Vladyslav Tsiupa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Vladyslav Tsiupa has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Dmytro Danylchenko
National Technical University “Kharkiv Polytechnic Institute
5 shared publications - Andrii Potryvai
Національний технічний університет «Харківський політехнічний інститут», Україна image/svg+xml
1 shared publication - Katarzyna Piotrowska
Lublin University of Technology
1 shared publication - Oleksandr Miroshnyk
State Biotechnological University
1 shared publication - Sergii Shevchenko
National Technical University “Kharkiv Polytechnic Institute
1 shared publication - Stanislav Dryvetskyi
National Technical University “Kharkiv Polytechnic Institute
1 shared publication
Latest Publications
- Open Access
- 30 September 2026
- Published by Politechnika Lubelska in Applied Computer Science
- Vol. 22 (3) , 82-96
Digitalisation of relay protection and implementation of main protections in digital form
This paper presents a Java-based software demonstration of overcurrent, transformer differential, and distance protection. Its contribution is an implementation-oriented treatment of three complementary protection functions, with explicit signal-processing, decision, and timing logic. The transformer differential component builds on the authors’ earlier study; the present scope also includes four-stage overcurrent logic and a comparison of polygonal and circular distance characteristics. The methodology combines a scalar overcurrent example with offline processing of fault records for the other functions. Measurements of the Java implementation yielded approximately 30–70 ms operating time, 5–20 µs processing time per sample, and a JVM memory footprint of approximately 30–80 MB. At the adopted 4 kHz sampling rate, the reported per-sample processing time corresponds to 2–8% of the 250 µs sampling interval. These measurements support computational feasibility under the tested conditions, while qualitative timing variability remains a limitation. The results do not establish a worst-case execution bound, statistical reliability, or compliance with protection-equipment standards.
- 30 September 2026
- Published by Politechnika Lubelska in Applied Computer Science
- Vol. 22 (3) , 82-96
Open AccessDigitalisation of relay protection and implementation of main protections in digital form
This paper presents a Java-based software demonstration of overcurrent, transformer differential, and distance protection. Its contribution is an implementation-oriented treatment of three complementary protection functions, with explicit signal-processing, decision, and timing logic. The transformer differential component builds on the authors’ earlier study; the present scope also includes four-stage overcurrent logic and a comparison of polygonal and circular distance characteristics. The methodology combines a scalar overcurrent example with offline processing of fault records for the other functions. Measurements of the Java implementation yielded approximately 30–70 ms operating time, 5–20 µs processing time per sample, and a JVM memory footprint of approximately 30–80 MB. At the adopted 4 kHz sampling rate, the reported per-sample processing time corresponds to 2–8% of the 250 µs sampling interval. These measurements support computational feasibility under the tested conditions, while qualitative timing variability remains a limitation. The results do not establish a worst-case execution bound, statistical reliability, or compliance with protection-equipment standards.
- Open Access
- 30 December 2025
- Published by National Technical University Kharkiv Polytechnic Institute in Bulletin of the National Technical University "KhPI". Series: Energy: Reliability and Energy Efficiency
- No. 2(11),p. 18-24
Application of artificial neural networks in relay protection systems of power supply networks for fault condition recognition
The paper investigates the possibility of applying artificial neural networks in relay protection systems of power supply networks in order to improve the reliability, speed, and adaptability of recognizing emergency and pre-emergency operating conditions. It is shown that conventional relay protection devices based on fixed settings and logical algorithms have limited capability to adapt to changes in power system parameters, network topology, and load conditions, which may lead to false or unnecessary operations. To address this problem, a neural network-based approach is proposed, relying on the analysis of instantaneous values of phase currents and voltages. A simulation model of the power supply system was developed in the MATLAB/Simulink environment using standard electrical component libraries. During the simulation process, normal and fault operating modes were reproduced, including conditions caused by single-phase short circuits, which enabled the formation of representative training and testing datasets. The paper presents the structure of the artificial neural network, describes the training process using the backpropagation algorithm, and analyzes the convergence of the training procedure based on the mean squared error criterion. Testing of the trained neural network model was performed, and the retraining process under changing power system parameters was also investigated. The obtained results confirm the ability of the neural network to effectively recognize operating modes of the power supply system and to maintain correct performance after retraining. It is concluded that the application of artificial neural networks as an intelligent element of relay protection systems is a promising approach for increasing their adaptability, reducing the probability of false operations, and ensuring stable operation of power systems under varying operating conditions.
- 30 December 2025
- Published by National Technical University Kharkiv Polytechnic Institute in Bulletin of the National Technical University "KhPI". Series: Energy: Reliability and Energy Efficiency
- No. 2(11),p. 18-24
Open AccessApplication of artificial neural networks in relay protection systems of power supply networks for fault condition recognition
The paper investigates the possibility of applying artificial neural networks in relay protection systems of power supply networks in order to improve the reliability, speed, and adaptability of recognizing emergency and pre-emergency operating conditions. It is shown that conventional relay protection devices based on fixed settings and logical algorithms have limited capability to adapt to changes in power system parameters, network topology, and load conditions, which may lead to false or unnecessary operations. To address this problem, a neural network-based approach is proposed, relying on the analysis of instantaneous values of phase currents and voltages. A simulation model of the power supply system was developed in the MATLAB/Simulink environment using standard electrical component libraries. During the simulation process, normal and fault operating modes were reproduced, including conditions caused by single-phase short circuits, which enabled the formation of representative training and testing datasets. The paper presents the structure of the artificial neural network, describes the training process using the backpropagation algorithm, and analyzes the convergence of the training procedure based on the mean squared error criterion. Testing of the trained neural network model was performed, and the retraining process under changing power system parameters was also investigated. The obtained results confirm the ability of the neural network to effectively recognize operating modes of the power supply system and to maintain correct performance after retraining. It is concluded that the application of artificial neural networks as an intelligent element of relay protection systems is a promising approach for increasing their adaptability, reducing the probability of false operations, and ensuring stable operation of power systems under varying operating conditions.
- Open Access
- 22 October 2025
- Published by National University "Zaporizhzhia Polytechnic" in Electrical Engineering and Power Engineering
- No. 3,p. 52-60
Way to implementation in relay protection of the algorithm for searching for pre-fault operating conditions by using a neural network with backpropagation spot training
Purpose. The purpose of this paper is to develop and validate a novel method for searching critical and pre-fault operating conditions in power systems for relay protection setting calculation. The proposed approach is based on the integration of graph neural networks with deep reinforcement learning (GNN-DRL) and aims to significantly reduce computational time while maintaining high accuracy and ensuring protection selectivity. Findings. It is demonstrated that the proposed GNN-DRL method achieves a 10–1000 times reduction in computational overhead compared to traditional brute-force approaches. The prediction accuracy exceeds 90%, while e-accuracy surpasses 98%. The method proves to be highly effective both in determining maximum fault currents for instantaneous overcurrent protection and in large-scale scenarios on extended test systems. Originality. For the first time, the integration of graph neural networks with the Dueling Double Deep Q Network algorithm is proposed to solve the problem of searching for critical and pre-fault operating conditions in relay protection. A unique two-stage training framework, GLFE, is developed, combining elements of supervised and unsupervised learning. This enables high prediction accuracy while requiring significantly fewer training samples. Practical value. The results of this study can be applied in the design of intelligent relay protection and automation systems for electric power networks. The proposed method is capable of adapting to fast-changing conditions in power systems with high penetration of renewable energy. Furthermore, the architecture can be extended to other optimization and control problems in complex energy environments.
- 22 October 2025
- Published by National University "Zaporizhzhia Polytechnic" in Electrical Engineering and Power Engineering
- No. 3,p. 52-60
Open AccessWay to implementation in relay protection of the algorithm for searching for pre-fault operating conditions by using a neural network with backpropagation spot training
Purpose. The purpose of this paper is to develop and validate a novel method for searching critical and pre-fault operating conditions in power systems for relay protection setting calculation. The proposed approach is based on the integration of graph neural networks with deep reinforcement learning (GNN-DRL) and aims to significantly reduce computational time while maintaining high accuracy and ensuring protection selectivity. Findings. It is demonstrated that the proposed GNN-DRL method achieves a 10–1000 times reduction in computational overhead compared to traditional brute-force approaches. The prediction accuracy exceeds 90%, while e-accuracy surpasses 98%. The method proves to be highly effective both in determining maximum fault currents for instantaneous overcurrent protection and in large-scale scenarios on extended test systems. Originality. For the first time, the integration of graph neural networks with the Dueling Double Deep Q Network algorithm is proposed to solve the problem of searching for critical and pre-fault operating conditions in relay protection. A unique two-stage training framework, GLFE, is developed, combining elements of supervised and unsupervised learning. This enables high prediction accuracy while requiring significantly fewer training samples. Practical value. The results of this study can be applied in the design of intelligent relay protection and automation systems for electric power networks. The proposed method is capable of adapting to fast-changing conditions in power systems with high penetration of renewable energy. Furthermore, the architecture can be extended to other optimization and control problems in complex energy environments.
- Open Access
- 9 July 2025
- Published by National Technical University Kharkiv Polytechnic Institute in Bulletin of the National Technical University "KhPI". Series: Energy: Reliability and Energy Efficiency
- No. 1(10),p. 40-46
Method of implementing digitisation of relay protection and automation for power distribution facilities with a voltage of 6-10 kV
The paper presents a new concept for designing a centralized multi-channel control system for medium-voltage switchgear, the main innovation of which is the integration of primary and backup relay protection algorithms into the substation's computing infrastructure, namely, into a backup or redundant server unit known as the Front-End Controller. This architecture is aimed at improving the cost-effectiveness and practical operation of relay protection and automation solutions for energy companies and grid operators. The proposed approach is particularly applicable to the most common types of medium-voltage distribution networks, as well as to power supply systems at industrial enterprises. By moving the protection logic from distributed hardware relays to a central computing node, the system provides a more flexible implementation of modern adaptive relay protection and automation algorithms, which facilitates their integration into modern energy infrastructure. In addition, this solution promotes the implementation of IEC 61850-compliant technologies, ensuring interoperability and standardization between automation systems. The paper presents a detailed evaluation of the reliability and performance characteristics of the proposed centralized relay protection and automation system, which is designed to perform all the main protection functions of medium-voltage switchgear, including line and busbar protection. In addition, the paper describes the architecture of the control system, characterizes its main components, and evaluates the performance of the central controller. It is shown that the computational requirements of such a controller for a typical medium-voltage distribution substation remain within the performance range of modern SCADA-compatible controllers supplied by leading manufacturers of automation in the electric power sector. The results emphasize the feasibility of moving to centralized protection architectures without compromising the functional integrity or responsiveness of the system.
- 9 July 2025
- Published by National Technical University Kharkiv Polytechnic Institute in Bulletin of the National Technical University "KhPI". Series: Energy: Reliability and Energy Efficiency
- No. 1(10),p. 40-46
Open AccessMethod of implementing digitisation of relay protection and automation for power distribution facilities with a voltage of 6-10 kV
The paper presents a new concept for designing a centralized multi-channel control system for medium-voltage switchgear, the main innovation of which is the integration of primary and backup relay protection algorithms into the substation's computing infrastructure, namely, into a backup or redundant server unit known as the Front-End Controller. This architecture is aimed at improving the cost-effectiveness and practical operation of relay protection and automation solutions for energy companies and grid operators. The proposed approach is particularly applicable to the most common types of medium-voltage distribution networks, as well as to power supply systems at industrial enterprises. By moving the protection logic from distributed hardware relays to a central computing node, the system provides a more flexible implementation of modern adaptive relay protection and automation algorithms, which facilitates their integration into modern energy infrastructure. In addition, this solution promotes the implementation of IEC 61850-compliant technologies, ensuring interoperability and standardization between automation systems. The paper presents a detailed evaluation of the reliability and performance characteristics of the proposed centralized relay protection and automation system, which is designed to perform all the main protection functions of medium-voltage switchgear, including line and busbar protection. In addition, the paper describes the architecture of the control system, characterizes its main components, and evaluates the performance of the central controller. It is shown that the computational requirements of such a controller for a typical medium-voltage distribution substation remain within the performance range of modern SCADA-compatible controllers supplied by leading manufacturers of automation in the electric power sector. The results emphasize the feasibility of moving to centralized protection architectures without compromising the functional integrity or responsiveness of the system.
- Open Access
- 9 July 2023
- Published by National Technical University Kharkiv Polytechnic Institute in Bulletin of the National Technical University "KhPI". Series: Energy: Reliability and Energy Efficiency
- No. 1 (6),p. 113-118
ANALYSIS OF DIFFERENTIAL RELAY PROTECTION ALGORITHMS AND THEIR MODELLING IN MATLAB
The paper is devoted to identifying the prospects for software implementation of differential relay protection. The purpose of this study was to analyse the algorithms of the devices' operation, which allowed to create a mathematical model in the MATLAB software environment with the prospect of integration in the form of a single regional relay protection server into the unified energy system of Ukraine. It has been established that virtual models have both advantages and disadvantages compared to digital-analog devices. Their positive feature is that, due to the block principle of construction, it is possible to easily change not only the parameters but also the configuration of the primary network. The disadvantage is that the configuration of virtual protections differs from the configuration of their prototypes - real relays and terminals. The article evaluates the existing, widely used methodology and considers the actual algorithms of two-stage differential relay protection. It is established that differential protection has two stages: 1 - fast-acting differential current cut-off; 2 - sensitive differential current protection with inhibition from through current and recovery from magnetisation current surges. A simplified diagram of a fragment of the electrical system and differential relay protection of a transformer are developed and presented in MATLAB. The algorithms are considered in detail, and it is established that with their help and with the help of the considered principles of differential protection in the Simulink package, the logic of the model is implemented similarly to the logic of microprocessor-based transformer protection "RS-83DT2" of RZA Systems LLC, SPAD 346 C of ABB. Based on the modelling results, the oscillograms of primary currents of normal mode and emergency modes with external and internal short circuits are obtained. The conclusions establish the prospects of using this model and algorithms for the development of a software solution for the relay protection server and for future integration into the integrated power system.
- 9 July 2023
- Published by National Technical University Kharkiv Polytechnic Institute in Bulletin of the National Technical University "KhPI". Series: Energy: Reliability and Energy Efficiency
- No. 1 (6),p. 113-118
Open AccessANALYSIS OF DIFFERENTIAL RELAY PROTECTION ALGORITHMS AND THEIR MODELLING IN MATLAB
The paper is devoted to identifying the prospects for software implementation of differential relay protection. The purpose of this study was to analyse the algorithms of the devices' operation, which allowed to create a mathematical model in the MATLAB software environment with the prospect of integration in the form of a single regional relay protection server into the unified energy system of Ukraine. It has been established that virtual models have both advantages and disadvantages compared to digital-analog devices. Their positive feature is that, due to the block principle of construction, it is possible to easily change not only the parameters but also the configuration of the primary network. The disadvantage is that the configuration of virtual protections differs from the configuration of their prototypes - real relays and terminals. The article evaluates the existing, widely used methodology and considers the actual algorithms of two-stage differential relay protection. It is established that differential protection has two stages: 1 - fast-acting differential current cut-off; 2 - sensitive differential current protection with inhibition from through current and recovery from magnetisation current surges. A simplified diagram of a fragment of the electrical system and differential relay protection of a transformer are developed and presented in MATLAB. The algorithms are considered in detail, and it is established that with their help and with the help of the considered principles of differential protection in the Simulink package, the logic of the model is implemented similarly to the logic of microprocessor-based transformer protection "RS-83DT2" of RZA Systems LLC, SPAD 346 C of ABB. Based on the modelling results, the oscillograms of primary currents of normal mode and emergency modes with external and internal short circuits are obtained. The conclusions establish the prospects of using this model and algorithms for the development of a software solution for the relay protection server and for future integration into the integrated power system.
- Open Access
- 2 July 2022
- Published by National Technical University Kharkiv Polytechnic Institute in Bulletin of the National Technical University "KhPI". Series: Energy: Reliability and Energy Efficiency
- No. 1 (4),p. 79-85
Simulation of the electric field of a polymer bushing in the Ansys Maxwell software environment
The article analyses the software tools for modelling the maps of the electric field strength of insulators. The need to address this issue is dictated by the fact that the uneven electric field on the insulators increases the probability of partial discharges that destroy the insulating layer, so it is very important to optimize the electric field strength on the insulator. The design features of bushings and features of partial discharges in them are considered. The distribution of electric field strength in a polymer pass-through operating in an AC network without contaminants is considered. The results of modelling the electric field of insulators in the software environment Ansys Maxwell, which is based on the simulation of the finite element method, are presented. Points in the construction of a 35 kV bushing polymer insulator have been identified, where the highest level of electric field strength is concentrated. A method of influencing the area under study in the area of the flange connection to the ground plate is proposed. This defines the use of a conductive cover placed between the flange and the place of connection to the polymeric insulating layer, which significantly improves the overall electric field strength distribution on the surface of the bushing polymer insulator and makes it competitive compared to the most commonly used porcelain bushings, by increasing the electrical strength of the structure. According to the results of research, a means of optimizing the electric field of the pass-through polymer insulator is proposed, which allows to increase its electric resistance and reduce the electric field strength in the area of flange contact with the mounting surface, which in turn prevents premature partial discharges in the insulating bodies.
- 2 July 2022
- Published by National Technical University Kharkiv Polytechnic Institute in Bulletin of the National Technical University "KhPI". Series: Energy: Reliability and Energy Efficiency
- No. 1 (4),p. 79-85
Open AccessSimulation of the electric field of a polymer bushing in the Ansys Maxwell software environment
The article analyses the software tools for modelling the maps of the electric field strength of insulators. The need to address this issue is dictated by the fact that the uneven electric field on the insulators increases the probability of partial discharges that destroy the insulating layer, so it is very important to optimize the electric field strength on the insulator. The design features of bushings and features of partial discharges in them are considered. The distribution of electric field strength in a polymer pass-through operating in an AC network without contaminants is considered. The results of modelling the electric field of insulators in the software environment Ansys Maxwell, which is based on the simulation of the finite element method, are presented. Points in the construction of a 35 kV bushing polymer insulator have been identified, where the highest level of electric field strength is concentrated. A method of influencing the area under study in the area of the flange connection to the ground plate is proposed. This defines the use of a conductive cover placed between the flange and the place of connection to the polymeric insulating layer, which significantly improves the overall electric field strength distribution on the surface of the bushing polymer insulator and makes it competitive compared to the most commonly used porcelain bushings, by increasing the electrical strength of the structure. According to the results of research, a means of optimizing the electric field of the pass-through polymer insulator is proposed, which allows to increase its electric resistance and reduce the electric field strength in the area of flange contact with the mounting surface, which in turn prevents premature partial discharges in the insulating bodies.