Wenzhuo Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Wenzhuo Wang has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Chaozheng Xu
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Baoding 071003, China
1 shared publication - Defu Cai
State Grid Hubei Electric Power Research Institute, Wuhan 430064, China
1 shared publication - Guanqun Sun
State Grid Hubei Electric Power Research Institute, Wuhan 430077, China
1 shared publication - Ke Zhang
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Baoding 071003, China
1 shared publication - Shuqing Wei
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Baoding 071003, China
1 shared publication - Wang Ma
State Grid Hubei Electric Power Research Institute, Wuhan 430077, China
1 shared publication
Latest Publications
- Open Access
- 26 November 2023
- Published by MDPI AG in Electronics
- Vol. 12 (23) , 4790
A Fault Location Method for Medium Voltage Distribution Network Based on Ground Fault Transfer Device
The arc suppression device based on ground fault transfer (GFT) has been preliminarily applied in the medium voltage distribution network (MVDN). An accurate travelling wave (TW) fault location method is proposed to extend the use of the ground fault transfer device. D-PMU is used as a travelling wave detection tool to record the transient voltage travelling waves of fault grounding and bus active grounding during arc suppression. Then, the faulty section is identified through the time difference of travelling wave arrival at the upstream and downstream measurement points. On this basis, the fault location equations of the arrival time and distance of the upstream travelling wave are established, and an accurate fault location method based on the arrival time difference of the travelling wave is proposed. The simulation model is established by PSCAD/EMTDC, and the results show that the method has high location accuracy, and the absolute error is less than 30 m. It is not affected by the TW velocity, the fault conditions, or the distributed power sources.
- 26 November 2023
- Published by MDPI AG in Electronics
- Vol. 12 (23) , 4790
Open AccessA Fault Location Method for Medium Voltage Distribution Network Based on Ground Fault Transfer Device
The arc suppression device based on ground fault transfer (GFT) has been preliminarily applied in the medium voltage distribution network (MVDN). An accurate travelling wave (TW) fault location method is proposed to extend the use of the ground fault transfer device. D-PMU is used as a travelling wave detection tool to record the transient voltage travelling waves of fault grounding and bus active grounding during arc suppression. Then, the faulty section is identified through the time difference of travelling wave arrival at the upstream and downstream measurement points. On this basis, the fault location equations of the arrival time and distance of the upstream travelling wave are established, and an accurate fault location method based on the arrival time difference of the travelling wave is proposed. The simulation model is established by PSCAD/EMTDC, and the results show that the method has high location accuracy, and the absolute error is less than 30 m. It is not affected by the TW velocity, the fault conditions, or the distributed power sources.