Edward Jay Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Interests
Edward Jay Wang has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
- Jessica de Souza
Electrical and Computer Engineering, University of California San Diego, La Jolla, California, USA and The Design Lab, University of California San Diego, La Jolla, California, USA
5 shared publications - Ava Jean Fascetti
University of California San Diego
3 shared publications - Colin Barry
University of California San Diego, La Jolla, California, USA
3 shared publications - Kristina Chamberlain
Univ Calif San Diego, Div Extended Studies, La Jolla, CA USA
3 shared publications - Varun Kumar Viswanath
Department of Electrical and Computer Engineering, Jacobs School of Engineering, University of California, San Diego, USA
3 shared publications - Ariana Talai
The Design Lab, University of California San Diego, La Jolla, California, USA
2 shared publications
Latest Publications
- 20 April 2026
- Published by Springer Nature in Nature Health
- Vol. 1 (8) , 840-849
A multi-agent framework combining large language models with medical flowcharts for self-triage
- 20 April 2026
- Published by Springer Nature in Nature Health
- Vol. 1 (8) , 840-849
A multi-agent framework combining large language models with medical flowcharts for self-triage
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Engineering in Medicine and Biology
- Vol. 7, 308-315
Physiologically Interpretable Photoplethysmography Features Associated With Peripheral Artery Disease
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Engineering in Medicine and Biology
- Vol. 7, 308-315
Open AccessPhysiologically Interpretable Photoplethysmography Features Associated With Peripheral Artery Disease
- Open Access
- 12 October 2025
- Published by Association for Computing Machinery (ACM)
- p. 377-381
Far Red Postables: Ultra-low-cost Pupillometry
- 12 October 2025
- Published by Association for Computing Machinery (ACM)
- p. 377-381
Open AccessFar Red Postables: Ultra-low-cost Pupillometry
- Open Access
- 7 July 2025
- Published by Association for Computing Machinery (ACM)
- p. 1-17
Understanding the Challenges and Design Opportunities of Using Voice Assistants to Support Postpartum Mothers in Brazil
- 7 July 2025
- Published by Association for Computing Machinery (ACM)
- p. 1-17
Open AccessUnderstanding the Challenges and Design Opportunities of Using Voice Assistants to Support Postpartum Mothers in Brazil
- Top Cited PapersOpen Access
- 28 March 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (13) , eadq0305
Demographic bias of expert-level vision-language foundation models in medical imaging
Advances in artificial intelligence (AI) have achieved expert-level performance in medical imaging applications. Notably, self-supervised vision-language foundation models can detect a broad spectrum of pathologies without relying on explicit training annotations. However, it is crucial to ensure that these AI models do not mirror or amplify human biases, disadvantaging historically marginalized groups such as females or Black patients. In this study, we investigate the algorithmic fairness of state-of-the-art vision-language foundation models in chest x-ray diagnosis across five globally sourced datasets. Our findings reveal that compared to board-certified radiologists, these foundation models consistently underdiagnose marginalized groups, with even higher rates seen in intersectional subgroups such as Black female patients. Such biases present over a wide range of pathologies and demographic attributes. Further analysis of the model embedding uncovers its substantial encoding of demographic information. Deploying medical AI systems with biases can intensify preexisting care disparities, posing potential challenges to equitable healthcare access and raising ethical questions about their clinical applications.
- 28 March 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (13) , eadq0305
Top Cited PapersOpen AccessDemographic bias of expert-level vision-language foundation models in medical imaging
Advances in artificial intelligence (AI) have achieved expert-level performance in medical imaging applications. Notably, self-supervised vision-language foundation models can detect a broad spectrum of pathologies without relying on explicit training annotations. However, it is crucial to ensure that these AI models do not mirror or amplify human biases, disadvantaging historically marginalized groups such as females or Black patients. In this study, we investigate the algorithmic fairness of state-of-the-art vision-language foundation models in chest x-ray diagnosis across five globally sourced datasets. Our findings reveal that compared to board-certified radiologists, these foundation models consistently underdiagnose marginalized groups, with even higher rates seen in intersectional subgroups such as Black female patients. Such biases present over a wide range of pathologies and demographic attributes. Further analysis of the model embedding uncovers its substantial encoding of demographic information. Deploying medical AI systems with biases can intensify preexisting care disparities, posing potential challenges to equitable healthcare access and raising ethical questions about their clinical applications.
- Open Access
- 5 October 2024
- Published by Association for Computing Machinery (ACM)
- p. 147-151
Development of a One Dollar Blood Pressure Monitor
BPClip is an ultra-low-cost cuffless blood pressure monitor. As a universal smartphone attachment, BPClip leverages the computational imaging power of smartphones to perform oscillometry based blood pressure measurements. This paper examines different design considerations in BPClip's development. The cost and accuracy of blood pressure measurements are the central design goals. Both requirements are achieved with the initial prototype that achieves a 0.80 USD material cost and a mean absolute error of 8.72 and 5.49 mmHg for systolic and diastolic blood pressure, respectively. Since a main motivator to develop BPClip is making blood pressure monitoring more accessible, usability is also central to the design. User studies were conducted throughout the design process to inform the most intuitive and accessible design features. In this paper, we demystify the design process to share effective design practices with future developers working towards expanding health monitoring access beyond traditional clinical settings.
- 5 October 2024
- Published by Association for Computing Machinery (ACM)
- p. 147-151
Open AccessDevelopment of a One Dollar Blood Pressure Monitor
BPClip is an ultra-low-cost cuffless blood pressure monitor. As a universal smartphone attachment, BPClip leverages the computational imaging power of smartphones to perform oscillometry based blood pressure measurements. This paper examines different design considerations in BPClip's development. The cost and accuracy of blood pressure measurements are the central design goals. Both requirements are achieved with the initial prototype that achieves a 0.80 USD material cost and a mean absolute error of 8.72 and 5.49 mmHg for systolic and diastolic blood pressure, respectively. Since a main motivator to develop BPClip is making blood pressure monitoring more accessible, usability is also central to the design. User studies were conducted throughout the design process to inform the most intuitive and accessible design features. In this paper, we demystify the design process to share effective design practices with future developers working towards expanding health monitoring access beyond traditional clinical settings.
- Open Access
- 5 October 2024
- Published by Association for Computing Machinery (ACM)
- p. 220-224
VibroBP: An Oscillometric Smartphone Blood Pressure App
This interactivity features a smartphone-based method for measuring blood pressure (BP) using the oscillometric method. To measure BP, it is necessary to measure (1) the pressure applied to the artery and (2) the local blood volume change. This is accomplished by performing an oscillometric measurement at the finger's digital artery, whereby a user presses down on the phone's camera with steadily increasing force. The camera is used to capture the blood volume change using photoplethysmography. We devised a novel method for measuring the force applied by the finger without the use of specialized smartphone hardware with a technique called Vibrometric Force Estimation (VFE). The fundamental concept of VFE relies on a phenomenon where a vibrating object is dampened when an external force is applied on it. This phenomenon can be recreated using the phone's own vibration motor, where the resulting damped vibration is measured using the smartphone's Inertial Measurement Unit (IMU). A cross device reliability study with three smartphones of different manufacturers, shape, and prices results in similar force estimation performance across all smartphone models. In an N=24 validation study of the BP measurement, the smartphone technique achieves a MAE of 8.4 mmHg and 8.5 mmHg of systolic and diastolic BP, respectively, compared to an FDA approved BP cuff. The mean error (bias) and standard deviation are 0.44±10.2 mmHg and 0.03±10.5mmHg for systolic and diastolic, respectively. The vision for this technology is not necessarily to replace existing BP monitoring solutions, but rather to introduce a downloadable smartphone software application that could serve as a low-barrier hypertension screening measurement fit for widespread adoption.
- 5 October 2024
- Published by Association for Computing Machinery (ACM)
- p. 220-224
Open AccessVibroBP: An Oscillometric Smartphone Blood Pressure App
This interactivity features a smartphone-based method for measuring blood pressure (BP) using the oscillometric method. To measure BP, it is necessary to measure (1) the pressure applied to the artery and (2) the local blood volume change. This is accomplished by performing an oscillometric measurement at the finger's digital artery, whereby a user presses down on the phone's camera with steadily increasing force. The camera is used to capture the blood volume change using photoplethysmography. We devised a novel method for measuring the force applied by the finger without the use of specialized smartphone hardware with a technique called Vibrometric Force Estimation (VFE). The fundamental concept of VFE relies on a phenomenon where a vibrating object is dampened when an external force is applied on it. This phenomenon can be recreated using the phone's own vibration motor, where the resulting damped vibration is measured using the smartphone's Inertial Measurement Unit (IMU). A cross device reliability study with three smartphones of different manufacturers, shape, and prices results in similar force estimation performance across all smartphone models. In an N=24 validation study of the BP measurement, the smartphone technique achieves a MAE of 8.4 mmHg and 8.5 mmHg of systolic and diastolic BP, respectively, compared to an FDA approved BP cuff. The mean error (bias) and standard deviation are 0.44±10.2 mmHg and 0.03±10.5mmHg for systolic and diastolic, respectively. The vision for this technology is not necessarily to replace existing BP monitoring solutions, but rather to introduce a downloadable smartphone software application that could serve as a low-barrier hypertension screening measurement fit for widespread adoption.
- Open Access
- 24 June 2024
- Published by JMIR Publications Inc. in JMIR AI
- Vol. 3, e54798
Augmenting Telepostpartum Care With Vision-Based Detection of Breastfeeding-Related Conditions: Algorithm Development and Validation
Background: Breastfeeding benefits both the mother and infant and is a topic of attention in public health. After childbirth, untreated medical conditions or lack of support lead many mothers to discontinue breastfeeding. For instance, nipple damage and mastitis affect 80% and 20% of US mothers, respectively. Lactation consultants (LCs) help mothers with breastfeeding, providing in-person, remote, and hybrid lactation support. LCs guide, encourage, and find ways for mothers to have a better experience breastfeeding. Current telehealth services help mothers seek LCs for breastfeeding support, where images help them identify and address many issues. Due to the disproportional ratio of LCs and mothers in need, these professionals are often overloaded and burned out. Objective: This study aims to investigate the effectiveness of 5 distinct convolutional neural networks in detecting healthy lactating breasts and 6 breastfeeding-related issues by only using red, green, and blue images. Our goal was to assess the applicability of this algorithm as an auxiliary resource for LCs to identify painful breast conditions quickly, better manage their patients through triage, respond promptly to patient needs, and enhance the overall experience and care for breastfeeding mothers. Methods: We evaluated the potential for 5 classification models to detect breastfeeding-related conditions using 1078 breast and nipple images gathered from web-based and physical educational resources. We used the convolutional neural networks Resnet50, Visual Geometry Group model with 16 layers (VGG16), InceptionV3, EfficientNetV2, and DenseNet169 to classify the images across 7 classes: healthy, abscess, mastitis, nipple blebs, dermatosis, engorgement, and nipple damage by improper feeding or misuse of breast pumps. We also evaluated the models’ ability to distinguish between healthy and unhealthy images. We present an analysis of the classification challenges, identifying image traits that may confound the detection model. Results: The best model achieves an average area under the receiver operating characteristic curve of 0.93 for all conditions after data augmentation for multiclass classification. For binary classification, we achieved, with the best model, an average area under the curve of 0.96 for all conditions after data augmentation. Several factors contributed to the misclassification of images, including similar visual features in the conditions that precede other conditions (such as the mastitis spectrum disorder), partially covered breasts or nipples, and images depicting multiple conditions in the same breast. Conclusions: This vision-based automated detection technique offers an opportunity to enhance postpartum care for mothers and can potentially help alleviate the workload of LCs by expediting decision-making processes.
- 24 June 2024
- Published by JMIR Publications Inc. in JMIR AI
- Vol. 3, e54798
Open AccessAugmenting Telepostpartum Care With Vision-Based Detection of Breastfeeding-Related Conditions: Algorithm Development and Validation
Background: Breastfeeding benefits both the mother and infant and is a topic of attention in public health. After childbirth, untreated medical conditions or lack of support lead many mothers to discontinue breastfeeding. For instance, nipple damage and mastitis affect 80% and 20% of US mothers, respectively. Lactation consultants (LCs) help mothers with breastfeeding, providing in-person, remote, and hybrid lactation support. LCs guide, encourage, and find ways for mothers to have a better experience breastfeeding. Current telehealth services help mothers seek LCs for breastfeeding support, where images help them identify and address many issues. Due to the disproportional ratio of LCs and mothers in need, these professionals are often overloaded and burned out. Objective: This study aims to investigate the effectiveness of 5 distinct convolutional neural networks in detecting healthy lactating breasts and 6 breastfeeding-related issues by only using red, green, and blue images. Our goal was to assess the applicability of this algorithm as an auxiliary resource for LCs to identify painful breast conditions quickly, better manage their patients through triage, respond promptly to patient needs, and enhance the overall experience and care for breastfeeding mothers. Methods: We evaluated the potential for 5 classification models to detect breastfeeding-related conditions using 1078 breast and nipple images gathered from web-based and physical educational resources. We used the convolutional neural networks Resnet50, Visual Geometry Group model with 16 layers (VGG16), InceptionV3, EfficientNetV2, and DenseNet169 to classify the images across 7 classes: healthy, abscess, mastitis, nipple blebs, dermatosis, engorgement, and nipple damage by improper feeding or misuse of breast pumps. We also evaluated the models’ ability to distinguish between healthy and unhealthy images. We present an analysis of the classification challenges, identifying image traits that may confound the detection model. Results: The best model achieves an average area under the receiver operating characteristic curve of 0.93 for all conditions after data augmentation for multiclass classification. For binary classification, we achieved, with the best model, an average area under the curve of 0.96 for all conditions after data augmentation. Several factors contributed to the misclassification of images, including similar visual features in the conditions that precede other conditions (such as the mastitis spectrum disorder), partially covered breasts or nipples, and images depicting multiple conditions in the same breast. Conclusions: This vision-based automated detection technique offers an opportunity to enhance postpartum care for mothers and can potentially help alleviate the workload of LCs by expediting decision-making processes.
- Open Access
- 2 May 2024
- Published by Association for Computing Machinery (ACM)
- p. 1-7
LCBuddy: Towards a Smartphone-based Self-Assessment Tool for Postpartum Patients With Breast Pain
Telehealth has significantly enhanced various medical sectors, notably in postpartum care, by increasing breastfeeding rates and reducing postpartum depression. However, issues in patient management and triage, particularly in high-demand telehealth lactation consultations, lead to LC burnout, unnecessary costs and diagnostic delays. To address these challenges, this study introduces a pain assessment tool for telehealth lactation consultations, enhancing patient-provider communication through momentary assessment and AI mediation. It features a user interface with image quality assessment and condition classification algorithms, aiding remote diagnosis and triage. The tool guides patients and uses a severity-based feedback system, helping LCs prioritize cases. This method boosts tele-lactation service efficiency, streamlines LC workload, and serves as a model for specialized healthcare triaging. Future work includes refining the feedback system and evaluating the tool in clinical settings to standardize symptom severity grading and estimate its impact, potentially improving expert patient triaging in remote healthcare settings.
- 2 May 2024
- Published by Association for Computing Machinery (ACM)
- p. 1-7
Open AccessLCBuddy: Towards a Smartphone-based Self-Assessment Tool for Postpartum Patients With Breast Pain
Telehealth has significantly enhanced various medical sectors, notably in postpartum care, by increasing breastfeeding rates and reducing postpartum depression. However, issues in patient management and triage, particularly in high-demand telehealth lactation consultations, lead to LC burnout, unnecessary costs and diagnostic delays. To address these challenges, this study introduces a pain assessment tool for telehealth lactation consultations, enhancing patient-provider communication through momentary assessment and AI mediation. It features a user interface with image quality assessment and condition classification algorithms, aiding remote diagnosis and triage. The tool guides patients and uses a severity-based feedback system, helping LCs prioritize cases. This method boosts tele-lactation service efficiency, streamlines LC workload, and serves as a model for specialized healthcare triaging. Future work includes refining the feedback system and evaluating the tool in clinical settings to standardize symptom severity grading and estimate its impact, potentially improving expert patient triaging in remote healthcare settings.