 1.6 for the downstream position and lower differences in the other cases, and are in agreement with the experimental data. It was found that under certain conditions neutrons do not represent the only secondary radiation field to be monitored; the presence of charged particles affects the performance of moderator‐type neutron detectors.
- Open Access
- 24 November 2023
- Published by CREIN, S.L. in Revista de Física Médica
- Vol. 24 (2) , 13-25
Puesta en funcionamiento de una instalación de protonterapia: Guía para preparar la documentación requerida
Las dos instalaciones de protonterapia actualmente operativas en España iniciaron sus proyectos en 2017. Si bien se trata de instalaciones radiactivas de segunda categoría, desde el punto de vista de la protección radiológica presentan una mayor complejidad que las instalaciones de radioterapia con haces de fotones y/o electrones, siendo el proceso de licenciamiento más complejo. El objetivo de este trabajo es proponer un documento modelo que pueda ser empleado en la elaboración de la documentación necesaria para el proceso de solicitud de autorización de instalaciones de protonterapia. Se ha llevado a cabo una revisión de los documentos que fueron evaluados por el Consejo de Seguridad Nuclear durante el proceso de autorización de la instalación radiactiva de protonterapia de la Clínica Universidad de Navarra, con el fin de elaborar una guía para la redacción de la memoria a presentar para la solicitud de la autorización y una relación de los procedimientos de protección radiológica que pueden ser de aplicación en una instalación de protonterapia, incluyendo datos de nuestro centro a modo de ejemplo: equipo y dependencias, monitores de radiación y enclavamientos y dispositivos de seguridad. Esta información será una herramienta útil para la puesta en funcionamiento de próximas instalaciones de protonterapia.
- 24 November 2023
- Published by CREIN, S.L. in Revista de Física Médica
- Vol. 24 (2) , 13-25
Open AccessPuesta en funcionamiento de una instalación de protonterapia: Guía para preparar la documentación requerida
Las dos instalaciones de protonterapia actualmente operativas en España iniciaron sus proyectos en 2017. Si bien se trata de instalaciones radiactivas de segunda categoría, desde el punto de vista de la protección radiológica presentan una mayor complejidad que las instalaciones de radioterapia con haces de fotones y/o electrones, siendo el proceso de licenciamiento más complejo. El objetivo de este trabajo es proponer un documento modelo que pueda ser empleado en la elaboración de la documentación necesaria para el proceso de solicitud de autorización de instalaciones de protonterapia. Se ha llevado a cabo una revisión de los documentos que fueron evaluados por el Consejo de Seguridad Nuclear durante el proceso de autorización de la instalación radiactiva de protonterapia de la Clínica Universidad de Navarra, con el fin de elaborar una guía para la redacción de la memoria a presentar para la solicitud de la autorización y una relación de los procedimientos de protección radiológica que pueden ser de aplicación en una instalación de protonterapia, incluyendo datos de nuestro centro a modo de ejemplo: equipo y dependencias, monitores de radiación y enclavamientos y dispositivos de seguridad. Esta información será una herramienta útil para la puesta en funcionamiento de próximas instalaciones de protonterapia.