Xiaolong Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xiaolong Zhang has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Kiruba Sivasubramaniam Haran
Department of Electrical and Computer Engineering, University of Illinois Urbana-Champaign, Urbana, IL, USA
3 shared publications - Abdul Basit Mirza
Department of Electrical and Computer Engineering, Stony Brook University, Stony Brook, NY, USA
1 shared publication - Andrew Stillwell
Department of Electrical and and Computer Engineering, University of Illinois Urbana-Champaign, Urbana, IL, USA
1 shared publication - Anubhav Bose
Department of Electrical and Computer Engineering, University of Illinois Urbana-Champaign, Urbana, IL, USA
1 shared publication - Arjit Bali
Department of Electrical and Computer Engineering, University of Illinois Urbana-Champaign, Urbana, IL, USA
1 shared publication - Fang Luo
Electrical and Computer Engineering Department, Stony Brook University, Stony Brook, NY, USA
1 shared publication
Latest Publications
- Open Access
- 15 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Power Electronics
- Vol. 7, 209-225
Analysis and Design of a Multilevel Interleaved Hybrid Active Neutral Point Clamped Inverter for Electric Aircraft Propulsion
Electric vehicle and electric aviation applications require lightweight electro-mechanical energy conversion. However, passive components in the drive system can constrain the power density. Slotless machines enable high power density, but their low per-phase inductance imposes significant filtering challenges. This reduced inductance necessitates additional filtering between the inverter and motor, thereby offsetting the power density advantages of slotless designs. Additionally, the dc-link capacitor constitutes a substantial portion of the inverter's weight and volume. In this paper, the advantages of interleaved and multilevel topologies are discussed, and a partially interleaved hybrid active neutral point clamped (I-HANPC) converter is proposed to achieve reduced output filter sizes and enable a smaller dc-link capacitor. The design is demonstrated using a seven-level I-HANPC experimental hardware prototype at 10 kW, achieving a peak efficiency of 98.8%, an approximately 25% reduction in dc-link capacitor RMS current, and output total harmonic distortion well below 5%.
- 15 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Power Electronics
- Vol. 7, 209-225
Open AccessAnalysis and Design of a Multilevel Interleaved Hybrid Active Neutral Point Clamped Inverter for Electric Aircraft Propulsion
Electric vehicle and electric aviation applications require lightweight electro-mechanical energy conversion. However, passive components in the drive system can constrain the power density. Slotless machines enable high power density, but their low per-phase inductance imposes significant filtering challenges. This reduced inductance necessitates additional filtering between the inverter and motor, thereby offsetting the power density advantages of slotless designs. Additionally, the dc-link capacitor constitutes a substantial portion of the inverter's weight and volume. In this paper, the advantages of interleaved and multilevel topologies are discussed, and a partially interleaved hybrid active neutral point clamped (I-HANPC) converter is proposed to achieve reduced output filter sizes and enable a smaller dc-link capacitor. The design is demonstrated using a seven-level I-HANPC experimental hardware prototype at 10 kW, achieving a peak efficiency of 98.8%, an approximately 25% reduction in dc-link capacitor RMS current, and output total harmonic distortion well below 5%.
- Open Access
- 28 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 39 (2) , 1059-1074
Frequency-Domain Analytical Prediction of PWM-Induced Current Harmonics in Slotless Surface-Mounted PM Synchronous Machines
Slotless surface-mounted permanent magnet (PM) synchronous machines with high pole numbers generally have relatively low inductance, which will lead to significant current harmonics under PWM-driven inverters. Current harmonics can cause additional losses and torque ripples, severely impacting temperature rises and mechanical vibrations. Accurate prediction of current harmonics is crucial for machine performance calculation and drive system design. This article proposes a frequency-domain analytical method to predict the current harmonics with high fidelity equivalent circuit models. The harmonic prediction method is validated experimentally under a wide range of operating conditions and improves the prediction accuracy by up to 75% compared to the existing analytical modeling methods. The prediction error using the proposed method is generally maintained below 10%, making it an effective tool for practical applications.
- 28 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 39 (2) , 1059-1074
Open AccessFrequency-Domain Analytical Prediction of PWM-Induced Current Harmonics in Slotless Surface-Mounted PM Synchronous Machines
Slotless surface-mounted permanent magnet (PM) synchronous machines with high pole numbers generally have relatively low inductance, which will lead to significant current harmonics under PWM-driven inverters. Current harmonics can cause additional losses and torque ripples, severely impacting temperature rises and mechanical vibrations. Accurate prediction of current harmonics is crucial for machine performance calculation and drive system design. This article proposes a frequency-domain analytical method to predict the current harmonics with high fidelity equivalent circuit models. The harmonic prediction method is validated experimentally under a wide range of operating conditions and improves the prediction accuracy by up to 75% compared to the existing analytical modeling methods. The prediction error using the proposed method is generally maintained below 10%, making it an effective tool for practical applications.
- 6 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (1) , 1244-1253
Cable and Motor Winding Impedance Interactions in Motor Drive Systems and its Impact on HF Overvoltages
Voltage stress across motor winding is critical for insulation health when its series resonance frequencies, which have the least impedances, known as antiresonances, coincide with overvoltage (OV) resonance frequencies across it, named as antiresonance phenomenon (ARP). First, this article discloses that the OV resonance frequencies across motor winding (load) can be represented by the combination impedance of cable plus load. Second, it investigates the interactions between the cable and load impedances in different layouts and examines their impact on the ARP. Then, it discloses the sensitivity of ARP versus cable and load impedance parameters. Lastly, the ARP's correlation with these parameters establishes a safe operation area as a motor drive system design guideline. Contrary to the general belief that systems using short cable or integrated systems have less insulation damage, this study shows that the OV stress in these systems can be critical. This article offers a simplified methodology to optimize the reliability of the drive system and mitigate the ARP. By using this approach, the article suggests that the time-consuming iterative design of dV/dt filters or overdesign of insulation can be eliminated. The practical test and modeled system are conducted to validate the approach.
- 6 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (1) , 1244-1253
Cable and Motor Winding Impedance Interactions in Motor Drive Systems and its Impact on HF Overvoltages
Voltage stress across motor winding is critical for insulation health when its series resonance frequencies, which have the least impedances, known as antiresonances, coincide with overvoltage (OV) resonance frequencies across it, named as antiresonance phenomenon (ARP). First, this article discloses that the OV resonance frequencies across motor winding (load) can be represented by the combination impedance of cable plus load. Second, it investigates the interactions between the cable and load impedances in different layouts and examines their impact on the ARP. Then, it discloses the sensitivity of ARP versus cable and load impedance parameters. Lastly, the ARP's correlation with these parameters establishes a safe operation area as a motor drive system design guideline. Contrary to the general belief that systems using short cable or integrated systems have less insulation damage, this study shows that the OV stress in these systems can be critical. This article offers a simplified methodology to optimize the reliability of the drive system and mitigate the ARP. By using this approach, the article suggests that the time-consuming iterative design of dV/dt filters or overdesign of insulation can be eliminated. The practical test and modeled system are conducted to validate the approach.