ZHZhao-Qi-Zhi Han

Zhao-Qi-Zhi Han

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Zhao-Qi-Zhi Han has a total of 54 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Mid-infrared high-sensitivity cavity-free in situ CO gas sensing based on upconversion detection

    by Zhao-Qi-Zhi Han, He Zhang, Fan Yang, Xiao-Hua Wang, Bo-Wen Liu, Jin-Peng Li, Zheng-He Zhou, Yin-Hai Li, Yan Li, Zhi-Yuan Zhou, et al.

    Carbon monoxide (CO) is a significant indicator gas with considerable application value in atmospheric monitoring, industrial production, and medical diagnosis. Its fundamental vibrational band is located around 4.6 µm and has a larger absorption line strength than the overtone band, making it more suitable for precise identification and concentration detection of CO. In this paper, upconversion detection is employed to convert the mid-infrared absorption signal obtained by TDLAS to the visible light band; then a silicon-based detector is utilized for detection. With this approach, we can achieve the highest sensitivity of 79.6 ppb under cavity-free in situ conditions with an absorption path length of only 0.14 m. Furthermore, single-photon-level real-time detection of CO concentration after diffuse reflection is realized by using SPADs. This work demonstrates the merits of the upconversion detection in terms of its functionality at room temperature and capacity for sensitive detection. Furthermore, it presents a design and optimization methodology that has the potential to underpin the advancement of the method towards more practical applications, such as industrial process monitoring, medical diagnosis, and so on.

  • A broadband SWIR upconversion spectrometer based on noncritically phase-matched KTP

    by Xiao-Hua Wang, Chang-Hao Min, Zhao-Qi-Zhi Han, Qi-Yu Chen, Jin-Peng Li, Bo-Wen Liu, Yin-Hai Li, Zhi-Yuan Zhou, Bao-Sen Shi

    We report a broadband scanning short-wave infrared (SWIR) upconversion spectrometer based on noncritically phase-matched (NCPM) bulk KTP. The SWIR signal is dispersed and selected before upconversion, allowing the dispersive element to resolve the larger wavelength intervals at the original SWIR wavelengths rather than the compressed intervals after upconversion. For the pump wavelength and type-II interaction used here, the phase mismatch vanishes at two signal wavelengths in the SWIR region, and a sufficiently short crystal broadens the corresponding acceptance bands and allows them to overlap, producing a nearly continuous broadband response. After calibrating the wavelength axis, we measured the upconversion spectral responses of 2.0 and 0.5 mm crystals over 1.35–2.14 μm. The 2.0 mm crystal exhibited two separated response peaks, whereas the 0.5 mm crystal produced a broad, nearly continuous response, consistent with the phase-matching model. A narrowband measurement at 1550 nm yielded a spectral resolution of 0.14 nm. These results demonstrate the operating principle of broadband scanning SWIR upconversion spectroscopy with bulk NCPM KTP and provide the wavelength-dependent system-response characterization needed for broadband spectral measurements.

  • All optical broadband tunable quantum frequency shifter

    by Li Chen, Jia-Ning Guo, Di-Yuan Zheng, Ming-Yuan Gao, Zhao-Qi-Zhi Han, Wu-Zhen Li, Yue-Wei Song, Ren-Hui Chen, Chun Zhou, Wan-Su Bao, et al.

    A frequency shifter of the photon is a key component for frequency-multiplexed high-capacity quantum communications and frequency-encoded quantum computation. Existed methods for shifting the frequency of a photon based on electro-optical or acousto-optical effect, however, suffer the limited frequency shift up to a few hundreds of GHz; furthermore, high-quality micro-wave electronics are required. The frequency of a photon can also be shifted with the frequency difference equal to the frequency of pump laser by using an all optical-wave-mixing approach, which is usually about tens of THz. So, there is a big frequency shifting gap between these methods. Here, we propose a new scheme of a quantum frequency shifter based on an all-optical-wave-mixing process, which can theoretically achieve a frequency shift ranging from GHz to a few THz, therefore bridging the gap. As a principle of poof, by using two pump beams in a three-wave mixing cascading process, a heralded single photon is frequency-shifted more than ±400 GHz, and the shift can be tuned continuously over broadband by changing the frequency difference between two pump lasers. In addition, high coincidence to accidence ratio between the shifted photons and the heralded photon indicates the preserve of quantum properties. The present quantum frequency shifter is in analog to an electro-optical based shifter, but with much broader tuning ability. Our all-optical quantum frequency shifter will become a fundamental building block for high-speed quantum communication networks and frequency-domain photonic quantum computation.

  • Short-wave infrared broadband up-conversion imaging by using a noncritical phase-matched bulk KTiOPO 4 crystal

    by Xiao-Hua Wang, Zhao-Qi-Zhi Han, Zheng-He Zhou, Jin-Peng Li, Bo-Wen Liu, He Zhang, Yin-Hai Li, Zhi-Yuan Zhou, Bao-Sen Shi

    Compared with direct short-wave infrared (SWIR) detection, up-conversion imaging enables room-temperature SWIR imaging using mature visible-band detectors. However, poled crystals are limited by their small apertures, while large-aperture critical phase-matched (CPM) bulk crystals usually suffer from walk-off-induced image degradation. Here we demonstrate broadband SWIR up-conversion imaging using a noncritical phase-matched KTiOPO 4 crystal with a 6 mm × 7 mm aperture and a length of 0.5 mm. The system operates over a spectral range of 1.3–2.2 μm and achieves finest resolvable linewidths of 8.8 μm and 12.4 μm at illumination wavelengths of 1.334 μm and 1.792 μm, respectively. These values correspond to about 5–6× and 2× improvements in two orthogonal directions over the aperture-limited resolution of a representative 1 mm × 3 mm poled crystal. The absence of walk-off improves image fidelity, and the measured performance approaches the theoretical resolution limit. This study presents the first, to the best of our knowledge, comprehensive characterization of NCPM-based broadband up-conversion imaging and establishes a fixed-crystal route to high-resolution broadband SWIR up-conversion imaging.


  • Cavity-enhanced polarization-independent frequency conversion for vector beams

    by Ren-Hui Chen, Zhi-Cheng Guo, Zheng-Bang Ju, Ming-Yuan Gao, Zhao-Qi-Zhi Han, Yue-Wei Song, Xiao-Hua Wang, Yin-Hai Li, Yan Li, Wei Zhang, et al.

    Vector beams with spatially varying polarization, represented on the higher-order Poincaré sphere, are indispensable in optical communications, imaging, and quantum information science. However, nonlinear frequency conversion of vector beams remains challenging due to sensitivity and limited conversion efficiency. Here, we demonstrate a highly efficient, external-cavity-enhanced, polarization-independent frequency conversion based on difference-frequency generation for vector beams. Benefiting from cavity enhancement within the Sagnac configuration, we achieve external quantum efficiencies of 43.85% and 16.83% for vector beams with l =1 and l =2, respectively, demonstrating efficient continuous-wave frequency conversion. The preservation of the vectorial polarization structure in the converted beams is verified by spatial Stokes measurements. This work demonstrates an efficient approach for wavelength manipulation of vector beams and is potentially relevant to applications in structured-light control and nonlinear photonic interfaces.


  • Open Access

    On-chip quantum states generation by incoherent light

    by Yue-Wei Song, Heng Zhao, Li Chen, Yin-Hai Li, En-Ze Li, Ming-Yuan Gao, Ren-Hui Chen, Zhao-Qi-Zhi Han, Meng-Yu Xie, Guang-Can Guo, et al.

    On-chip quantum sources based on nonlinear processes are pivotal components in integrated photonics, driving significant advancements in quantum information technologies over recent decades. Usually, the pump coherence has been considered to be crucial for ensuring the quality of generated states, therefore incoherent light is rarely used in quantum information processing. In this work, we explore and reveal the constructive influence of pumped temporal incoherence on the quantum properties of photon sources. Taking silicon waveguides as nonlinear media, we theoretically show that temporal incoherence of light can improve pump utilization efficiency, resulting in higher source brightness in a spontaneous four-wave mixing process. Compared with coherent lasers, the frequency-uncorrelated character of incoherent light reduces spectral correlations in the generated photons, facilitating higher state purity in practice. Experimentally, we obtain a higher photon pair generation rate and the lower heralded second-order autocorrelation with an Amplified Spontaneous Emission source. Additionally, we successfully generate a polarization-entangled state with Bell inequality violation of S = 2.64 ± 0.02 and a fidelity of 95.7% ± 0.1%. Our study reveals the mechanism behind incoherently pumped quantum states and presents a method for generating photon sources using an easily accessible incoherent light.


  • High-resolution up-conversion imaging in the 10- μ m band under incoherent illumination

    by Zhaoqizhi Han, Xiaohua Wang, Jinpeng Li, Bowen Liu, Zhenghe Zhou, He Zhang, Yinhai Li, Zhiyuan Zhou, Baosen Shi


  • Open Access

    Quantum-enhanced imaging for characterizing anisotropic material

    by Meng-Yu Xie, Su-Jian Niu, Zhao-Qi-Zhi Han, Yin-Hai Li, Ren-Hui Chen, Xiao-Hua Wang, Ming-Yuan Gao, Li Chen, Yue-Wei Song, Zhi-Yuan Zhou, et al.


  • Sellmeier equation for the refractive index of ordinary light in 5 mol.% MgO-doped congruent lithium niobate

    by Bo-Wen Liu, Zhao-Qi-Zhi Han, Jin-Peng Li, Xiao-Hua Wang, Yin-Hai Li, Zhi-Yuan Zhou, Bao-Sen Shi

    Congruent lithium niobate is a type of lithium niobate crystal with a mature growth process and is widely used in nonlinear optics research. Its refractive index accuracy will play a crucial role in the research and application of nonlinear optics. In this paper, we theoretically analyze the accuracy and reliability of nonlinear methods and experimentally measure the refractive index of ordinary light at different wavelengths and temperatures in a non-critical phase matching LN crystal by the sum-frequency generation and spontaneous parametric down-conversion processes, with the help of the existing accurate Sellmeier equation for the refractive index of extraordinary light. By fitting the refractive index of ordinary light, a new set of parameters for the Sellmeier equation is established. This equation shows excellent agreement with existing experimental results, and greatly extends the range of wavelengths and temperatures to 0.5−10 μm and 20−250 ∘C.


  • In-lab high-resolution midinfrared up-conversion stellar interferometer based on a synthetic long baseline

    by Zhao-Qi-Zhi Han, Zheng Ge, Wen-Tao Luo, Yi-Fu Cai, Xiao-Hua Wang, Li Chen, Wu-Zhen Li, Zhi-Yuan Zhou, Bao-Sen Shi

    Detecting midinfrared (MIR) radiation has significant astronomical applications, although limited by unsatisfactory MIR detectors. Here we reported on the realization of a MIR up-conversion interferometer based on synthetic long base-line in the laboratory. The experimental system consisted of an interferometer and subsequent up-conversion detection part of midinfrared signal, which streamlined the structure and enhanced the reliability of the system. By using a tungsten filament lamp as an imitated star, we not only achieved the single target angle resolution of 1.10×10−4  rad, but also obtained the field angle resolution of 3.0×10−4  rad of double star targets. The angular resolution is in inverse proportion to the length of baseline. The maximum length of simulated baseline in the laboratory is about 3 cm. In a Keck interferometer liked program, the base line can reach up to 85 m leading to a corresponding angular resolution of 3×10−9  rad (about 1.8 mas). The study will offer potential benefits in extending the usage of midinfrared light in astronomical exploration.