BJBree Jones

Bree Jones

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Bree Jones has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Digital Scribes in Dentistry: Opportunities, Risks and Practical Considerations

    by Bree Jones, Andrew Gikas, Tami Yap, Rishi Ramani

    Digital scribes are increasingly being adopted in healthcare to reduce documentation burden and improve clinical workflow. These systems generate clinical records from clinician–patient conversations using speech recognition and artificial intelligence (AI) technologies. While studies in medicine suggest benefits including reduced administrative workload and improved clinician experience, evidence in dentistry remains limited. This narrative review examines the current evidence, challenges, and implementation considerations associated with digital scribes in Australian dental practice. Potential benefits include improved workflow efficiency, documentation support, clinician satisfaction and enhanced practitioner–patient relationships. Reported limitations include omissions, factual inaccuracies, poor recognition of dental terminology, reduced performance in complex communication environments and the generation of misleading or excessive clinical records. Potential unintended consequences include automation bias, changes in clinician–patient interactions, impacts on clinical reasoning, patient self‐censorship, and equity concerns related to algorithmic bias. Dental practitioners remain professionally accountable for the accuracy and completeness of AI‐generated clinical records. Consequently, implementation of digital scribes in dental settings requires robust governance, informed consent processes, clinician oversight and ongoing performance auditing. Further research is needed to evaluate the impact of digital scribes in dental practice, including their effects on patient outcomes, dental education and health equity.

  • Is AI Qualified to Give Dental Advice?

    by Rishi Ramani, Bree Jones, Arosha Weerakoon, Tami Yap

  • Open Access

    Navigating the Regulatory Landscape of Artificial Intelligence in A ustralian Clinical Dentistry

    by Rishi Ramani, Arosha Weerakoon, Tami Yap, Bree Jones

    Artificial intelligence (AI) is rapidly transforming clinical dentistry, with an increasing number of AI‐powered diagnostic and treatment planning tools entering the Australian healthcare market. As clinicians adopt AI‐based dental software, it is becoming increasingly important to understand the regulatory frameworks that govern them. This narrative review explores the regulatory approval pathways and governance of AI tools used in Australian dental and healthcare settings to inform and educate practitioners. Australia regulates AI‐based dental software primarily through the Therapeutic Goods Administration, which classifies eligible products as software as a medical device under a risk‐based, technology‐agnostic framework established by the Therapeutic Goods Act 1989. AI tools that function as clinical decision‐support systems are subject to mandatory conformity assessment and registration on the Australian Register of Therapeutic Goods (ARTG) prior to lawful supply. Although the Australian framework aligns with the International Medical Device Regulators Forum principles, the approval process is comparatively less transparent than that required in jurisdictions such as the United States and the European Union, and questions remain regarding the consistency of post‐market oversight. This review also highlights emerging regulatory challenges associated with adaptive AI systems. Software could initially receive approval as a low‐risk device that evolves to provide specific clinical advice beyond its approval scope. These updates to functionality risk bypassing established oversight pathways that rely on self‐reported intended use. Furthermore, currently available AI tools lack comprehensive public‐facing transparent evidence for regulatory compliance that is complicated by ambiguous and inconsistent terminology and adaptive AI system classification. Regardless of regulatory approval, clinicians remain professionally accountable for the use of AI tools in clinical decision‐making and for ensuring that patient care meets accepted standards of practice.


  • Open Access

    Artificial Intelligence in Intraoral Scanning: A Narrative Review

    by Camila Tirapelli, Bree Jones, Caio Uehara Martins, Bruna Neves de Freitas, Alessandra Alaniz Macedo, Ruben Pauwels

    Intraoral scanning (IOS) enables the acquisition of three‐dimensional surface models of dental and oral structures, supporting diagnosis, treatment planning and digital workflows. However, many processing steps remain operator‐dependent and time‐consuming. The integration of artificial intelligence (AI) with intraoral scanning (IOS) represents a rapidly evolving area in digital dentistry, aiming to automate or facilitate tasks such as tooth segmentation, landmark detection, registration and quality control. This narrative review aims to summarise technical principles, current applications, challenges, and opportunities associated with AI applied to IOS data. A narrative approach was adopted to identify and describe recent studies involving AI applications using IOS datasets. Current evidence demonstrates that automated tooth segmentation is the most developed application, with emerging uses in orthodontics, prosthodontics, surgery, and diagnostics. Despite promising performance, challenges persist, including limited dataset availability, variability across scanning systems, annotation complexity, computational demands, and reduced generalisability. Future research should prioritise standardised datasets, external validation, and clinically meaningful outcomes to support safe and effective implementation.


  • Open Access

    Dental Caries Detection in Children Using Intraoral Scanners Featuring Fluorescence: Diagnostic Agreement Study

    by Bree Jones, Tong Chen, Stavroula Michou, Nicky Kilpatrick, Nigel Curtis, David P Burgner, Christoph Vannahme, Mihiri Silva

    Background: Dental caries is a common chronic disease in children. Digital tools such as intraoral scanners (IOSs) may offer an efficient, scalable alternative to conventional visual examination for dental caries detection. IOSs are handheld devices that generate 3-dimensional (3D) models of the teeth and surrounding structures. Recent advances incorporating fluorescence technology into scanner hardware offer the potential for supporting dental caries detection. However, the performance of digital caries detection methods using 3D models that include both color and fluorescence in children’s teeth remains unknown. Objective: This study aimed to assess the diagnostic agreement between visual examination and on-screen assessment of 3D models generated by an IOS in color and supplemented with fluorescence for caries detection in primary teeth. Methods: Children participating in a clinical trial (n=216, mean age 5.6, SD 0.4 y) underwent visual examination using the International Caries Detection and Assessment System (ICDAS) and intraoral scanning using the TRIOS 4 IOS. Four trained registered dental practitioners independently assessed each participant’s 3D models in color and then supplemented with fluorescence, using a previously validated ICDAS index modified for on-screen assessments of 3D models. All 3D models were assessed again after 4 weeks. The time taken for intraoral scanning and on-screen assessment was recorded. Multilevel logistic regression was used to estimate and compare the likelihood of detecting caries between methods, and Bland-Altman plots were used to visualize agreement. Analyses were performed at the initial (ICDAS ≥ 01), moderate (ICDAS ≥03), and extensive (ICDAS ≥05) dental caries thresholds. Intraclass correlation coefficient (ICC) estimated method agreement and examiner reliability. Results: Of 219 children enrolled, 216 completed dental assessments. A total of 9470 visible primary tooth surfaces were included in the analysis. The average time taken for on-screen assessment of each 3D model (color with fluorescence) was 3.5 (SD 2.3) minutes. The likelihood of detecting caries using color assessment of 3D models was similar to visual examination at all disease thresholds: initial (odds ratio [OR] 1.1, 95% CI 1.0‐1.3), moderate (OR 0.9, 95% CI 0.7‐1.1), and extensive (OR 1.0, 95% CI 0.7‐1.3). When color assessments were supplemented with fluorescence, the likelihood of detecting caries was 30% higher at the initial threshold relative to visual examination (OR 1.3, 95% CI 1.1‐1.5) and similar at the moderate (OR 0.9, 95% CI 0.7‐1.1) and extensive thresholds (OR 0.9, 95% CI 0.7‐1.3). Bland-Altman plots showed a high level of agreement at both moderate and extensive thresholds. Agreement between methods was high (ICC 0.9, 95% CI 0.9‐1.0). Intra- and inter-examiner reliability using intraoral scans ranged from good to excellent (ICC 0.8‐1.0). Conclusions: On-screen assessment of 3D models in color demonstrated the highest agreement with visual examination for caries detection across all disease thresholds.


  • Top Cited Papers
    Open Access

    Dental caries detection in children using intraoral scans and deep learning

    by Bree Jones, Mathias Lambach, Tong Chen, Stavroula Michou, Nicky Kilpatrick, Nigel Curtis, David P. Burgner, Christoph Vannahme, Mihiri Silva


  • Open Access

    Artificial Intelligence Chatbots as Virtual Patients in Dental Education: A Constructivist Approach to Classroom Implementation

    by Bree Jones, Aditya Desu, Christopher D. F. Honig

    Introduction: Advances in artificial intelligence (AI) have led to new possibilities for AI role‐play in classroom settings, where generative pre‐trained transformers (GPTs) and chatbots can potentially simulate interactions with patients. This pilot study aimed to design an AI role‐play activity underpinned by constructivist principles, implement the activity in a classroom setting, and evaluate the students' engagement with the activity and usability of the interface. Materials and Methods: The AI role‐play was designed based on a patient presenting to a dental teaching hospital in pain. It comprised two interconnected chatbots intended to simulate a patient consultation and clinical supervisor discussion. The chatbots were built using the open‐source framework Streamlit and powered by Chat GPT‐4. Second and final‐year students from an oral health degree were recruited through convenience sampling. Classroom observations were recorded and final‐year students participated in a usability questionnaire to gain insights into their engagement, technical challenges, and suggestions for improvement. Data usage and token costs were collected to assess the AI chatbot's feasibility. Results: Educator observations noted that AI role‐play facilitated peer discussion, highlighted gaps in history‐taking, and promoted peer learning. Usability survey feedback ( n = 14) suggested that students perceived the AI role‐play as authentic and relevant to clinical practice, with 86% strongly agreeing it aligned with real‐world dental scenarios. The screen design, navigation, and multimedia integration were highly rated. The approximate costs for the activities were $13.17 (USD) for approximately 20 queries, per 20 students. Conclusion: This study presents a descriptive analysis of the implementation of an AI role‐play within the early phases of a design‐based research framework. AI role‐play activities can be implemented in a classroom setting and are perceived as useful for students to apply skills in taking a pain history. While results showed promise for scalability and authentic learning, future research evaluating the impact of the implementation of these activities on student learning should be explored.


  • Open Access

    Digital Caries Detection in Children using Intraoral Scanners: A Diagnostic Agreement Study (Preprint)

    by Bree Jones, Tong Chen, Stavroula Michou, Nicky Kilpatrick, Nigel Curtis, David P Burgner, Christoph Vannahme, Mihiri Silva

    BACKGROUND Dental caries is a common chronic disease in children, yet large-scale surveillance is limited by the resource demands of clinical examinations. Digital tools like intraoral scanners may offer a scalable alternative for caries detection, enabling more efficient data collection for research and population-level oral health monitoring. OBJECTIVE To assess the diagnostic agreement between visual examination and on-screen assessment of 3D models generated by an intraoral scanner (IOS) in colour and supplemented with fluorescence for caries detection in primary teeth. METHODS Children participating in a clinical trial (n=216, mean age 5.6 years) underwent visual examination using the International Caries Detection and Assessment System (ICDAS) and intraoral scanning using the TRIOS 4 IOS (3Shape TRIOS A/S Denmark). Four trained registered dental practitioners independently assessed each participant’s 3D models in colour, then supplemented with fluorescence, using a previously validated ICDAS index modified for on-screen assessments of 3D models. All 3D models were assessed again four weeks later. The time taken for intraoral scanning and on-screen assessment was recorded. Multilevel logistic regression was used to estimate and compare the likelihood of detecting caries between methods, and Bland–Altman plots were used to visualise agreement. Analyses were performed at the initial (ICDAS>01), moderate (ICDAS>03), and extensive (ICDAS>05) dental caries thresholds. Intraclass Correlation Coefficient (ICC) estimated method agreement and examiner reliability. RESULTS 8,209 visible primary tooth coronal surfaces were analysed. The likelihood of detecting caries using colour assessment of 3D models was similar to visual examination at all disease thresholds: initial (odds ratio 1.1, 95% confidence interval (CI) 1.0–1.3), moderate (0.9, 0.7-1.1) and extensive (1.0, 0.7–1.3). When colour assessments were supplemented with fluorescence, the likelihood of detecting caries was 30% higher at the initial threshold relative to visual examination (1.3, 1.1-1.5) and similar at the moderate (0.9, 0.7-1.1) and extensive thresholds (0.9, 0.7-1.3). Bland-Altman plots showed a high level of agreement at both moderate and extensive thresholds. Examiner reliability using intraoral scans ranged from good to excellent. CONCLUSIONS On-screen assessment of 3D models in colour shows greatest agreement with visual examination for caries detection at all disease thresholds. CLINICALTRIAL Australian New Zealand Clinical Trials Registry ACTRN12622001237774 INTERNATIONAL REGISTERED REPORT RR2-10.2196/51578

  • Open Access

    Diagnostic agreement between visual examination and an automated scanner system with fluorescence for detecting and classifying occlusal carious lesions in primary teeth

    by Bree Jones, Tong Chen, Stavroula Michou, Nicky Kilpatrick, David P. Burgner, Christoph Vannahme, Mihiri Silva


  • Open Access

    Caries Detection in Primary Teeth Using Intraoral Scanners Featuring Fluorescence: Protocol for a Diagnostic Agreement Study

    by Bree Jones, Stavroula Michou, Tong Chen, Margarita Moreno-Betancur, Nicky Kilpatrick, David Burgner, Christoph Vannahme, Mihiri Silva

    Background: Digital methods that enable early caries identification can streamline data collection in research and optimize dental examinations for young children. Intraoral scanners are devices used for creating 3D models of teeth in dentistry and are being rapidly adopted into clinical workflows. Integrating fluorescence technology into scanner hardware can support early caries detection. However, the performance of caries detection methods using 3D models featuring color and fluorescence in primary teeth is unknown. Objective: This study aims to assess the diagnostic agreement between visual examination (VE), on-screen assessment of 3D models in approximate natural colors with and without fluorescence, and application of an automated caries scoring system to the 3D models with fluorescence for caries detection in primary teeth. Methods: The study sample will be drawn from eligible participants in a randomized controlled trial at the Royal Children’s Hospital, Melbourne, Australia, where a dental assessment was conducted, including VE using the International Caries Detection and Assessment System (ICDAS) and intraoral scan using the TRIOS 4 (3Shape TRIOS A/S). Participant clinical records will be collected, and all records meeting eligibility criteria will be subject to an on-screen assessment of 3D models by 4 dental practitioners. First, all primary tooth surfaces will be examined for caries based on 3D geometry and color, using a merged ICDAS index. Second, the on-screen assessment of 3D models will include fluorescence, where caries will be classified using a merged ICDAS index that has been modified to incorporate fluorescence criteria. After 4 weeks, all examiners will repeat the on-screen assessment for all 3D models. Finally, an automated caries scoring system will be used to classify caries on primary occlusal surfaces. The agreement in the total number of caries detected per person between methods will be assessed using a Bland-Altman analysis and intraclass correlation coefficients. At a tooth surface level, agreement between methods will be estimated using multilevel models to account for the clustering of dental data. Results: Automated caries scoring of 3D models was completed as of October 2023, with the publication of results expected by July 2024. On-screen assessment has commenced, with the expected completion of scoring and data analysis by March 2024. Results will be disseminated by the end of 2024. Conclusions: The study outcomes may inform new practices that use digital models to facilitate dental assessments. Novel approaches that enable remote dental examination without compromising the accuracy of VE have wide applications in the research environment, clinical practice, and the provision of teledentistry. Trial Registration: Australian New Zealand Clinical Trials Registry ACTRN12622001237774; https://www.anzctr.org.au/Trial/Registration/TrialReview.aspx?id=384632