RPRafal Pajak

Rafal Pajak

*This is an algorithmically generated author record based on publicly available information.

Rafal Pajak has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Frequency–Temperature Characteristics of the Cellulose—Insulating Oil–Water Nanodroplet Nanocomposite Components for Diagnostic Evaluation of Power Transformer Insulation

    by Pawel Zukowski, Konrad Kierczynski, Przemyslaw Rogalski, Pawel Okal, Pawel Molenda, Marek Szrot, Rafal Pajak

    We determined the reference characteristics of the loss tangent and the real component of the complex permittivity of the cellulose-insulating oil–water nanodroplet nanocomposite with a moisture content of 5.17% by weight in pressboard. Such a high moisture content was selected because a value close to 5% by weight is critical, and reaching it may lead to catastrophic transformer failure as well as contamination of the natural environment with poorly biodegradable mineral oil and products of its incomplete combustion. Based on the measurement results, the values of the loss tangent and the real and imaginary components of the complex permittivity of the power transformer insulation system, consisting of moistened pressboard and insulating oil, were determined according to CIGRE. These values were obtained for both factory-new and moistened mineral oil. It was found that oil moisture content has a significant impact on the tanδ characteristics of strongly moistened liquid–solid insulation in the lowest frequency range. In the intermediate frequency range, this effect gradually decreases and then practically disappears. In the frequency range above 50 Hz, the tanδ values depend on the moisture content in cellulose and on the geometrical parameters of the insulation components in the CIGRE system, and do not depend on the oil moisture content. The influence of oil moisture on the estimation of cellulose moisture content becomes noticeable starting from a water content of 2% in pressboard. This should be taken into account in insulation condition analysis and in moisture level estimation in order to detect a critical state threatening catastrophic failure of a power transformer. It was also determined that the real component of the complex permittivity depends only weakly on oil moisture, and only in the low-temperature and low-frequency ranges. In contrast, the imaginary component of the complex permittivity depends on oil moisture practically in the same way as the loss tangent of the power transformer insulation system.


  • Open Access

    Study of AC Conductivity and Relaxation Times Depending on Moisture Content in Nanocomposites of Insulation Pressboard–Innovative Bio-Oil–Water Nanodroplets

    by Pawel Zukowski, Konrad Kierczynski, Pawel Okal, Marek Zenker, Rafal Pajak, Marek Szrot, Pawel Molenda, Tomasz N. Koltunowicz

    The aim of this study was to determine the frequency–temperature dependence of the AC conductivity and relaxation times in humid electrical pressboard used in the insulation of power transformers, impregnated with the innovative NYTRO® BIO 300X bio-oil produced from plant raw materials. Tests were carried out for a composite of cellulose–bio-oil–water nanodroplets with a moisture content of 0.6% by weight to 5% by weight in the frequency range from 10−4 Hz to 5·103 Hz. The measurement temperatures ranged from 20 °C to 70 °C. The current conductivity in percolation channels in cellulose–bio insulating oil–water nanodroplets nanocomposites was analyzed. In such nanocomposites, DC conduction takes place via electron tunneling between the potential wells formed by the water nanodroplets. It was found that the value of the percolation channel resistance is lowest in the case of a regular arrangement of the nanodroplets. As disorder increases, characterized by an increase in the standard deviation value, the percolation channel resistance increases. It was found that the experimental values of the activation energy of the conductivity and the relaxation time of the composite of cellulose–bio-oil–water nanodroplets are the same within the limits of uncertainty and do not depend on the moisture content. The value of the generalized activation energy is ΔE ≈ (1.026 ± 0.0160) eV and is constant over the frequency and temperature ranges investigated. This study shows that in the lowest frequency region, the conductivity value does not depend on frequency. As the frequency increases further, the relaxation time decreases; so, the effect of moisture on the conductivity value decreases. The dependence of the DC conductivity on the moisture content was determined. For low moisture contents, the DC conductivity is practically constant. With a further increase in water content, there is a sharp increase in DC conductivity. Such curves are characteristic of the dependence of the DC conductivity of composites and nanocomposites on the content of the conducting phase. A percolation threshold value of xc ≈ (1.4 ± 0.3)% by weight was determined from the intersection of flat and steeply sloping sections. The frequency dependence of the values of the relative relaxation times was determined for composites with moisture contents from 0.6% by weight to 5% by weight for a measurement temperature of 60 °C. The highest relative values of the relaxation time τref occur for direct current and for the lowest frequencies close to 10−4 Hz. As the frequency increases further, the relaxation time decreases. The derivatives d(logτref)/d(logf) were calculated, from the analysis of which it was determined that there are three stages of relaxation time decrease in the nanocomposites studied. The first occurs in the frequency region from 10−4 Hz to about 3·10−1 Hz, and the second from about 3·10−1 Hz to about 1.5·101 Hz. The beginning of the third stage is at a frequency of about 1.5·101 Hz. The end of this stage is above the upper range of the Frequency Domain Spectroscopy (FDS) meter, which is 5·103 Hz. It has been established that the nanodroplets are in the cellulose and not in the bio-oil. The occurrence of three stages on the frequency dependence of the relaxation time can be explained when the fibrous structure of the cellulose is taken into account. Nanodroplets, found in micelles, microfibrils and in the fibers of which cellulose is composed, can have varying distances between nanodroplets, determined by the dimensions of these cellulose components.


  • Open Access

    Research on the Influence of Moisture in the Solid Insulation Impregnated with an Innovative Bio-Oil on AC Conductivity Used in the Power Transformers

    by Pawel Zukowski, Konrad Kierczynski, Przemyslaw Rogalski, Pawel Okal, Marek Zenker, Rafal Pajak, Marek Szrot, Pawel Molenda, Tomasz N. Koltunowicz

    The study determines the frequency–temperature dependence of the conductivity of a moist solid insulation component of power transformers, impregnated with the innovative bio-oil NYTRO® BIO 300X, manufactured from plant-based raw materials. The research was conducted for six moisture levels ranging from 0.6% to 5% by weight, within a frequency range from 10−4 Hz to 5 · 103 Hz and measurement temperatures from 20 °C to 70 °C, with a 10 °C step. The conduction model for both DC and AC, based on the quantum mechanical phenomenon of electron tunneling between water nanodroplets, was used to analyze the obtained results. It was determined that the frequency dependence of the conductivity of pressboard-bio-oil-moisture composites is influenced by two factors as follows: the activation energy of conductivity and the activation energy of relaxation time. For each moisture content, 16 values of the activation energy of the relaxation time and 16 values of the activation energy of conductivity were determined. It was found that the values of activation energy of conductivity and relaxation time are equal and independent of moisture content, frequency, and temperature. Based on 192 residual activation energy values, the mean generalized activation energy value for the relaxation time and conductivity was calculated with high precision, resulting in ΔE ≈ (1.02627 ± 0.01606) eV. The uncertainty of its determination was only ±1.6%. This indicates that electron tunneling from the first nanodroplet to the second, causing AC conductivity, and their return from the second nanodroplet to the first, determining the relaxation time, occur between the same energy states belonging to the water nanodroplets located in the pressboard impregnated with bio-oil. For each moisture content, the curves obtained for different measurement temperatures were recalculated to a reference temperature of 20 °C using the generalized activation energy. It was found that the shifted curves obtained for different temperatures perfectly overlap. Increased moisture content shifts the recalculated curves toward higher conductivity values. It was established that for all moisture contents in the lowest frequency range, conductivity is constant (DC conductivity). A further increase in frequency causes a rapid rise in conductivity. The increasing period can be divided into two stages. The first stage occurs up to about 100 Hz–101 Hz, depending on the moisture content. In the second stage, the rate of conductivity increase is higher, and its value depends on moisture content. The lower the moisture content, the faster the conductivity increases. Recalculation using the generalized activation energy eliminated the effect of temperature on the curves. It was found that the shapes of the recalculated curves and their position relative to the coordinates depend only on the moisture content in the composite. The equality of the activation energy of the relaxation time and conductivity established in the study, as well as their independence from frequency and moisture content in the pressboard impregnated with NYTRO® BIO 300X bio-oil, allows for recalculating the curves of electrical parameters determined at any operating temperatures of the transformer to a reference temperature, for example, 20 °C. Comparing the curve obtained for the transformer, recalculated to the reference temperature, with reference curves determined by us in the laboratory for different moisture contents, will allow for the precise determination of the moisture content of the solid insulation component impregnated with NYTRO® BIO 300X bio-oil. This will contribute to the early detection of approaching critical moisture content, threatening catastrophic transformer failure.


  • Open Access

    Analysis of the Influence of Insulation Moisture during Long-Term Exploitation of Transformers on Their Reliability as Determined by Alternating Current Electrical Parameters

    by Pawel Zukowski, Konrad Kierczynski, Przemyslaw Rogalski, Vitalii Bondariev, Marek Zenker, Rafal Pajak, Marek Szrot, Pawel Molenda, Tomasz N. Koltunowicz

    This paper presents the results of the study of the direct current (DC) and alternating current (AC) electrical properties of an electrical pressboard–bio-insulating oil–water composite in a wide range of water content and temperatures used in electric power transformers. These parameters allow the level of insulation reliability to be determined after many years of operation of power transformers. To analyse the experimental results, a model of the DC and AC conductivities of nanocomposites based on the quantum-mechanical phenomenon of electron tunnelling was used. It was found that in a low-frequency region, the conductivities of AC and DC and their activation energy are equal. The relaxation times of AC conductivity and permittivity are also equal. It was found that the dependence of the DC conductivity on the distance between water molecules is an exponential function. On the basis of the model of conductivity by electron tunnelling between potential wells, the average number of water molecules in a nanodroplet, located in a composite of electrical pressboard–bio-insulating oil–moisture was determined to be (126 ± 20). It was found that the measured dependencies of DC and AC conductivity, permeability and dielectric relaxation times are consistent with the results of computer simulations performed on the basis of the model. This study showed that the composite of pressboard impregnated with bio-oil spontaneously transforms through water absorption into a pressboard–bio-oil–water nanocomposite. These will serve as the basis for the application of actual conductivity and dielectric relaxation mechanisms to improve the accuracy of moisture estimation in the solid component of power transformer insulation carried out on the basis of measurements of DC and AC properties. This will improve the operational safety of the transformers, minimise the occurrence of transformer failure and the associated environmental pollution.

  • Open Access

    Research on Changes in the Phase Shift Angle and Admittance of the Cellulose–Bio-Oil Composite under the Influence of Increasing Moisture during the Long-Term Operation of Power Transformers

    by Pawel Zukowski, Konrad Kierczynski, Paweł Okal, Przemyslaw Rogalski, Marek Zenker, Rafal Pajak, Pawel Molenda, Marek Szrot, Tomasz N. Koltunowicz

    In this study, the temperature–frequency dependencies of the pressboard–bio-oil–water nanoparticle composite’s fundamental parameters—phase shift angle and admittance—were examined using the Frequency Domain Spectroscopy method. Measurements were conducted in a frequency range of 10−4 Hz to 5 × 103 Hz at temperatures ranging from 293.15 K to 343.15 K, with a step of 10 K. The temperature stabilization accuracy was less than ±0.05 K. A total of 15 Arrhenius plots were determined for various phase shift angle values, from which 15 values and the average activation energy of relaxation time were determined. Similarly, the values of the activation energy of admittance relaxation time and the activation energy of admittance were determined. It was established that all three average values are identical within the bounds of uncertainty. Based on 45 values, a generalized activation energy was determined, with a value of ΔW ≈ (1.032 ± 0.0196) eV. Using the generalized activation energy value, the phase shift angle curves determined for all temperatures were recalculated to a temperature of 293.15 K. It was found that after conversion, all curves perfectly overlap. A similar operation was carried out for the frequency dependencies of admittance. In this case, too, the recalculated dependencies perfectly match. This means that the shape of the frequency dependencies of the phase shift angle and admittance depends solely on the moisture content in the pressboard–bio-oil–water nanodrop composite. The position of the curves in doubly logarithmic coordinates depends only on temperature and is determined by the generalized activation energy Using the generalized activation energy determined in this study will allow for the development of accurate methods for estimating moisture content in cellulose insulation of power transformers containing bio-oil. This will contribute to the detection of critical moisture content, which is about 5% by weight, and to the elimination of the risk, associated with such a high moisture content, of catastrophic failure of power transformers.