Rachid Hidki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Rachid Hidki has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Zouhair Charqui
Cadi Ayyad University
11 shared publications - Mohammed Boukendil
Cadi Ayyad University
10 shared publications Lahcen El Moutaouakil
Cadi Ayyad Univ, Fac Sci Semlalia, Dept Phys, LMFE,CNRST,URL CNRTST 16, BP 2390, Marrakech, Morocco
6 shared publications- Zaki Zrikem
Cadi Ayyad University
6 shared publications - Abdelhalim Abdelbaki
Cadi Ayyad University
5 shared publications - Lahcen El Moutaouakil
Department of Physics, Fluid Mechanics and Energetic Laboratory Cadi Ayyad University, Faculty of Sciences Semlalia Marrakesh Morocco
5 shared publications
Latest Publications
- 23 April 2026
- Published by Wiley in Energy Storage
- Vol. 8 (4)
Computational Simulation of Natural Convection in a Porous Cavity Packed With a Nano‐Encapsulated Phase Change Material‐Water Mixture and Fitted With an Exothermic Circular Battery Cell
The steady‐state natural convective heat transfer and flow dynamics over a heat‐generating cylindrical battery enclosed in a water‐ nano‐encapsulated phase change material (NEPCM)‐saturated porous cavity are numerically addressed. The generating cell is covered with a thermally conductive material ( copper ). The cavity exhibits left and right vertical walls of constant cold temperature (), and insulated lower and upper walls. Adopting the local thermal equilibrium (LTE) approach among the fluid and the porous structure, the dimensionless Darcy‐Brinkman (DB) equations are numerically handled via the Galerkin weighted residual (GWR) based finite element method (FEM) associated with the Newton–Raphson scheme. The impact of key parameters was thoroughly studied to grasp the flow and heat transfer. The results, illustrated by streamlines, isotherms, heat capacity curves ( melting ‐ solidification zones ), and maximum cell core temperature, highlight the substantive effect of these control parameters. An increase in was shown to significantly improve convection, thereby reducing the cell core temperature. It turned out that an increase in from 10 −5 to 10 −1 decreases by up to 22.6%. Likewise, a rise in porosity () from 0.1 to 0.9 sweeps away an additional reduction of 10.5%. Increasing NEPCM's seeding improves both thermal conduction and latent heat absorption, while a lower improves melting dynamics and thermal response. As for the heat release parameter , its effect seems to be the dominant, with almost linear increases in core temperature as increases. Comparisons to previous research corroborated the current findings. All in all, this study sheds light on the mechanisms of heat transfer in lithium‐ion batteries (LIBs) and/or other thermal energy storage (TES) systems using a water‐NEPCM mixture and paves the way for further application‐based research.
- 23 April 2026
- Published by Wiley in Energy Storage
- Vol. 8 (4)
Computational Simulation of Natural Convection in a Porous Cavity Packed With a Nano‐Encapsulated Phase Change Material‐Water Mixture and Fitted With an Exothermic Circular Battery Cell
The steady‐state natural convective heat transfer and flow dynamics over a heat‐generating cylindrical battery enclosed in a water‐ nano‐encapsulated phase change material (NEPCM)‐saturated porous cavity are numerically addressed. The generating cell is covered with a thermally conductive material ( copper ). The cavity exhibits left and right vertical walls of constant cold temperature (), and insulated lower and upper walls. Adopting the local thermal equilibrium (LTE) approach among the fluid and the porous structure, the dimensionless Darcy‐Brinkman (DB) equations are numerically handled via the Galerkin weighted residual (GWR) based finite element method (FEM) associated with the Newton–Raphson scheme. The impact of key parameters was thoroughly studied to grasp the flow and heat transfer. The results, illustrated by streamlines, isotherms, heat capacity curves ( melting ‐ solidification zones ), and maximum cell core temperature, highlight the substantive effect of these control parameters. An increase in was shown to significantly improve convection, thereby reducing the cell core temperature. It turned out that an increase in from 10 −5 to 10 −1 decreases by up to 22.6%. Likewise, a rise in porosity () from 0.1 to 0.9 sweeps away an additional reduction of 10.5%. Increasing NEPCM's seeding improves both thermal conduction and latent heat absorption, while a lower improves melting dynamics and thermal response. As for the heat release parameter , its effect seems to be the dominant, with almost linear increases in core temperature as increases. Comparisons to previous research corroborated the current findings. All in all, this study sheds light on the mechanisms of heat transfer in lithium‐ion batteries (LIBs) and/or other thermal energy storage (TES) systems using a water‐NEPCM mixture and paves the way for further application‐based research.
- Open Access
Numerical Investigation into 18650 Li-Ion Battery Temperature Control Applying Immersion Cooling with FC-40 Dielectric Fluid
Nowadays, immersion cooling-based battery thermal management systems have demonstrated their effectiveness in controlling the temperature of lithium-ion batteries. While previous scientific research has primarily concentrated on traditional dielectric fluids such as mineral oil, the current research investigates the effectiveness of the dielectric fluid FC-40. A three-dimensional Computational Fluid Dynamics model of an eight-cell 18650 battery system was constructed using ANSYS Fluent 19.2 to examine the effect of cooling fluids (air, mineral oil, and FC-40), velocity of flow (0.01 m/s to 0.15 m/s), discharge rate (1C to 5C), and inlet/outlet size (2.5 mm to 3.5 mm) on thermal efficiency as well as pressure drop. The findings indicate that employing FC-40 as the dielectric fluid significantly reduces the peak cell temperature, with an absolute decrease of 2.80 °C compared to mineral oil and 15.10 °C compared to air. Furthermore, FC-40 achieves the highest uniformity with minimal hotspot. On the other hand, as the fluid velocity increases, the maximum temperature of the battery drops, reaching a minimum of 26 °C at a velocity of 0.15 m/s. Otherwise, at lower flow velocities, the pressure drop remains minimal, thereby reducing the pumping power consumption. Additionally, increasing the inlet and outlet diameter of the fluid directly improves cooling uniformity. Consequently, the temperature dropped by up to 4.3%. Finally, the findings demonstrate that elevated discharge rates contribute to increased heat dissipation but adversely affect the efficiency of the thermal management system. This study provides critical knowledge for the enhancement of battery thermal management systems based on immersion cooling using FC-40 as a dielectric.
Open AccessNumerical Investigation into 18650 Li-Ion Battery Temperature Control Applying Immersion Cooling with FC-40 Dielectric Fluid
Nowadays, immersion cooling-based battery thermal management systems have demonstrated their effectiveness in controlling the temperature of lithium-ion batteries. While previous scientific research has primarily concentrated on traditional dielectric fluids such as mineral oil, the current research investigates the effectiveness of the dielectric fluid FC-40. A three-dimensional Computational Fluid Dynamics model of an eight-cell 18650 battery system was constructed using ANSYS Fluent 19.2 to examine the effect of cooling fluids (air, mineral oil, and FC-40), velocity of flow (0.01 m/s to 0.15 m/s), discharge rate (1C to 5C), and inlet/outlet size (2.5 mm to 3.5 mm) on thermal efficiency as well as pressure drop. The findings indicate that employing FC-40 as the dielectric fluid significantly reduces the peak cell temperature, with an absolute decrease of 2.80 °C compared to mineral oil and 15.10 °C compared to air. Furthermore, FC-40 achieves the highest uniformity with minimal hotspot. On the other hand, as the fluid velocity increases, the maximum temperature of the battery drops, reaching a minimum of 26 °C at a velocity of 0.15 m/s. Otherwise, at lower flow velocities, the pressure drop remains minimal, thereby reducing the pumping power consumption. Additionally, increasing the inlet and outlet diameter of the fluid directly improves cooling uniformity. Consequently, the temperature dropped by up to 4.3%. Finally, the findings demonstrate that elevated discharge rates contribute to increased heat dissipation but adversely affect the efficiency of the thermal management system. This study provides critical knowledge for the enhancement of battery thermal management systems based on immersion cooling using FC-40 as a dielectric.
- 1 December 2023
- Published by Springer Nature
- p. 161-168
Natural Convection and Surface Radiation in a Cavity with a Partially Heated Rectangular Block
- 1 December 2023
- Published by Springer Nature
- p. 161-168
Natural Convection and Surface Radiation in a Cavity with a Partially Heated Rectangular Block
- 1 December 2023
- Published by Springer Nature
- p. 240-248
Influence of Heat Sources/Sinks on Unsteady Natural Convection in a Differentially Heated Enclosure
- 1 December 2023
- Published by Springer Nature
- p. 240-248
Influence of Heat Sources/Sinks on Unsteady Natural Convection in a Differentially Heated Enclosure
- 30 November 2023
- Published by Springer Nature
- p. 235-245
Numerical Analysis of Mixed Convection in a Ventilated Square Cavity Containing a Circular Heat-Generating Cylinder
- 30 November 2023
- Published by Springer Nature
- p. 235-245
Numerical Analysis of Mixed Convection in a Ventilated Square Cavity Containing a Circular Heat-Generating Cylinder
- 15 November 2022
- Published by Wiley in Heat Transfer
- Vol. 52 (3) , 2143-2164
Natural convection coupled to surface radiation in an air‐filled square cavity containing two heat‐generating bodies
The present numerical study focuses on the cooling by natural convection and surface radiation of two electronic components generating two different and uniform volumetric powers. These components are modeled by two square bodies placed inside a closed square cavity with a cold straight wall. Two configurations are analyzed based on the position of the two heat‐generating bodies. In the first one (horizontal position configuration), the two bodies are located at the same height of the cavity, while they are placed at different heights in the second case (vertical position configuration). The effects of two Rayleigh numbers (), the conductivity ratio (), and the emissivity () on the heat transfer characteristics and the flow structure are analyzed. The data is displayed as streamlines, isotherms, velocity, and maximum temperature profiles, and local heat transfer on the active wall. The obtained results indicate that the choice of the appropriate configuration depends mainly on the deviation between the two Rayleigh numbers. Furthermore, the maximum temperature of a specific block decreases as the quantity of heat generated by the other block rises. We can also see that the maximum temperature of the two blocks decreases by about with the increase in the emissivity (from to ) or the conductivity ratio (from to ).
- 15 November 2022
- Published by Wiley in Heat Transfer
- Vol. 52 (3) , 2143-2164
Natural convection coupled to surface radiation in an air‐filled square cavity containing two heat‐generating bodies
The present numerical study focuses on the cooling by natural convection and surface radiation of two electronic components generating two different and uniform volumetric powers. These components are modeled by two square bodies placed inside a closed square cavity with a cold straight wall. Two configurations are analyzed based on the position of the two heat‐generating bodies. In the first one (horizontal position configuration), the two bodies are located at the same height of the cavity, while they are placed at different heights in the second case (vertical position configuration). The effects of two Rayleigh numbers (), the conductivity ratio (), and the emissivity () on the heat transfer characteristics and the flow structure are analyzed. The data is displayed as streamlines, isotherms, velocity, and maximum temperature profiles, and local heat transfer on the active wall. The obtained results indicate that the choice of the appropriate configuration depends mainly on the deviation between the two Rayleigh numbers. Furthermore, the maximum temperature of a specific block decreases as the quantity of heat generated by the other block rises. We can also see that the maximum temperature of the two blocks decreases by about with the increase in the emissivity (from to ) or the conductivity ratio (from to ).