Yu Jia Huo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yu Jia Huo has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Renpu Li
Chongqing University of Posts and Telecommunications
2 shared publications - Dandan Wen
Chongqing University of Posts and Telecommunications
1 shared publication - Dinh Duan Dang
ITMO University
1 shared publication - Igor Konyakhin
Higher School of Engineering and Technology, ITMO University, Saint Petersburg, Russia
1 shared publication - Jia Mei Wang
Chongqing University of Posts and Telecommunications
1 shared publication - Juan Yan
Chongqing University of Posts and Telecommunications
1 shared publication
Latest Publications
- 1 June 2025
- Published by Optica Publishing Group in Journal of Optical Technology
- Vol. 92 (6) , 378-384
A study on the background noise error of autocollimators based on Retinex theory
Subject of study . Autocollimation measurement systems are the main means to realize precision angle measurement, but multifaceted error sources limit the further improvement of autocollimator angle measurement accuracy. The purpose of the work. This paper focuses on a kind of reflection noise induced from the non-working optical structure surface inside the autocollimator. This noise source can lead to errors in the detection of the target image by the image sensor. Method. Combined with the principle of Hough transform image recognition, we propose to utilize the Retinex theory to compensate the reflection noise inside the autocollimator. Main results. It is experimentally verified that this compensation algorithm can effectively suppress the influence of noise on imaging detection, and the measurement accuracy of the autocollimator around the X -axis and Y -axis can be improved from 4.29 ′ ′ and 3.87 ′ ′ to 3.59 ′ ′ and 3.15 ′ ′ . The system measurement stability performance is also improved, about 11.99% and 15.75% in the X -axis and Y -axis directions, as well. Practical significance. Therefore, this algorithmic compensation method can effectively enhance the measurement performance of the autocollimator.
- 1 June 2025
- Published by Optica Publishing Group in Journal of Optical Technology
- Vol. 92 (6) , 378-384
A study on the background noise error of autocollimators based on Retinex theory
Subject of study . Autocollimation measurement systems are the main means to realize precision angle measurement, but multifaceted error sources limit the further improvement of autocollimator angle measurement accuracy. The purpose of the work. This paper focuses on a kind of reflection noise induced from the non-working optical structure surface inside the autocollimator. This noise source can lead to errors in the detection of the target image by the image sensor. Method. Combined with the principle of Hough transform image recognition, we propose to utilize the Retinex theory to compensate the reflection noise inside the autocollimator. Main results. It is experimentally verified that this compensation algorithm can effectively suppress the influence of noise on imaging detection, and the measurement accuracy of the autocollimator around the X -axis and Y -axis can be improved from 4.29 ′ ′ and 3.87 ′ ′ to 3.59 ′ ′ and 3.15 ′ ′ . The system measurement stability performance is also improved, about 11.99% and 15.75% in the X -axis and Y -axis directions, as well. Practical significance. Therefore, this algorithmic compensation method can effectively enhance the measurement performance of the autocollimator.
- 11 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (18) , 21197-21207
Research on Calibration Method of MEMS Gyroscope Mounting Error Based on Large-Range Autocollimator
A calibration and measurement method based on an autocollimator and a manual turntable are proposed to calibrate the mounting error of a three-axis microelectromechanical system (MEMS) gyroscope in a wearable inertial measurement unit (IMU). In this system, with extension of the angle range of the autocollimator to ±9° and setting the mutual orthogonal structure of the two autocollimators, the measurement angle range of the MEMS gyroscope mounting error and the evaluation reference of the three-axis attitude angle data are obtained respectively, and the common data acquisition serial port between the autocollimator camera and the IMU host computer is built. As a result, the acquisition time is synchronized between the two systems. Additionally, the angular rate reading value of the MEMS gyroscope is integrated by time to unify the reading value scale between the calibration system and the MEMS gyroscope. This method is further compared with the traditional precision three-axis angular rate output turntable calibration method, and the accuracy deviation of the MEMS gyroscope mounting error after calibration is less than 0.3%. This method helps facilitate the development of inertial sensing calibration techniques toward traceability, which significantly reduces and simplifies laboratory equipment costs and maintenance requirements.
- 11 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (18) , 21197-21207
Research on Calibration Method of MEMS Gyroscope Mounting Error Based on Large-Range Autocollimator
A calibration and measurement method based on an autocollimator and a manual turntable are proposed to calibrate the mounting error of a three-axis microelectromechanical system (MEMS) gyroscope in a wearable inertial measurement unit (IMU). In this system, with extension of the angle range of the autocollimator to ±9° and setting the mutual orthogonal structure of the two autocollimators, the measurement angle range of the MEMS gyroscope mounting error and the evaluation reference of the three-axis attitude angle data are obtained respectively, and the common data acquisition serial port between the autocollimator camera and the IMU host computer is built. As a result, the acquisition time is synchronized between the two systems. Additionally, the angular rate reading value of the MEMS gyroscope is integrated by time to unify the reading value scale between the calibration system and the MEMS gyroscope. This method is further compared with the traditional precision three-axis angular rate output turntable calibration method, and the accuracy deviation of the MEMS gyroscope mounting error after calibration is less than 0.3%. This method helps facilitate the development of inertial sensing calibration techniques toward traceability, which significantly reduces and simplifies laboratory equipment costs and maintenance requirements.