XWXiao-Hua Wang

Xiao-Hua Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xiao-Hua Wang has a total of 34 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Mid-infrared high-sensitivity cavity-free in situ CO gas sensing based on upconversion detection

    by Zhao-Qi-Zhi Han, He Zhang, Fan Yang, Xiao-Hua Wang, Bo-Wen Liu, Jin-Peng Li, Zheng-He Zhou, Yin-Hai Li, Yan Li, Zhi-Yuan Zhou, et al.

    Carbon monoxide (CO) is a significant indicator gas with considerable application value in atmospheric monitoring, industrial production, and medical diagnosis. Its fundamental vibrational band is located around 4.6 µm and has a larger absorption line strength than the overtone band, making it more suitable for precise identification and concentration detection of CO. In this paper, upconversion detection is employed to convert the mid-infrared absorption signal obtained by TDLAS to the visible light band; then a silicon-based detector is utilized for detection. With this approach, we can achieve the highest sensitivity of 79.6 ppb under cavity-free in situ conditions with an absorption path length of only 0.14 m. Furthermore, single-photon-level real-time detection of CO concentration after diffuse reflection is realized by using SPADs. This work demonstrates the merits of the upconversion detection in terms of its functionality at room temperature and capacity for sensitive detection. Furthermore, it presents a design and optimization methodology that has the potential to underpin the advancement of the method towards more practical applications, such as industrial process monitoring, medical diagnosis, and so on.

  • A broadband SWIR upconversion spectrometer based on noncritically phase-matched KTP

    by Xiao-Hua Wang, Chang-Hao Min, Zhao-Qi-Zhi Han, Qi-Yu Chen, Jin-Peng Li, Bo-Wen Liu, Yin-Hai Li, Zhi-Yuan Zhou, Bao-Sen Shi

    We report a broadband scanning short-wave infrared (SWIR) upconversion spectrometer based on noncritically phase-matched (NCPM) bulk KTP. The SWIR signal is dispersed and selected before upconversion, allowing the dispersive element to resolve the larger wavelength intervals at the original SWIR wavelengths rather than the compressed intervals after upconversion. For the pump wavelength and type-II interaction used here, the phase mismatch vanishes at two signal wavelengths in the SWIR region, and a sufficiently short crystal broadens the corresponding acceptance bands and allows them to overlap, producing a nearly continuous broadband response. After calibrating the wavelength axis, we measured the upconversion spectral responses of 2.0 and 0.5 mm crystals over 1.35–2.14 μm. The 2.0 mm crystal exhibited two separated response peaks, whereas the 0.5 mm crystal produced a broad, nearly continuous response, consistent with the phase-matching model. A narrowband measurement at 1550 nm yielded a spectral resolution of 0.14 nm. These results demonstrate the operating principle of broadband scanning SWIR upconversion spectroscopy with bulk NCPM KTP and provide the wavelength-dependent system-response characterization needed for broadband spectral measurements.

  • Short-wave infrared broadband up-conversion imaging by using a noncritical phase-matched bulk KTiOPO 4 crystal

    by Xiao-Hua Wang, Zhao-Qi-Zhi Han, Zheng-He Zhou, Jin-Peng Li, Bo-Wen Liu, He Zhang, Yin-Hai Li, Zhi-Yuan Zhou, Bao-Sen Shi

    Compared with direct short-wave infrared (SWIR) detection, up-conversion imaging enables room-temperature SWIR imaging using mature visible-band detectors. However, poled crystals are limited by their small apertures, while large-aperture critical phase-matched (CPM) bulk crystals usually suffer from walk-off-induced image degradation. Here we demonstrate broadband SWIR up-conversion imaging using a noncritical phase-matched KTiOPO 4 crystal with a 6 mm × 7 mm aperture and a length of 0.5 mm. The system operates over a spectral range of 1.3–2.2 μm and achieves finest resolvable linewidths of 8.8 μm and 12.4 μm at illumination wavelengths of 1.334 μm and 1.792 μm, respectively. These values correspond to about 5–6× and 2× improvements in two orthogonal directions over the aperture-limited resolution of a representative 1 mm × 3 mm poled crystal. The absence of walk-off improves image fidelity, and the measured performance approaches the theoretical resolution limit. This study presents the first, to the best of our knowledge, comprehensive characterization of NCPM-based broadband up-conversion imaging and establishes a fixed-crystal route to high-resolution broadband SWIR up-conversion imaging.


  • Cavity-enhanced polarization-independent frequency conversion for vector beams

    by Ren-Hui Chen, Zhi-Cheng Guo, Zheng-Bang Ju, Ming-Yuan Gao, Zhao-Qi-Zhi Han, Yue-Wei Song, Xiao-Hua Wang, Yin-Hai Li, Yan Li, Wei Zhang, et al.

    Vector beams with spatially varying polarization, represented on the higher-order Poincaré sphere, are indispensable in optical communications, imaging, and quantum information science. However, nonlinear frequency conversion of vector beams remains challenging due to sensitivity and limited conversion efficiency. Here, we demonstrate a highly efficient, external-cavity-enhanced, polarization-independent frequency conversion based on difference-frequency generation for vector beams. Benefiting from cavity enhancement within the Sagnac configuration, we achieve external quantum efficiencies of 43.85% and 16.83% for vector beams with l =1 and l =2, respectively, demonstrating efficient continuous-wave frequency conversion. The preservation of the vectorial polarization structure in the converted beams is verified by spatial Stokes measurements. This work demonstrates an efficient approach for wavelength manipulation of vector beams and is potentially relevant to applications in structured-light control and nonlinear photonic interfaces.


  • High-resolution up-conversion imaging in the 10- μ m band under incoherent illumination

    by Zhaoqizhi Han, Xiaohua Wang, Jinpeng Li, Bowen Liu, Zhenghe Zhou, He Zhang, Yinhai Li, Zhiyuan Zhou, Baosen Shi


  • Open Access

    Quantum entanglement and interference at 3 μm

    by Zheng Ge, Zhao-Qi-Zhi Han, Fan Yang, Xiao-Hua Wang, Yin-Hai Li, Yan Li, Ming-Yuan Gao, Ren-Hui Chen, Su-Jian Niu, Meng-Yu Xie, et al.

    Given the important advantages of the mid-infrared optical range (2.5 to 25 μm) for biomedical sensing, optical communications, and molecular spectroscopy, extending quantum information technology to this region is highly attractive. However, the development of mid-infrared quantum information technology is still in its infancy. Here, we report on the generation of a time-energy entangled photon pair in the mid-infrared wavelength band. By using frequency upconversion detection technology, we observe the two-photon Hong-Ou-Mandel interference and demonstrate the time-energy entanglement between twin photons at 3082 nm via the Franson-type interferometer, verifying the indistinguishability and nonlocality of the photons. This work is very promising for future applications of optical quantum technology in the mid-infrared band, which will bring more opportunities in the fields of quantum communication, precision sensing, and imaging.


  • Midinfrared up-conversion imaging under different illumination conditions

    by Zheng Ge, Zhaoqizhi Han, Yiyang Liu, Xiaohua Wang, Zhiyuan Zhou, Fan Yang, Yinhai Li, Yan Li, Li Chen, Wuzhen Li, et al.

    Converting the medium-emitting infrared field to the visible band is an effective image-detection method. We propose a comprehensive theory of image up-conversion under continuous optical pumping, and discuss the relationship between the experimental parameters and imaging field of view, resolution, quantum efficiency, and conversion bandwidth. Theoretical predictions are given based on numerical simulations, which show good agreement with experimental results. In particular, coherent and incoherent light illumination are studied separately and the advantages and disadvantages of their imaging performance are compared and analyzed. This work provides a detailed study of the up-conversion image detection performance of the system, which is of great value in guiding the design of the detection system and bringing it to practical applications.