FLFrancesca Leek

Francesca Leek

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Francesca Leek has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Optimisation of the air fraction correction for lung PET/CT: addressing resolution mismatch

    by Francesca Leek, Cameron Anderson, Andrew P. Robinson, Robert M. Moss, Joanna C. Porter, Helen S. Garthwaite, Ashley M. Groves, Brian F. Hutton, Kris Thielemans

    Background: Increased pulmonary $$^{18}{}$$18 F-FDG metabolism in patients with idiopathic pulmonary fibrosis, and other forms of diffuse parenchymal lung disease, can predict measurements of health and lung physiology. To improve PET quantification, voxel-wise air fractions (AF) determined from CT can be used to correct for variable air content in lung PET/CT. However, resolution mismatches between PET and CT can cause artefacts in the AF-corrected image.Methods: Three methodologies for determining the optimal kernel to smooth the CT are compared with noiseless simulations and non-TOF MLEM reconstructions of a patient-realistic digital phantom: (i) the point source insertion-and-subtraction method, $$h_{pts}$$hpts ; (ii) AF-correcting with varyingly smoothed CT to achieve the lowest RMSE with respect to the ground truth (GT) AF-corrected volume of interest (VOI), $$h_{AFC}$$hAFC ; iii) smoothing the GT image to match the reconstruction within the VOI, $$h_{PVC}$$hPVC . The methods were evaluated both using VOI-specific kernels, and a single global kernel optimised for the six VOIs combined. Furthermore, $$h_{PVC}$$hPVC was implemented on thorax phantom data measured on two clinical PET/CT scanners with various reconstruction protocols.Results: The simulations demonstrated that at $$<200$$<200 iterations (200 i), the kernel width was dependent on iteration number and VOI position in the lung. The $$h_{pts}$$hpts method estimated a lower, more uniform, kernel width in all parts of the lung investigated. However, all three methods resulted in approximately equivalent AF-corrected VOI RMSEs (<10%) at $$\ge$$≥ 200i. The insensitivity of AF-corrected quantification to kernel width suggests that a single global kernel could be used. For all three methodologies, the computed global kernel resulted in an AF-corrected lung RMSE <10% at $$\ge$$≥ 200i, while larger lung RMSEs were observed for the VOI–specific kernels. The global kernel approach was then employed with the $$h_{PVC}$$hPVC method on measured data. The optimally smoothed GT emission matched the reconstructed image well, both within the VOI and the lung background. VOI RMSE was <10%, pre-AFC, for all reconstructions investigated.Conclusions: Simulations for non-TOF PET indicated that around 200i were needed to approach image resolution stability in the lung. In addition, at this iteration number, a single global kernel, determined from several VOIs, for AFC, performed well over the whole lung. The $$h_{PVC}$$hPVC method has the potential to be used to determine the kernel for AFC from scans of phantoms on clinical scanners.


  • Open Access

    A Demonstration of STIR-GATE-Connection

    by Robert Twyman, Ludovica Brusaferri, Elise C. Emond, Francesca Leek, Simon Arridge, Brian F. Hutton, Vesna Cuplov, Kris Thielemans

    We present the first open-source version of STIR-GATE-Connection, a project that aims to provide an easy-to-use pipeline to simulate realistic PET data using GATE, followed by quantitative reconstruction using STIR. Monte Carlo simulations and image reconstruction are powerful research tools for emission tomography that can assist with the design of new medical imaging devices as well as the evaluation of novel image reconstruction algorithms and various correction techniques. STIR-GATE-Connection is a collection of scripts that aid with the: (i) setup of a realistic GATE simulation of a voxelised phantom using a user selected scanner configuration, (ii) conversion of the output list mode data into STIR compatible sinograms, and (iii) computation of additive and multiplicative data corrections for Poisson image reconstruction using STIR. In this work, we demonstrate example usage of these steps. A public release of STIR-GATE-Connection, licensed under the Apache 2.0 License, can be downloaded at: http://www.github.com/UCL/STIR-GATE-Connection.