Carlos Carrasquillo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Carlos Carrasquillo has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Aaron J. Young
Georgia Institute of Technology
3 shared publications - Aakash Bajpai
George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, USA
2 shared publications - Anirban Mazumdar
Georgia Institute of Technology
2 shared publications - Kinsey R. Herrin
Georgia Institute of Technology
2 shared publications Aaron Young
Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, USA
1 shared publicationDivya Iyengar
School of Mechanical Engineering, Georgia Institute of Technology, USA
1 shared publication
Latest Publications
- 19 November 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Robotics
- Vol. 10 (108) , eads8652
Deep domain adaptation eliminates costly data required for task-agnostic wearable robotic control
Data-driven methods have transformed our ability to assess and respond to human movement with wearable robots, promising real-world rehabilitation and augmentation benefits. However, the proliferation of data-driven methods, with the associated demand for increased personalization and performance, requires vast quantities of high-quality, device-specific data. Procuring these data is often intractable because of resource and personnel costs. We propose a framework that overcomes data scarcity by leveraging simulated sensors from biomechanical models to form a stepping-stone domain through which easily accessible data can be translated into data-limited domains. We developed and optimized a deep domain adaptation network that replaces costly, device-specific, labeled data with open-source datasets and unlabeled exoskeleton data. Using our network, we trained a hip and knee joint moment estimator with performance comparable to a best-case model trained with a complete, device-specific dataset [incurring only an 11 to 20%, 0.019 to 0.028 newton-meters per kilogram (Nm/kg) increase in error for a semisupervised model and 20 to 44%, 0.033 to 0.062 Nm/kg for an unsupervised model]. Our network significantly outperformed counterpart networks without domain adaptation (which incurred errors of 36 to 45% semisupervised and 50 to 60% unsupervised). Deploying our models in the real-time control loop of a hip/knee exoskeleton ( N = 8) demonstrated estimator performance similar to offline results while augmenting user performance based on those estimated moments (9.5 to 14.6% metabolic cost reductions compared with no exoskeleton). Our framework enables researchers to train real-time deployable deep learning, task-agnostic models with limited or no access to labeled, device-specific data.
- 19 November 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Robotics
- Vol. 10 (108) , eads8652
Deep domain adaptation eliminates costly data required for task-agnostic wearable robotic control
Data-driven methods have transformed our ability to assess and respond to human movement with wearable robots, promising real-world rehabilitation and augmentation benefits. However, the proliferation of data-driven methods, with the associated demand for increased personalization and performance, requires vast quantities of high-quality, device-specific data. Procuring these data is often intractable because of resource and personnel costs. We propose a framework that overcomes data scarcity by leveraging simulated sensors from biomechanical models to form a stepping-stone domain through which easily accessible data can be translated into data-limited domains. We developed and optimized a deep domain adaptation network that replaces costly, device-specific, labeled data with open-source datasets and unlabeled exoskeleton data. Using our network, we trained a hip and knee joint moment estimator with performance comparable to a best-case model trained with a complete, device-specific dataset [incurring only an 11 to 20%, 0.019 to 0.028 newton-meters per kilogram (Nm/kg) increase in error for a semisupervised model and 20 to 44%, 0.033 to 0.062 Nm/kg for an unsupervised model]. Our network significantly outperformed counterpart networks without domain adaptation (which incurred errors of 36 to 45% semisupervised and 50 to 60% unsupervised). Deploying our models in the real-time control loop of a hip/knee exoskeleton ( N = 8) demonstrated estimator performance similar to offline results while augmenting user performance based on those estimated moments (9.5 to 14.6% metabolic cost reductions compared with no exoskeleton). Our framework enables researchers to train real-time deployable deep learning, task-agnostic models with limited or no access to labeled, device-specific data.
- 5 June 2025
- Published by Wolters Kluwer Health in Prosthetics and Orthotics International
- Vol. 50 (4) , 401-409
A clinical decision-making algorithm for the personalized prescription of microprocessor-controlled prosthetic knees: An evidence-based approach based on a randomized trial
Background: Current processes for identifying the best microprocessor-controlled prosthetic knee (MPK) for individuals with transfemoral amputations are subjective, nonscientific, and sometimes fail to consider unique patient needs. Inaccurate prescriptions may hinder a patient's ability to make a speedy rehab. Objectives: We developed a clinical decision equation that outputs MPK recommendation scores for 3 commercially available MPKs (Power Knee, C-Leg 4.0, Rheo Knee) based on easily acquirable user evaluation data. Study design: Participants wore each of the study MPKs at home for a 1-week acclimation period. On the experiment day, participants completed a set of functional tasks including a 10-m walk test, stair and ramp ambulation tasks, a 2-minute walk test, and a narrow beam walking test. Performance outcome measures were collected. Methods: Microprocessor-controlled prosthetic knees were scored relatively to the best performing knee based on their performance in 5 areas of interest: agility, community ambulation, energy, stability, and gait quality. The relative importance of each of these areas was computed based on a quantitative prediction of a user's functional needs from features including age, body mass index (BMI), AMPnoPRO score, and likelihood of stairs/ramps. We describe the algorithm-suggested optimal patient profiles for each device. Results: We developed an application that allows clinicians to obtain instant recommendations. Clinicians can further adjust the relative importance of each area of interest based on patient needs. Conclusions: This algorithm represents a transparent, experimentally backed clinical decision-making aid with the potential to streamline the prosthesis fitting process. Future studies are required to evaluate the effectiveness of the algorithm.
- 5 June 2025
- Published by Wolters Kluwer Health in Prosthetics and Orthotics International
- Vol. 50 (4) , 401-409
A clinical decision-making algorithm for the personalized prescription of microprocessor-controlled prosthetic knees: An evidence-based approach based on a randomized trial
Background: Current processes for identifying the best microprocessor-controlled prosthetic knee (MPK) for individuals with transfemoral amputations are subjective, nonscientific, and sometimes fail to consider unique patient needs. Inaccurate prescriptions may hinder a patient's ability to make a speedy rehab. Objectives: We developed a clinical decision equation that outputs MPK recommendation scores for 3 commercially available MPKs (Power Knee, C-Leg 4.0, Rheo Knee) based on easily acquirable user evaluation data. Study design: Participants wore each of the study MPKs at home for a 1-week acclimation period. On the experiment day, participants completed a set of functional tasks including a 10-m walk test, stair and ramp ambulation tasks, a 2-minute walk test, and a narrow beam walking test. Performance outcome measures were collected. Methods: Microprocessor-controlled prosthetic knees were scored relatively to the best performing knee based on their performance in 5 areas of interest: agility, community ambulation, energy, stability, and gait quality. The relative importance of each of these areas was computed based on a quantitative prediction of a user's functional needs from features including age, body mass index (BMI), AMPnoPRO score, and likelihood of stairs/ramps. We describe the algorithm-suggested optimal patient profiles for each device. Results: We developed an application that allows clinicians to obtain instant recommendations. Clinicians can further adjust the relative importance of each area of interest based on patient needs. Conclusions: This algorithm represents a transparent, experimentally backed clinical decision-making aid with the potential to streamline the prosthesis fitting process. Future studies are required to evaluate the effectiveness of the algorithm.
- 27 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Haptics
- Vol. 18 (2) , 312-324
Enhancing Human Navigation Ability Using Force-Feedback From a Lower-Limb Exoskeleton
Humans operating in dynamic environments with limited visibility are susceptible to collisions with moving objects, occupational hazards, and/or other agents, which can result in personal injuries or fatalities. Most existing research has focused on using vibrotactile cues to address this challenge. In this work, we propose a fundamentally new approach that utilizes variable impedance on an active exoskeleton to guide humans away from hazards and towards safe areas. This framework combines artificial potential fields with current impedance-based theories of exoskeleton control to provide a comprehensive navigational system that is intuitive for human operators. First, we present the mathematical framework to encode information about the locations of obstacles and the safest direction in which to move. Next, we optimize controller parameters in a series of humansubject experiments. Finally, we evaluate the framework in virtual reality on a set of randomly generated obstacle fields in environments where vision is either fully or partially occluded. Our results suggest that the exoskeleton provides significant separation from obstacles and reduced collisions compared to vision alone in conditions where visibility was limited to less than 1.3 m. Our work demonstrates that force-feedback in parallel with a human can improve overall navigation ability in low visibility conditions
- 27 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Haptics
- Vol. 18 (2) , 312-324
Enhancing Human Navigation Ability Using Force-Feedback From a Lower-Limb Exoskeleton
Humans operating in dynamic environments with limited visibility are susceptible to collisions with moving objects, occupational hazards, and/or other agents, which can result in personal injuries or fatalities. Most existing research has focused on using vibrotactile cues to address this challenge. In this work, we propose a fundamentally new approach that utilizes variable impedance on an active exoskeleton to guide humans away from hazards and towards safe areas. This framework combines artificial potential fields with current impedance-based theories of exoskeleton control to provide a comprehensive navigational system that is intuitive for human operators. First, we present the mathematical framework to encode information about the locations of obstacles and the safest direction in which to move. Next, we optimize controller parameters in a series of humansubject experiments. Finally, we evaluate the framework in virtual reality on a set of randomly generated obstacle fields in environments where vision is either fully or partially occluded. Our results suggest that the exoskeleton provides significant separation from obstacles and reduced collisions compared to vision alone in conditions where visibility was limited to less than 1.3 m. Our work demonstrates that force-feedback in parallel with a human can improve overall navigation ability in low visibility conditions
- 5 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 29 (1) , 789-797
Design and Validation of a Versatile High Torque Quasidirect Drive Hip Exoskeleton
The field of wearable robotics has made significant progress toward augmenting human functions from multimodal ambulation to manual lifting tasks. However, most of these systems are designed to be task-specific and only focus on a single type of movement (e.g., ambulation). In this work, we design, fabricate, and characterize a versatile hip exoskeleton testbed for lifting and ambulation tasks. The exoskeleton testbed is actuated with custom-built quasidirect drive actuators. We produce an orthotic interface to transmit high torques and assemble a custom mechatronic control system for the exoskeleton testbed. We also detail controllers for level ground walking, incline walking, and symmetric knee to waist lifting. We quantify the actuator torque tracking performance quantified through benchtop and human experiments. During knee-to-waist cyclic lifting, the powered condition exhibited a 16.7% reduction in net metabolic cost compared to the no exoskeleton condition (three subjects). For additional tasks (inclined walking, level-walking), the device provided metabolic reductions when compared with the unpowered case (single subject). These testbed results illustrate the potential for versatile hip assistance and can be used to design future optimized devices.
- 5 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 29 (1) , 789-797
Design and Validation of a Versatile High Torque Quasidirect Drive Hip Exoskeleton
The field of wearable robotics has made significant progress toward augmenting human functions from multimodal ambulation to manual lifting tasks. However, most of these systems are designed to be task-specific and only focus on a single type of movement (e.g., ambulation). In this work, we design, fabricate, and characterize a versatile hip exoskeleton testbed for lifting and ambulation tasks. The exoskeleton testbed is actuated with custom-built quasidirect drive actuators. We produce an orthotic interface to transmit high torques and assemble a custom mechatronic control system for the exoskeleton testbed. We also detail controllers for level ground walking, incline walking, and symmetric knee to waist lifting. We quantify the actuator torque tracking performance quantified through benchtop and human experiments. During knee-to-waist cyclic lifting, the powered condition exhibited a 16.7% reduction in net metabolic cost compared to the no exoskeleton condition (three subjects). For additional tasks (inclined walking, level-walking), the device provided metabolic reductions when compared with the unpowered case (single subject). These testbed results illustrate the potential for versatile hip assistance and can be used to design future optimized devices.