Johanna Dalmo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Johanna Dalmo has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Johan Gustafsson
Lund University
2 shared publications Katarina Sjögreen Gleisner
Medical Radiation Physics, Lund, Lund University, Barngatan 4, Lund, 22184, SWEDEN
2 shared publications- Lovisa Jessen
Medical Radiation Physics, Lund, Lund University, Lund, Sweden
2 shared publications Mattias Sandström
Section of Nuclear Medicine and PET, Department of Surgical Sciences, Uppsala University, Akademiska Sjukhuset, Nuklearmedicin, ingång 100, Uppsala, 751 85, SWEDEN
2 shared publicationsCecilia Hindorf
Nuclear medicine and Medical physics, Karolinska University Hospital, Akademiska stråket 1, J4, Stockholm, 171 76, SWEDEN
1 shared publication- Cecilia Hindorf
Department of Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, Solna, Sweden
1 shared publication
Latest Publications
- Open Access
- 19 May 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (11) , 115001
A validation protocol for 177Lu-SPECT image quantification as a basis for multi-centre kidney dosimetry
Objective. Multicentre studies in molecular radiotherapy face challenges in ensuring the comparability of dosimetry results. The aim of this study was to develop a validation protocol to achieve equivalent 177Lu-SPECT quantification across centres, consisting of a test exercise in combination with an action level. Approach. 177Lu-SPECT/CT imaging of 3D-printed kidney phantoms with non-uniform activity distributions was conducted at five hospitals in Sweden and the UK. In total, 12 quantification systems (QSs) were included, where a QS was defined as the combination of a given camera system, reconstruction method and image-analysis method. The accuracy of image-based estimates of the activity concentration was investigated for three approaches to multicentre dosimetry: one site-specific, and two variants of centralised approaches. For the site-specific approach, the reference value was blinded to the evaluating operators. Prior to the evaluation, the participants agreed on an action level, specified as an obtained deviation larger than ±10% from the reference value. Sites responsible for a QS that yielded larger deviations, and therefore did not comply, were required to present an action plan, i.e., a plan for further method optimisation. Main results. For the site-specific approach, deviations larger than 10% were obtained for six out of 12 QS (range −11% to +27%). Action plans were presented for these QS and was implemented by one site (two QS). For the two variants of centralised approaches, where nine QS were included in total, deviations of within 10% were obtained for nine and seven QS, respectively. Significance. A quantification test combined with an action level can serve as an initial validation to enable further development and to achieve equivalent 177Lu-SPECT quantification across sites.
- 19 May 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (11) , 115001
Open AccessA validation protocol for 177Lu-SPECT image quantification as a basis for multi-centre kidney dosimetry
Objective. Multicentre studies in molecular radiotherapy face challenges in ensuring the comparability of dosimetry results. The aim of this study was to develop a validation protocol to achieve equivalent 177Lu-SPECT quantification across centres, consisting of a test exercise in combination with an action level. Approach. 177Lu-SPECT/CT imaging of 3D-printed kidney phantoms with non-uniform activity distributions was conducted at five hospitals in Sweden and the UK. In total, 12 quantification systems (QSs) were included, where a QS was defined as the combination of a given camera system, reconstruction method and image-analysis method. The accuracy of image-based estimates of the activity concentration was investigated for three approaches to multicentre dosimetry: one site-specific, and two variants of centralised approaches. For the site-specific approach, the reference value was blinded to the evaluating operators. Prior to the evaluation, the participants agreed on an action level, specified as an obtained deviation larger than ±10% from the reference value. Sites responsible for a QS that yielded larger deviations, and therefore did not comply, were required to present an action plan, i.e., a plan for further method optimisation. Main results. For the site-specific approach, deviations larger than 10% were obtained for six out of 12 QS (range −11% to +27%). Action plans were presented for these QS and was implemented by one site (two QS). For the two variants of centralised approaches, where nine QS were included in total, deviations of within 10% were obtained for nine and seven QS, respectively. Significance. A quantification test combined with an action level can serve as an initial validation to enable further development and to achieve equivalent 177Lu-SPECT quantification across sites.
- 20 November 2023
- Published by Elsevier in Physica Medica
- Vol. 116, 103170
Traceable calibration with 177Lu and comparison of activity meters at hospitals in Norway and Sweden
- 20 November 2023
- Published by Elsevier in Physica Medica
- Vol. 116, 103170
Traceable calibration with 177Lu and comparison of activity meters at hospitals in Norway and Sweden