Mojtaba Moghaddasi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mojtaba Moghaddasi has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Bin Hu
School of Optics and Photonics Beijing Institute of Technology Beijing China
4 shared publications Abdul Jalal
College of Integrated Circuits and Optoelectronic Chips Shenzhen Technology University Shenzhen China
2 shared publicationsChenjie Xiong
School of Optics and Photonics Beijing Institute of Technology Beijing China
2 shared publications- Fahimeh Abrinaei
Department of Physics, Central Tehran Branch, Islamic Azad University, Tehran, Iran
2 shared publications Jianzhou Huang
School of Optics and Photonics Beijing Institute of Technology Beijing China
2 shared publicationsXudong Wu
School of Optics and Photonics Beijing Institute of Technology Beijing China
2 shared publications
Latest Publications
- 28 November 2025
- Published by Wiley in Laser & Photonics Reviews
- Vol. 20 (7)
Metalens Enabled Compact and Wide‐Angle 3 × 3 Mueller Matrix Polarimetric Imaging for the Advanced Medical Applications
Recent advancements in nanofabrication technology and metalenses have enabled the miniaturization of polarization imaging devices. This study presents a novel polarization‐sensitive metalens design specifically engineered for endoscopy applications, focusing on the early diagnosis of gastrointestinal diseases, particularly cancer. The proposed system integrates three apertures and three distinct metalenses with polarization orientations of 0°, 45°, and 90°, facilitating comprehensive polarization analysis through Stokes parameters and 3 × 3 Mueller matrix imaging. In the conventional systems, 9 sequential images are required to construct a 3 × 3 Mueller matrix. In contrast, the metalens‐integrated system significantly reduces this requirement by capturing only three sequential images. The system achieves a modulation transfer function of 0.2 at 450 lp/mm with a 70° field of view while maintaining a compact form factor suitable for endoscopy applications. Moreover, the Mueller matrix transform and Mueller matrix polarization decomposition are analyzed for cancerous and healthy tissue samples from the colon, large intestine, and stomach. The results indicate that the proposed method achieves a compact size with a wide field of view while effectively differentiating pathological variations through Mueller matrix analysis.
- 28 November 2025
- Published by Wiley in Laser & Photonics Reviews
- Vol. 20 (7)
Metalens Enabled Compact and Wide‐Angle 3 × 3 Mueller Matrix Polarimetric Imaging for the Advanced Medical Applications
Recent advancements in nanofabrication technology and metalenses have enabled the miniaturization of polarization imaging devices. This study presents a novel polarization‐sensitive metalens design specifically engineered for endoscopy applications, focusing on the early diagnosis of gastrointestinal diseases, particularly cancer. The proposed system integrates three apertures and three distinct metalenses with polarization orientations of 0°, 45°, and 90°, facilitating comprehensive polarization analysis through Stokes parameters and 3 × 3 Mueller matrix imaging. In the conventional systems, 9 sequential images are required to construct a 3 × 3 Mueller matrix. In contrast, the metalens‐integrated system significantly reduces this requirement by capturing only three sequential images. The system achieves a modulation transfer function of 0.2 at 450 lp/mm with a 70° field of view while maintaining a compact form factor suitable for endoscopy applications. Moreover, the Mueller matrix transform and Mueller matrix polarization decomposition are analyzed for cancerous and healthy tissue samples from the colon, large intestine, and stomach. The results indicate that the proposed method achieves a compact size with a wide field of view while effectively differentiating pathological variations through Mueller matrix analysis.
- 29 April 2025
- Published by Optica Publishing Group in Journal of the Optical Society of America B
- Vol. 42 (5) , 1146-1153
End-to-end optimization for a wide-field-of-view metalens with an aperture stop
Metalenses have great application potential to realize ultra-compact wide-field-of-view (WFOV) optics for surveillance cameras, industrial vision, and medical imaging. Due to the relatively low fabrication requirement, metalenses with an aperture stop for WFOV have attracted much interest recently. However, most designs for this structure rely on commercial design software or exclude the optimization of the aperture size. This work proposes a design framework for a metalens with an aperture stop based on an end-to-end optimization for WFOV imaging, which achieves joint optimization of aperture diameter, substrate thickness, and metalens phase distribution. Using this framework, a metalens with an aperture that achieves a FOV of 160° in the mid-infrared region is designed and demonstrated by both theoretical calculation and simulation. This work is expected to provide alternative design options for miniaturized WFOV imaging optical systems.
- 29 April 2025
- Published by Optica Publishing Group in Journal of the Optical Society of America B
- Vol. 42 (5) , 1146-1153
End-to-end optimization for a wide-field-of-view metalens with an aperture stop
Metalenses have great application potential to realize ultra-compact wide-field-of-view (WFOV) optics for surveillance cameras, industrial vision, and medical imaging. Due to the relatively low fabrication requirement, metalenses with an aperture stop for WFOV have attracted much interest recently. However, most designs for this structure rely on commercial design software or exclude the optimization of the aperture size. This work proposes a design framework for a metalens with an aperture stop based on an end-to-end optimization for WFOV imaging, which achieves joint optimization of aperture diameter, substrate thickness, and metalens phase distribution. Using this framework, a metalens with an aperture that achieves a FOV of 160° in the mid-infrared region is designed and demonstrated by both theoretical calculation and simulation. This work is expected to provide alternative design options for miniaturized WFOV imaging optical systems.
- 21 April 2025
- Published by Springer Nature in The European Physical Journal Plus
- Vol. 140 (4) , 1-11
The mechanism between solar cell efficiency and geometry of truncated quantum dots: implications for practical application
- 21 April 2025
- Published by Springer Nature in The European Physical Journal Plus
- Vol. 140 (4) , 1-11
The mechanism between solar cell efficiency and geometry of truncated quantum dots: implications for practical application
- 7 December 2024
- Published by World Scientific Pub Co Pte Ltd in Journal of Nonlinear Optical Physics & Materials
- Vol. 34 (08)
Investigating nonlinear optical properties of pulsed Nd:YAG laser-excited ZnO/Mn/SiO2 nanocomposites at 532nm
A hydrothermal synthesis approach was employed to fabricate ZnO and ZnO/Mn nanoparticles. Subsequently, the Stöber method was utilized to prepare ZnO/SiO2 and ZnO/Mn/SiO2 nanocomposites using the hydrothermally synthesized ZnO and ZnO/Mn nanoparticles. The successful synthesis of bare ZnO and ZnO-based nanocomposites was confirmed through FTIR spectroscopy and X-ray diffraction analysis. Linear optical characterization led to the calculation of band gap energy amounts utilizing Tauc plot approach. The impact of Mn and SiO2 additives on the nonlinear optical parameters of the ZnO/Mn/SiO2 nanocomposites was evaluated through a [ ]-scan setup under pulsed Nd:YAG laser operated at 532[ ]nm wavelength. Experimental [ ]-scan effects revealed that both bare ZnO and ZnO-based nanocomposites exhibited negative nonlinearity, for which the values could be controlled by the incorporation of additives to achieve enhanced third-order nonlinear susceptibility values in the order of [ ][ ]esu. Outcomes demonstrated that while adding of Mn to ZnO host increased the nonlinear optical parameters, the inclusion of SiO2 led to a slight decrease. However, the simultaneous presence of ZnO, Mn, and SiO2 resulted in the highest nonlinear optical response. These findings suggest that ZnO/Mn/SiO2 nanocomposites exhibit a robust nonlinear optical behavior, offering promising prospects as nonlinear media.
- 7 December 2024
- Published by World Scientific Pub Co Pte Ltd in Journal of Nonlinear Optical Physics & Materials
- Vol. 34 (08)
Investigating nonlinear optical properties of pulsed Nd:YAG laser-excited ZnO/Mn/SiO2 nanocomposites at 532nm
A hydrothermal synthesis approach was employed to fabricate ZnO and ZnO/Mn nanoparticles. Subsequently, the Stöber method was utilized to prepare ZnO/SiO2 and ZnO/Mn/SiO2 nanocomposites using the hydrothermally synthesized ZnO and ZnO/Mn nanoparticles. The successful synthesis of bare ZnO and ZnO-based nanocomposites was confirmed through FTIR spectroscopy and X-ray diffraction analysis. Linear optical characterization led to the calculation of band gap energy amounts utilizing Tauc plot approach. The impact of Mn and SiO2 additives on the nonlinear optical parameters of the ZnO/Mn/SiO2 nanocomposites was evaluated through a [ ]-scan setup under pulsed Nd:YAG laser operated at 532[ ]nm wavelength. Experimental [ ]-scan effects revealed that both bare ZnO and ZnO-based nanocomposites exhibited negative nonlinearity, for which the values could be controlled by the incorporation of additives to achieve enhanced third-order nonlinear susceptibility values in the order of [ ][ ]esu. Outcomes demonstrated that while adding of Mn to ZnO host increased the nonlinear optical parameters, the inclusion of SiO2 led to a slight decrease. However, the simultaneous presence of ZnO, Mn, and SiO2 resulted in the highest nonlinear optical response. These findings suggest that ZnO/Mn/SiO2 nanocomposites exhibit a robust nonlinear optical behavior, offering promising prospects as nonlinear media.
- Open Access
- 17 October 2024
- Published by Wiley in Nanophotonics
- Vol. 13 (24) , 4417-4428
Wide FOV metalens for near‐infrared capsule endoscopy: advancing compact medical imaging
This study presents the design, fabrication, and characterization of a wide field‐of‐view (FOV) metalens optimized for capsule endoscopy. The metalens achieved a 165° FOV with a high modulation transfer function (MTF) of 300 lines per millimeter (lp/mm) across the entire FOV, operating in the near‐infrared (NIR) narrow‐bandpass imaging at 940 nm. The performance of the metalens‐based system is evaluated using two bandwidths, 12 nm and 32 nm, showing MTF values of 0.2 and 0.3 at 250 lp/mm, respectively. The metalens‐based system maintains a compact form factor with a total track length of 1.4 mm and a diameter of 1.58 mm. Compared to a traditional 108° FOV endoscope, the nano‐optic capsule endoscope demonstrated superior performance in terms of FOV, contrast, and resolution. This advancement represents a significant step toward enhancing diagnostic capabilities in medical imaging, offering improved performance in a more compact package compared to conventional optics.
- 17 October 2024
- Published by Wiley in Nanophotonics
- Vol. 13 (24) , 4417-4428
Open AccessWide FOV metalens for near‐infrared capsule endoscopy: advancing compact medical imaging
This study presents the design, fabrication, and characterization of a wide field‐of‐view (FOV) metalens optimized for capsule endoscopy. The metalens achieved a 165° FOV with a high modulation transfer function (MTF) of 300 lines per millimeter (lp/mm) across the entire FOV, operating in the near‐infrared (NIR) narrow‐bandpass imaging at 940 nm. The performance of the metalens‐based system is evaluated using two bandwidths, 12 nm and 32 nm, showing MTF values of 0.2 and 0.3 at 250 lp/mm, respectively. The metalens‐based system maintains a compact form factor with a total track length of 1.4 mm and a diameter of 1.58 mm. Compared to a traditional 108° FOV endoscope, the nano‐optic capsule endoscope demonstrated superior performance in terms of FOV, contrast, and resolution. This advancement represents a significant step toward enhancing diagnostic capabilities in medical imaging, offering improved performance in a more compact package compared to conventional optics.
- 12 July 2024
- Published by IOP Publishing in Physica Scripta
- Vol. 99 (8) , 085520
Ultra-broadband and thin switchable multifunctional metamaterial for terahertz wave
An ultra-broadband thin multi-functional and switchable metamaterial is examined in the terahertz (THz) regime. The proposed design achieved high polarization conversion efficiency and can be switched from a polarization converter to an absorber using the phase change transitioning of vanadium dioxide (VO2). The linear polarization conversion is achieved from 6.0 THz to 15.0 THz, achieving a bandwidth of 9.0 THz, and the absorption is realized from 5.0 THz to 16.0 THz with a bandwidth of 11.0 THz. These broadband characteristics were achieved by a simple metamaterial design incorporating a few layers. The relative bandwidth was 85% for the polarization conversion and 105% for the absorption. Moreover, the angular stability of the designed structure is impressive for various incident angles from 0° to 45°. The proposed switchable design has the potential to contribute to the development of tunable polarization rotating devices, on/off switching LPC devices, which have wide application potentials in THz detection, sensing, adaptive optics, and communications.
- 12 July 2024
- Published by IOP Publishing in Physica Scripta
- Vol. 99 (8) , 085520
Ultra-broadband and thin switchable multifunctional metamaterial for terahertz wave
An ultra-broadband thin multi-functional and switchable metamaterial is examined in the terahertz (THz) regime. The proposed design achieved high polarization conversion efficiency and can be switched from a polarization converter to an absorber using the phase change transitioning of vanadium dioxide (VO2). The linear polarization conversion is achieved from 6.0 THz to 15.0 THz, achieving a bandwidth of 9.0 THz, and the absorption is realized from 5.0 THz to 16.0 THz with a bandwidth of 11.0 THz. These broadband characteristics were achieved by a simple metamaterial design incorporating a few layers. The relative bandwidth was 85% for the polarization conversion and 105% for the absorption. Moreover, the angular stability of the designed structure is impressive for various incident angles from 0° to 45°. The proposed switchable design has the potential to contribute to the development of tunable polarization rotating devices, on/off switching LPC devices, which have wide application potentials in THz detection, sensing, adaptive optics, and communications.
- 1 December 2023
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 40 (12) , 2298-2306
Highly robust performance of a compact, wide-angle, nano-optic capsule endoscopy camera
The performance of capsule endoscopy, which plays an important role in noninvasive medical diagnostics, has been limited by aberrations and large optical sizes caused by several traditional lenses. We propose a capsule endoscopy camera based on a metalens that distinguishes it from existing technologies in three aspects. First, the camera achieved a high FOV of 160°, enabling a comprehensive examination of internal organs. Second, we achieved a compact design with an optical diameter of 1.6 mm and a length of 1.4 mm to enhance patient comfort. The attainment of exceptional image quality with an MTF of more than 45% at 300 lp/mm is the third advantage of this camera. The theoretical performance of this innovative approach shows great potential to improve diagnostic capabilities.
- 1 December 2023
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 40 (12) , 2298-2306
Highly robust performance of a compact, wide-angle, nano-optic capsule endoscopy camera
The performance of capsule endoscopy, which plays an important role in noninvasive medical diagnostics, has been limited by aberrations and large optical sizes caused by several traditional lenses. We propose a capsule endoscopy camera based on a metalens that distinguishes it from existing technologies in three aspects. First, the camera achieved a high FOV of 160°, enabling a comprehensive examination of internal organs. Second, we achieved a compact design with an optical diameter of 1.6 mm and a length of 1.4 mm to enhance patient comfort. The attainment of exceptional image quality with an MTF of more than 45% at 300 lp/mm is the third advantage of this camera. The theoretical performance of this innovative approach shows great potential to improve diagnostic capabilities.