Christoph Vannahme
Christoph Vannahme has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Bree Jones
Dental Data and Artificial Intelligence (D2AI) Research Group, Melbourne Dental School University of Melbourne Carlton Victoria Australia
5 shared publications - David Burgner
Murdoch Children’s Research Institute, Parkville, Victoria, Australia
5 shared publications - Mihiri Silva
Melbourne Dental School, University of Melbourne, Australia
5 shared publications - Nicky Kilpatrick
Melbourne Dental School, University of Melbourne, 720 Swanston Street, Carlton, 3035, Australia, 61 9341-4000
5 shared publications - Stavroula Michou
Department of Odontology, School of Health and Medical Sciences, University of Copenhagen, Nørre Allé, Denmark
5 shared publications - Tong Chen
Melbourne Dental School, University of Melbourne, 720 Swanston Street, Carlton, 3035, Australia, 61 9341-4000
5 shared publications
Latest Publications
- Open Access
- 8 December 2025
- Published by JMIR Publications Inc. in JMIR Public Health and Surveillance
- Vol. 11, e78023
Dental Caries Detection in Children Using Intraoral Scanners Featuring Fluorescence: Diagnostic Agreement Study
Background: Dental caries is a common chronic disease in children. Digital tools such as intraoral scanners (IOSs) may offer an efficient, scalable alternative to conventional visual examination for dental caries detection. IOSs are handheld devices that generate 3-dimensional (3D) models of the teeth and surrounding structures. Recent advances incorporating fluorescence technology into scanner hardware offer the potential for supporting dental caries detection. However, the performance of digital caries detection methods using 3D models that include both color and fluorescence in children’s teeth remains unknown. Objective: This study aimed to assess the diagnostic agreement between visual examination and on-screen assessment of 3D models generated by an IOS in color and supplemented with fluorescence for caries detection in primary teeth. Methods: Children participating in a clinical trial (n=216, mean age 5.6, SD 0.4 y) underwent visual examination using the International Caries Detection and Assessment System (ICDAS) and intraoral scanning using the TRIOS 4 IOS. Four trained registered dental practitioners independently assessed each participant’s 3D models in color and then supplemented with fluorescence, using a previously validated ICDAS index modified for on-screen assessments of 3D models. All 3D models were assessed again after 4 weeks. The time taken for intraoral scanning and on-screen assessment was recorded. Multilevel logistic regression was used to estimate and compare the likelihood of detecting caries between methods, and Bland-Altman plots were used to visualize agreement. Analyses were performed at the initial (ICDAS ≥ 01), moderate (ICDAS ≥03), and extensive (ICDAS ≥05) dental caries thresholds. Intraclass correlation coefficient (ICC) estimated method agreement and examiner reliability. Results: Of 219 children enrolled, 216 completed dental assessments. A total of 9470 visible primary tooth surfaces were included in the analysis. The average time taken for on-screen assessment of each 3D model (color with fluorescence) was 3.5 (SD 2.3) minutes. The likelihood of detecting caries using color assessment of 3D models was similar to visual examination at all disease thresholds: initial (odds ratio [OR] 1.1, 95% CI 1.0‐1.3), moderate (OR 0.9, 95% CI 0.7‐1.1), and extensive (OR 1.0, 95% CI 0.7‐1.3). When color assessments were supplemented with fluorescence, the likelihood of detecting caries was 30% higher at the initial threshold relative to visual examination (OR 1.3, 95% CI 1.1‐1.5) and similar at the moderate (OR 0.9, 95% CI 0.7‐1.1) and extensive thresholds (OR 0.9, 95% CI 0.7‐1.3). Bland-Altman plots showed a high level of agreement at both moderate and extensive thresholds. Agreement between methods was high (ICC 0.9, 95% CI 0.9‐1.0). Intra- and inter-examiner reliability using intraoral scans ranged from good to excellent (ICC 0.8‐1.0). Conclusions: On-screen assessment of 3D models in color demonstrated the highest agreement with visual examination for caries detection across all disease thresholds.
- 8 December 2025
- Published by JMIR Publications Inc. in JMIR Public Health and Surveillance
- Vol. 11, e78023
Open AccessDental Caries Detection in Children Using Intraoral Scanners Featuring Fluorescence: Diagnostic Agreement Study
Background: Dental caries is a common chronic disease in children. Digital tools such as intraoral scanners (IOSs) may offer an efficient, scalable alternative to conventional visual examination for dental caries detection. IOSs are handheld devices that generate 3-dimensional (3D) models of the teeth and surrounding structures. Recent advances incorporating fluorescence technology into scanner hardware offer the potential for supporting dental caries detection. However, the performance of digital caries detection methods using 3D models that include both color and fluorescence in children’s teeth remains unknown. Objective: This study aimed to assess the diagnostic agreement between visual examination and on-screen assessment of 3D models generated by an IOS in color and supplemented with fluorescence for caries detection in primary teeth. Methods: Children participating in a clinical trial (n=216, mean age 5.6, SD 0.4 y) underwent visual examination using the International Caries Detection and Assessment System (ICDAS) and intraoral scanning using the TRIOS 4 IOS. Four trained registered dental practitioners independently assessed each participant’s 3D models in color and then supplemented with fluorescence, using a previously validated ICDAS index modified for on-screen assessments of 3D models. All 3D models were assessed again after 4 weeks. The time taken for intraoral scanning and on-screen assessment was recorded. Multilevel logistic regression was used to estimate and compare the likelihood of detecting caries between methods, and Bland-Altman plots were used to visualize agreement. Analyses were performed at the initial (ICDAS ≥ 01), moderate (ICDAS ≥03), and extensive (ICDAS ≥05) dental caries thresholds. Intraclass correlation coefficient (ICC) estimated method agreement and examiner reliability. Results: Of 219 children enrolled, 216 completed dental assessments. A total of 9470 visible primary tooth surfaces were included in the analysis. The average time taken for on-screen assessment of each 3D model (color with fluorescence) was 3.5 (SD 2.3) minutes. The likelihood of detecting caries using color assessment of 3D models was similar to visual examination at all disease thresholds: initial (odds ratio [OR] 1.1, 95% CI 1.0‐1.3), moderate (OR 0.9, 95% CI 0.7‐1.1), and extensive (OR 1.0, 95% CI 0.7‐1.3). When color assessments were supplemented with fluorescence, the likelihood of detecting caries was 30% higher at the initial threshold relative to visual examination (OR 1.3, 95% CI 1.1‐1.5) and similar at the moderate (OR 0.9, 95% CI 0.7‐1.1) and extensive thresholds (OR 0.9, 95% CI 0.7‐1.3). Bland-Altman plots showed a high level of agreement at both moderate and extensive thresholds. Agreement between methods was high (ICC 0.9, 95% CI 0.9‐1.0). Intra- and inter-examiner reliability using intraoral scans ranged from good to excellent (ICC 0.8‐1.0). Conclusions: On-screen assessment of 3D models in color demonstrated the highest agreement with visual examination for caries detection across all disease thresholds.
- Top Cited PapersOpen Access
- 15 June 2025
- Published by Elsevier in Journal of Dentistry
- Vol. 160, 105906
Dental caries detection in children using intraoral scans and deep learning
- 15 June 2025
- Published by Elsevier in Journal of Dentistry
- Vol. 160, 105906
Top Cited PapersOpen AccessDental caries detection in children using intraoral scans and deep learning
- Open Access
- 24 May 2025
- Published by JMIR Publications Inc. in JMIR Preprints
Digital Caries Detection in Children using Intraoral Scanners: A Diagnostic Agreement Study (Preprint)
BACKGROUND Dental caries is a common chronic disease in children, yet large-scale surveillance is limited by the resource demands of clinical examinations. Digital tools like intraoral scanners may offer a scalable alternative for caries detection, enabling more efficient data collection for research and population-level oral health monitoring. OBJECTIVE To assess the diagnostic agreement between visual examination and on-screen assessment of 3D models generated by an intraoral scanner (IOS) in colour and supplemented with fluorescence for caries detection in primary teeth. METHODS Children participating in a clinical trial (n=216, mean age 5.6 years) underwent visual examination using the International Caries Detection and Assessment System (ICDAS) and intraoral scanning using the TRIOS 4 IOS (3Shape TRIOS A/S Denmark). Four trained registered dental practitioners independently assessed each participant’s 3D models in colour, then supplemented with fluorescence, using a previously validated ICDAS index modified for on-screen assessments of 3D models. All 3D models were assessed again four weeks later. The time taken for intraoral scanning and on-screen assessment was recorded. Multilevel logistic regression was used to estimate and compare the likelihood of detecting caries between methods, and Bland–Altman plots were used to visualise agreement. Analyses were performed at the initial (ICDAS>01), moderate (ICDAS>03), and extensive (ICDAS>05) dental caries thresholds. Intraclass Correlation Coefficient (ICC) estimated method agreement and examiner reliability. RESULTS 8,209 visible primary tooth coronal surfaces were analysed. The likelihood of detecting caries using colour assessment of 3D models was similar to visual examination at all disease thresholds: initial (odds ratio 1.1, 95% confidence interval (CI) 1.0–1.3), moderate (0.9, 0.7-1.1) and extensive (1.0, 0.7–1.3). When colour assessments were supplemented with fluorescence, the likelihood of detecting caries was 30% higher at the initial threshold relative to visual examination (1.3, 1.1-1.5) and similar at the moderate (0.9, 0.7-1.1) and extensive thresholds (0.9, 0.7-1.3). Bland-Altman plots showed a high level of agreement at both moderate and extensive thresholds. Examiner reliability using intraoral scans ranged from good to excellent. CONCLUSIONS On-screen assessment of 3D models in colour shows greatest agreement with visual examination for caries detection at all disease thresholds. CLINICALTRIAL Australian New Zealand Clinical Trials Registry ACTRN12622001237774 INTERNATIONAL REGISTERED REPORT RR2-10.2196/51578
- 24 May 2025
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessDigital Caries Detection in Children using Intraoral Scanners: A Diagnostic Agreement Study (Preprint)
BACKGROUND Dental caries is a common chronic disease in children, yet large-scale surveillance is limited by the resource demands of clinical examinations. Digital tools like intraoral scanners may offer a scalable alternative for caries detection, enabling more efficient data collection for research and population-level oral health monitoring. OBJECTIVE To assess the diagnostic agreement between visual examination and on-screen assessment of 3D models generated by an intraoral scanner (IOS) in colour and supplemented with fluorescence for caries detection in primary teeth. METHODS Children participating in a clinical trial (n=216, mean age 5.6 years) underwent visual examination using the International Caries Detection and Assessment System (ICDAS) and intraoral scanning using the TRIOS 4 IOS (3Shape TRIOS A/S Denmark). Four trained registered dental practitioners independently assessed each participant’s 3D models in colour, then supplemented with fluorescence, using a previously validated ICDAS index modified for on-screen assessments of 3D models. All 3D models were assessed again four weeks later. The time taken for intraoral scanning and on-screen assessment was recorded. Multilevel logistic regression was used to estimate and compare the likelihood of detecting caries between methods, and Bland–Altman plots were used to visualise agreement. Analyses were performed at the initial (ICDAS>01), moderate (ICDAS>03), and extensive (ICDAS>05) dental caries thresholds. Intraclass Correlation Coefficient (ICC) estimated method agreement and examiner reliability. RESULTS 8,209 visible primary tooth coronal surfaces were analysed. The likelihood of detecting caries using colour assessment of 3D models was similar to visual examination at all disease thresholds: initial (odds ratio 1.1, 95% confidence interval (CI) 1.0–1.3), moderate (0.9, 0.7-1.1) and extensive (1.0, 0.7–1.3). When colour assessments were supplemented with fluorescence, the likelihood of detecting caries was 30% higher at the initial threshold relative to visual examination (1.3, 1.1-1.5) and similar at the moderate (0.9, 0.7-1.1) and extensive thresholds (0.9, 0.7-1.3). Bland-Altman plots showed a high level of agreement at both moderate and extensive thresholds. Examiner reliability using intraoral scans ranged from good to excellent. CONCLUSIONS On-screen assessment of 3D models in colour shows greatest agreement with visual examination for caries detection at all disease thresholds. CLINICALTRIAL Australian New Zealand Clinical Trials Registry ACTRN12622001237774 INTERNATIONAL REGISTERED REPORT RR2-10.2196/51578
- Open Access
- 14 December 2023
- Published by JMIR Publications Inc. in JMIR Research Protocols
- Vol. 12 (1) , e51578
Caries Detection in Primary Teeth Using Intraoral Scanners Featuring Fluorescence: Protocol for a Diagnostic Agreement Study
Background: Digital methods that enable early caries identification can streamline data collection in research and optimize dental examinations for young children. Intraoral scanners are devices used for creating 3D models of teeth in dentistry and are being rapidly adopted into clinical workflows. Integrating fluorescence technology into scanner hardware can support early caries detection. However, the performance of caries detection methods using 3D models featuring color and fluorescence in primary teeth is unknown. Objective: This study aims to assess the diagnostic agreement between visual examination (VE), on-screen assessment of 3D models in approximate natural colors with and without fluorescence, and application of an automated caries scoring system to the 3D models with fluorescence for caries detection in primary teeth. Methods: The study sample will be drawn from eligible participants in a randomized controlled trial at the Royal Children’s Hospital, Melbourne, Australia, where a dental assessment was conducted, including VE using the International Caries Detection and Assessment System (ICDAS) and intraoral scan using the TRIOS 4 (3Shape TRIOS A/S). Participant clinical records will be collected, and all records meeting eligibility criteria will be subject to an on-screen assessment of 3D models by 4 dental practitioners. First, all primary tooth surfaces will be examined for caries based on 3D geometry and color, using a merged ICDAS index. Second, the on-screen assessment of 3D models will include fluorescence, where caries will be classified using a merged ICDAS index that has been modified to incorporate fluorescence criteria. After 4 weeks, all examiners will repeat the on-screen assessment for all 3D models. Finally, an automated caries scoring system will be used to classify caries on primary occlusal surfaces. The agreement in the total number of caries detected per person between methods will be assessed using a Bland-Altman analysis and intraclass correlation coefficients. At a tooth surface level, agreement between methods will be estimated using multilevel models to account for the clustering of dental data. Results: Automated caries scoring of 3D models was completed as of October 2023, with the publication of results expected by July 2024. On-screen assessment has commenced, with the expected completion of scoring and data analysis by March 2024. Results will be disseminated by the end of 2024. Conclusions: The study outcomes may inform new practices that use digital models to facilitate dental assessments. Novel approaches that enable remote dental examination without compromising the accuracy of VE have wide applications in the research environment, clinical practice, and the provision of teledentistry. Trial Registration: Australian New Zealand Clinical Trials Registry ACTRN12622001237774; https://www.anzctr.org.au/Trial/Registration/TrialReview.aspx?id=384632
- 14 December 2023
- Published by JMIR Publications Inc. in JMIR Research Protocols
- Vol. 12 (1) , e51578
Open AccessCaries Detection in Primary Teeth Using Intraoral Scanners Featuring Fluorescence: Protocol for a Diagnostic Agreement Study
Background: Digital methods that enable early caries identification can streamline data collection in research and optimize dental examinations for young children. Intraoral scanners are devices used for creating 3D models of teeth in dentistry and are being rapidly adopted into clinical workflows. Integrating fluorescence technology into scanner hardware can support early caries detection. However, the performance of caries detection methods using 3D models featuring color and fluorescence in primary teeth is unknown. Objective: This study aims to assess the diagnostic agreement between visual examination (VE), on-screen assessment of 3D models in approximate natural colors with and without fluorescence, and application of an automated caries scoring system to the 3D models with fluorescence for caries detection in primary teeth. Methods: The study sample will be drawn from eligible participants in a randomized controlled trial at the Royal Children’s Hospital, Melbourne, Australia, where a dental assessment was conducted, including VE using the International Caries Detection and Assessment System (ICDAS) and intraoral scan using the TRIOS 4 (3Shape TRIOS A/S). Participant clinical records will be collected, and all records meeting eligibility criteria will be subject to an on-screen assessment of 3D models by 4 dental practitioners. First, all primary tooth surfaces will be examined for caries based on 3D geometry and color, using a merged ICDAS index. Second, the on-screen assessment of 3D models will include fluorescence, where caries will be classified using a merged ICDAS index that has been modified to incorporate fluorescence criteria. After 4 weeks, all examiners will repeat the on-screen assessment for all 3D models. Finally, an automated caries scoring system will be used to classify caries on primary occlusal surfaces. The agreement in the total number of caries detected per person between methods will be assessed using a Bland-Altman analysis and intraclass correlation coefficients. At a tooth surface level, agreement between methods will be estimated using multilevel models to account for the clustering of dental data. Results: Automated caries scoring of 3D models was completed as of October 2023, with the publication of results expected by July 2024. On-screen assessment has commenced, with the expected completion of scoring and data analysis by March 2024. Results will be disseminated by the end of 2024. Conclusions: The study outcomes may inform new practices that use digital models to facilitate dental assessments. Novel approaches that enable remote dental examination without compromising the accuracy of VE have wide applications in the research environment, clinical practice, and the provision of teledentistry. Trial Registration: Australian New Zealand Clinical Trials Registry ACTRN12622001237774; https://www.anzctr.org.au/Trial/Registration/TrialReview.aspx?id=384632
- Open Access
- 7 August 2023
- Published by JMIR Publications Inc. in JMIR Preprints
Caries Detection in Primary Teeth Using Intraoral Scanners Featuring Fluorescence: Protocol for a Diagnostic Agreement Study (Preprint)
BACKGROUND Digital methods that enable early caries identification can streamline data collection in research and optimize dental examinations for young children. Intraoral scanners are devices used for creating 3D models of teeth in dentistry and are being rapidly adopted into clinical workflows. Integrating fluorescence technology into scanner hardware can support early caries detection. However, the performance of caries detection methods using 3D models featuring color and fluorescence in primary teeth is unknown. OBJECTIVE This study aims to assess the diagnostic agreement between visual examination (VE), on-screen assessment of 3D models in approximate natural colors with and without fluorescence, and application of an automated caries scoring system to the 3D models with fluorescence for caries detection in primary teeth. METHODS The study sample will be drawn from eligible participants in a randomized controlled trial at the Royal Children’s Hospital, Melbourne, Australia, where a dental assessment was conducted, including VE using the International Caries Detection and Assessment System (ICDAS) and intraoral scan using the TRIOS 4 (3Shape TRIOS A/S). Participant clinical records will be collected, and all records meeting eligibility criteria will be subject to an on-screen assessment of 3D models by 4 dental practitioners. First, all primary tooth surfaces will be examined for caries based on 3D geometry and color, using a merged ICDAS index. Second, the on-screen assessment of 3D models will include fluorescence, where caries will be classified using a merged ICDAS index that has been modified to incorporate fluorescence criteria. After 4 weeks, all examiners will repeat the on-screen assessment for all 3D models. Finally, an automated caries scoring system will be used to classify caries on primary occlusal surfaces. The agreement in the total number of caries detected per person between methods will be assessed using a Bland-Altman analysis and intraclass correlation coefficients. At a tooth surface level, agreement between methods will be estimated using multilevel models to account for the clustering of dental data. RESULTS Automated caries scoring of 3D models was completed as of October 2023, with the publication of results expected by July 2024. On-screen assessment has commenced, with the expected completion of scoring and data analysis by March 2024. Results will be disseminated by the end of 2024. CONCLUSIONS The study outcomes may inform new practices that use digital models to facilitate dental assessments. Novel approaches that enable remote dental examination without compromising the accuracy of VE have wide applications in the research environment, clinical practice, and the provision of teledentistry. CLINICALTRIAL Australian New Zealand Clinical Trials Registry ACTRN12622001237774; https://www.anzctr.org.au/Trial/Registration/TrialReview.aspx?id=384632 INTERNATIONAL REGISTERED REPORT DERR1-10.2196/51578
- 7 August 2023
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessCaries Detection in Primary Teeth Using Intraoral Scanners Featuring Fluorescence: Protocol for a Diagnostic Agreement Study (Preprint)
BACKGROUND Digital methods that enable early caries identification can streamline data collection in research and optimize dental examinations for young children. Intraoral scanners are devices used for creating 3D models of teeth in dentistry and are being rapidly adopted into clinical workflows. Integrating fluorescence technology into scanner hardware can support early caries detection. However, the performance of caries detection methods using 3D models featuring color and fluorescence in primary teeth is unknown. OBJECTIVE This study aims to assess the diagnostic agreement between visual examination (VE), on-screen assessment of 3D models in approximate natural colors with and without fluorescence, and application of an automated caries scoring system to the 3D models with fluorescence for caries detection in primary teeth. METHODS The study sample will be drawn from eligible participants in a randomized controlled trial at the Royal Children’s Hospital, Melbourne, Australia, where a dental assessment was conducted, including VE using the International Caries Detection and Assessment System (ICDAS) and intraoral scan using the TRIOS 4 (3Shape TRIOS A/S). Participant clinical records will be collected, and all records meeting eligibility criteria will be subject to an on-screen assessment of 3D models by 4 dental practitioners. First, all primary tooth surfaces will be examined for caries based on 3D geometry and color, using a merged ICDAS index. Second, the on-screen assessment of 3D models will include fluorescence, where caries will be classified using a merged ICDAS index that has been modified to incorporate fluorescence criteria. After 4 weeks, all examiners will repeat the on-screen assessment for all 3D models. Finally, an automated caries scoring system will be used to classify caries on primary occlusal surfaces. The agreement in the total number of caries detected per person between methods will be assessed using a Bland-Altman analysis and intraclass correlation coefficients. At a tooth surface level, agreement between methods will be estimated using multilevel models to account for the clustering of dental data. RESULTS Automated caries scoring of 3D models was completed as of October 2023, with the publication of results expected by July 2024. On-screen assessment has commenced, with the expected completion of scoring and data analysis by March 2024. Results will be disseminated by the end of 2024. CONCLUSIONS The study outcomes may inform new practices that use digital models to facilitate dental assessments. Novel approaches that enable remote dental examination without compromising the accuracy of VE have wide applications in the research environment, clinical practice, and the provision of teledentistry. CLINICALTRIAL Australian New Zealand Clinical Trials Registry ACTRN12622001237774; https://www.anzctr.org.au/Trial/Registration/TrialReview.aspx?id=384632 INTERNATIONAL REGISTERED REPORT DERR1-10.2196/51578
- 9 November 2016
- Published by SPIE-Intl Soc Optical Eng
- p. 992023-992023-1
Multi-wavelength laser sensor surface for high frame rate imaging refractometry (Conference Presentation)
- 9 November 2016
- Published by SPIE-Intl Soc Optical Eng
- p. 992023-992023-1
Multi-wavelength laser sensor surface for high frame rate imaging refractometry (Conference Presentation)
- Open Access
- 10 April 2015
- Published by Springer Nature in Light: Science & Applications
- Vol. 4 (4) , e269
High frame rate multi-resonance imaging refractometry with distributed feedback dye laser sensor
- 10 April 2015
- Published by Springer Nature in Light: Science & Applications
- Vol. 4 (4) , e269
Open AccessHigh frame rate multi-resonance imaging refractometry with distributed feedback dye laser sensor
- 8 October 2012
- Published by AIP Publishing in Applied Physics Letters
- Vol. 101 (15) , 151123
Emission wavelength of multilayer distributed feedback dye lasers
Precise emission wavelength modeling is essential for understanding and optimization of distributed feedback (DFB) lasers. An analytical approach for determining the emission wavelength based on setting the propagation constant of the Bragg condition and solving for the resulting slab waveguide mode is reported. The method is advantageous to established methods as it predicts the wavelength precisely with reduced complexity. Four-layered hybrid polymer- first order DFB dye lasers with different layer thicknesses are studied. Varying the thickness from 0 nm to 30 nm changes the emission wavelength by 7 nm with compelling agreement of modeling results to experimental measurements.- 8 October 2012
- Published by AIP Publishing in Applied Physics Letters
- Vol. 101 (15) , 151123
Emission wavelength of multilayer distributed feedback dye lasers
Precise emission wavelength modeling is essential for understanding and optimization of distributed feedback (DFB) lasers. An analytical approach for determining the emission wavelength based on setting the propagation constant of the Bragg condition and solving for the resulting slab waveguide mode is reported. The method is advantageous to established methods as it predicts the wavelength precisely with reduced complexity. Four-layered hybrid polymer- first order DFB dye lasers with different layer thicknesses are studied. Varying the thickness from 0 nm to 30 nm changes the emission wavelength by 7 nm with compelling agreement of modeling results to experimental measurements.