Zhenlin Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Zhenlin Chen has a total of 141 co-authors. Here are the top co-authors by number of shared publications:
- Xinge Yu
Department of Biomedical Engineering City University of Hong Kong Hong Kong the People's Republic of China
10 shared publications - Ya Huang
State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Institute of Fiber Materials and Devices, and Laboratory of Advanced Materials, Fudan University, Shanghai, China
6 shared publications - Dong Sun
Department of Biomedical Engineering, City University of Hong Kong, Kowloon, Hong Kong, China
5 shared publications - Jian Li
Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
5 shared publications - Jingkun Zhou
Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
5 shared publications - Kuanming Yao
Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
5 shared publications
Latest Publications
- Open Access
- 31 July 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (31)
A hemispherical latitude-gradient sensor for closed-loop monitoring and management of scoliosis correction
Conservative treatment of scoliosis relies on physiotherapy and bracing, yet both approaches lack tools for quantitative, real-time monitoring of corrective forces. Here, we introduce a hemispherical latitude-gradient (HS-LG) sensor as a previously unknown sensing paradigm for soft, curved-body interfaces, using scoliosis as a clinical exemplar. Leveraging a nonzero Gaussian curvature ( K G ≠ 0 ) geometry, the device acts as a spatiotemporal mechanical filter, converting normal pressure into in-plane tensile forces to overcome shear and stress artifacts limiting conventional sensors. Integrated into a wireless platform, the HS-LG sensor enables immediate visualization of spatiotemporal pressure dynamics during therapy. In physiotherapy, bilateral deployment established the first quantitative, closed-loop Schroth regimen. Real-time visual feedback amplified targeted asymmetric breathing by ∼40% and decoupled nontargeted regional effort, transforming subjective instruction into data-driven neuromuscular internalization. In bracing, embedded sensors mapped pressures during daily activities, uncovering highly dynamic, posture-specific force redistributions, including transient pressure gradient reversals during ambulation, that challenge conventional static orthotic paradigms. Furthermore, age ( r = 0.738 ) and body mass index (BMI; r = 0.733 ) emerged as strong predictors of daily wear compliance in the lumbar cohort, while BMI consistently drove interfacial mechanical loading across both spinal regions (lumbar r = 0.61 ; thoracic r = 0.77 ). Together, these results establish the HS-LG sensor design as a versatile, patient-ready platform that links geometry-driven sensing design to personalized, data-informed scoliosis management, while broadly advancing the development of wearable mechanosensing technologies for soft, curved biological surfaces.
- 31 July 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (31)
Open AccessA hemispherical latitude-gradient sensor for closed-loop monitoring and management of scoliosis correction
Conservative treatment of scoliosis relies on physiotherapy and bracing, yet both approaches lack tools for quantitative, real-time monitoring of corrective forces. Here, we introduce a hemispherical latitude-gradient (HS-LG) sensor as a previously unknown sensing paradigm for soft, curved-body interfaces, using scoliosis as a clinical exemplar. Leveraging a nonzero Gaussian curvature ( K G ≠ 0 ) geometry, the device acts as a spatiotemporal mechanical filter, converting normal pressure into in-plane tensile forces to overcome shear and stress artifacts limiting conventional sensors. Integrated into a wireless platform, the HS-LG sensor enables immediate visualization of spatiotemporal pressure dynamics during therapy. In physiotherapy, bilateral deployment established the first quantitative, closed-loop Schroth regimen. Real-time visual feedback amplified targeted asymmetric breathing by ∼40% and decoupled nontargeted regional effort, transforming subjective instruction into data-driven neuromuscular internalization. In bracing, embedded sensors mapped pressures during daily activities, uncovering highly dynamic, posture-specific force redistributions, including transient pressure gradient reversals during ambulation, that challenge conventional static orthotic paradigms. Furthermore, age ( r = 0.738 ) and body mass index (BMI; r = 0.733 ) emerged as strong predictors of daily wear compliance in the lumbar cohort, while BMI consistently drove interfacial mechanical loading across both spinal regions (lumbar r = 0.61 ; thoracic r = 0.77 ). Together, these results establish the HS-LG sensor design as a versatile, patient-ready platform that links geometry-driven sensing design to personalized, data-informed scoliosis management, while broadly advancing the development of wearable mechanosensing technologies for soft, curved biological surfaces.
- Open Access
- 17 April 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (16) , eaed7673
Drawn-on-skin electronic tattoo as a closed-loop sensing-stimulation system for the muscles
Simultaneous electromyography (EMG) sensing and closed-loop electrical stimulation (ES) could enable interactive muscle training, motor rehabilitation, and kinesthetic feedback. However, current systems often suffer from nonconformal device/skin interfaces, poor wearability, and anatomical variability among users, limiting signal fidelity and stimulation precision. Here, we present a fully wireless, skin-integrated electronic tattoo platform that records high-quality EMG and delivers closed-loop ES through custom drawn-on-skin, conformal electrodes with strong adhesion and high spatial accuracy. The system supports closed-loop muscle interactions across body regions and even between individuals. Machine learning models classify EMG patterns from different hand gestures with >90% accuracy and adapt ES parameters to stimulate specific muscle groups. In a heavy object holding task, users reached the required grip behavior substantially faster than unassisted controls, indicating improved neuromuscular efficiency. This closed-loop framework not only supports personalized muscle control but also supports coordinated activation across multiple sites or users, unlocking possibilities in interactive motor training, remote rehabilitation, and virtual reality environments.
- 17 April 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (16) , eaed7673
Open AccessDrawn-on-skin electronic tattoo as a closed-loop sensing-stimulation system for the muscles
Simultaneous electromyography (EMG) sensing and closed-loop electrical stimulation (ES) could enable interactive muscle training, motor rehabilitation, and kinesthetic feedback. However, current systems often suffer from nonconformal device/skin interfaces, poor wearability, and anatomical variability among users, limiting signal fidelity and stimulation precision. Here, we present a fully wireless, skin-integrated electronic tattoo platform that records high-quality EMG and delivers closed-loop ES through custom drawn-on-skin, conformal electrodes with strong adhesion and high spatial accuracy. The system supports closed-loop muscle interactions across body regions and even between individuals. Machine learning models classify EMG patterns from different hand gestures with >90% accuracy and adapt ES parameters to stimulate specific muscle groups. In a heavy object holding task, users reached the required grip behavior substantially faster than unassisted controls, indicating improved neuromuscular efficiency. This closed-loop framework not only supports personalized muscle control but also supports coordinated activation across multiple sites or users, unlocking possibilities in interactive motor training, remote rehabilitation, and virtual reality environments.
- Open Access
- 18 March 2026
- Published by Wiley in Advanced Science
- Vol. 13 (31) , e24380
Wearable Tailored Passive Radiative Cooling Textile for Flexible Electronic Integration
Textiles are ideal platforms for wearable electronics due to their inherent softness and superior thermophysiological comfort. However, conventional textiles prioritize wearer comfort at the cost of the stringent thermal‐optical demands imposed by embedded electronics, often sacrificing scalability, breathability, electronic integrability, device performance, and user safety. Here, we report a wearable tailored passive radiative cooling textile (WRCT) for seamless integration of flexible electronics. The WRCT was fabricated via a scalable, one‐step, and additive‐free wet‐spinning technique. Hierarchical phase inversion kinetics create microfibers with multiscale porosity and surface nodules, achieving solar reflectance (>95%) and mid‐infrared emissivity (0.96). This single‐material platform satisfies the conflicting requirements of wearing comfort and electronic functionality by providing breathability, flexibility, and passive daytime thermal management. These properties thermally decouple electronics from the skin and keep skin temperature below 41°C even under intense sunlight (500 W/m 2 ) combined with a localized heat load equivalent to a heat flux of approximately 17 kW/m 2 over a 142 mm 2 area, simulating high‐power microcontrollers, conditions that cause low‐temperature burns within minutes on conventional textiles. By converting a commodity polymer into an advanced thermal‐optical regulator through a mature and scalable fiber‐production process, this textile establishes a practical, safe, and manufacturable foundation for reliable, all‐day wearable electronic systems.
- 18 March 2026
- Published by Wiley in Advanced Science
- Vol. 13 (31) , e24380
Open AccessWearable Tailored Passive Radiative Cooling Textile for Flexible Electronic Integration
Textiles are ideal platforms for wearable electronics due to their inherent softness and superior thermophysiological comfort. However, conventional textiles prioritize wearer comfort at the cost of the stringent thermal‐optical demands imposed by embedded electronics, often sacrificing scalability, breathability, electronic integrability, device performance, and user safety. Here, we report a wearable tailored passive radiative cooling textile (WRCT) for seamless integration of flexible electronics. The WRCT was fabricated via a scalable, one‐step, and additive‐free wet‐spinning technique. Hierarchical phase inversion kinetics create microfibers with multiscale porosity and surface nodules, achieving solar reflectance (>95%) and mid‐infrared emissivity (0.96). This single‐material platform satisfies the conflicting requirements of wearing comfort and electronic functionality by providing breathability, flexibility, and passive daytime thermal management. These properties thermally decouple electronics from the skin and keep skin temperature below 41°C even under intense sunlight (500 W/m 2 ) combined with a localized heat load equivalent to a heat flux of approximately 17 kW/m 2 over a 142 mm 2 area, simulating high‐power microcontrollers, conditions that cause low‐temperature burns within minutes on conventional textiles. By converting a commodity polymer into an advanced thermal‐optical regulator through a mature and scalable fiber‐production process, this textile establishes a practical, safe, and manufacturable foundation for reliable, all‐day wearable electronic systems.
- Top Cited Papers
- 15 January 2026
- Published by Springer Nature in Nature Reviews Materials
- Vol. 11 (4) , 266-285
Deformable materials and structures in wearable haptic interfaces
- 15 January 2026
- Published by Springer Nature in Nature Reviews Materials
- Vol. 11 (4) , 266-285
Top Cited PapersDeformable materials and structures in wearable haptic interfaces
- Open Access
- 31 October 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (44) , eady6745
A gastric retentive robotic capsule enables emergency-prepared and responsive oral drug delivery in canine models
Existing oral drug delivery modalities often fall short in medical emergencies due to the absence of readily deployable, internalized drug storage and delivery mechanisms that combine long-term standby with rapid activation. To address this challenge, we develop and validate a gastric retentive robotic capsule capable of autonomously prepositioning multiple drug doses within the stomach upon oral administration. This system maintains quiescence for extended periods while enabling on-demand, remote-triggered drug release within seconds during emergencies. In a canine (beagle) model, we demonstrate safe gastric residence and functionality for at least 10 weeks, including closed-loop emergency drug delivery modulated by external or onboard biometric sensors for unsupervised symptom detection. At the end of its service life, the capsule can be safely excreted on-demand through the administration of an alkaline solution. These findings establish such a system as a paradigm for emergency-prepared and responsive drug delivery, particularly in vulnerable patient populations.
- 31 October 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (44) , eady6745
Open AccessA gastric retentive robotic capsule enables emergency-prepared and responsive oral drug delivery in canine models
Existing oral drug delivery modalities often fall short in medical emergencies due to the absence of readily deployable, internalized drug storage and delivery mechanisms that combine long-term standby with rapid activation. To address this challenge, we develop and validate a gastric retentive robotic capsule capable of autonomously prepositioning multiple drug doses within the stomach upon oral administration. This system maintains quiescence for extended periods while enabling on-demand, remote-triggered drug release within seconds during emergencies. In a canine (beagle) model, we demonstrate safe gastric residence and functionality for at least 10 weeks, including closed-loop emergency drug delivery modulated by external or onboard biometric sensors for unsupervised symptom detection. At the end of its service life, the capsule can be safely excreted on-demand through the administration of an alkaline solution. These findings establish such a system as a paradigm for emergency-prepared and responsive drug delivery, particularly in vulnerable patient populations.
- Top Cited PapersOpen Access
- 1 July 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1) , 1-17
A skin-interfaced three-dimensional closed-loop sensing and therapeutic electronic wound bandage
Chronic wound healing is a complex and long-standing problem, that has been a major and critical clinical concern around the world for years. Recent advances in digital wound dressings open new possibilities for solving the problem. Here, we report a battery-free, fully permeable, skin-adhesive, stretchable electronic wound bandage (iSAFE) for intelligent wound management. This electronic bandage exhibits superior properties in multiple features and can be conformally adhered to the skin wound. In addition, the iSAFE can accurately assess the wound conditions in-situ and thus adaptively perform localized drug release. The results from both in vitro and in vivo studies on animals prove the validity of wound monitoring, wound healing boosting and intelligent closed-loop wound management. Clinical trials on patients across age 18 to 95 with various types of wounds are performed. These results all indicate the unique and universality of the reported technology for wound monitoring and management.
- 1 July 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1) , 1-17
Top Cited PapersOpen AccessA skin-interfaced three-dimensional closed-loop sensing and therapeutic electronic wound bandage
Chronic wound healing is a complex and long-standing problem, that has been a major and critical clinical concern around the world for years. Recent advances in digital wound dressings open new possibilities for solving the problem. Here, we report a battery-free, fully permeable, skin-adhesive, stretchable electronic wound bandage (iSAFE) for intelligent wound management. This electronic bandage exhibits superior properties in multiple features and can be conformally adhered to the skin wound. In addition, the iSAFE can accurately assess the wound conditions in-situ and thus adaptively perform localized drug release. The results from both in vitro and in vivo studies on animals prove the validity of wound monitoring, wound healing boosting and intelligent closed-loop wound management. Clinical trials on patients across age 18 to 95 with various types of wounds are performed. These results all indicate the unique and universality of the reported technology for wound monitoring and management.
- 8 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 10 (8) , 7923-7930
A Modular Magnetic Navigation System for Actuating Surface Microwalkers
The complex motion modes of surface microwalkers rely on magnetic torque generated by rotating/oscillating magnetic fields. Actuation systems based on rotating permanent magnets exhibit considerable advantages in generating these dynamic fields due to their high flexibility. However, current omnidirectional magnet control systems are complex in design, while single-axis rotational control systems are limited to specific motion modes. This study presents a modular magnetic navigation system based on the quasi-omnidirectional magnet control, aiming to balance control complexity and system functionality. This system utilizes a dual-sided layout, with the rotating magnet system and imaging system positioned on opposite sides of the sample module, thereby reducing control complexity for target tracking in a dynamic field of view. The dual-axis rotation control of the magnet is achieved by a decoupled two-degree-of-freedom rotating platform, enabling the switching of multiple rotation fields. Various rotating magnetic fields generated by the proposed system are modeled, and different motion modes of surface microwalkers driven by the system are analyzed. Based on this, corresponding motion control strategies are provided for different motion modes. Finally, experiments are performed to verify the performance of the proposed system in actuating both rolling and swarm motion of surface microwalkers. The results demonstrate that the proposed modular navigation system has comparable actuation capabilities to existing systems, but with lower control complexity, suggesting its potential for designing magnetic actuation systems in clinical applications
- 8 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 10 (8) , 7923-7930
A Modular Magnetic Navigation System for Actuating Surface Microwalkers
The complex motion modes of surface microwalkers rely on magnetic torque generated by rotating/oscillating magnetic fields. Actuation systems based on rotating permanent magnets exhibit considerable advantages in generating these dynamic fields due to their high flexibility. However, current omnidirectional magnet control systems are complex in design, while single-axis rotational control systems are limited to specific motion modes. This study presents a modular magnetic navigation system based on the quasi-omnidirectional magnet control, aiming to balance control complexity and system functionality. This system utilizes a dual-sided layout, with the rotating magnet system and imaging system positioned on opposite sides of the sample module, thereby reducing control complexity for target tracking in a dynamic field of view. The dual-axis rotation control of the magnet is achieved by a decoupled two-degree-of-freedom rotating platform, enabling the switching of multiple rotation fields. Various rotating magnetic fields generated by the proposed system are modeled, and different motion modes of surface microwalkers driven by the system are analyzed. Based on this, corresponding motion control strategies are provided for different motion modes. Finally, experiments are performed to verify the performance of the proposed system in actuating both rolling and swarm motion of surface microwalkers. The results demonstrate that the proposed modular navigation system has comparable actuation capabilities to existing systems, but with lower control complexity, suggesting its potential for designing magnetic actuation systems in clinical applications
- 15 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (8) , 8208-8218
Design and Control of a Modular, Untethered Soft Origami Robot Driven by SMA Coils
Soft robots show advantages in flexibility and safe interaction compared with traditional rigid robots. The modular design of soft robots further improves their reconfigurability and easy maintenance. This article presents a soft modular robot based on a rectangular origami structure, which can achieve untethered, controllable, and diverse motions. The single robot module is designed with actuation by four shape memory alloy coils and attitude perception based on an inertial measurement unit sensor. The module has an option for the use of internal battery or external power, can be wirelessly charged, and can be used as a flexible sensor to sense forced deformation. A model-free controller based on the cross-coupling concept is also proposed to control the attitude angles of the single module, the accuracy and robustness of which are verified by extensive experiments. The strong independence of the origami module in actuation, sense, and control facilitates reconfiguring various robots, such as a crawling robot, a gripper, and a robotic arm, and programming their motions. These robots can be quickly assembled or disassembled by magnetic attachments and will provide solutions for variable work assignments.
- 15 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (8) , 8208-8218
Design and Control of a Modular, Untethered Soft Origami Robot Driven by SMA Coils
Soft robots show advantages in flexibility and safe interaction compared with traditional rigid robots. The modular design of soft robots further improves their reconfigurability and easy maintenance. This article presents a soft modular robot based on a rectangular origami structure, which can achieve untethered, controllable, and diverse motions. The single robot module is designed with actuation by four shape memory alloy coils and attitude perception based on an inertial measurement unit sensor. The module has an option for the use of internal battery or external power, can be wirelessly charged, and can be used as a flexible sensor to sense forced deformation. A model-free controller based on the cross-coupling concept is also proposed to control the attitude angles of the single module, the accuracy and robustness of which are verified by extensive experiments. The strong independence of the origami module in actuation, sense, and control facilitates reconfiguring various robots, such as a crawling robot, a gripper, and a robotic arm, and programming their motions. These robots can be quickly assembled or disassembled by magnetic attachments and will provide solutions for variable work assignments.
- Open Access
- 18 October 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 10 (42)
A fully integrated breathable haptic textile
Wearable haptics serve as an enhanced media to connect humans and VR/robots. The inevitable sweating issue in all wearables creates a bottleneck for wearable haptics, as the sweat/moisture accumulated in the skin/device interface can substantially affect feedback accuracy, comfortability, and create hygienic problems. Nowadays, wearable haptics typically gain performance at the cost of sacrificing the breathability, comfort, and biocompatibility. Here, we developed a fully integrated breathable haptic textile (FIBHT) to solve these trade-off issues, where the FIBHT exhibits high-level integration of 128 pixels over the palm, great stretchability of 400%, and superior permeability of over 657 g/m 2 /day (moisture) and 40 mm/s (air). It is a stand-alone haptic system totally composed of stretchable, breathable, and bioadhesive materials, which empowers it with precise, sweating/movement-insensitive and dynamic feedback, and makes FIBHT powerful for virtual touching in broad scenarios.
- 18 October 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 10 (42)
Open AccessA fully integrated breathable haptic textile
Wearable haptics serve as an enhanced media to connect humans and VR/robots. The inevitable sweating issue in all wearables creates a bottleneck for wearable haptics, as the sweat/moisture accumulated in the skin/device interface can substantially affect feedback accuracy, comfortability, and create hygienic problems. Nowadays, wearable haptics typically gain performance at the cost of sacrificing the breathability, comfort, and biocompatibility. Here, we developed a fully integrated breathable haptic textile (FIBHT) to solve these trade-off issues, where the FIBHT exhibits high-level integration of 128 pixels over the palm, great stretchability of 400%, and superior permeability of over 657 g/m 2 /day (moisture) and 40 mm/s (air). It is a stand-alone haptic system totally composed of stretchable, breathable, and bioadhesive materials, which empowers it with precise, sweating/movement-insensitive and dynamic feedback, and makes FIBHT powerful for virtual touching in broad scenarios.
- Open Access
- 6 September 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-12
Wearable bio-adhesive metal detector array (BioMDA) for spinal implants
Dynamic tracking of spinal instrumentation could facilitate real-time evaluation of hardware integrity and in so doing alert patients/clinicians of potential failure(s). Critically, no method yet exists to continually monitor the integrity of spinal hardware and by proxy the process of spinal arthrodesis; as such hardware failures are often not appreciated until clinical symptoms manifest. Accordingly, herein, we report on the development and engineering of a bio-adhesive metal detector array (BioMDA), a potential wearable solution for real-time, non-invasive positional analyses of osseous implants within the spine. The electromagnetic coupling mechanism and intimate interfacial adhesion enable the precise sensing of the metallic implants position without the use of radiation. The customized decoupling models developed facilitate the precise determination of the horizontal and vertical positions of the implants with incredible levels of accuracy (e.g., <0.5 mm). These data support the potential use of BioMDA in real-time/dynamic postoperative monitoring of spinal implants.
- 6 September 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-12
Open AccessWearable bio-adhesive metal detector array (BioMDA) for spinal implants
Dynamic tracking of spinal instrumentation could facilitate real-time evaluation of hardware integrity and in so doing alert patients/clinicians of potential failure(s). Critically, no method yet exists to continually monitor the integrity of spinal hardware and by proxy the process of spinal arthrodesis; as such hardware failures are often not appreciated until clinical symptoms manifest. Accordingly, herein, we report on the development and engineering of a bio-adhesive metal detector array (BioMDA), a potential wearable solution for real-time, non-invasive positional analyses of osseous implants within the spine. The electromagnetic coupling mechanism and intimate interfacial adhesion enable the precise sensing of the metallic implants position without the use of radiation. The customized decoupling models developed facilitate the precise determination of the horizontal and vertical positions of the implants with incredible levels of accuracy (e.g., <0.5 mm). These data support the potential use of BioMDA in real-time/dynamic postoperative monitoring of spinal implants.