JJJianlong Ji

Jianlong Ji

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jianlong Ji has a total of 7 co-authors. Here are the top co-authors by number of shared publications:

  • Dong Zhao

    Shanxi Key Laboratory of Artificial Intelligences and Micro Nano Sensors, College of Integrated Circuits, Taiyuan University of Technology, Taiyuan 030024, P. R. China

    1 shared publication
  • Feixiang Du

    Tongling University

    1 shared publication
  • Haoyu Wang

    MicroNano System Research Center, Key Lab of Advanced Transducers and Intelligent, Control System of the Ministry of Education & College of Information and Computer, Taiyuan University of Technology, Taiyuan 030024, P. R. China

    1 shared publication
  • Honglie Chen

    MicroNano System Research Center, Key Lab of Advanced Transducers and Intelligent, Control System of the Ministry of Education & College of Information and Computer, Taiyuan University of Technology, Taiyuan 030024, P. R. China

    1 shared publication
  • Shengbo Sang

    Shanxi Key Laboratory of Micro Nano Sensors & Artificial Intelligence Perception, College of Integrated Circuits, Taiyuan University of Technology, Taiyuan, China

    1 shared publication
  • Xing Guo

    Shanxi Key Laboratory of Artificial Intelligences and Micro Nano Sensors, College of Integrated Circuits, Taiyuan University of Technology, Taiyuan 030024, P. R. China

    1 shared publication

Latest Publications

  • AuNPs-PDMS Composite Membrane-Based Surface Stress Biosensor for Molecular Detection

    by Dong Zhao, Honglie Chen, Haoyu Wang, Xing Guo, Yang Ge, Jianlong Ji, Shengbo Sang, Feixiang Du

    Receptor-functionalized membranes provide a new paradigm for developing mechanical biosensors. However, the lower sensitivity of these biosensors is still a challenge. In this research, a sensitive and thin (1.5 [ ]m) gold nanoparticles-polydimethylsiloxane (AuNPs-PDMS) membrane is fabricated by reducing HAuCl4. Experimental results reveal that surface stress deforms the AuNPs-PDMS membrane, further increasing the resistance due to the tunneling mechanism and conductive percolation. During the functional process, the resistance change is consistent with theoretical prediction. The relative resistance change demonstrates a linear relationship with the glucose concentration. The biosensors exhibit a wider linear range for glucose from 0 to 30[ ]mM with a lower detection limit of 0.035[ ]mM. AuNPs-PDMS thin membrane-based surface stress biosensor shows promising application prospects to detect biomolecules.