Cecilia Hindorf
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Cecilia Hindorf has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Joachim N. Nilsson
Department of Nuclear Medicine and Medical Radiation Physics, Karolinska University Hospital, Stockholm, Sweden
2 shared publications - Johan Gustafsson
Lund University
2 shared publications Johan Blakkisrud
Department of Physics and Computational Radiology, Oslo University Hospital, Oslo, Norway
1 shared publication- Johanna Dalmo
Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Sahlgrenska Universitetssjukhuset, Nuklearmedicin, Blå stråket 5, Plan 1, uppgång D, Gothenburg, S-413 45, SWEDEN
1 shared publication - Jostein Sæterstøl
Department of Radiology, Haukeland University Hospital, Bergen, Norway
1 shared publication Katarina Sjögreen Gleisner
Department of Medical Radiation Physics, Lund University, Lund, Sweden
1 shared publication
Latest Publications
- Open Access
- 26 January 2025
- Published by Springer Nature in EJNMMI Physics
- Vol. 12 (1) , 1-19
Count-rate management in 131I SPECT/CT calibration
Background: System calibration is essential for accurate SPECT/CT dosimetry. However, count losses due to dead time and pulse pileup may cause calibration errors, in particular for 131I, where high count rates may be encountered. Calibration at low count rates should also be avoided to minimise detrimental effects from e.g. background counts and statistical fluctuations. This paper aims to present experimental data illustrating count-rate dependencies and to propose practical routines to mitigate errors in the 131I calibration procedure without needing advanced analysis tools. Results: The sensitivities of two General Electric (GE) Discovery 670 Pro systems were assessed using two Jaszczak phantom geometries. SPECT/CT data were collected over two months, starting with an initial 131I content of > 2 GBq, decaying to approximately 20 MBq. This allowed for a detailed analysis of count losses due to dead time and pulse pileup. From the sensitivity analysis, it was shown that robust calibration was obtained for 131I phantom activities ranging between 250 and 1500 MBq. Conclusions: The results show that adequate corrections for dead-time and pulse-pileup counting losses are essential for accurate calibration. It is argued that loss corrections should be based on total spectrum count rates in projections and not only on the 364.5 keV energy window data. The measurement campaigns presented in this paper, using basic tools and equipment, may serve as a model for establishing routines for count-loss corrections as well as for system calibration and regular control of system sensitivity. The data suggest that analysis of source and count concentration in a homogeneous Jaszczak phantom offers robust calibration, whereas analysis of source strength and counts in a delineated phantom insert offers a practical and robust method for regular quality control.
- 26 January 2025
- Published by Springer Nature in EJNMMI Physics
- Vol. 12 (1) , 1-19
Open AccessCount-rate management in 131I SPECT/CT calibration
Background: System calibration is essential for accurate SPECT/CT dosimetry. However, count losses due to dead time and pulse pileup may cause calibration errors, in particular for 131I, where high count rates may be encountered. Calibration at low count rates should also be avoided to minimise detrimental effects from e.g. background counts and statistical fluctuations. This paper aims to present experimental data illustrating count-rate dependencies and to propose practical routines to mitigate errors in the 131I calibration procedure without needing advanced analysis tools. Results: The sensitivities of two General Electric (GE) Discovery 670 Pro systems were assessed using two Jaszczak phantom geometries. SPECT/CT data were collected over two months, starting with an initial 131I content of > 2 GBq, decaying to approximately 20 MBq. This allowed for a detailed analysis of count losses due to dead time and pulse pileup. From the sensitivity analysis, it was shown that robust calibration was obtained for 131I phantom activities ranging between 250 and 1500 MBq. Conclusions: The results show that adequate corrections for dead-time and pulse-pileup counting losses are essential for accurate calibration. It is argued that loss corrections should be based on total spectrum count rates in projections and not only on the 364.5 keV energy window data. The measurement campaigns presented in this paper, using basic tools and equipment, may serve as a model for establishing routines for count-loss corrections as well as for system calibration and regular control of system sensitivity. The data suggest that analysis of source and count concentration in a homogeneous Jaszczak phantom offers robust calibration, whereas analysis of source strength and counts in a delineated phantom insert offers a practical and robust method for regular quality control.
- Open Access
- 6 February 2024
- Published by Springer Nature in EJNMMI Research
- Vol. 14 (1) , 1-10
Risk of treatment-altering haematological toxicity and its dependence on bone marrow doses in peptide receptor radionuclide therapy
Background: Peptide receptor radionuclide therapy is effective in treating neuroendocrine tumours, but treatment may be limited by kidney and bone marrow toxicity. In this work, the absorbed dose burden to the bone marrow was estimated using image-based dosimetry and its potential use for predicting treatment-altering toxicity was studied. Peripheral blood samples taken before and after 229 treatments with 177Lu-DOTATATE in 59 patients were studied. In connection to the treatments, a total of 940 blood sample occasions provided data on white blood cell, neutrophil granulocyte, platelet, erythrocyte and haemoglobin concentrations. SPECT/CT image data were collected at two or three time points after each treatment. Absorbed doses to bone marrow were calculated from the activity concentration in a metastasis-free lumbar vertebra. The rate of delayed and aborted treatments was analysed based on medical records. Results: The average absorbed dose to the bone marrow was 0.42 Gy (median 0.33 Gy, SD 0.27 Gy) per treatment. Dose–response relationships between white blood cells, neutrophil granulocytes and haemoglobin concentrations were observed, most prominently at 31–45 days after each treatment. The correlations were stronger in patients with skeletal metastases. The rates of haematological toxicity-related delays and aborted treatments were 6% and 12%, respectively. None of the studied bone marrow dosimetric parameters could clearly predict treatment-related toxicity. However, patients with skeletal metastases had higher risk of treatment-altering toxicity (odds ratio = 6.0). Conclusions: Treatment-altering haematological toxicity in peptide receptor radionuclide therapy is relatively rare and appears difficult to fully predict from post-therapeutic image-based dosimetry. However, for patients with skeletal metastases, the haematological dose–response relationships are stronger. Future studies may focus on this patient group, to further investigate the usefulness of dosimetry in predicting decreases in blood values.
- 6 February 2024
- Published by Springer Nature in EJNMMI Research
- Vol. 14 (1) , 1-10
Open AccessRisk of treatment-altering haematological toxicity and its dependence on bone marrow doses in peptide receptor radionuclide therapy
Background: Peptide receptor radionuclide therapy is effective in treating neuroendocrine tumours, but treatment may be limited by kidney and bone marrow toxicity. In this work, the absorbed dose burden to the bone marrow was estimated using image-based dosimetry and its potential use for predicting treatment-altering toxicity was studied. Peripheral blood samples taken before and after 229 treatments with 177Lu-DOTATATE in 59 patients were studied. In connection to the treatments, a total of 940 blood sample occasions provided data on white blood cell, neutrophil granulocyte, platelet, erythrocyte and haemoglobin concentrations. SPECT/CT image data were collected at two or three time points after each treatment. Absorbed doses to bone marrow were calculated from the activity concentration in a metastasis-free lumbar vertebra. The rate of delayed and aborted treatments was analysed based on medical records. Results: The average absorbed dose to the bone marrow was 0.42 Gy (median 0.33 Gy, SD 0.27 Gy) per treatment. Dose–response relationships between white blood cells, neutrophil granulocytes and haemoglobin concentrations were observed, most prominently at 31–45 days after each treatment. The correlations were stronger in patients with skeletal metastases. The rates of haematological toxicity-related delays and aborted treatments were 6% and 12%, respectively. None of the studied bone marrow dosimetric parameters could clearly predict treatment-related toxicity. However, patients with skeletal metastases had higher risk of treatment-altering toxicity (odds ratio = 6.0). Conclusions: Treatment-altering haematological toxicity in peptide receptor radionuclide therapy is relatively rare and appears difficult to fully predict from post-therapeutic image-based dosimetry. However, for patients with skeletal metastases, the haematological dose–response relationships are stronger. Future studies may focus on this patient group, to further investigate the usefulness of dosimetry in predicting decreases in blood values.
- 20 November 2023
- Published by Elsevier in Physica Medica
- Vol. 116, 103170
Traceable calibration with 177Lu and comparison of activity meters at hospitals in Norway and Sweden
- 20 November 2023
- Published by Elsevier in Physica Medica
- Vol. 116, 103170
Traceable calibration with 177Lu and comparison of activity meters at hospitals in Norway and Sweden