Ruilin Zhong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ruilin Zhong has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Jian Wang
Mass Laboratory, National Institute of Metrology, Beijing, China
3 shared publications Changqing Cai
National Institute of Metrology, Beijing, China
1 shared publication- Changqing Cai
Division of Mechanics and Acoustics, National Institute of Metrology, Beijing 100029, China
1 shared publication - Cheng Peng
Mass Laboratory, National Institute of Metrology, Beijing, China
1 shared publication - Di Wu
School of Electrical and Computer Engineering, University of Oklahoma, 110 West Boyd Street, Norman, OK 73019, United States of America
1 shared publication Hanghang Chen
National Institute of Metrology, Beijing, China
1 shared publication
Latest Publications
- 6 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-8
Comparison of Mass Measurement Between Joule Balance and Primary Mass Standard
Conducting a stability check for joule balance after kilogram redefinition is crucial. This study investigates the mass measurement difference between joule balance and primary mass standard. Measurement results obtained in three different ways were compared and analyzed: the joule balance in vacuum, the primary working mass standard in China with M_one in vacuum, and the primary working mass standard in China with M_one in air. The experiments demonstrated that the mass measurement results based on the joule balance and primary mass standards are consistent with each other within the relative standard uncertainty of 4×10-8.
- 6 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-8
Comparison of Mass Measurement Between Joule Balance and Primary Mass Standard
Conducting a stability check for joule balance after kilogram redefinition is crucial. This study investigates the mass measurement difference between joule balance and primary mass standard. Measurement results obtained in three different ways were compared and analyzed: the joule balance in vacuum, the primary working mass standard in China with M_one in vacuum, and the primary working mass standard in China with M_one in air. The experiments demonstrated that the mass measurement results based on the joule balance and primary mass standards are consistent with each other within the relative standard uncertainty of 4×10-8.
- 1 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-6
A Novel Method for Precise Center of Mass Height Measurement of Artifacts
Center of mass (CM) height is a critical mass property of an artefact. It is needed in the aerospace industry, conventional vehicle manufacturing, and measurements of the gravitational constant, G. Despite many experiments and research efforts, a standard or a traceable method to determine CM height remains undefined in precise measurements. This paper described a new method to measure CM height using a bi-weighing bridge measuring system, which can effectively eliminate the measurement error that exists in the joint between the weighbridge and the artefacts. Tests on the weight were carried out by this method, and we obtained CM height of the test weight to be 34.56 mm, with a combined standard uncertainty of 0.08 mm. This is a relatively small uncertainty for measuring artefacts with mass in 1 kg, among previous studies reported until now. Compared to a conventional method, CM height estimated by the new method is verified to be much closer to the theoretical value.
- 1 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-6
A Novel Method for Precise Center of Mass Height Measurement of Artifacts
Center of mass (CM) height is a critical mass property of an artefact. It is needed in the aerospace industry, conventional vehicle manufacturing, and measurements of the gravitational constant, G. Despite many experiments and research efforts, a standard or a traceable method to determine CM height remains undefined in precise measurements. This paper described a new method to measure CM height using a bi-weighing bridge measuring system, which can effectively eliminate the measurement error that exists in the joint between the weighbridge and the artefacts. Tests on the weight were carried out by this method, and we obtained CM height of the test weight to be 34.56 mm, with a combined standard uncertainty of 0.08 mm. This is a relatively small uncertainty for measuring artefacts with mass in 1 kg, among previous studies reported until now. Compared to a conventional method, CM height estimated by the new method is verified to be much closer to the theoretical value.
- Open Access
- 1 March 2021
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1838 (1) , 012072
Research on the Device of Measuring the Centre of a Weight
In order to correct the influence on precision mass measurement caused by the difference between centres of the test weight and the reference weight, the centre of the weight need to be measured, and a device is developed to locate the centre of the weight which includes a balance, a bridge and a supporting pole. In this paper, the detailed force analysis of this device is studied, and the detailed information on designing and selecting each part of the device is given.
- 1 March 2021
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1838 (1) , 012072
Open AccessResearch on the Device of Measuring the Centre of a Weight
In order to correct the influence on precision mass measurement caused by the difference between centres of the test weight and the reference weight, the centre of the weight need to be measured, and a device is developed to locate the centre of the weight which includes a balance, a bridge and a supporting pole. In this paper, the detailed force analysis of this device is studied, and the detailed information on designing and selecting each part of the device is given.
- Open Access
- 1 February 2021
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1815 (1) , 012011
Research on the Computer Controlled Velocity Simulation Device for Continuous Totalizing Automatic Weighing Instruments
Continuous totalizing automatic weighing instruments is widely used in many industries, and need to be tested under different conditions especially for different temperature, humidity and electrical disturbance. Usually this kind of weighing instruments are very large and can not be put into such test environments, thus a test sample without belt conveyor is needed. Due to the working principle of continuous totalizing automatic weighing instruments, the test sample may include not only essential part of weighing instruments such as load cell, indicator, and load receptor, but also a device to simulate the displacement of the belt. In the paper, a device that can simulate the velocity of the belt is researched, it can generate square pulse signals to the test sample, thus the sample can operate as normal belt weigher. The configuration of the device is discussed and example is given to show its effectiveness.
- 1 February 2021
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1815 (1) , 012011
Open AccessResearch on the Computer Controlled Velocity Simulation Device for Continuous Totalizing Automatic Weighing Instruments
Continuous totalizing automatic weighing instruments is widely used in many industries, and need to be tested under different conditions especially for different temperature, humidity and electrical disturbance. Usually this kind of weighing instruments are very large and can not be put into such test environments, thus a test sample without belt conveyor is needed. Due to the working principle of continuous totalizing automatic weighing instruments, the test sample may include not only essential part of weighing instruments such as load cell, indicator, and load receptor, but also a device to simulate the displacement of the belt. In the paper, a device that can simulate the velocity of the belt is researched, it can generate square pulse signals to the test sample, thus the sample can operate as normal belt weigher. The configuration of the device is discussed and example is given to show its effectiveness.
- Open Access
- 1 August 2018
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1065 (4) , 042052
Investigation of two methods of volume measurements based on hydrostatic comparison method
Volume of weights is needed for air buoyancy correction, and measurement methods based on hydrostatic comparison are widely used to detect volume of weights. Several different hydrostatic comparison methods are given in OIML R111. In NIM, two different devices had already been set up to measure the volume of weights, and one is based on a mechanical balance, and another is based on an electrical balance. In this paper, two methods are discussed. Detailed measurement procedure and calculation are investigated, and uncertainty evaluation are also given. The consistence of two methods is also discussed based on an example.
- 1 August 2018
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1065 (4) , 042052
Open AccessInvestigation of two methods of volume measurements based on hydrostatic comparison method
Volume of weights is needed for air buoyancy correction, and measurement methods based on hydrostatic comparison are widely used to detect volume of weights. Several different hydrostatic comparison methods are given in OIML R111. In NIM, two different devices had already been set up to measure the volume of weights, and one is based on a mechanical balance, and another is based on an electrical balance. In this paper, two methods are discussed. Detailed measurement procedure and calculation are investigated, and uncertainty evaluation are also given. The consistence of two methods is also discussed based on an example.
- Open Access
- 1 January 2013
- Published by World Scientific Pub Co Pte Ltd in International Journal of Modern Physics: Conference Series
- Vol. 24
RESEARCH ON VOLUME MEASUREMENT SYSTEM OF WEIGHTS WITH HYDROSTATIC TECHNIQUE
According to Annex B.7.4 of OIML R111-1, equipment for measuring volume of weights mass ranging from 1 kg to 20 kg including three methods of hydrostatic comparison is described. The equipment consists of a robot arm for transferring weights, a liquid bath, a mass comparator with 26.1 kg of maximum capacity and 1 mg of readability, glass housing, two weight exchangers including in air and in liquid, two weight holders including in air and in liquid, and a controller. The equipment will enable to perform automatically volume measurements.
- 1 January 2013
- Published by World Scientific Pub Co Pte Ltd in International Journal of Modern Physics: Conference Series
- Vol. 24
Open AccessRESEARCH ON VOLUME MEASUREMENT SYSTEM OF WEIGHTS WITH HYDROSTATIC TECHNIQUE
According to Annex B.7.4 of OIML R111-1, equipment for measuring volume of weights mass ranging from 1 kg to 20 kg including three methods of hydrostatic comparison is described. The equipment consists of a robot arm for transferring weights, a liquid bath, a mass comparator with 26.1 kg of maximum capacity and 1 mg of readability, glass housing, two weight exchangers including in air and in liquid, two weight holders including in air and in liquid, and a controller. The equipment will enable to perform automatically volume measurements.