NPN. Yu. Peretyagin

N. Yu. Peretyagin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


N. Yu. Peretyagin has a total of 33 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Evaluation of the morphology of fillers of modern dental nanocomposite materials

    by N. I. Krikheli, P. Yu. Peretyagin, M. N. Bychkova, E. Yu. Mendoza, O. V. Rudneva, N. Yu. Peretyagin, S. R. Shekhtman, E. V. Kuznetsova, A. Yu. Kurmysheva, Е. Ю. Мендоса, et al.

    In the course of the research work, the morphological characteristics of the inorganic filler of five commercial and one experimental dental restorative composite materials containing nanosized particles were assessed using a Tescan Vega 3 LMH scanning electron microscope (Tescan, Brno, Czech Republic). Scanning electron microscopy revealed that the studied samples of imported paste-like composite materials contained fillers similar in shape and size: prepolarized conglomerates of irregular shapes ranging from 3 to 40 µm, consisting of nanoscale spheres less than 200 nm in size, and individual spherical particles up to 200 nm in size. The prepolarized filler in the low-modulus (flowable) imported composite had  a smaller diameter of 3 to 30 µm and a more regular spherical shape. The fillers in the Russian-produced composite materials had fragmented particles, with some of the filler consisting of micron-sized clusters ranging from 5 to 30 µm, formed by nanoscale spherical particles less than 100 nm in size. The experimental composite material contained microspheres ranging in size from 5 to 20 µm, consisting of nanoscale spherical particles up to 450 nm in size. In terms of morphological structure, the experimental composite is comparable to fillers of modern imported commercial dental composite materials.


  • Open Access

    Comparative biomechanical analysis and prospects for additive manufacturing of dental implants from zirconium oxide and titanium

    by N. I. Krikheli, P. Yu. Peretyagin, A. M. Tsitsiashvili, E. V. Pustovoit, M. S. Nozdrina, O. V. Rudneva, N. V. Khodanovich, N. Yu. Peretyagin, Yu. I. Zhukovskaya, A. A. Mozhaev, et al.

    This paper presents a comprehensive analysis of zirconium oxide dental implants, including biomechanical modeling and an assessment of the potential for additive manufacturing. The aim of the study was to validate the effectiveness of stereolithography for creating zirconium implants with complex geometries and compare their biomechanical behavior with their titanium counterparts. In the first stage, a finite element analysis (FEA) was performed in Ansys Mechanical. A 3D model of the crown-abutment-implant system integrated into cortical and cancellous bone (considered an orthotropic material) was used for the simulation. A static load of 250 N was applied to the titanium and zirconium models in five vector configurations. The results of the von Mises equivalent stress calculations showed that zirconium implants are characterized by a higher stress concentration within the body of the implant, but provide lower load transfer to the surrounding bone tissue compared to titanium implants, especially under oblique impact, which is beneficial for bone preservation. In the second stage, a prototype implant (Straumann BLT NC 8 mm) was manufactured using layer-by-layer stereolithography (SLA) from zirconia partially stabilized with yttria. This technology allowed for the production of highly precise, thin-walled components with complex profiles, free of internal defects (cracks and pores), and with minimal waste. After sintering at 1400–1550°C, the resulting samples demonstrated flexural strengths of approximately 1000 MPa and compressive strengths of 2070 MPa. The study results confirm that the combination of high strength properties of additively bonded zirconia and favorable load distribution on bone tissue opens up broad possibilities for the personalized use of ceramic implants in clinical dentistry.


  • Development of a technology for manufacturing nanostructured ceramic CAD/CAM blanks for dentistry

    by O. O. Yanushevich, N. I. Krikheli, P. Yu. Peretyagin, I. V. Klizhov, A. T. Sampiev, O. V. Kramar, N. Yu. Peretyagin, A. A. Shein

    Technical innovation plays a key role in modern life, and it is precisely this innovation that has driven the development of digital technologies in dentistry. In the 1980s, CAD/CAM systems emerged in dental practice. These systems reduced manual workload and offered such qualities as precision, ergonomics, cleanliness, versatility, and high productivity. These systems became extremely popular among doctors and patients, ushering in a new era of dental care. The significant popularity of CAD/CAM technologies in dentistry and their demand served as the basis for the development of a domestic technology for the production of nanostructured ceramic CAD/CAM blanks for dentistry. In the previous phase of the study, the influence of spray drying parameters on the characteristics of the resulting powders was studied, and various powder sintering methods, such as free-flow and spark plasma sintering (SPS), were analyzed to achieve ideal density, mechanical strength, and crack resistance [7]. As part of the current stage of work, it is planned to manufacture experimental samples of CAD/CAM blanks from ceramic composites based on zirconium dioxide.

  • A comparative review of the physical and chemical characteristics of titanium and zirconium dioxide used for the production of dental implants

    by О. О. Yanushevich, N. I. Krikheli, P. Yu. Peretyagin, A. M. Tsitsiashvili, O. V. Kramar, N. Yu. Peretyagin, P. A. Naumenko, M. N. Bychkova, E. V. Kuznetsova, N. V. Solis Pinargote

    Taking into account the continuing search for the optimal material for the production of dental implants, it seems relevant to compare, according to the literature, the physico-chemical properties (mechanical properties, osseointegration ability, fatigue endurance of titanium (cpTi grade 1-4, Ti-6Al-4V) and yttrium-stabilized zirconium dioxide (ZrO 2 ) used for the production of dental implants. The analysis of published experimental clinical papers (in vitro, in vivo), studies using simulations based on the finite element method. The review shows a comparable ability to osseointegration in both materials, zirconium dioxide demonstrates a higher modulus of elasticity and hardness, but increased sensitivity to fatigue. Titanium retains the advantage of plasticity and proven long-term operation. Thus, titanium remains the most versatile and predictable material, while zirconium implants are a real and promising alternative for a number of clinical cases.


  • Modern methods of post-endodontic dental treatment

    by N. I. Krikheli, E. V. Pustovoit, M. S. Nozdrina, O. V. Kramar, P. Yu. Peretyagin, N. Yu. Peretyagin, Н. Ю. Перетягин

    The materials used to restore the crown part of teeth after endodontic treatment in modern conditions are presented. The advantages of post-endodontic dental treatment using a variety of pin structures in the system of providing dental care to the population are shown. The relevance of the search and development of new domestic materials for intra-channel pins with improved properties is shown in the program that promotes import substitution in dentistry, thereby solving one of the main strategic components in improving the quality of life of the patient.


  • Application of light-cured nanofilled composite materials in dentistry (literature review)

    by N. I. Krikheli, M. N. Bychkova, O. V. Kramar, O. V. Rudneva, P. Yu. Peretyagin, N. Yu. Peretyagin, Н. Ю. Перетяги

    Currently, patients are increasingly turning to dentists with complaints about unsatisfactory dental aesthetics. All this is associated with both carious and non-carious lesions of the teeth. Methods of dental treatment today are diverse and satisfy the desires of even the most fastidious patient. So, in the treatment of dental caries, dentists prefer filling. All kinds of composite materials, mainly of foreign production, are used for sealing. Due to the changed global trends, we are faced with the task of finding and developing a new domestic nanofilled light-curing composite that will not be inferior in its properties and composition to leading foreign analogues.


  • CAD/CAM technologies and their place in modern dentistry

    by O.O. Yanushevich, N.I. Krikheli, P.YU. Peretyagin, O.V. Kramar, N.YU. Peretyagin, I.V. Klizhov, N.G. Undritsova

    Digital technologies are undoubtedly associated with technical innovations and today occupy and important place in modern dentistry. According to Russian and foreign publications’ data, foreign developments in this area have been started more than 50 years ago, and in Russia their greatest spread was more than 10 years ago. Currently, there are various types of dental ceramics for CAD/CAM, thus an important task is to develop new technologies for mixing powders without the formation of agglomerates.


  • Open Access

    Electrochemical deposition of ceramic-like coatings on Ti-6Al-4V parts fabricated by electron beam melting

    by N Y Peretyagin, I V Suminov, A Smirnov, N I Krikheli, O V Kramar, P Y Peretyagin

    The problems of micro-arc oxidation of titanium alloy parts Ti-6Al-4V produced by electron beam melting technology were considered. The phase composition, thickness and roughnessof the obtained coating have been evaluated.