Lahcen El Moutaouakil
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Lahcen El Moutaouakil has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Mohammed Boukendil
Cadi Ayyad University
8 shared publications - Abdelhalim Abdelbaki
Cadi Ayyad University
6 shared publications M. Boukendil
6 shared publications- Zaki Zrikem
Cadi Ayyad University
6 shared publications - Rachid Hidki
National School of Applied Sciences (ENSA), Sultan Moulay Slimane University Beni Mellal Morocco
5 shared publications - Zouhair Charqui
Cadi Ayyad University
5 shared publications
Latest Publications
- 3 August 2026
- Published by Wiley in ZAMM - Journal of Applied Mathematics and Mechanics / Zeitschrift für Angewandte Mathematik und Mechanik
- Vol. 106 (8) , e70539
Analytical Solution for Natural Convection in an Internally Heated Inclined Cavity With Multiple Heat Source/Sink Pairs
This paper presents an analytical solution for steady‐state natural convection within an inclined rectangular cavity subject to volumetric heat generation and various configurations of discrete surface heat sources and sinks. The governing coupled partial differential equations (PDEs) are solved using a combination of Fourier series expansions and perturbation theory (PT), with the internal Rayleigh number (denoted as Ra), which characterizes the heat generated within the cavity, selected as the perturbation parameter and fixed at . The analysis considers key variables such as the number of heat source/sink pairs (), the aspect ratio of the cavity () and the inclination angle (). The temperature difference between heat sources and sinks, denoted by the amplitude (), is maintained at 0.5. The effects of these parameters are explored by examining streamlines, isotherms, and local Nusselt numbers. The analytical results are validated against numerical simulations, showing strong agreement between the two approaches, thus confirming the robustness of the analytical method employed.
- 3 August 2026
- Published by Wiley in ZAMM - Journal of Applied Mathematics and Mechanics / Zeitschrift für Angewandte Mathematik und Mechanik
- Vol. 106 (8) , e70539
Analytical Solution for Natural Convection in an Internally Heated Inclined Cavity With Multiple Heat Source/Sink Pairs
This paper presents an analytical solution for steady‐state natural convection within an inclined rectangular cavity subject to volumetric heat generation and various configurations of discrete surface heat sources and sinks. The governing coupled partial differential equations (PDEs) are solved using a combination of Fourier series expansions and perturbation theory (PT), with the internal Rayleigh number (denoted as Ra), which characterizes the heat generated within the cavity, selected as the perturbation parameter and fixed at . The analysis considers key variables such as the number of heat source/sink pairs (), the aspect ratio of the cavity () and the inclination angle (). The temperature difference between heat sources and sinks, denoted by the amplitude (), is maintained at 0.5. The effects of these parameters are explored by examining streamlines, isotherms, and local Nusselt numbers. The analytical results are validated against numerical simulations, showing strong agreement between the two approaches, thus confirming the robustness of the analytical method employed.
- 28 July 2026
- Published by Wiley in Energy Storage
- Vol. 8 (5) , e70479
Thermal Management of Electronic Components in a Ventilated Cavity: A Comparative Study of Phase Change Material, Air, and Hybrid Finned Heat Sink Configurations Under Mixed Convection and Surface Radiation
This study presents a comparative numerical investigation of thermal management in a rectangular cavity subjected to mixed convection and surface radiation. The system consists of two horizontally aligned electronic components, each equipped with a finned heat sink attached to its upper surface. Three heat sink designs are considered: (a) fins fully filled with phase change material (PCM), (b) conventional fins filled with air, and (c) an alternating arrangement of PCM and air between fin layers. A parametric analysis is conducted to evaluate the effects of the Reynolds number and the inlet flow inclination angle on the thermal performance of the system. The results indicate that increasing the Reynolds number enhances convective heat transfer, with maximum temperature reductions of approximately 0.43% (Case 1), 4.1% (Case 2), and 0.49% (Case 3). Decreasing the flow inclination angle from 60° to 0° further improves cooling performance, yielding reductions of 0.15% (Case 1), 1.06% (Case 2), and 0.21% (Case 3). A comparative assessment reveals that the PCM‐integrated configuration (Case 1) provides the best overall thermal performance, achieving a reduction in the maximum block temperature of up to 32 K compared to the air‐filled configuration (Case 2), obtained at Re = 200 and θ = 60°.
- 28 July 2026
- Published by Wiley in Energy Storage
- Vol. 8 (5) , e70479
Thermal Management of Electronic Components in a Ventilated Cavity: A Comparative Study of Phase Change Material, Air, and Hybrid Finned Heat Sink Configurations Under Mixed Convection and Surface Radiation
This study presents a comparative numerical investigation of thermal management in a rectangular cavity subjected to mixed convection and surface radiation. The system consists of two horizontally aligned electronic components, each equipped with a finned heat sink attached to its upper surface. Three heat sink designs are considered: (a) fins fully filled with phase change material (PCM), (b) conventional fins filled with air, and (c) an alternating arrangement of PCM and air between fin layers. A parametric analysis is conducted to evaluate the effects of the Reynolds number and the inlet flow inclination angle on the thermal performance of the system. The results indicate that increasing the Reynolds number enhances convective heat transfer, with maximum temperature reductions of approximately 0.43% (Case 1), 4.1% (Case 2), and 0.49% (Case 3). Decreasing the flow inclination angle from 60° to 0° further improves cooling performance, yielding reductions of 0.15% (Case 1), 1.06% (Case 2), and 0.21% (Case 3). A comparative assessment reveals that the PCM‐integrated configuration (Case 1) provides the best overall thermal performance, achieving a reduction in the maximum block temperature of up to 32 K compared to the air‐filled configuration (Case 2), obtained at Re = 200 and θ = 60°.
- Open Access
- 13 July 2026
- Published by Elsevier in SSRN Electronic Journal
Natural Convection and Thermal Radiation in a Circular Cavity with a Moving Heat Source and a Tracking Cold Sink
This study investigates coupled natural convection and surface radiation in a circular air-filled cavity containing a moving heated block and a mobile cold sink governed by a thermal tracking strategy. The heated block undergoes oscillatory motion along the horizontal diameter, while the cooling sink occupies a movable boundary arc whose position is dynamically adjusted according to local thermal gradients to intercept the thermal plume generated by the moving source. Numerical simulations are performed using the finite element method, combining an Arbitrary Lagrangian--Eulerian (ALE) moving mesh formulation with automatic remeshing to accurately capture coupled motions. Thermal performance is evaluated through the convective, radiative, and total heat transfer rates, together with the mean and maximum cavity temperatures. A parametric study examines the effects of the thermal sensitivity threshold, sink mobility, wall emissivity, initial sink angular position, heated block size, and sink angular extent on heat transfer and thermal regulation. The results reveal a transition between two regimes: a mobile--fixed (M--F) regime with weak thermal coupling and a mobile--mobile (M--M) regime characterized by efficient plume tracking. The M--M configuration significantly enhances thermal performance, leading to higher heat extraction rates and lower mean and maximum temperatures. This improvement is associated with plume localization, intensified convective transport, and attenuation of periodic thermal oscillations, confirmed by spectral analysis. Increasing sink mobility improves tracking efficiency, whereas large thermal sensitivity thresholds degrade thermal regulation. These findings demonstrate that adaptive thermal tracking provides an effective strategy for heat management in systems involving moving heat sources.
- 13 July 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessNatural Convection and Thermal Radiation in a Circular Cavity with a Moving Heat Source and a Tracking Cold Sink
This study investigates coupled natural convection and surface radiation in a circular air-filled cavity containing a moving heated block and a mobile cold sink governed by a thermal tracking strategy. The heated block undergoes oscillatory motion along the horizontal diameter, while the cooling sink occupies a movable boundary arc whose position is dynamically adjusted according to local thermal gradients to intercept the thermal plume generated by the moving source. Numerical simulations are performed using the finite element method, combining an Arbitrary Lagrangian--Eulerian (ALE) moving mesh formulation with automatic remeshing to accurately capture coupled motions. Thermal performance is evaluated through the convective, radiative, and total heat transfer rates, together with the mean and maximum cavity temperatures. A parametric study examines the effects of the thermal sensitivity threshold, sink mobility, wall emissivity, initial sink angular position, heated block size, and sink angular extent on heat transfer and thermal regulation. The results reveal a transition between two regimes: a mobile--fixed (M--F) regime with weak thermal coupling and a mobile--mobile (M--M) regime characterized by efficient plume tracking. The M--M configuration significantly enhances thermal performance, leading to higher heat extraction rates and lower mean and maximum temperatures. This improvement is associated with plume localization, intensified convective transport, and attenuation of periodic thermal oscillations, confirmed by spectral analysis. Increasing sink mobility improves tracking efficiency, whereas large thermal sensitivity thresholds degrade thermal regulation. These findings demonstrate that adaptive thermal tracking provides an effective strategy for heat management in systems involving moving heat sources.
- 9 June 2026
- Published by Wiley in Heat Transfer
Transient Hybrid Cooling of Dual Heat Sources in a Diverging–Converging Channel
This study presents an original numerical investigation of transient forced‐convection heat transfer in a channel coupled with a phase change material (PCM) for advanced thermal management of electronic components. The proposed configuration integrates a flow‐guiding obstacle together with porous and solid fins, aiming to intensify convective heat transfer and enhance heat removal efficiency. A comprehensive parametric analysis is conducted to assess the effects of key hydrodynamic and geometric parameters, including the heated block geometry (rectangle, triangle, square, semi‐circle), Reynolds number , axial obstacle displacement , channel height , obstacle size , and cavity inclination angle . The results demonstrate that forced convection intensification, primarily governed by the Reynolds number, leads to a maximum temperature reduction of up to 6.3%. The height of the enlarged channel section significantly influences the thermal performance, with a reduction in this height leading to an approximately 9% decrease in temperature. The effect of the flow‐guiding obstacle size is also investigated, showing that an increase in its size leads to a reduction in the maximum temperature of up to 8% for Re = 600. Moreover, an optimal cavity inclination of provides additional improvement in heat transfer efficiency. These findings highlight a robust and high‐performance design strategy for thermal management in electronic cooling applications.
- 9 June 2026
- Published by Wiley in Heat Transfer
Transient Hybrid Cooling of Dual Heat Sources in a Diverging–Converging Channel
This study presents an original numerical investigation of transient forced‐convection heat transfer in a channel coupled with a phase change material (PCM) for advanced thermal management of electronic components. The proposed configuration integrates a flow‐guiding obstacle together with porous and solid fins, aiming to intensify convective heat transfer and enhance heat removal efficiency. A comprehensive parametric analysis is conducted to assess the effects of key hydrodynamic and geometric parameters, including the heated block geometry (rectangle, triangle, square, semi‐circle), Reynolds number , axial obstacle displacement , channel height , obstacle size , and cavity inclination angle . The results demonstrate that forced convection intensification, primarily governed by the Reynolds number, leads to a maximum temperature reduction of up to 6.3%. The height of the enlarged channel section significantly influences the thermal performance, with a reduction in this height leading to an approximately 9% decrease in temperature. The effect of the flow‐guiding obstacle size is also investigated, showing that an increase in its size leads to a reduction in the maximum temperature of up to 8% for Re = 600. Moreover, an optimal cavity inclination of provides additional improvement in heat transfer efficiency. These findings highlight a robust and high‐performance design strategy for thermal management in electronic cooling applications.
- Open Access
- 26 May 2026
- Published by Elsevier in SSRN Electronic Journal
Natural Convection and Thermal Radiation in a Circular Cavity with a Moving Heat Source and a Tracking Cold Sink
This study investigates coupled natural convection and surface radiation in a circular air-filled cavity containing a moving heated block and a mobile cold sink governed by a thermal tracking strategy. The heated block undergoes oscillatory motion along the horizontal diameter, while the cooling sink occupies a movable boundary arc whose position is dynamically adjusted according to local thermal gradients to intercept the thermal plume generated by the moving source. Numerical simulations are performed using the finite element method, combining an Arbitrary Lagrangian--Eulerian (ALE) moving mesh formulation with automatic remeshing to accurately capture coupled motions. Thermal performance is evaluated through the convective, radiative, and total heat transfer rates, together with the mean and maximum cavity temperatures. A parametric study examines the effects of the thermal sensitivity threshold, sink mobility, wall emissivity, initial sink angular position, heated block size, and sink angular extent on heat transfer and thermal regulation. The results reveal a transition between two regimes: a mobile--fixed (M--F) regime with weak thermal coupling and a mobile--mobile (M--M) regime characterized by efficient plume tracking. The M--M configuration significantly enhances thermal performance, leading to higher heat extraction rates and lower mean and maximum temperatures. This improvement is associated with plume localization, intensified convective transport, and attenuation of periodic thermal oscillations, confirmed by spectral analysis. Increasing sink mobility improves tracking efficiency, whereas large thermal sensitivity thresholds degrade thermal regulation. These findings demonstrate that adaptive thermal tracking provides an effective strategy for heat management in systems involving moving heat sources.
- 26 May 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessNatural Convection and Thermal Radiation in a Circular Cavity with a Moving Heat Source and a Tracking Cold Sink
This study investigates coupled natural convection and surface radiation in a circular air-filled cavity containing a moving heated block and a mobile cold sink governed by a thermal tracking strategy. The heated block undergoes oscillatory motion along the horizontal diameter, while the cooling sink occupies a movable boundary arc whose position is dynamically adjusted according to local thermal gradients to intercept the thermal plume generated by the moving source. Numerical simulations are performed using the finite element method, combining an Arbitrary Lagrangian--Eulerian (ALE) moving mesh formulation with automatic remeshing to accurately capture coupled motions. Thermal performance is evaluated through the convective, radiative, and total heat transfer rates, together with the mean and maximum cavity temperatures. A parametric study examines the effects of the thermal sensitivity threshold, sink mobility, wall emissivity, initial sink angular position, heated block size, and sink angular extent on heat transfer and thermal regulation. The results reveal a transition between two regimes: a mobile--fixed (M--F) regime with weak thermal coupling and a mobile--mobile (M--M) regime characterized by efficient plume tracking. The M--M configuration significantly enhances thermal performance, leading to higher heat extraction rates and lower mean and maximum temperatures. This improvement is associated with plume localization, intensified convective transport, and attenuation of periodic thermal oscillations, confirmed by spectral analysis. Increasing sink mobility improves tracking efficiency, whereas large thermal sensitivity thresholds degrade thermal regulation. These findings demonstrate that adaptive thermal tracking provides an effective strategy for heat management in systems involving moving heat sources.
- 6 April 2026
- Published by Wiley in Energy Storage
- Vol. 8 (3)
Transient Thermal Management of Heat‐Generating Blocks in a Partitioned Rectangular Cavity Using Forced Convection, Phase Change Material, Guiding Obstacle, and Fins
This study numerically examines transient heat transfer in a rectangular cavity integrating forced convection and latent heat storage. Three heat‐generating blocks are mounted on a conductive plate separating an upper air region from a lower PCM domain. Heat is removed by forced airflow and conducted toward the PCM, whose thermal storage capacity is enhanced by vertical fins attached to the plate. The transient governing equations are solved using the finite element method. A parametric study evaluates the influence of fin shape and number , Reynolds number , obstacle position and inclination (), cavity inclination angle (), block thermal conductivity , and PCM melting temperature (). The results indicate that rectangular fins improve thermal performance, lowering the maximum block temperature by up to 13.67 K compared with triangular fins. Increasing the Reynolds number from 100 to 400 reduces peak temperatures by approximately 4.6%–5.0%. An optimal cavity inclination angle of is identified. In addition, a guiding obstacle at the optimal position effectively directs airflow, reducing the maximum temperature by 4.14%, a moderate fin number (), high block thermal conductivity , and a PCM with a higher melting temperature ( K) significantly enhance cooling efficiency. While increasing the Reynolds number strengthens the average Nusselt number, optimal obstacle configuration maximizes convective heat transfer, whereas larger channel heights tend to weaken it. Overall, the combined action of forced convection, fin‐assisted conduction, and latent heat storage emerges as an efficient approach for thermal management of electronic devices.
- 6 April 2026
- Published by Wiley in Energy Storage
- Vol. 8 (3)
Transient Thermal Management of Heat‐Generating Blocks in a Partitioned Rectangular Cavity Using Forced Convection, Phase Change Material, Guiding Obstacle, and Fins
This study numerically examines transient heat transfer in a rectangular cavity integrating forced convection and latent heat storage. Three heat‐generating blocks are mounted on a conductive plate separating an upper air region from a lower PCM domain. Heat is removed by forced airflow and conducted toward the PCM, whose thermal storage capacity is enhanced by vertical fins attached to the plate. The transient governing equations are solved using the finite element method. A parametric study evaluates the influence of fin shape and number , Reynolds number , obstacle position and inclination (), cavity inclination angle (), block thermal conductivity , and PCM melting temperature (). The results indicate that rectangular fins improve thermal performance, lowering the maximum block temperature by up to 13.67 K compared with triangular fins. Increasing the Reynolds number from 100 to 400 reduces peak temperatures by approximately 4.6%–5.0%. An optimal cavity inclination angle of is identified. In addition, a guiding obstacle at the optimal position effectively directs airflow, reducing the maximum temperature by 4.14%, a moderate fin number (), high block thermal conductivity , and a PCM with a higher melting temperature ( K) significantly enhance cooling efficiency. While increasing the Reynolds number strengthens the average Nusselt number, optimal obstacle configuration maximizes convective heat transfer, whereas larger channel heights tend to weaken it. Overall, the combined action of forced convection, fin‐assisted conduction, and latent heat storage emerges as an efficient approach for thermal management of electronic devices.
- 25 December 2025
- Published by Elsevier in International Communications in Heat and Mass Transfer
- Vol. 172
Mixed convection in a cavity with segmented heated/cooled walls and a rotating fan
- 25 December 2025
- Published by Elsevier in International Communications in Heat and Mass Transfer
- Vol. 172
Mixed convection in a cavity with segmented heated/cooled walls and a rotating fan
- 5 August 2025
- Published by Wiley in Applied Research
- Vol. 4 (4)
Dynamic Heat Dissipation in Electronics Using Nano‐Encapsulated Phase Change Material and Hybrid Convection–Radiation Strategies
Thermal regulation in miniaturized electronics with heterogeneous heat generation profiles has emerged as a pivotal challenge for sustaining performance and reliability in next‐generation technologies. To address these thermal challenges, this study explores an electronic cooling system combining nano‐encapsulated phase change material (NEPCM) with convection–radiation coupling. The system features a partitioned cavity with three different heat‐generating blocks, divided by a conductive plate into an open section (cooled by natural convection and radiation) and a porous closed section saturated with NEPCM. Using the Galerkin finite element method, cooling efficiency is analyzed across critical parameters: PCM properties (melting temperature Tf = 300–315 K, Stefan number Ste = 0.4–1), plate geometry (thickness e = 0.04–0.24 cm, displacement d = 2.7–3.6 cm), radiative effects (emissivity ε = 0.1–0.9), nanoparticle concentration (%), porous media (Da = 10−5–10−2) and the cavity inclination angle ( to ). The findings reveal that the maximum temperatures of the blocks can vary significantly, with reductions exceeding 7% when key parameters, such as Darcy number and cavity inclination angle, are optimized. In contrast, other parameters have a more limited influence, resulting in variations not exceeding 2%. These insights highlight the importance of selecting appropriate parameters for enhanced thermal management in electronic applications.
- 5 August 2025
- Published by Wiley in Applied Research
- Vol. 4 (4)
Dynamic Heat Dissipation in Electronics Using Nano‐Encapsulated Phase Change Material and Hybrid Convection–Radiation Strategies
Thermal regulation in miniaturized electronics with heterogeneous heat generation profiles has emerged as a pivotal challenge for sustaining performance and reliability in next‐generation technologies. To address these thermal challenges, this study explores an electronic cooling system combining nano‐encapsulated phase change material (NEPCM) with convection–radiation coupling. The system features a partitioned cavity with three different heat‐generating blocks, divided by a conductive plate into an open section (cooled by natural convection and radiation) and a porous closed section saturated with NEPCM. Using the Galerkin finite element method, cooling efficiency is analyzed across critical parameters: PCM properties (melting temperature Tf = 300–315 K, Stefan number Ste = 0.4–1), plate geometry (thickness e = 0.04–0.24 cm, displacement d = 2.7–3.6 cm), radiative effects (emissivity ε = 0.1–0.9), nanoparticle concentration (%), porous media (Da = 10−5–10−2) and the cavity inclination angle ( to ). The findings reveal that the maximum temperatures of the blocks can vary significantly, with reductions exceeding 7% when key parameters, such as Darcy number and cavity inclination angle, are optimized. In contrast, other parameters have a more limited influence, resulting in variations not exceeding 2%. These insights highlight the importance of selecting appropriate parameters for enhanced thermal management in electronic applications.
- Open Access
- 24 January 2025
- Published by Wiley
Transient Thermal Cooling of Heat-Generating Blocks with Nano-Encapsulated Phase Change Materials
Optimizing thermal management in electronic components is a critical challenge to ensure reliability and performance in modern technologies. This study investigates an innovative cooling system that integrates Nano-Encapsulated Phase Change Materials (NEPCM) with coupled convection-radiation mechanisms, aiming to address these challenges. The system analyzed consists of a partitioned cavity containing three circular blocks that generate heat varying over time and between blocks, attached to a conductive plate. This plate divides the cavity into two distinct regions: an open section cooled by natural convection and surface radiation, and a porous closed section filled with a combination of NEPCM and a liquid host fluid. The host fluid, water, is enhanced with nanoparticles to improve the thermal performance of the system. Numerical modeling, conducted using the Galerkin finite element method, evaluates the cooling efficiency across a range of parameters, including melting temperature ( 300 K ≤ T f ≤ 315 K ) , Darcy number ( 10 - 5 ≤ Da ≤ 10 - 2 ) , emissivity ( 0 . 1 ≤ ɛ ≤ 0 . 9 ) , Stefan number ( 0 . 4 ≤ Ste ≤ 1 ) , cavity inclination angle (-90° ≤ α ≤ 90°), nanoparticle volume fraction ( 1 % ≤ φ ≤ 6 % ) , as well as the thickness and displacement of the separation plate ( 0 . 04 cm ≤ e ≤ 0 . 24 cm ; 2 . 7 cm ≤ d ≤ 3 . 6 cm ) . The findings reveal that the maximum temperatures of the blocks can vary significantly, with reductions exceeding 7% when key parameters, such as Darcy number and cavity inclination angle, are optimized. In contrast, other parameters have a more limited influence, resulting in variations not exceeding 2%. These insights highlight the importance of selecting appropriate parameters for enhanced thermal management in electronic applications.
- 24 January 2025
- Published by Wiley
Open AccessTransient Thermal Cooling of Heat-Generating Blocks with Nano-Encapsulated Phase Change Materials
Optimizing thermal management in electronic components is a critical challenge to ensure reliability and performance in modern technologies. This study investigates an innovative cooling system that integrates Nano-Encapsulated Phase Change Materials (NEPCM) with coupled convection-radiation mechanisms, aiming to address these challenges. The system analyzed consists of a partitioned cavity containing three circular blocks that generate heat varying over time and between blocks, attached to a conductive plate. This plate divides the cavity into two distinct regions: an open section cooled by natural convection and surface radiation, and a porous closed section filled with a combination of NEPCM and a liquid host fluid. The host fluid, water, is enhanced with nanoparticles to improve the thermal performance of the system. Numerical modeling, conducted using the Galerkin finite element method, evaluates the cooling efficiency across a range of parameters, including melting temperature ( 300 K ≤ T f ≤ 315 K ) , Darcy number ( 10 - 5 ≤ Da ≤ 10 - 2 ) , emissivity ( 0 . 1 ≤ ɛ ≤ 0 . 9 ) , Stefan number ( 0 . 4 ≤ Ste ≤ 1 ) , cavity inclination angle (-90° ≤ α ≤ 90°), nanoparticle volume fraction ( 1 % ≤ φ ≤ 6 % ) , as well as the thickness and displacement of the separation plate ( 0 . 04 cm ≤ e ≤ 0 . 24 cm ; 2 . 7 cm ≤ d ≤ 3 . 6 cm ) . The findings reveal that the maximum temperatures of the blocks can vary significantly, with reductions exceeding 7% when key parameters, such as Darcy number and cavity inclination angle, are optimized. In contrast, other parameters have a more limited influence, resulting in variations not exceeding 2%. These insights highlight the importance of selecting appropriate parameters for enhanced thermal management in electronic applications.