Lingling Niu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Lingling Niu has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Xingtao Zhou
Eye Institute and Department of Ophthalmology Eye & ENT Hospital, Fudan University Shanghai China
7 shared publications - Yishan Qian
Department of Ophthalmology, Eye and ENT Hospital, Fudan University, Shanghai, People’s Republic of China
3 shared publications Jian Cao
Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, People’s Republic of China
2 shared publications- Jing Zhao
Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China
2 shared publications Peijun Yao
Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, People’s Republic of China
2 shared publicationsTeruko Fukuyama
Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, People’s Republic of China
2 shared publications
Latest Publications
- Open Access
- 28 April 2026
- Published by Springer Nature in BMC Ophthalmology
- Vol. 26 (1) , 225
Comparison of refractive outcomes and visual quality between femtosecond laser-assisted arcuate keratotomy and steep-axis meridian clear corneal incision combined with Implantable Collamer Lens (ICL) implantation for the correction of moderate-to-high myopia and low astigmatism
This study compared refractive outcomes and visual quality between femtosecond laser-assisted arcuate keratotomy (FSAK) and steep-axis meridian clear corne
- 28 April 2026
- Published by Springer Nature in BMC Ophthalmology
- Vol. 26 (1) , 225
Open AccessComparison of refractive outcomes and visual quality between femtosecond laser-assisted arcuate keratotomy and steep-axis meridian clear corneal incision combined with Implantable Collamer Lens (ICL) implantation for the correction of moderate-to-high myopia and low astigmatism
This study compared refractive outcomes and visual quality between femtosecond laser-assisted arcuate keratotomy (FSAK) and steep-axis meridian clear corne
- Open Access
- 1 January 2026
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 20, 1-9
Long-Term Evaluation of Contrast Sensitivity and Vision Quality for High and Extreme High Myopia After EVO ICL Implantation
Purpose: To determine the contrast sensitivity (CS) and vision quality of patients with high and extreme high myopia following long-term evolution implantable collamer lens (EVO ICL) implantation. Patients and Methods: Thirty-five patients (60 eyes) with a myopia range of − 7.25 D to − 18.50 D were enrolled. Participants were categorized into the high myopia (HM) (spherical equivalent>-12.0 D) and extreme high myopia (EHM) (spherical equivalent≤-12.0 D) groups. Routine examinations, including measurements of endothelial cell density and anterior chamber parameters, were performed. CS and vision quality were assessed over a long-term follow-up period, with an average final follow-up time of 7.29± 0.82 years. Results: All surgical procedures were completed without any significant complications. No statistical differences for the CS parameters at the six different spatial frequencies in the corrected and uncorrected conditions were identified between the two groups (P> 0.05). The vision quality questionnaire results indicated both groups reported concerns regarding the frequency of halos (HM group 57.6%, EHM group 63%). Driving was identified as the most distressing postoperative daily life activity. Further analysis revealed a negative correlation between driving distress and CS (B=− 0.40, P< 0.01). The preoperative axial length was found to be correlated with CS (B=− 0.39, P< 0.01). Conclusion: Patients with HM and EHM maintained good long-term CS and vision quality after EVO ICL implantation. Halos and driving distress were the most common complaints.
- 1 January 2026
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 20, 1-9
Open AccessLong-Term Evaluation of Contrast Sensitivity and Vision Quality for High and Extreme High Myopia After EVO ICL Implantation
Purpose: To determine the contrast sensitivity (CS) and vision quality of patients with high and extreme high myopia following long-term evolution implantable collamer lens (EVO ICL) implantation. Patients and Methods: Thirty-five patients (60 eyes) with a myopia range of − 7.25 D to − 18.50 D were enrolled. Participants were categorized into the high myopia (HM) (spherical equivalent>-12.0 D) and extreme high myopia (EHM) (spherical equivalent≤-12.0 D) groups. Routine examinations, including measurements of endothelial cell density and anterior chamber parameters, were performed. CS and vision quality were assessed over a long-term follow-up period, with an average final follow-up time of 7.29± 0.82 years. Results: All surgical procedures were completed without any significant complications. No statistical differences for the CS parameters at the six different spatial frequencies in the corrected and uncorrected conditions were identified between the two groups (P> 0.05). The vision quality questionnaire results indicated both groups reported concerns regarding the frequency of halos (HM group 57.6%, EHM group 63%). Driving was identified as the most distressing postoperative daily life activity. Further analysis revealed a negative correlation between driving distress and CS (B=− 0.40, P< 0.01). The preoperative axial length was found to be correlated with CS (B=− 0.39, P< 0.01). Conclusion: Patients with HM and EHM maintained good long-term CS and vision quality after EVO ICL implantation. Halos and driving distress were the most common complaints.
- Open Access
- 1 October 2025
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 19, 4001-4009
Brillouin Metrics of the Crystalline Lens Comparison Between Low-Medium Myopia and High Myopia
Purpose: To investigate the impact of myopia on the Brillouin biomechanics and morphology of crystalline lenses in Chinese adults. Methods: Patients with myopia were enrolled and divided into low-medium (spherical equivalent [SE] ≥ − 5.75 D, N = 66) and high (SE ≤ – 6.0 D, N = 72) myopia groups. All patients underwent routine ophthalmic examinations, including SE, axial length, and anterior chamber metrics (Pentacam) measurements. The Brillouin-related metrics of the crystalline lenses were measured using a Brillouin microscopy. The morphological parameters included the Width of Top Plateau (WTP), Width of Bottom Plateau (WBP), Bottom-Top (B-T), Slope of Anterior Cortex (SAC), and Slope of Posterior Cortex (SPC). The height of Plateau was a biomechanical parameter. Results: The study included 138 eyes (138 patients); the mean age was 28.43 ± 8.31 years. WBP, B-T, SAC, and SPC significantly differed between the high and low-medium myopia groups (all P< 0.05). WBP, B-T, and SPC significantly correlated with SE in the high myopia group (Pearson’s r = 0.365, 0.287, and 0.294, respectively; all P< 0.05) but not in the low-medium group. The SPC significantly decreased for all participants based on the SE values (P< 0.05). The biomechanics and thickness of the nucleus displayed no discrepancies with SE in all participants (all P > 0.05). Conclusion: An increase in the degree of myopia could be associated with posterior cortex thickening while maintaining stable biomechanics and morphology of the crystalline lens nucleus. Brillouin microscopy can serve as an effective technique for multidisciplinary lens biomechanical and morphological imaging.
- 1 October 2025
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 19, 4001-4009
Open AccessBrillouin Metrics of the Crystalline Lens Comparison Between Low-Medium Myopia and High Myopia
Purpose: To investigate the impact of myopia on the Brillouin biomechanics and morphology of crystalline lenses in Chinese adults. Methods: Patients with myopia were enrolled and divided into low-medium (spherical equivalent [SE] ≥ − 5.75 D, N = 66) and high (SE ≤ – 6.0 D, N = 72) myopia groups. All patients underwent routine ophthalmic examinations, including SE, axial length, and anterior chamber metrics (Pentacam) measurements. The Brillouin-related metrics of the crystalline lenses were measured using a Brillouin microscopy. The morphological parameters included the Width of Top Plateau (WTP), Width of Bottom Plateau (WBP), Bottom-Top (B-T), Slope of Anterior Cortex (SAC), and Slope of Posterior Cortex (SPC). The height of Plateau was a biomechanical parameter. Results: The study included 138 eyes (138 patients); the mean age was 28.43 ± 8.31 years. WBP, B-T, SAC, and SPC significantly differed between the high and low-medium myopia groups (all P< 0.05). WBP, B-T, and SPC significantly correlated with SE in the high myopia group (Pearson’s r = 0.365, 0.287, and 0.294, respectively; all P< 0.05) but not in the low-medium group. The SPC significantly decreased for all participants based on the SE values (P< 0.05). The biomechanics and thickness of the nucleus displayed no discrepancies with SE in all participants (all P > 0.05). Conclusion: An increase in the degree of myopia could be associated with posterior cortex thickening while maintaining stable biomechanics and morphology of the crystalline lens nucleus. Brillouin microscopy can serve as an effective technique for multidisciplinary lens biomechanical and morphological imaging.
- Open Access
- 1 October 2025
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 19, 3761-3771
Evaluating Corneal Optical Density and Subbasal Nerve Fiber Metrics in Myopic Patients
Aim: To assess corneal metrics in myopic patients and investigate the relationship between myopia severity and corneal characteristics. Methods: Consecutive myopic patients undergoing preoperative evaluations for refractive surgery were enrolled. Comprehensive clinical data, including age, gender, axial length (AL), and spherical equivalent refraction (SER) were collected. All enrolled patients completed the ocular surface disease index (OSDI) questionnaire. Myopia severity was categorized based on SER and AL. Detailed corneal optical density (COD) was measured using Pentacam HR imaging. In vivo confocal microscopy (IVCM) was performed to measure central corneal sub-basal nerve plexus (SNP) and dendritiform cell (DC) density. Correlations among metrics were analyzed, and differences across various levels of myopia severity were assessed. Results: The study included 157 participants (308 eyes), predominantly female (118 females, 39 males), with a mean age of 28.0 ± 6.64 years (range 17– 52). The mean SER was − 6.85 ± 3.0 D (range − 18.00 to − 0.50 D), and the mean AL was 26.32 ± 1.4 mm (range 22.92– 30.42 mm). OSDI showed a positive correlation with corneal nerve branch density (CNBD). Age correlated significantly with COD in the 6– 10 mm zones of the anterior, middle, posterior and total layers (all P < 0.05), as well as in the 10– 12 mm zones of the middle (P = 0.020) and total layers (P = 0.023), but showed no impact on SNP metrics. DC density exhibited a correlation with SNP metrics. Central COD (0– 6 mm zone) increased with myopia severity, showing a negative correlation with SER and positive correlations with AL, with significant changes observed in the middle, posterior, and total corneal layers. No significant effects of myopia severity were observed on SNP metrics. Conclusion: This study highlights complex relationships between corneal metrics in myopic patients. COD values in the central 0– 6 mm zone increased with higher myopia severity, while no significant relationships were found with SNP metrics.
- 1 October 2025
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 19, 3761-3771
Open AccessEvaluating Corneal Optical Density and Subbasal Nerve Fiber Metrics in Myopic Patients
Aim: To assess corneal metrics in myopic patients and investigate the relationship between myopia severity and corneal characteristics. Methods: Consecutive myopic patients undergoing preoperative evaluations for refractive surgery were enrolled. Comprehensive clinical data, including age, gender, axial length (AL), and spherical equivalent refraction (SER) were collected. All enrolled patients completed the ocular surface disease index (OSDI) questionnaire. Myopia severity was categorized based on SER and AL. Detailed corneal optical density (COD) was measured using Pentacam HR imaging. In vivo confocal microscopy (IVCM) was performed to measure central corneal sub-basal nerve plexus (SNP) and dendritiform cell (DC) density. Correlations among metrics were analyzed, and differences across various levels of myopia severity were assessed. Results: The study included 157 participants (308 eyes), predominantly female (118 females, 39 males), with a mean age of 28.0 ± 6.64 years (range 17– 52). The mean SER was − 6.85 ± 3.0 D (range − 18.00 to − 0.50 D), and the mean AL was 26.32 ± 1.4 mm (range 22.92– 30.42 mm). OSDI showed a positive correlation with corneal nerve branch density (CNBD). Age correlated significantly with COD in the 6– 10 mm zones of the anterior, middle, posterior and total layers (all P < 0.05), as well as in the 10– 12 mm zones of the middle (P = 0.020) and total layers (P = 0.023), but showed no impact on SNP metrics. DC density exhibited a correlation with SNP metrics. Central COD (0– 6 mm zone) increased with myopia severity, showing a negative correlation with SER and positive correlations with AL, with significant changes observed in the middle, posterior, and total corneal layers. No significant effects of myopia severity were observed on SNP metrics. Conclusion: This study highlights complex relationships between corneal metrics in myopic patients. COD values in the central 0– 6 mm zone increased with higher myopia severity, while no significant relationships were found with SNP metrics.
- Open Access
- 16 July 2024
- Published by Springer Nature in BMC Ophthalmology
- Vol. 24 (1) , 1-8
Comparison of axial length and anterior segment parameters of patients with myopia measured using 2 fourier-domain optical coherent biometry devices
Background: This study assessed the agreement of ocular parameters of patients with myopia measured using Colombo intraocular lens (IOL) 2 and IOLMaster 700. Methods: Eighty patients (male, 22; average age, 29.14 ± 7.36 years) with myopia (159 eyes) were included in this study in May 2023. The participants’ axial length (AXL), central corneal thickness (CCT), lens thickness (LT), white-to-white distance (WTW), front flat (K1), steep (K2), mean (Km) corneal keratometry, astigmatism (Astig), J0 vector, and J45 vector were measured using the IOLMaster 700 and Colombo IOL 2. The measurements from both devices were compared using the generalized estimating equation, correlation analysis, and Bland-Altman plots. Results: With the Colombo IOL 2, lower values for K2 and J0 (odds ratio [OR] = 0.587, p = 0.033; OR = 0.779, p < 0.0001, respectively), and larger values for WTW, Astig, and J45 (OR = 1.277, OR = 1.482, OR = 1.1, all p < 0.0001) were obtained. All ocular measurements by both instruments showed positive correlations, with AXL demonstrating the strongest correlation (r = 0.9996, p < 0.0001). The intraclass correlation coefficients for AXL and CCT measured by both instruments was 0.999 and 0.988 (both p < 0.0001), and Bland-Altman plot showed 95% limits of agreement (LoA) of -0.078 to 0.11 mm and − 9.989 to 13.486 μm, respectively. The maximum absolute 95% LoA for LT, WTW, K1, K2, and J0 were relatively high, achieving 0.829 mm, 0.717 mm, 0.983 D, 0.948 D, and 0.632 D, respectively. Conclusions: In young patients with myopia, CCT and AXL measurements obtained with the Colombo IOL 2 and IOLMaster 700 were comparable. However, WTW, LT, corneal refractive power, and astigmatism values could not be used interchangeably in clinical practice.
- 16 July 2024
- Published by Springer Nature in BMC Ophthalmology
- Vol. 24 (1) , 1-8
Open AccessComparison of axial length and anterior segment parameters of patients with myopia measured using 2 fourier-domain optical coherent biometry devices
Background: This study assessed the agreement of ocular parameters of patients with myopia measured using Colombo intraocular lens (IOL) 2 and IOLMaster 700. Methods: Eighty patients (male, 22; average age, 29.14 ± 7.36 years) with myopia (159 eyes) were included in this study in May 2023. The participants’ axial length (AXL), central corneal thickness (CCT), lens thickness (LT), white-to-white distance (WTW), front flat (K1), steep (K2), mean (Km) corneal keratometry, astigmatism (Astig), J0 vector, and J45 vector were measured using the IOLMaster 700 and Colombo IOL 2. The measurements from both devices were compared using the generalized estimating equation, correlation analysis, and Bland-Altman plots. Results: With the Colombo IOL 2, lower values for K2 and J0 (odds ratio [OR] = 0.587, p = 0.033; OR = 0.779, p < 0.0001, respectively), and larger values for WTW, Astig, and J45 (OR = 1.277, OR = 1.482, OR = 1.1, all p < 0.0001) were obtained. All ocular measurements by both instruments showed positive correlations, with AXL demonstrating the strongest correlation (r = 0.9996, p < 0.0001). The intraclass correlation coefficients for AXL and CCT measured by both instruments was 0.999 and 0.988 (both p < 0.0001), and Bland-Altman plot showed 95% limits of agreement (LoA) of -0.078 to 0.11 mm and − 9.989 to 13.486 μm, respectively. The maximum absolute 95% LoA for LT, WTW, K1, K2, and J0 were relatively high, achieving 0.829 mm, 0.717 mm, 0.983 D, 0.948 D, and 0.632 D, respectively. Conclusions: In young patients with myopia, CCT and AXL measurements obtained with the Colombo IOL 2 and IOLMaster 700 were comparable. However, WTW, LT, corneal refractive power, and astigmatism values could not be used interchangeably in clinical practice.
- Open Access
- 1 March 2024
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 50 (3) , 276-282
Risk factors associated with haptic malposition in eyes implanted with implantable collamer lenses
Purpose: To examine the risk factors for haptic malposition in eyes with implantable collamer lens (ICL). Setting: Eye and ENT Hospital, Fudan University, Shanghai, China. Design: Prospective nonrandomized observational study. Methods: This study included 134 (77.9%) of 172 initially enrolled patients who underwent ICL implantation and completed a 1-year follow-up. The extent of haptics present in the ciliary sulcus (ICS) was measured. Patients were categorized based on ICS count (0 to 4). The position of the haptics was quantified as the distance between the iris root and the terminal tip of ICL haptics (iris root to haptic tip, IRH). The related factors to the ICS count and its correlation with the central vault were analyzed. Results: ICS distribution was 0 ICS in 19 eyes (14.2%), 1 in 22 eyes (16.4%), 2 in 32 eyes (23.9%), 3 in 29 eyes (21.6%), and 4 in 32 eyes (23.9%). Parameters like maximum ciliary body thickness (CBTmax, P = .008), iris–ciliary process distance (ICPD, P < .001), and ciliary process length (P = .034) varied significantly across ICS groups. A multiple linear regression analysis revealed that the iris–ciliary angle (P = .006), CBTmax (P = .007), the distance between the sulcus-to-sulcus plane and the anterior crystalline lens surface (STSL, P = .035), and ICL size (P = .015) were significantly associated with IRH. Spherical equivalents (P = .042), STSL (P = .001), and ICS count (P = .020) significantly correlated with the central vault. Conclusions: Shortened ciliary process is a primary risk for haptic malposition. The ICS count significantly relates to the central vault.
- 1 March 2024
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 50 (3) , 276-282
Open AccessRisk factors associated with haptic malposition in eyes implanted with implantable collamer lenses
Purpose: To examine the risk factors for haptic malposition in eyes with implantable collamer lens (ICL). Setting: Eye and ENT Hospital, Fudan University, Shanghai, China. Design: Prospective nonrandomized observational study. Methods: This study included 134 (77.9%) of 172 initially enrolled patients who underwent ICL implantation and completed a 1-year follow-up. The extent of haptics present in the ciliary sulcus (ICS) was measured. Patients were categorized based on ICS count (0 to 4). The position of the haptics was quantified as the distance between the iris root and the terminal tip of ICL haptics (iris root to haptic tip, IRH). The related factors to the ICS count and its correlation with the central vault were analyzed. Results: ICS distribution was 0 ICS in 19 eyes (14.2%), 1 in 22 eyes (16.4%), 2 in 32 eyes (23.9%), 3 in 29 eyes (21.6%), and 4 in 32 eyes (23.9%). Parameters like maximum ciliary body thickness (CBTmax, P = .008), iris–ciliary process distance (ICPD, P < .001), and ciliary process length (P = .034) varied significantly across ICS groups. A multiple linear regression analysis revealed that the iris–ciliary angle (P = .006), CBTmax (P = .007), the distance between the sulcus-to-sulcus plane and the anterior crystalline lens surface (STSL, P = .035), and ICL size (P = .015) were significantly associated with IRH. Spherical equivalents (P = .042), STSL (P = .001), and ICS count (P = .020) significantly correlated with the central vault. Conclusions: Shortened ciliary process is a primary risk for haptic malposition. The ICS count significantly relates to the central vault.
- Open Access
- 16 January 2024
- Published by Taylor & Francis in Clinical and Experimental Optometry
- Vol. 107 (8) , 788-794
Influence of corneal diameter on the accuracy of corneal tomography in patients with forme fruste keratoconus or thin corneas
The detection of subclinical ectasia is important in preoperative screening for laser-refractive surgery. Previous studies have confirmed the impact of corneal diameter on the diagnostic accuracy of several ectasia indices in tomographically normal eyes. This study aimed to investigate the influence of corneal diameter on the diagnostic accuracy of Pentacam tomographic indices in eyes with forme fruste keratoconus (FFKC) and thin corneas. One hundred and one eyes of 101 patients with FFKC (FFKC group), 104 eyes of 104 patients with a corneal thickness p < 0.001). Comparing for the classifications (normal versus abnormal) of the individual indices demonstrated that for corneal diameters ≤11.9 mm, the rates of abnormal cases were significantly higher in the FFKC group than in the normal group for seven indices and in the thin cornea group than normal group for nine indices. For corneal diameters >11.9 mm, the rates of abnormal cases were higher in the FFKC than normal group for three indices and higher in the thin cornea group than normal group for seven indices. Belin/Ambrosio Enhanced Ectasia display indices may underestimate the risk of ectasia in patients with large corneas, especially those with FFKC.
- 16 January 2024
- Published by Taylor & Francis in Clinical and Experimental Optometry
- Vol. 107 (8) , 788-794
Open AccessInfluence of corneal diameter on the accuracy of corneal tomography in patients with forme fruste keratoconus or thin corneas
The detection of subclinical ectasia is important in preoperative screening for laser-refractive surgery. Previous studies have confirmed the impact of corneal diameter on the diagnostic accuracy of several ectasia indices in tomographically normal eyes. This study aimed to investigate the influence of corneal diameter on the diagnostic accuracy of Pentacam tomographic indices in eyes with forme fruste keratoconus (FFKC) and thin corneas. One hundred and one eyes of 101 patients with FFKC (FFKC group), 104 eyes of 104 patients with a corneal thickness p < 0.001). Comparing for the classifications (normal versus abnormal) of the individual indices demonstrated that for corneal diameters ≤11.9 mm, the rates of abnormal cases were significantly higher in the FFKC group than in the normal group for seven indices and in the thin cornea group than normal group for nine indices. For corneal diameters >11.9 mm, the rates of abnormal cases were higher in the FFKC than normal group for three indices and higher in the thin cornea group than normal group for seven indices. Belin/Ambrosio Enhanced Ectasia display indices may underestimate the risk of ectasia in patients with large corneas, especially those with FFKC.
- Open Access
- 16 October 2022
- Published by Springer Nature in Ophthalmology and Therapy
- Vol. 12 (1) , 125-138
Comparison of Two Scheimpflug Systems in the Measurements of Eyes with Corneal Diameter Smaller than 11.1 mm
Introduction This article aimed to evaluate the measurements of ectasia parameters by two Scheimpflug-based tomography devices, Pentacam and Sirius, for eyes with different corneal diameters (CDs). Methods This cross-sectional research included subjects from the Fudan University EENT Hospital Refractive Center Database that were followed once a year for at least 3 years with unremarkable slit-lamp examination and normal topography. Pentacam and Sirius examinations were performed on these subjects and the ectasia indices were compared between different CD groups. Results The right eyes of 153 subjects were included (CD ≤ 11.1 mm, n = 50; 11.2–12 mm, n = 52; > 12.0 mm, n = 51). For the ectasia parameters from Pentacam, CD had the greatest influence on the deviation of normality of back elevation (Db, R2 = 0.371, β = − 1.119, P < 0.001), overall deviation of normality (BAD-D, R2 = 0.305, β = − 0.589, P < 0.001), and minimum pachymetric progression index (PPImin, R2 = 0.282, β = − 0.131, P < 0.001). For parameters derived from Sirius, CD had the greatest influence on Baiocchi–Calossi–Versaci index of the back surface (BCVb, R2 = 0.138, β = − 0.179, P < 0.001), keratoconus vertex of the back surface (KVb, R2 = 0.099, β = − 2.273, P < 0.001), and BCV (R2 = 0.071, β = − 0.078, P = 0.001). CD had little influence on surface asymmetry index of the front (SIf) and back surface (SIb), keratoconus vertex of the front surface (KVf), Baiocchi–Calossi–Versaci index of the front surface (BCVf), and Sirius classifier (P > 0.05). Conclusions For Pentacam, CD mainly influenced indices related to back elevation (BE) and pachymetry progression, whereas for Sirius, CD mainly influenced indices related to BE and corneal aberration.
- 16 October 2022
- Published by Springer Nature in Ophthalmology and Therapy
- Vol. 12 (1) , 125-138
Open AccessComparison of Two Scheimpflug Systems in the Measurements of Eyes with Corneal Diameter Smaller than 11.1 mm
Introduction This article aimed to evaluate the measurements of ectasia parameters by two Scheimpflug-based tomography devices, Pentacam and Sirius, for eyes with different corneal diameters (CDs). Methods This cross-sectional research included subjects from the Fudan University EENT Hospital Refractive Center Database that were followed once a year for at least 3 years with unremarkable slit-lamp examination and normal topography. Pentacam and Sirius examinations were performed on these subjects and the ectasia indices were compared between different CD groups. Results The right eyes of 153 subjects were included (CD ≤ 11.1 mm, n = 50; 11.2–12 mm, n = 52; > 12.0 mm, n = 51). For the ectasia parameters from Pentacam, CD had the greatest influence on the deviation of normality of back elevation (Db, R2 = 0.371, β = − 1.119, P < 0.001), overall deviation of normality (BAD-D, R2 = 0.305, β = − 0.589, P < 0.001), and minimum pachymetric progression index (PPImin, R2 = 0.282, β = − 0.131, P < 0.001). For parameters derived from Sirius, CD had the greatest influence on Baiocchi–Calossi–Versaci index of the back surface (BCVb, R2 = 0.138, β = − 0.179, P < 0.001), keratoconus vertex of the back surface (KVb, R2 = 0.099, β = − 2.273, P < 0.001), and BCV (R2 = 0.071, β = − 0.078, P = 0.001). CD had little influence on surface asymmetry index of the front (SIf) and back surface (SIb), keratoconus vertex of the front surface (KVf), Baiocchi–Calossi–Versaci index of the front surface (BCVf), and Sirius classifier (P > 0.05). Conclusions For Pentacam, CD mainly influenced indices related to back elevation (BE) and pachymetry progression, whereas for Sirius, CD mainly influenced indices related to BE and corneal aberration.
- Open Access
- 8 August 2019
- Published by Springer Nature in BMC Ophthalmology
- Vol. 19 (1) , 1-5
Two-year outcome of an eye that underwent hyperopic LASIK following inadvertent myopic SMILE lenticule in situ implantation
This report describes a case in which hyperopic femtosecond laser-assisted in situ keratomileusis (FS-LASIK) was performed following small incision lenticule extraction (SMILE) lenticule in situ implantation. The hyperopic left eye of a 46-year-old patient with refraction of + 7.75 diopters sphere (DS)/− 1.25 diopters cylinder (DC) × 5° and corrected distance visual acuity (CDVA) of 20/50 mistakenly underwent the SMILE procedure for myopic astigmatism (− 8.50 DS/− 1.50 DC × 175°) due to medical negligence. The extracted lenticule was subsequently re-implanted in situ. After 8 months, the left eye underwent FS-LASIK to correct hyperopia and astigmatism (+ 5.0 DS/− 0.75 DC × 100°). Two years after FS-LASIK, corneal tomography showed no ectasia and microscopy revealed transparent cornea. The left eye exhibited CDVA of 20/50 with refraction of − 0.75 DS/− 0.25 DC × 165°. SMILE lenticule in situ implantation offers a solution for corneal volume and thickness restoration. FS-LASIK provides feasible correction of refractive error following lenticule re-implantation. Future studies are needed for determining the effectiveness of the treatment.
- 8 August 2019
- Published by Springer Nature in BMC Ophthalmology
- Vol. 19 (1) , 1-5
Open AccessTwo-year outcome of an eye that underwent hyperopic LASIK following inadvertent myopic SMILE lenticule in situ implantation
This report describes a case in which hyperopic femtosecond laser-assisted in situ keratomileusis (FS-LASIK) was performed following small incision lenticule extraction (SMILE) lenticule in situ implantation. The hyperopic left eye of a 46-year-old patient with refraction of + 7.75 diopters sphere (DS)/− 1.25 diopters cylinder (DC) × 5° and corrected distance visual acuity (CDVA) of 20/50 mistakenly underwent the SMILE procedure for myopic astigmatism (− 8.50 DS/− 1.50 DC × 175°) due to medical negligence. The extracted lenticule was subsequently re-implanted in situ. After 8 months, the left eye underwent FS-LASIK to correct hyperopia and astigmatism (+ 5.0 DS/− 0.75 DC × 100°). Two years after FS-LASIK, corneal tomography showed no ectasia and microscopy revealed transparent cornea. The left eye exhibited CDVA of 20/50 with refraction of − 0.75 DS/− 0.25 DC × 165°. SMILE lenticule in situ implantation offers a solution for corneal volume and thickness restoration. FS-LASIK provides feasible correction of refractive error following lenticule re-implantation. Future studies are needed for determining the effectiveness of the treatment.