Tamara Valenčič
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tamara Valenčič has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Jakob Škarabot
School of Sport, Exercise and Health Sciences Loughborough University Loughborough UK
9 shared publications - Aleš Holobar
Faculty of Electrical Engineering and Computer Science, University of Maribor, 2000 Maribor, Slovenia
4 shared publications - Gregory E. P. Pearcey
Department of Physical Therapy and Human Movement Sciences, Feinberg School of Medicine Northwestern University Chicago Illinois USA
3 shared publications - Jonathan P. Folland
School of Sport, Exercise and Health Sciences, Loughborough University, Loughborough, UK
3 shared publications - Christopher D. Connelly
School of Sport, Exercise and Health Sciences, Loughborough University, Loughborough, UK
2 shared publications - Haydn Thomason
School of Sport, Exercise and Health Sciences, Loughborough University, Loughborough, UK
2 shared publications
Latest Publications
- Open Access
Reduction in Ia afferent input via ischaemia alters motor unit discharge characteristics and estimates of persistent inward currents
Persistent inward currents (PICs) govern motoneuron output and are influenced by diffuse neuromodulation and local inhibition. When large diameter afferent feedback is lost, as in some neurological conditions, PICs might additionally amplify and prolong synaptic inputs. Here, we examined whether reducing Ia afferent transmission via ischaemic nerve block alters PIC contribution to tibialis anterior (TA) motor unit (MU) discharge. Across two experiments 12 adults (5 female) performed triangular-shaped isometric dorsiflexion to 30% (Experiments 1 and 2) and 50% (Experiment 2) maximum voluntary force (MVF) at baseline, after a 20-minute rest (control), and during occlusion after inducing an ischaemic nerve block, confirmed by abolition of the soleus H-reflex. TA myoelectrical activity measured during contractions was decomposed into MU spike trains, and from smoothed MU discharges, discharge rate hysteresis (ΔF) and ascending non-linearity (brace height) were quantified. Results from Experiment 1 involving contractions matched to absolute force levels revealed increased peak discharge rate, ΔF, and brace height post-occlusion. However, ΔF normalised to maximal theoretical hysteresis did not change across time points. In Experiment 2, where MVF was reassessed at each timepoint and contractions were matched to relative force, peak discharge rate, normalised ΔF and brace height increased post-occlusion compared to pre-, across both contraction intensities. ΔF only increased post-occlusion at 50% MVF, with no changes at 30% MVF. These results show that ischaemic block of large-diameter axons, likely reducing reciprocal inhibition, increases PIC contribution to discharge rate modulation, highlighting the role of Ia afferent input in shaping motoneuron output in humans.
Open AccessReduction in Ia afferent input via ischaemia alters motor unit discharge characteristics and estimates of persistent inward currents
Persistent inward currents (PICs) govern motoneuron output and are influenced by diffuse neuromodulation and local inhibition. When large diameter afferent feedback is lost, as in some neurological conditions, PICs might additionally amplify and prolong synaptic inputs. Here, we examined whether reducing Ia afferent transmission via ischaemic nerve block alters PIC contribution to tibialis anterior (TA) motor unit (MU) discharge. Across two experiments 12 adults (5 female) performed triangular-shaped isometric dorsiflexion to 30% (Experiments 1 and 2) and 50% (Experiment 2) maximum voluntary force (MVF) at baseline, after a 20-minute rest (control), and during occlusion after inducing an ischaemic nerve block, confirmed by abolition of the soleus H-reflex. TA myoelectrical activity measured during contractions was decomposed into MU spike trains, and from smoothed MU discharges, discharge rate hysteresis (ΔF) and ascending non-linearity (brace height) were quantified. Results from Experiment 1 involving contractions matched to absolute force levels revealed increased peak discharge rate, ΔF, and brace height post-occlusion. However, ΔF normalised to maximal theoretical hysteresis did not change across time points. In Experiment 2, where MVF was reassessed at each timepoint and contractions were matched to relative force, peak discharge rate, normalised ΔF and brace height increased post-occlusion compared to pre-, across both contraction intensities. ΔF only increased post-occlusion at 50% MVF, with no changes at 30% MVF. These results show that ischaemic block of large-diameter axons, likely reducing reciprocal inhibition, increases PIC contribution to discharge rate modulation, highlighting the role of Ia afferent input in shaping motoneuron output in humans.
- 1 February 2026
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 140 (2) , 540-557
The modulation of human motoneuron discharge patterns with contraction force in resistance- and endurance-trained individuals
Physical training alters intrinsic motoneuron properties in reduced animal preparations, especially in neurons recruited at high excitation levels. Here, we show that individuals with a history of resistance or endurance training exhibit higher discharge rates that are more linear during forceful contractions. This likely reflects a more reciprocal/push-pull excitation-inhibition coupling, leading to greater net excitation to the motor pool that may contribute to greater force production observed in trained individuals.
- 1 February 2026
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 140 (2) , 540-557
The modulation of human motoneuron discharge patterns with contraction force in resistance- and endurance-trained individuals
Physical training alters intrinsic motoneuron properties in reduced animal preparations, especially in neurons recruited at high excitation levels. Here, we show that individuals with a history of resistance or endurance training exhibit higher discharge rates that are more linear during forceful contractions. This likely reflects a more reciprocal/push-pull excitation-inhibition coupling, leading to greater net excitation to the motor pool that may contribute to greater force production observed in trained individuals.
- 1 January 2026
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 140 (1) , 322-337
Motor unit discharge properties of the vastii muscles and their modulation with contraction level depend on the knee-joint angle
This study explored the relationship between motoneuron output to the vastii muscles at different knee-joint angles (quadriceps lengths) and isometric contraction levels. We showed that the motor unit discharge rate was lowest at the angle of the greatest absolute torque capacity, whereas the contraction-level-induced increases in discharge rate and motoneuron excitability were the greatest in the flexed position. These findings suggest that joint-angle-dependent adjustments in sensory feedback modulate motor control of the knee-extensor muscles.
- 1 January 2026
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 140 (1) , 322-337
Motor unit discharge properties of the vastii muscles and their modulation with contraction level depend on the knee-joint angle
This study explored the relationship between motoneuron output to the vastii muscles at different knee-joint angles (quadriceps lengths) and isometric contraction levels. We showed that the motor unit discharge rate was lowest at the angle of the greatest absolute torque capacity, whereas the contraction-level-induced increases in discharge rate and motoneuron excitability were the greatest in the flexed position. These findings suggest that joint-angle-dependent adjustments in sensory feedback modulate motor control of the knee-extensor muscles.
- Open Access
- 20 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 33 (15344320) , 3367-3376
The Efficiency of Manual Editing of High-Density Surface Electromyogram Decomposition Depends on the Recorded Muscle and Contraction Level but Less on the Operator’s Experience
We investigated the agreement and accuracy of manual editing of the high-density electromyogram (hdEMG) decomposition results by seven human operators with various experience levels. All operators edited the same automatically decomposed experimental hdEMG from the first dorsal interosseous (FDI), tibialis anterior (TA), vastus lateralis (VL), and biceps brachii (BB) muscles, and synthetic hdEMG from soleus (SO) and BB muscles at 10%, 30%, 50% and 70% of maximum voluntary contraction. On average, operators kept 13.7 ± 7.4 motor units (MUs) after editing and demonstrated relatively large disagreement in the calculated MU pulse trains (normalized root mean square difference) but relatively high agreement in the identified MU discharges. Inter-operator agreement positively correlated with the initial MU Pulse-to-Noise Ratio used as a quality measure of automatic MU identification, and negatively correlated with the muscle contraction level. Operators agreed more on the results of the simulated than experimental hdEMG. Among the experimental muscles tested, the greatest agreement was demonstrated for VL and the lowest for BB. We obtained similar results when comparing editing to the results of the most experienced operator and to ground truth in simulated cases: the greatest precision and sensitivity were demonstrated for VL, and the lowest for BB. The level of the operator’s experience had a significant impact on the editing of synthetic hdEMG and the detection of the first MU discharge, but not on the rate of agreement or editing time of experimental hdEMG.
- 20 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 33 (15344320) , 3367-3376
Open AccessThe Efficiency of Manual Editing of High-Density Surface Electromyogram Decomposition Depends on the Recorded Muscle and Contraction Level but Less on the Operator’s Experience
We investigated the agreement and accuracy of manual editing of the high-density electromyogram (hdEMG) decomposition results by seven human operators with various experience levels. All operators edited the same automatically decomposed experimental hdEMG from the first dorsal interosseous (FDI), tibialis anterior (TA), vastus lateralis (VL), and biceps brachii (BB) muscles, and synthetic hdEMG from soleus (SO) and BB muscles at 10%, 30%, 50% and 70% of maximum voluntary contraction. On average, operators kept 13.7 ± 7.4 motor units (MUs) after editing and demonstrated relatively large disagreement in the calculated MU pulse trains (normalized root mean square difference) but relatively high agreement in the identified MU discharges. Inter-operator agreement positively correlated with the initial MU Pulse-to-Noise Ratio used as a quality measure of automatic MU identification, and negatively correlated with the muscle contraction level. Operators agreed more on the results of the simulated than experimental hdEMG. Among the experimental muscles tested, the greatest agreement was demonstrated for VL and the lowest for BB. We obtained similar results when comparing editing to the results of the most experienced operator and to ground truth in simulated cases: the greatest precision and sensitivity were demonstrated for VL, and the lowest for BB. The level of the operator’s experience had a significant impact on the editing of synthetic hdEMG and the detection of the first MU discharge, but not on the rate of agreement or editing time of experimental hdEMG.
- Open Access
Training-induced alterations in the modulation of human motoneuron discharge patterns with contraction force
Motoneurons adapt to both resistance and endurance training in reduced animal preparations, with adaptations seemingly more apparent in higher threshold neurons, but similar evidence in humans is lacking. Here, we compared the identified motor unit (MU) discharge patterns from decomposed electromyography signals acquired during triangular dorsiflexion contractions up to 70% of maximal voluntary force (MVF) between resistance-trained, endurance-trained, and untrained individuals (n=23 in each group). We then estimated intrinsic motoneuron properties and garnered insight about the proportion of excitatory, inhibitory, and neuromodulatory inputs contributing to motor commands across contraction intensities in each group. Participants also performed a task where a triangular contraction was superimposed onto a sustained one designed to challenge inhibitory control of dendritic persistent inward currents (PICs). Both trained groups demonstrated greater MU discharge rates with greater ascending discharge rate modulation during higher contraction forces (≥50% MVF), which were accompanied by more linear MU discharge patterns and greater post-acceleration attenuation slopes of the ascending discharge rates. No differences in discharge rate hysteresis or the discharge rate characteristics during the sombrero tasks between groups, suggesting no differences in neuromodulatory input. Conversely, resistance-compared to endurance-trained individuals exhibited greater acceleration slopes during lower contractions forces (≤50% MVF), indicating the possibility of enhanced initial activation of PICs. Collectively, the greater and more linear MU discharge patterns in the trained groups either suggests a more reciprocal (i.e., push-pull) excitation-inhibition coupling during higher contraction forces or enhanced excitatory synaptic input to the motor pool, which might underpin greater force production of trained individuals.
Open AccessTraining-induced alterations in the modulation of human motoneuron discharge patterns with contraction force
Motoneurons adapt to both resistance and endurance training in reduced animal preparations, with adaptations seemingly more apparent in higher threshold neurons, but similar evidence in humans is lacking. Here, we compared the identified motor unit (MU) discharge patterns from decomposed electromyography signals acquired during triangular dorsiflexion contractions up to 70% of maximal voluntary force (MVF) between resistance-trained, endurance-trained, and untrained individuals (n=23 in each group). We then estimated intrinsic motoneuron properties and garnered insight about the proportion of excitatory, inhibitory, and neuromodulatory inputs contributing to motor commands across contraction intensities in each group. Participants also performed a task where a triangular contraction was superimposed onto a sustained one designed to challenge inhibitory control of dendritic persistent inward currents (PICs). Both trained groups demonstrated greater MU discharge rates with greater ascending discharge rate modulation during higher contraction forces (≥50% MVF), which were accompanied by more linear MU discharge patterns and greater post-acceleration attenuation slopes of the ascending discharge rates. No differences in discharge rate hysteresis or the discharge rate characteristics during the sombrero tasks between groups, suggesting no differences in neuromodulatory input. Conversely, resistance-compared to endurance-trained individuals exhibited greater acceleration slopes during lower contractions forces (≤50% MVF), indicating the possibility of enhanced initial activation of PICs. Collectively, the greater and more linear MU discharge patterns in the trained groups either suggests a more reciprocal (i.e., push-pull) excitation-inhibition coupling during higher contraction forces or enhanced excitatory synaptic input to the motor pool, which might underpin greater force production of trained individuals.
- Open Access
Motor unit discharge properties of the vastii muscles and their modulation with contraction level depend on the knee-joint angle
This study examined the effect of the knee-joint angle on motor unit (MU) discharge properties of the vastii muscles and their modulation with contraction level. Twelve young adults performed unilateral isometric knee-extension contractions during three experimental sessions at either 25, 55, and 85° of knee flexion (full extension: 0°) in a randomised order. Each session involved maximal voluntary contractions (MVCs) followed by submaximal trapezoidal and triangular contractions at different levels relative to maximal voluntary torque (MVT). High-density surface electromyograms were recorded from vastus lateralis and medialis muscles and, subsequently, decomposed to obtain discharge timings of individual MUs. MVT was the greatest, whereas MU discharge rate (DR) during MVCs and submaximal contraction levels (≥30% MVT) was the lowest at the intermediate joint angle (55°). The highest DR during MVCs and high-level contractions (70% MVT), however, was at the most flexed knee position (85°), which was due to a greater DR increase 50-70% MVT compared to 25° and 55°. The onset-offset DR hysteresis (ΔF), an estimate of persistent inward current contribution to motoneuron discharge, decreased with knee flexion and increased with contraction level, whereas the degree of motoneuron input-output nonlinearity (brace height) did not vary with joint angle but decreased with contraction level. At 85°, ΔF increased more and brace height decreased less with contraction level compared to 25° and 55°. These findings indicate that vastii MU DR and its modulation with contraction level vary with knee-joint angle, which could be partly explained by the modulation of motoneuron intrinsic electrical properties. NEW & NOTEWORTHY This study explored the relationship between motoneuron output to the vastii muscles at different knee-joint angles (quadriceps lengths) and isometric contraction levels. We showed that the motor unit discharge rate was lowest at the angle of the greatest absolute torque capacity, whereas the contraction-level-induced increases in discharge rate and motoneuron excitability were the greatest in the flexed position. These findings suggest that joint-angle-dependent adjustments in sensory feedback modulate motor control of the knee-extensor muscles.
Open AccessMotor unit discharge properties of the vastii muscles and their modulation with contraction level depend on the knee-joint angle
This study examined the effect of the knee-joint angle on motor unit (MU) discharge properties of the vastii muscles and their modulation with contraction level. Twelve young adults performed unilateral isometric knee-extension contractions during three experimental sessions at either 25, 55, and 85° of knee flexion (full extension: 0°) in a randomised order. Each session involved maximal voluntary contractions (MVCs) followed by submaximal trapezoidal and triangular contractions at different levels relative to maximal voluntary torque (MVT). High-density surface electromyograms were recorded from vastus lateralis and medialis muscles and, subsequently, decomposed to obtain discharge timings of individual MUs. MVT was the greatest, whereas MU discharge rate (DR) during MVCs and submaximal contraction levels (≥30% MVT) was the lowest at the intermediate joint angle (55°). The highest DR during MVCs and high-level contractions (70% MVT), however, was at the most flexed knee position (85°), which was due to a greater DR increase 50-70% MVT compared to 25° and 55°. The onset-offset DR hysteresis (ΔF), an estimate of persistent inward current contribution to motoneuron discharge, decreased with knee flexion and increased with contraction level, whereas the degree of motoneuron input-output nonlinearity (brace height) did not vary with joint angle but decreased with contraction level. At 85°, ΔF increased more and brace height decreased less with contraction level compared to 25° and 55°. These findings indicate that vastii MU DR and its modulation with contraction level vary with knee-joint angle, which could be partly explained by the modulation of motoneuron intrinsic electrical properties. NEW & NOTEWORTHY This study explored the relationship between motoneuron output to the vastii muscles at different knee-joint angles (quadriceps lengths) and isometric contraction levels. We showed that the motor unit discharge rate was lowest at the angle of the greatest absolute torque capacity, whereas the contraction-level-induced increases in discharge rate and motoneuron excitability were the greatest in the flexed position. These findings suggest that joint-angle-dependent adjustments in sensory feedback modulate motor control of the knee-extensor muscles.
- Open Access
- 15 April 2024
- Published by Wiley in The Journal of Physiology
- Vol. 602 (10) , 2287-2314
Motor unit discharge rate modulation during isometric contractions to failure is intensity‐ and modality‐dependent
The physiological mechanisms determining the progressive decline in the maximal muscle torque production capacity during isometric contractions to task failure are known to depend on task demands. Task‐specificity of the associated adjustments in motor unit discharge rate (MUDR), however, remains unclear. This study examined MUDR adjustments during different submaximal isometric knee extension tasks to failure. Participants performed a sustained and an intermittent task at 20% and 50% of maximal voluntary torque (MVT), respectively (Experiment 1). High‐density surface EMG signals were recorded from vastus lateralis (VL) and medialis (VM) and decomposed into individual MU discharge timings, with the identified MUs tracked from recruitment to task failure. MUDR was quantified and normalised to intervals of 10% of contraction time (CT). MUDR of both muscles exhibited distinct modulation patterns in each task. During the 20% MVT sustained task, MUDR decreased until ∼50% CT, after which it gradually returned to baseline. Conversely, during the 50% MVT intermittent task, MUDR remained stable until ∼40–50% CT, after which it started to continually increase until task failure. To explore the effect of contraction intensity on the observed patterns, VL and VM MUDR was quantified during sustained contractions at 30% and 50% MVT (Experiment 2). During the 30% MVT sustained task, MUDR remained stable until ∼80–90% CT in both muscles, after which it continually increased until task failure. During the 50% MVT sustained task the increase in MUDR occurred earlier, after ∼70–80% CT. Our results suggest that adjustments in MUDR during submaximal isometric contractions to failure are contraction modality‐ and intensity‐dependent. image Key points: During prolonged muscle contractions a constant motor output can be maintained by recruitment of additional motor units and adjustments in their discharge rate. Whilst contraction‐induced decrements in neuromuscular function are known to depend on task demands, task‐specificity of motor unit discharge behaviour adjustments is still unclear. In this study, we tracked and compared discharge activity of several concurrently active motor units in the vastii muscles during different submaximal isometric knee extension tasks to failure, including intermittent vs. sustained contraction modalities performed in the same intensity domain (Experiment 1), and two sustained contractions performed at different intensities (Experiment 2). During each task, motor units modulated their discharge rate in a distinct, biphasic manner, with the modulation pattern depending on contraction intensity and modality. These results provide insight into motoneuronal adjustments during contraction tasks posing different demands on the neuromuscular system.
- 15 April 2024
- Published by Wiley in The Journal of Physiology
- Vol. 602 (10) , 2287-2314
Open AccessMotor unit discharge rate modulation during isometric contractions to failure is intensity‐ and modality‐dependent
The physiological mechanisms determining the progressive decline in the maximal muscle torque production capacity during isometric contractions to task failure are known to depend on task demands. Task‐specificity of the associated adjustments in motor unit discharge rate (MUDR), however, remains unclear. This study examined MUDR adjustments during different submaximal isometric knee extension tasks to failure. Participants performed a sustained and an intermittent task at 20% and 50% of maximal voluntary torque (MVT), respectively (Experiment 1). High‐density surface EMG signals were recorded from vastus lateralis (VL) and medialis (VM) and decomposed into individual MU discharge timings, with the identified MUs tracked from recruitment to task failure. MUDR was quantified and normalised to intervals of 10% of contraction time (CT). MUDR of both muscles exhibited distinct modulation patterns in each task. During the 20% MVT sustained task, MUDR decreased until ∼50% CT, after which it gradually returned to baseline. Conversely, during the 50% MVT intermittent task, MUDR remained stable until ∼40–50% CT, after which it started to continually increase until task failure. To explore the effect of contraction intensity on the observed patterns, VL and VM MUDR was quantified during sustained contractions at 30% and 50% MVT (Experiment 2). During the 30% MVT sustained task, MUDR remained stable until ∼80–90% CT in both muscles, after which it continually increased until task failure. During the 50% MVT sustained task the increase in MUDR occurred earlier, after ∼70–80% CT. Our results suggest that adjustments in MUDR during submaximal isometric contractions to failure are contraction modality‐ and intensity‐dependent. image Key points: During prolonged muscle contractions a constant motor output can be maintained by recruitment of additional motor units and adjustments in their discharge rate. Whilst contraction‐induced decrements in neuromuscular function are known to depend on task demands, task‐specificity of motor unit discharge behaviour adjustments is still unclear. In this study, we tracked and compared discharge activity of several concurrently active motor units in the vastii muscles during different submaximal isometric knee extension tasks to failure, including intermittent vs. sustained contraction modalities performed in the same intensity domain (Experiment 1), and two sustained contractions performed at different intensities (Experiment 2). During each task, motor units modulated their discharge rate in a distinct, biphasic manner, with the modulation pattern depending on contraction intensity and modality. These results provide insight into motoneuronal adjustments during contraction tasks posing different demands on the neuromuscular system.
- Open Access
- 9 April 2024
- Published by SAGE Publications in The American Journal of Sports Medicine
- Vol. 52 (14) , 3641-3650
Comparison of Blood Flow Restriction Interventions to Standard Rehabilitation After an Anterior Cruciate Ligament Injury: A Systematic Review
Background: Blood flow restriction training (BFR-t) data are heterogeneous. It is unclear whether rehabilitation with BFR-t after an anterior cruciate ligament (ACL) injury is more effective in improving muscle strength and muscle size than standard rehabilitation. Purpose: To review outcomes after an ACL injury and subsequent reconstruction in studies comparing rehabilitation with and without BFR-t. Study Design: Systematic review. Level of evidence, 3. Methods: A search of English-language human clinical studies published in the past 20 years (2002-2022) was carried out in 5 health sciences databases, involving participants aged 18-65 undergoing rehabilitation for an ACL injury. Outcomes associated with muscle strength, muscle size, and knee-specific patient-reported outcome measures (PROMs) were extracted from studies meeting inclusion criteria and compared. Results: The literature search identified 279 studies, of which 5 met the selection criteria. Two studies suggested that BFR-t rehabilitation after an ACL injury improved knee or thigh muscle strength and muscle size compared with rehabilitation consisting of comparable and higher load resistance training, with two studies suggesting the opposite. The single study measuring PROMs showed improvement compared to traditional rehabilitation, with no difference in muscle strength or size. Conclusion: BFR-t after an ACL injury seems to benefit muscle strength, muscle size, and PROM scores compared with standard rehabilitation alone. However, only 1 large study included all these outcomes, which has yet to be replicated in other settings. Further studies utilizing similar methods with a common set of outcome measures are required to confirm the effects of BFR-t on ACL rehabilitation.
- 9 April 2024
- Published by SAGE Publications in The American Journal of Sports Medicine
- Vol. 52 (14) , 3641-3650
Open AccessComparison of Blood Flow Restriction Interventions to Standard Rehabilitation After an Anterior Cruciate Ligament Injury: A Systematic Review
Background: Blood flow restriction training (BFR-t) data are heterogeneous. It is unclear whether rehabilitation with BFR-t after an anterior cruciate ligament (ACL) injury is more effective in improving muscle strength and muscle size than standard rehabilitation. Purpose: To review outcomes after an ACL injury and subsequent reconstruction in studies comparing rehabilitation with and without BFR-t. Study Design: Systematic review. Level of evidence, 3. Methods: A search of English-language human clinical studies published in the past 20 years (2002-2022) was carried out in 5 health sciences databases, involving participants aged 18-65 undergoing rehabilitation for an ACL injury. Outcomes associated with muscle strength, muscle size, and knee-specific patient-reported outcome measures (PROMs) were extracted from studies meeting inclusion criteria and compared. Results: The literature search identified 279 studies, of which 5 met the selection criteria. Two studies suggested that BFR-t rehabilitation after an ACL injury improved knee or thigh muscle strength and muscle size compared with rehabilitation consisting of comparable and higher load resistance training, with two studies suggesting the opposite. The single study measuring PROMs showed improvement compared to traditional rehabilitation, with no difference in muscle strength or size. Conclusion: BFR-t after an ACL injury seems to benefit muscle strength, muscle size, and PROM scores compared with standard rehabilitation alone. However, only 1 large study included all these outcomes, which has yet to be replicated in other settings. Further studies utilizing similar methods with a common set of outcome measures are required to confirm the effects of BFR-t on ACL rehabilitation.
- Open Access
Motor unit discharge rate modulation during isometric contractions to failure is intensity and task dependent
The nature of neuromuscular decrements associated with contractions to task failure is known to dependent on task demands. Task-specificity of the associated adjustments in motor unit discharge rate (MUDR) behaviour, however, remains unclear. This study examined MUDR adjustments during different submaximal isometric knee-extension tasks to failure. Participants performed a sustained and an intermittent task at 20 and 50% of maximal voluntary torque (MVT), respectively (Experiment 1). High-density surface electromyography signals were recorded from vastus lateralis (VL) and medialis (VM) and decomposed into individual MU discharge timings, with the identified MUs tracked from recruitment to task failure. MUDR was quantified and normalised to intervals of 10% of contraction time (CT). MUDR of both muscles exhibited distinct modulation patterns in each task. During 20% MVT sustained task, MUDR decreased until ∼50% CT, after which it gradually returned to baseline. Conversely, during the 50% MVT intermittent task, MUDR remained stable until ∼40-50% CT, after which it started to continually increase until task failure. To explore the effect of contraction intensity on the observed patterns, VL and VM MUDR was quantified during sustained contractions at 30 and 50% MVT (Experiment 2). During the 30% MVT sustained task, MUDR remained stable until ∼80-90% CT in both muscles, after which it continually increased until task failure. During the 50% MVT sustained task the increase in MUDR occurred earlier, after ∼70-80% CT. Our results suggest that adjustments in MUDR during submaximal isometric contractions to failure are task- and intensity-dependent.
Open AccessMotor unit discharge rate modulation during isometric contractions to failure is intensity and task dependent
The nature of neuromuscular decrements associated with contractions to task failure is known to dependent on task demands. Task-specificity of the associated adjustments in motor unit discharge rate (MUDR) behaviour, however, remains unclear. This study examined MUDR adjustments during different submaximal isometric knee-extension tasks to failure. Participants performed a sustained and an intermittent task at 20 and 50% of maximal voluntary torque (MVT), respectively (Experiment 1). High-density surface electromyography signals were recorded from vastus lateralis (VL) and medialis (VM) and decomposed into individual MU discharge timings, with the identified MUs tracked from recruitment to task failure. MUDR was quantified and normalised to intervals of 10% of contraction time (CT). MUDR of both muscles exhibited distinct modulation patterns in each task. During 20% MVT sustained task, MUDR decreased until ∼50% CT, after which it gradually returned to baseline. Conversely, during the 50% MVT intermittent task, MUDR remained stable until ∼40-50% CT, after which it started to continually increase until task failure. To explore the effect of contraction intensity on the observed patterns, VL and VM MUDR was quantified during sustained contractions at 30 and 50% MVT (Experiment 2). During the 30% MVT sustained task, MUDR remained stable until ∼80-90% CT in both muscles, after which it continually increased until task failure. During the 50% MVT sustained task the increase in MUDR occurred earlier, after ∼70-80% CT. Our results suggest that adjustments in MUDR during submaximal isometric contractions to failure are task- and intensity-dependent.