KAKazuki Ampuku

Kazuki Ampuku

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kazuki Ampuku has a total of 40 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Fabrication of ultrahigh precision master mandrel toward sub-10 arcsec x-ray Wolter mirror for x-ray telescope

    by Shutaro Mohri, Satoru Egawa, Hiroto Motoyama, Gota Yamaguchi, Jianli Guo, Takehiro Kume, Yusuke Matsuzawa, Hidekazu Takano, Yoshiki Kohmura, Makina Yabashi, et al.

    X-ray telescopes with sub-10-arcsec angular resolution are required for detailed observations of high temperature celestial objects and high-energy phenomena in space. The angular resolution of an x-ray telescope depends on the figure accuracy of focusing optics, such as Wolter mirrors. In this research, a master mandrel was corrected to improve the figure accuracy of a Wolter mirror fabricated from the mandrel by nickel electroforming process. A nozzle-type elastic emission machining system was developed and applied to the figure correction over a limited area of the mandrel (110 mm in the longitudinal direction, 10° in the circumferential direction). The longitudinal figure accuracy of the mandrel was improved from 15–20 nm to ∼3 nm in Root Mean Square (RMS) value. A surface profiler system was developed to evaluate the longitudinal figure accuracy of Wolter mirrors. The measurement repeatability was 0.8 nm (RMS), which is sufficient for the evaluation of the figure accuracy. The figure accuracy of the Wolter mirror in the corrected area was evaluated to be 9.8 nm (RMS), and the slope error was 6.2 μrad (RMS). The imaging performance of a 2° azimuthal range in the corrected area of the Wolter mirror was evaluated by an x-ray focusing experiment at the 1-km beamline of BL29XU at SPring-8. The angular resolution was 4.3 ± 0.3 arcsec in half power diameter, which agreed with the angular resolution evaluated by ray-tracing simulation with the figure profile of the Wolter mirror evaluated by the developed surface profiler system. This agreement demonstrates that the developed surface profiler accurately measures the figure errors that affect the optical performance of the Wolter mirror.

  • Open Access

    Probing the All-sky Distribution of Soft X-Ray Emission Associated with the Milky Way

    by Kazuki Ampuku, Ikuyuki Mitsuishi, Philip Kaaret, Kyoko Matsushita, Kotaro Fukushima, Lorella Angelini, Dimitra Koutroumpa, K. D. Kuntz

    We present an all-sky analysis of soft X-ray emission associated with the Milky Way using HaloSat and ROSAT data, extending our previous study of five Galactic-plane regions to 330 fields across the sky. We performed uniform spectral fitting with a model including an unabsorbed Local Hot Bubble and two additional absorbed thermal components, representing emission from warm–hot and hot plasma, while accounting for solar wind charge exchange and the cosmic X-ray background. The warm–hot component is often interpreted as emission from the circumgalactic medium, whereas the origin of the hot component remains uncertain. Individual-field fits generally favored the inclusion of the hot component and the field-to-field temperature distributions had medians of kT = 0.19 and 0.74 keV, with 16th–84th percentile ranges of 0.17–0.21 and 0.61–0.90 keV, respectively. The corresponding 16th–84th percentile EM ranges were (1.0–8.2) × 10 −2 and (0.5–4.1) × 10 −3 cm −6 pc. Stacked spectra from fields within 60 ∘ ≤ l ≤ 180 ∘ supported the individual-field results. After excluding bright X-ray sources and large-scale Galactic structures, we modeled the EM distributions of 178 fields using a hybrid spatial framework comprising stellar emission and disk-like and halo-like diffuse-plasma components. The warm–hot emission was described mainly by the disk-like term, whereas the hot emission was described mainly by stellar emission with an additional halo-like term. These results support a widespread two-temperature description and suggest a composite origin for the hot emission.

  • Open Access

    Development of Electroformed X-Ray Optics Bridging Synchrotron Radiation Technology and Space Astronomy

    by Ryuto Fujii, Koki Sakuta, Kazuki Ampuku, Yusuke Yoshida, Makoto Yoshihara, Ayumu Takigawa, Keitoku Yoshihira, Tetsuo Kano, Naoki Ishida, Noriyuki Narukage, et al.

    We have developed X-ray telescope mirrors using our original electroforming replication technique, which was established through the fabrication of millimeter-aperture, ultra-short-focal-length nanofocusing mirrors used in synchrotron X-ray microscopy. In this paper, we present for the first time the detailed results of X-ray illumination tests performed both for a 60 mm diameter, full-circumference, double-reflection monolithic electroformed nickel mirror and for the Mirror Module Assembly (MMA) incorporating it. The experiments were performed at SPring-8 beamline BL29XUL, which has a 1 km beamline length. To simulate the parallel X-ray beam from celestial sources, we constructed and utilized a dedicated evaluation system, the High-Brilliance X-ray Kilometer-long Large-Area Expanded-beam Evaluation System (HBX-KLAEES). Thanks to the high photon flux and the virtually point-like source with a very small diverging angle provided by HBX-KLAEES, we were able to evaluate the imaging performance with high fidelity, resolving both the sharp core and the large-angle components of the Point Spread Function. The results demonstrated an extremely sharp core with a Full Width at Half Maximum of 0 . ″ 7 and a Half Power Diameter of 14″ even after integration into the MMA. Furthermore, a positive correlation was found between the angular resolution and the axial direction figure error of both the primary and secondary sections, indicating that the axial figure error contributes to image degradation. Based on these achievements, the MMA incorporating this mirror was selected as one of the hard X-ray optics for the FOXSI-4 sounding rocket experiment, which performs high-resolution soft and hard X-ray imaging spectroscopy of solar flares, and was successfully launched. These results pave the way for further improvements in angular resolution and for the development of high-resolution, ultra-short focal length X-ray optics applicable to small satellites including CubeSats.


  • Open Access

    Development of Electroformed X-ray Optics Bridging Synchrotron Technology and Space Astronomy

    by Ryuto Fujii, Koki Sakuta, Kazuki Ampuku, Yusuke Yoshida, Makoto Yoshihara, Ayumu Takigawa, Keitoku Yoshihira, Tetsuo Kano, Naoki Ishida, Noriyuki Narukage, et al.

    We have developed X-ray telescope mirrors using an original electroforming replication technique established through the fabrication of millimeter-aperture, ultra-short-focal-length nanofocusing mirrors for synchrotron X-ray microscopy. This paper presents detailed results of X-ray illumination tests of a 60-mm-diameter, full-circumference, double-reflection monolithic electroformed nickel mirror and its Mirror Module Assembly (MMA). The experiments were conducted at the 1-km beamline BL29XUL at SPring-8. To simulate a parallel X-ray beam from celestial sources, we constructed a dedicated evaluation system, the High-Brilliance X-ray Kilometer-long Large-Area Expanded-beam Evaluation System (HBX-KLAEES). Owing to the high photon flux and the quasi-point-like source with a small divergence provided by HBX-KLAEES, the imaging performance was evaluated with high fidelity, resolving both the sharp core and large-angle components of the Point Spread Function (PSF). The results show an extremely sharp core with a Full Width at Half Maximum (FWHM) of 0.7 arcsec and a Half Power Diameter (HPD) of 14 arcsec, even after integration into the MMA. In addition, a positive correlation was found between angular resolution and axial figure error in both the primary and secondary mirror sections, indicating that axial figure errors contribute to image degradation. Based on these results, the MMA was selected as one of the hard X-ray optics for the FOXSI-4 sounding rocket experiment, which performs high-resolution soft and hard X-ray imaging spectroscopy of solar flares and was successfully launched. These results demonstrate the potential for further improvements in angular resolution and the development of high-resolution, ultra-short focal length X-ray optics for small satellites, including CubeSats.

  • Open Access

    Soft X-Ray Energy Spectra in the Wide-field Galactic Disk Area Revealed with HaloSat

    by Kazuki Ampuku, Ikuyuki Mitsuishi, Koki Sakuta, Philip Kaaret, Daniel M. LaRocca, Lorella Angelini

    We analyzed data from HaloSat observations for five fields in the Galactic disk located far away from the Galactic center (135° < l < 254°) to understand the nature of soft X-ray energy emission in the Galactic disk. The fields have 14° diameter and were selected to contain no significant high-flux X-ray sources. All five HaloSat soft X-ray energy spectra (0.4–7 keV with energy resolution of < 100 eV below 1 keV) show a possibility of the presence of unresolved high-temperature plasma in the Galactic disk (UHTPGD) with a temperature of 0.8–1.0 keV and an emission measure of (8–11) × 10−4 cm−6 pc in addition to the soft X-ray diffuse background components mainly studied at higher Galactic latitudes (solar wind charge exchange emission, Local Hot Bubble, Milky Way halo emission, and the cosmic X-ray background). This suggests that the UHTPGD is present across the whole Galactic disk. We also observed UHTPGD emission in a region with no bright sources in an XMM-Newton field contained within one of the HaloSat fields. The temperature and emission measure are consistent with those measured with HaloSat. Moreover, the stacked spectra of the X-ray pointlike sources and near-infrared-identified point sources such as stars in the XMM-Newton field also show a spectral feature similar to the UHTPGD emission. This suggests that the UHTPGD may partly originate from pointlike sources such as stars.


  • Open Access

    Efficient and precise fabrication of Wolter type-I x-ray mirrors via nickel electroforming replication using quartz glass mandrels

    by Gota Yamaguchi, Yusuke Matsuzawa, Takehiro Kume, Yoichi Imamura, Hiroaki Miyashita, Akinari Ito, Koki Sakuta, Kazuki Ampuku, Ryuto Fujii, Kentaro Hiraguri, et al.

    This study presents an approach for fabricating Wolter type-I mirrors for x-ray telescopes using a nickel electroforming replication process with quartz glass mandrels. The proposed method addresses the challenges encountered in conventional fabrication techniques, which involve using electroless nickel-coated aluminum mandrels that are susceptible to corrosion and thermal deformation. Quartz glass mandrels offer excellent chemical, thermal, and mechanical stability, enabling the efficient production of high-performance mirrors. Wolter type-I mirrors for telescopes possess a large aperture that collects x-ray photons from the universe. However, previous nickel electroforming replication processes using quartz glass mandrels have challenges in fabricating large mirrors, particularly due to bubble pit formation during nickel shell development. In this study, we introduced an efficient pitting inhibition technique via vacuum degassing. This technique facilitates the precise replication of pit-free Wolter type-I mirrors for telescopes using quartz glass mandrels. We demonstrated the fabrication process on a Wolter type-I mirror proposed for FOXSI-4 [(FOXSI) Focusing Optics X-ray Solar Imager], resulting in three mirrors obtained from the same mandrel without repolishing or repairing. The figure error of the mirror was within 1 µm over most areas in both longitudinal and circumferential directions. The ray-tracing simulation indicated that the performance of the mirror was ∼12 arcsec in half-power diameter, comparable to the performance achieved by previous high-resolution x-ray missions.