Haydn Thomason
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Haydn Thomason has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Christopher D. Connelly
School of Sport, Exercise and Health Sciences, Loughborough University, Loughborough, UK
2 shared publications - Jakob Škarabot
School of Sport, Exercise and Health Sciences Loughborough University Loughborough UK
2 shared publications - Tamara Valenčič
School of Sport, Exercise and Health Sciences, Loughborough University, Loughborough, UK
2 shared publications - Aleš Holobar
Faculty of Electrical Engineering and Computer Science, University of Maribor, 2000 Maribor, Slovenia
1 shared publication Gašper Sedej
Faculty of Electrical Engineering and Computer Science, University of Maribor, Maribor, Slovenia
1 shared publication- Gregory E. P. Pearcey
Department of Physical Therapy and Human Movement Sciences, Feinberg School of Medicine Northwestern University Chicago Illinois USA
1 shared publication
Latest Publications
- Open Access
Reduction in Ia afferent input via ischaemia alters motor unit discharge characteristics and estimates of persistent inward currents
Persistent inward currents (PICs) govern motoneuron output and are influenced by diffuse neuromodulation and local inhibition. When large diameter afferent feedback is lost, as in some neurological conditions, PICs might additionally amplify and prolong synaptic inputs. Here, we examined whether reducing Ia afferent transmission via ischaemic nerve block alters PIC contribution to tibialis anterior (TA) motor unit (MU) discharge. Across two experiments 12 adults (5 female) performed triangular-shaped isometric dorsiflexion to 30% (Experiments 1 and 2) and 50% (Experiment 2) maximum voluntary force (MVF) at baseline, after a 20-minute rest (control), and during occlusion after inducing an ischaemic nerve block, confirmed by abolition of the soleus H-reflex. TA myoelectrical activity measured during contractions was decomposed into MU spike trains, and from smoothed MU discharges, discharge rate hysteresis (ΔF) and ascending non-linearity (brace height) were quantified. Results from Experiment 1 involving contractions matched to absolute force levels revealed increased peak discharge rate, ΔF, and brace height post-occlusion. However, ΔF normalised to maximal theoretical hysteresis did not change across time points. In Experiment 2, where MVF was reassessed at each timepoint and contractions were matched to relative force, peak discharge rate, normalised ΔF and brace height increased post-occlusion compared to pre-, across both contraction intensities. ΔF only increased post-occlusion at 50% MVF, with no changes at 30% MVF. These results show that ischaemic block of large-diameter axons, likely reducing reciprocal inhibition, increases PIC contribution to discharge rate modulation, highlighting the role of Ia afferent input in shaping motoneuron output in humans.
Open AccessReduction in Ia afferent input via ischaemia alters motor unit discharge characteristics and estimates of persistent inward currents
Persistent inward currents (PICs) govern motoneuron output and are influenced by diffuse neuromodulation and local inhibition. When large diameter afferent feedback is lost, as in some neurological conditions, PICs might additionally amplify and prolong synaptic inputs. Here, we examined whether reducing Ia afferent transmission via ischaemic nerve block alters PIC contribution to tibialis anterior (TA) motor unit (MU) discharge. Across two experiments 12 adults (5 female) performed triangular-shaped isometric dorsiflexion to 30% (Experiments 1 and 2) and 50% (Experiment 2) maximum voluntary force (MVF) at baseline, after a 20-minute rest (control), and during occlusion after inducing an ischaemic nerve block, confirmed by abolition of the soleus H-reflex. TA myoelectrical activity measured during contractions was decomposed into MU spike trains, and from smoothed MU discharges, discharge rate hysteresis (ΔF) and ascending non-linearity (brace height) were quantified. Results from Experiment 1 involving contractions matched to absolute force levels revealed increased peak discharge rate, ΔF, and brace height post-occlusion. However, ΔF normalised to maximal theoretical hysteresis did not change across time points. In Experiment 2, where MVF was reassessed at each timepoint and contractions were matched to relative force, peak discharge rate, normalised ΔF and brace height increased post-occlusion compared to pre-, across both contraction intensities. ΔF only increased post-occlusion at 50% MVF, with no changes at 30% MVF. These results show that ischaemic block of large-diameter axons, likely reducing reciprocal inhibition, increases PIC contribution to discharge rate modulation, highlighting the role of Ia afferent input in shaping motoneuron output in humans.
- Open Access
- 20 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 33 (15344320) , 3367-3376
The Efficiency of Manual Editing of High-Density Surface Electromyogram Decomposition Depends on the Recorded Muscle and Contraction Level but Less on the Operator’s Experience
We investigated the agreement and accuracy of manual editing of the high-density electromyogram (hdEMG) decomposition results by seven human operators with various experience levels. All operators edited the same automatically decomposed experimental hdEMG from the first dorsal interosseous (FDI), tibialis anterior (TA), vastus lateralis (VL), and biceps brachii (BB) muscles, and synthetic hdEMG from soleus (SO) and BB muscles at 10%, 30%, 50% and 70% of maximum voluntary contraction. On average, operators kept 13.7 ± 7.4 motor units (MUs) after editing and demonstrated relatively large disagreement in the calculated MU pulse trains (normalized root mean square difference) but relatively high agreement in the identified MU discharges. Inter-operator agreement positively correlated with the initial MU Pulse-to-Noise Ratio used as a quality measure of automatic MU identification, and negatively correlated with the muscle contraction level. Operators agreed more on the results of the simulated than experimental hdEMG. Among the experimental muscles tested, the greatest agreement was demonstrated for VL and the lowest for BB. We obtained similar results when comparing editing to the results of the most experienced operator and to ground truth in simulated cases: the greatest precision and sensitivity were demonstrated for VL, and the lowest for BB. The level of the operator’s experience had a significant impact on the editing of synthetic hdEMG and the detection of the first MU discharge, but not on the rate of agreement or editing time of experimental hdEMG.
- 20 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 33 (15344320) , 3367-3376
Open AccessThe Efficiency of Manual Editing of High-Density Surface Electromyogram Decomposition Depends on the Recorded Muscle and Contraction Level but Less on the Operator’s Experience
We investigated the agreement and accuracy of manual editing of the high-density electromyogram (hdEMG) decomposition results by seven human operators with various experience levels. All operators edited the same automatically decomposed experimental hdEMG from the first dorsal interosseous (FDI), tibialis anterior (TA), vastus lateralis (VL), and biceps brachii (BB) muscles, and synthetic hdEMG from soleus (SO) and BB muscles at 10%, 30%, 50% and 70% of maximum voluntary contraction. On average, operators kept 13.7 ± 7.4 motor units (MUs) after editing and demonstrated relatively large disagreement in the calculated MU pulse trains (normalized root mean square difference) but relatively high agreement in the identified MU discharges. Inter-operator agreement positively correlated with the initial MU Pulse-to-Noise Ratio used as a quality measure of automatic MU identification, and negatively correlated with the muscle contraction level. Operators agreed more on the results of the simulated than experimental hdEMG. Among the experimental muscles tested, the greatest agreement was demonstrated for VL and the lowest for BB. We obtained similar results when comparing editing to the results of the most experienced operator and to ground truth in simulated cases: the greatest precision and sensitivity were demonstrated for VL, and the lowest for BB. The level of the operator’s experience had a significant impact on the editing of synthetic hdEMG and the detection of the first MU discharge, but not on the rate of agreement or editing time of experimental hdEMG.