Gongjun Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Gongjun Yang has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
- Qishu Qu
Key Laboratory of Functional Molecule Design and Interface Process, School of Materials and Chemical Engineering, Anhui Jianzhu University, Hefei 230601, China
5 shared publications Fen Qi
Sanitation & Environment Technology Institute, Soochow University, Suzhou 215021, P.R. China
3 shared publicationsMing Shen
2 shared publicationsPing Liu
College of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou, 225002, PR China
2 shared publicationsXi-Long Qu
College of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou, 225002, PR China
2 shared publicationsXiao-Ya Hu
College of Chemistry and Chemical Engineering, Yangzhou University, Yangzhou, 225002, PR China
2 shared publications
Latest Publications
- 1 January 2019
- Published by China Science Publishing & Media Ltd. in Chinese Journal of Chromatography
- Vol. 37 (1) , 32-39
Determination of 10 perfluorinated carboxylic acid compounds in water by gas chromatography-mass spectrometry coupled with negative chemical ionization
A method was developed for the simultaneous determination of 10 perfluorinated carboxylic acid compounds in water by gas chromatography-mass spectrometry coupled with negative chemical ionization ( GC-NCI-MS). Perfluorinated carboxylic acid compounds were derivatizedby trifluoro-N-methyl-N-(trimethylsilyl) acetamide ( MSTFA) as the trimethylsilyl derivatization reagent. The water sample was purified and enriched through a weak anion exchange solid phase extraction column and analyzed via GC-NCI-MS. The sample pretreatment, derivation and instrument conditions were optimized. The results showed that the linearity of the 10 perfluorinated carboxylic acid compounds was good in the range of 0. 1-10 mg/L with correlation coefficients of 0. 995 6-0.999 3. The limits of detection (LODs) and limits of quantification (LOQs) were 0. 5-1. 5 mu g/L and 1.5-4.5 mu g/L, respectively. The spiked recoveries of the blank samples ranged from 70.2% to 112.6% with the relative standard deviations (RSDs) between 2. 1% and 14.5% (n=6). The method is simple, sensitive, accurate and precise, and can be used to detect the 10 perfluorinated carboxylic acid compounds in water.
- 1 January 2019
- Published by China Science Publishing & Media Ltd. in Chinese Journal of Chromatography
- Vol. 37 (1) , 32-39
Determination of 10 perfluorinated carboxylic acid compounds in water by gas chromatography-mass spectrometry coupled with negative chemical ionization
A method was developed for the simultaneous determination of 10 perfluorinated carboxylic acid compounds in water by gas chromatography-mass spectrometry coupled with negative chemical ionization ( GC-NCI-MS). Perfluorinated carboxylic acid compounds were derivatizedby trifluoro-N-methyl-N-(trimethylsilyl) acetamide ( MSTFA) as the trimethylsilyl derivatization reagent. The water sample was purified and enriched through a weak anion exchange solid phase extraction column and analyzed via GC-NCI-MS. The sample pretreatment, derivation and instrument conditions were optimized. The results showed that the linearity of the 10 perfluorinated carboxylic acid compounds was good in the range of 0. 1-10 mg/L with correlation coefficients of 0. 995 6-0.999 3. The limits of detection (LODs) and limits of quantification (LOQs) were 0. 5-1. 5 mu g/L and 1.5-4.5 mu g/L, respectively. The spiked recoveries of the blank samples ranged from 70.2% to 112.6% with the relative standard deviations (RSDs) between 2. 1% and 14.5% (n=6). The method is simple, sensitive, accurate and precise, and can be used to detect the 10 perfluorinated carboxylic acid compounds in water.
- 11 September 2013
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 94 (6) , 546-561
Mechanism of electrochemically polymerised acid chrome blue K and its application in copper ion detection
The possible mechanism of electrochemically polymerised acid chrome blue K (poly(ACBK)) was first investigated by in-situ electron spin resonance (ESR) spectroelectrochemistry, attenuated total reflection (ATR)-FTIR spectroscopy, theoretical calculation and electrochemical method in detail. Then an anodic stripping voltammetric method for the determination of copper was established by using a glassy carbon electrode modified with poly(ACBK) (poly(ACBK)/GCE). After an accumulation time of 100 s at −0.45 V (vs SCE), a linear response for Cu2+ was obtained in the range from 2.0 × 10−8–1.0 × 10−5 molL−1 with the detection limit of 7.0 × 10−9 molL−1 (S/N = 3). Finally, this proposed electrochemical method was successfully applied to determine the copper contents in water and food samples with satisfactory results.
- 11 September 2013
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 94 (6) , 546-561
Mechanism of electrochemically polymerised acid chrome blue K and its application in copper ion detection
The possible mechanism of electrochemically polymerised acid chrome blue K (poly(ACBK)) was first investigated by in-situ electron spin resonance (ESR) spectroelectrochemistry, attenuated total reflection (ATR)-FTIR spectroscopy, theoretical calculation and electrochemical method in detail. Then an anodic stripping voltammetric method for the determination of copper was established by using a glassy carbon electrode modified with poly(ACBK) (poly(ACBK)/GCE). After an accumulation time of 100 s at −0.45 V (vs SCE), a linear response for Cu2+ was obtained in the range from 2.0 × 10−8–1.0 × 10−5 molL−1 with the detection limit of 7.0 × 10−9 molL−1 (S/N = 3). Finally, this proposed electrochemical method was successfully applied to determine the copper contents in water and food samples with satisfactory results.
- 12 August 2013
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 5 (20) , 5684-5693
A novel impedimetric immunosensor for the detection of chicken interferon-gamma based on a polythionine and gold nanoparticle modified glassy carbon electrode
Currently, there is no effective detection method for chicken interferon-γ (ChIFN-γ), therefore it is of great significance to develop a new, accurate and sensitive method for the rapid detection of ChIFN-γ to solve the problems which are directly impeding the in-depth research of immune regulatory factors and poultry immune responses, and which are preventing the analysis and evaluation of the immunity of poultry in diseases or after vaccination. This paper is the first report of a novel label-free electrochemical impedimetric immunosensor for the sensitive detection of ChIFN-γ, based on a 3E3 monoclonal antibody against chicken interferon-γ (denoted as 3E3McAb) immobilized on a glassy carbon electrode modified with polythionine and gold nanoparticle self-assembled layers. The surface modification steps were characterized by scanning electron microscopy and electrochemical impedance spectroscopy (EIS). Detection was performed by measuring the relative change in impedance before and after the 3E3McAb–ChIFN-γ reaction by EIS. Under the optimized conditions, the relative change in impedance was proportional to the logarithmic value of ChIFN-γ concentrations in the range of 0.10 to 1.0 × 103 ng mL−1 (r = 0.9946) with a detection limit of 0.10 ng mL−1. Compared to the traditional method of enzyme-linked immunosorbent assay, the proposed method performed a low-cost, sensitive, quantitative detection of ChIFN-γ in real samples with satisfactory results, indicating that the developed immunoassay could be a promising alternative approach for the detection of ChIFN-γ.
- 12 August 2013
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 5 (20) , 5684-5693
A novel impedimetric immunosensor for the detection of chicken interferon-gamma based on a polythionine and gold nanoparticle modified glassy carbon electrode
Currently, there is no effective detection method for chicken interferon-γ (ChIFN-γ), therefore it is of great significance to develop a new, accurate and sensitive method for the rapid detection of ChIFN-γ to solve the problems which are directly impeding the in-depth research of immune regulatory factors and poultry immune responses, and which are preventing the analysis and evaluation of the immunity of poultry in diseases or after vaccination. This paper is the first report of a novel label-free electrochemical impedimetric immunosensor for the sensitive detection of ChIFN-γ, based on a 3E3 monoclonal antibody against chicken interferon-γ (denoted as 3E3McAb) immobilized on a glassy carbon electrode modified with polythionine and gold nanoparticle self-assembled layers. The surface modification steps were characterized by scanning electron microscopy and electrochemical impedance spectroscopy (EIS). Detection was performed by measuring the relative change in impedance before and after the 3E3McAb–ChIFN-γ reaction by EIS. Under the optimized conditions, the relative change in impedance was proportional to the logarithmic value of ChIFN-γ concentrations in the range of 0.10 to 1.0 × 103 ng mL−1 (r = 0.9946) with a detection limit of 0.10 ng mL−1. Compared to the traditional method of enzyme-linked immunosorbent assay, the proposed method performed a low-cost, sensitive, quantitative detection of ChIFN-γ in real samples with satisfactory results, indicating that the developed immunoassay could be a promising alternative approach for the detection of ChIFN-γ.
- 3 March 2012
- Published by Springer Nature in Microchimica Acta
- Vol. 177 (3-4) , 365-372
Differential pulse anodic stripping voltammetric determination of traces of tin using a glassy carbon electrode modified with bismuth and a film of poly(bromophenol blue)
- 3 March 2012
- Published by Springer Nature in Microchimica Acta
- Vol. 177 (3-4) , 365-372
Differential pulse anodic stripping voltammetric determination of traces of tin using a glassy carbon electrode modified with bismuth and a film of poly(bromophenol blue)
- 1 November 2011
- Published by Elsevier in Analytica Chimica Acta
- Vol. 706 (1) , 120-127
Development of an impedimetric immunosensor for the determination of 3-amino-2-oxazolidone residue in food samples
- 1 November 2011
- Published by Elsevier in Analytica Chimica Acta
- Vol. 706 (1) , 120-127
Development of an impedimetric immunosensor for the determination of 3-amino-2-oxazolidone residue in food samples
- 2 September 2010
- Published by Wiley in Electroanalysis
- Vol. 22 (22) , 2729-2738
High Sensitivity and Reproducibility of a Bismuth/Poly(bromocresol purple) Film Modified Glassy Carbon Electrode for Determination of Trace Amount of Cadmium by Differential Pulse Anodic Stripping Voltammetry
This work described a novel type of bismuth/poly(bromocresol purple) film modified glassy carbon electrode (denoted as Bi/Poly(BCP)/GCE) for anodic stripping analysis of trace Cd2+. The Bi/Poly(BCP)/GCE was fabricated in situ by depositing simultaneously bismuth and cadmium by reduction at −1.20 V on the poly(BCP) film using a differential pulse voltammetry. Under the optimum conditions, the anodic stripping peak current response increased linearly with the Cd2+ concentrations in a range of 2.0×10−8–1.0×10−7 M and 1.0×10−7–6.0×10−6 M in 0.1 M NaAc‐HAc buffer solution (pH 5.0) with the detection limit of 6.5×10−9 M (S/N=3). The Bi/poly(BCP)/GCE performed good reproducibility and high sensitivity. Finally, this proposed method was successfully applied to determine the concentration of Cd2+ in water samples.
- 2 September 2010
- Published by Wiley in Electroanalysis
- Vol. 22 (22) , 2729-2738
High Sensitivity and Reproducibility of a Bismuth/Poly(bromocresol purple) Film Modified Glassy Carbon Electrode for Determination of Trace Amount of Cadmium by Differential Pulse Anodic Stripping Voltammetry
This work described a novel type of bismuth/poly(bromocresol purple) film modified glassy carbon electrode (denoted as Bi/Poly(BCP)/GCE) for anodic stripping analysis of trace Cd2+. The Bi/Poly(BCP)/GCE was fabricated in situ by depositing simultaneously bismuth and cadmium by reduction at −1.20 V on the poly(BCP) film using a differential pulse voltammetry. Under the optimum conditions, the anodic stripping peak current response increased linearly with the Cd2+ concentrations in a range of 2.0×10−8–1.0×10−7 M and 1.0×10−7–6.0×10−6 M in 0.1 M NaAc‐HAc buffer solution (pH 5.0) with the detection limit of 6.5×10−9 M (S/N=3). The Bi/poly(BCP)/GCE performed good reproducibility and high sensitivity. Finally, this proposed method was successfully applied to determine the concentration of Cd2+ in water samples.
- 1 August 2009
- Published by Elsevier in Analytica Chimica Acta
- Vol. 647 (2) , 159-166
A reusable capacitive immunosensor for detection of Salmonella spp. based on grafted ethylene diamine and self-assembled gold nanoparticle monolayers
- 1 August 2009
- Published by Elsevier in Analytica Chimica Acta
- Vol. 647 (2) , 159-166
A reusable capacitive immunosensor for detection of Salmonella spp. based on grafted ethylene diamine and self-assembled gold nanoparticle monolayers
- 1 June 2008
- Published by Elsevier in Bioelectrochemistry
- Vol. 73 (1) , 37-42
Poly(amidosulfonic acid) modified glassy carbon electrode for determination of isoniazid in pharmaceuticals
- 1 June 2008
- Published by Elsevier in Bioelectrochemistry
- Vol. 73 (1) , 37-42
Poly(amidosulfonic acid) modified glassy carbon electrode for determination of isoniazid in pharmaceuticals
- 10 December 2007
- Published by Springer Nature in Microchimica Acta
- Vol. 160 (1) , 275-281
Electrochemical behavior of lead(II) at poly(phenol red) modified glassy carbon electrode, and its trace determination by differential pulse anodic stripping voltammetry
- 10 December 2007
- Published by Springer Nature in Microchimica Acta
- Vol. 160 (1) , 275-281
Electrochemical behavior of lead(II) at poly(phenol red) modified glassy carbon electrode, and its trace determination by differential pulse anodic stripping voltammetry