Colin Barry
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Colin Barry has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Edward Jay Wang
University of California San Diego
3 shared publications - Ava Jean Fascetti
University of California San Diego
2 shared publications - Amparo Averbuj
UC San Diego, La Jolla, California, USA
1 shared publication - Anusha Rao
University of California San Diego, La Jolla, California, USA
1 shared publication - Jade Chng
Duke University
1 shared publication - Tatsuo Kumamoto
Billion Labs Inc., La Jolla, California, United States
1 shared publication
Latest Publications
- Open Access
- 12 October 2025
- Published by Association for Computing Machinery (ACM)
- p. 377-381
Far Red Postables: Ultra-low-cost Pupillometry
- 12 October 2025
- Published by Association for Computing Machinery (ACM)
- p. 377-381
Open AccessFar Red Postables: Ultra-low-cost Pupillometry
- Open Access
- 5 October 2024
- Published by Association for Computing Machinery (ACM)
- p. 147-151
Development of a One Dollar Blood Pressure Monitor
BPClip is an ultra-low-cost cuffless blood pressure monitor. As a universal smartphone attachment, BPClip leverages the computational imaging power of smartphones to perform oscillometry based blood pressure measurements. This paper examines different design considerations in BPClip's development. The cost and accuracy of blood pressure measurements are the central design goals. Both requirements are achieved with the initial prototype that achieves a 0.80 USD material cost and a mean absolute error of 8.72 and 5.49 mmHg for systolic and diastolic blood pressure, respectively. Since a main motivator to develop BPClip is making blood pressure monitoring more accessible, usability is also central to the design. User studies were conducted throughout the design process to inform the most intuitive and accessible design features. In this paper, we demystify the design process to share effective design practices with future developers working towards expanding health monitoring access beyond traditional clinical settings.
- 5 October 2024
- Published by Association for Computing Machinery (ACM)
- p. 147-151
Open AccessDevelopment of a One Dollar Blood Pressure Monitor
BPClip is an ultra-low-cost cuffless blood pressure monitor. As a universal smartphone attachment, BPClip leverages the computational imaging power of smartphones to perform oscillometry based blood pressure measurements. This paper examines different design considerations in BPClip's development. The cost and accuracy of blood pressure measurements are the central design goals. Both requirements are achieved with the initial prototype that achieves a 0.80 USD material cost and a mean absolute error of 8.72 and 5.49 mmHg for systolic and diastolic blood pressure, respectively. Since a main motivator to develop BPClip is making blood pressure monitoring more accessible, usability is also central to the design. User studies were conducted throughout the design process to inform the most intuitive and accessible design features. In this paper, we demystify the design process to share effective design practices with future developers working towards expanding health monitoring access beyond traditional clinical settings.
- Open Access
- 5 October 2024
- Published by Association for Computing Machinery (ACM)
- p. 220-224
VibroBP: An Oscillometric Smartphone Blood Pressure App
This interactivity features a smartphone-based method for measuring blood pressure (BP) using the oscillometric method. To measure BP, it is necessary to measure (1) the pressure applied to the artery and (2) the local blood volume change. This is accomplished by performing an oscillometric measurement at the finger's digital artery, whereby a user presses down on the phone's camera with steadily increasing force. The camera is used to capture the blood volume change using photoplethysmography. We devised a novel method for measuring the force applied by the finger without the use of specialized smartphone hardware with a technique called Vibrometric Force Estimation (VFE). The fundamental concept of VFE relies on a phenomenon where a vibrating object is dampened when an external force is applied on it. This phenomenon can be recreated using the phone's own vibration motor, where the resulting damped vibration is measured using the smartphone's Inertial Measurement Unit (IMU). A cross device reliability study with three smartphones of different manufacturers, shape, and prices results in similar force estimation performance across all smartphone models. In an N=24 validation study of the BP measurement, the smartphone technique achieves a MAE of 8.4 mmHg and 8.5 mmHg of systolic and diastolic BP, respectively, compared to an FDA approved BP cuff. The mean error (bias) and standard deviation are 0.44±10.2 mmHg and 0.03±10.5mmHg for systolic and diastolic, respectively. The vision for this technology is not necessarily to replace existing BP monitoring solutions, but rather to introduce a downloadable smartphone software application that could serve as a low-barrier hypertension screening measurement fit for widespread adoption.
- 5 October 2024
- Published by Association for Computing Machinery (ACM)
- p. 220-224
Open AccessVibroBP: An Oscillometric Smartphone Blood Pressure App
This interactivity features a smartphone-based method for measuring blood pressure (BP) using the oscillometric method. To measure BP, it is necessary to measure (1) the pressure applied to the artery and (2) the local blood volume change. This is accomplished by performing an oscillometric measurement at the finger's digital artery, whereby a user presses down on the phone's camera with steadily increasing force. The camera is used to capture the blood volume change using photoplethysmography. We devised a novel method for measuring the force applied by the finger without the use of specialized smartphone hardware with a technique called Vibrometric Force Estimation (VFE). The fundamental concept of VFE relies on a phenomenon where a vibrating object is dampened when an external force is applied on it. This phenomenon can be recreated using the phone's own vibration motor, where the resulting damped vibration is measured using the smartphone's Inertial Measurement Unit (IMU). A cross device reliability study with three smartphones of different manufacturers, shape, and prices results in similar force estimation performance across all smartphone models. In an N=24 validation study of the BP measurement, the smartphone technique achieves a MAE of 8.4 mmHg and 8.5 mmHg of systolic and diastolic BP, respectively, compared to an FDA approved BP cuff. The mean error (bias) and standard deviation are 0.44±10.2 mmHg and 0.03±10.5mmHg for systolic and diastolic, respectively. The vision for this technology is not necessarily to replace existing BP monitoring solutions, but rather to introduce a downloadable smartphone software application that could serve as a low-barrier hypertension screening measurement fit for widespread adoption.
- Open Access
- 5 October 2024
- Published by Association for Computing Machinery (ACM)
- p. 296-300
Expanding Clinically Relevant Health Monitoring
My proposed thesis topic focuses on two smartphone measurements: BP and HGS. These measurement of BP and HGS are similar because both measurements require the user to apply force to the smartphone. The BP measurement is performed at the fingertip and requires the user to apply force onto the digital artery. The HGS measurement requires users to squeeze the smartphone with their hand. HGS is important as a measure of fragility in clinical settings, which is particularly relevant for predicting surgical outcomes and determining surgical readiness. Both these metrics rely on a novel technique of measuring applied force on a smartphone coined "Vibrometric Force Estimation." This technique involves vibrating the smartphone and measuring how much the vibration dampens as a result of the applied force. The vision for this work is to expand healthcare access to accurate and clinically relevant measurements, especially for low resource and high risk populations.
- 5 October 2024
- Published by Association for Computing Machinery (ACM)
- p. 296-300
Open AccessExpanding Clinically Relevant Health Monitoring
My proposed thesis topic focuses on two smartphone measurements: BP and HGS. These measurement of BP and HGS are similar because both measurements require the user to apply force to the smartphone. The BP measurement is performed at the fingertip and requires the user to apply force onto the digital artery. The HGS measurement requires users to squeeze the smartphone with their hand. HGS is important as a measure of fragility in clinical settings, which is particularly relevant for predicting surgical outcomes and determining surgical readiness. Both these metrics rely on a novel technique of measuring applied force on a smartphone coined "Vibrometric Force Estimation." This technique involves vibrating the smartphone and measuring how much the vibration dampens as a result of the applied force. The vision for this work is to expand healthcare access to accurate and clinically relevant measurements, especially for low resource and high risk populations.