Ryuto Fujii
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ryuto Fujii has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Gota Yamaguchi
Riken SPring-8 Center, Sayo-cho, Japan
4 shared publications - Hidekazu Mimura
The University of Tokyo
4 shared publications - Ikuyuki Mitsuishi
Nagoya University
4 shared publications - Kazuki Ampuku
Graduate School of Science, Nagoya University 5 , Nagoya, Aichi 464-8602
4 shared publications - Koki Sakuta
Graduate School of Science, Nagoya University 5 , Nagoya, Aichi 464-8602
4 shared publications - Yusuke Matsuzawa
Technology Center, Natsume Optical Corporation 4 , Iida, Nagano 399-2413
4 shared publications
Latest Publications
- 1 November 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (11)
Fabrication of ultrahigh precision master mandrel toward sub-10 arcsec x-ray Wolter mirror for x-ray telescope
X-ray telescopes with sub-10-arcsec angular resolution are required for detailed observations of high temperature celestial objects and high-energy phenomena in space. The angular resolution of an x-ray telescope depends on the figure accuracy of focusing optics, such as Wolter mirrors. In this research, a master mandrel was corrected to improve the figure accuracy of a Wolter mirror fabricated from the mandrel by nickel electroforming process. A nozzle-type elastic emission machining system was developed and applied to the figure correction over a limited area of the mandrel (110 mm in the longitudinal direction, 10° in the circumferential direction). The longitudinal figure accuracy of the mandrel was improved from 15–20 nm to ∼3 nm in Root Mean Square (RMS) value. A surface profiler system was developed to evaluate the longitudinal figure accuracy of Wolter mirrors. The measurement repeatability was 0.8 nm (RMS), which is sufficient for the evaluation of the figure accuracy. The figure accuracy of the Wolter mirror in the corrected area was evaluated to be 9.8 nm (RMS), and the slope error was 6.2 μrad (RMS). The imaging performance of a 2° azimuthal range in the corrected area of the Wolter mirror was evaluated by an x-ray focusing experiment at the 1-km beamline of BL29XU at SPring-8. The angular resolution was 4.3 ± 0.3 arcsec in half power diameter, which agreed with the angular resolution evaluated by ray-tracing simulation with the figure profile of the Wolter mirror evaluated by the developed surface profiler system. This agreement demonstrates that the developed surface profiler accurately measures the figure errors that affect the optical performance of the Wolter mirror.
- 1 November 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (11)
Fabrication of ultrahigh precision master mandrel toward sub-10 arcsec x-ray Wolter mirror for x-ray telescope
X-ray telescopes with sub-10-arcsec angular resolution are required for detailed observations of high temperature celestial objects and high-energy phenomena in space. The angular resolution of an x-ray telescope depends on the figure accuracy of focusing optics, such as Wolter mirrors. In this research, a master mandrel was corrected to improve the figure accuracy of a Wolter mirror fabricated from the mandrel by nickel electroforming process. A nozzle-type elastic emission machining system was developed and applied to the figure correction over a limited area of the mandrel (110 mm in the longitudinal direction, 10° in the circumferential direction). The longitudinal figure accuracy of the mandrel was improved from 15–20 nm to ∼3 nm in Root Mean Square (RMS) value. A surface profiler system was developed to evaluate the longitudinal figure accuracy of Wolter mirrors. The measurement repeatability was 0.8 nm (RMS), which is sufficient for the evaluation of the figure accuracy. The figure accuracy of the Wolter mirror in the corrected area was evaluated to be 9.8 nm (RMS), and the slope error was 6.2 μrad (RMS). The imaging performance of a 2° azimuthal range in the corrected area of the Wolter mirror was evaluated by an x-ray focusing experiment at the 1-km beamline of BL29XU at SPring-8. The angular resolution was 4.3 ± 0.3 arcsec in half power diameter, which agreed with the angular resolution evaluated by ray-tracing simulation with the figure profile of the Wolter mirror evaluated by the developed surface profiler system. This agreement demonstrates that the developed surface profiler accurately measures the figure errors that affect the optical performance of the Wolter mirror.
- Open Access
- 1 April 2026
- Published by IOP Publishing in Publications of the Astronomical Society of the Pacific
- Vol. 138 (4) , 045003
Development of Electroformed X-Ray Optics Bridging Synchrotron Radiation Technology and Space Astronomy
We have developed X-ray telescope mirrors using our original electroforming replication technique, which was established through the fabrication of millimeter-aperture, ultra-short-focal-length nanofocusing mirrors used in synchrotron X-ray microscopy. In this paper, we present for the first time the detailed results of X-ray illumination tests performed both for a 60 mm diameter, full-circumference, double-reflection monolithic electroformed nickel mirror and for the Mirror Module Assembly (MMA) incorporating it. The experiments were performed at SPring-8 beamline BL29XUL, which has a 1 km beamline length. To simulate the parallel X-ray beam from celestial sources, we constructed and utilized a dedicated evaluation system, the High-Brilliance X-ray Kilometer-long Large-Area Expanded-beam Evaluation System (HBX-KLAEES). Thanks to the high photon flux and the virtually point-like source with a very small diverging angle provided by HBX-KLAEES, we were able to evaluate the imaging performance with high fidelity, resolving both the sharp core and the large-angle components of the Point Spread Function. The results demonstrated an extremely sharp core with a Full Width at Half Maximum of 0 . ″ 7 and a Half Power Diameter of 14″ even after integration into the MMA. Furthermore, a positive correlation was found between the angular resolution and the axial direction figure error of both the primary and secondary sections, indicating that the axial figure error contributes to image degradation. Based on these achievements, the MMA incorporating this mirror was selected as one of the hard X-ray optics for the FOXSI-4 sounding rocket experiment, which performs high-resolution soft and hard X-ray imaging spectroscopy of solar flares, and was successfully launched. These results pave the way for further improvements in angular resolution and for the development of high-resolution, ultra-short focal length X-ray optics applicable to small satellites including CubeSats.
- 1 April 2026
- Published by IOP Publishing in Publications of the Astronomical Society of the Pacific
- Vol. 138 (4) , 045003
Open AccessDevelopment of Electroformed X-Ray Optics Bridging Synchrotron Radiation Technology and Space Astronomy
We have developed X-ray telescope mirrors using our original electroforming replication technique, which was established through the fabrication of millimeter-aperture, ultra-short-focal-length nanofocusing mirrors used in synchrotron X-ray microscopy. In this paper, we present for the first time the detailed results of X-ray illumination tests performed both for a 60 mm diameter, full-circumference, double-reflection monolithic electroformed nickel mirror and for the Mirror Module Assembly (MMA) incorporating it. The experiments were performed at SPring-8 beamline BL29XUL, which has a 1 km beamline length. To simulate the parallel X-ray beam from celestial sources, we constructed and utilized a dedicated evaluation system, the High-Brilliance X-ray Kilometer-long Large-Area Expanded-beam Evaluation System (HBX-KLAEES). Thanks to the high photon flux and the virtually point-like source with a very small diverging angle provided by HBX-KLAEES, we were able to evaluate the imaging performance with high fidelity, resolving both the sharp core and the large-angle components of the Point Spread Function. The results demonstrated an extremely sharp core with a Full Width at Half Maximum of 0 . ″ 7 and a Half Power Diameter of 14″ even after integration into the MMA. Furthermore, a positive correlation was found between the angular resolution and the axial direction figure error of both the primary and secondary sections, indicating that the axial figure error contributes to image degradation. Based on these achievements, the MMA incorporating this mirror was selected as one of the hard X-ray optics for the FOXSI-4 sounding rocket experiment, which performs high-resolution soft and hard X-ray imaging spectroscopy of solar flares, and was successfully launched. These results pave the way for further improvements in angular resolution and for the development of high-resolution, ultra-short focal length X-ray optics applicable to small satellites including CubeSats.
- Open Access
Development of Electroformed X-ray Optics Bridging Synchrotron Technology and Space Astronomy
We have developed X-ray telescope mirrors using an original electroforming replication technique established through the fabrication of millimeter-aperture, ultra-short-focal-length nanofocusing mirrors for synchrotron X-ray microscopy. This paper presents detailed results of X-ray illumination tests of a 60-mm-diameter, full-circumference, double-reflection monolithic electroformed nickel mirror and its Mirror Module Assembly (MMA). The experiments were conducted at the 1-km beamline BL29XUL at SPring-8. To simulate a parallel X-ray beam from celestial sources, we constructed a dedicated evaluation system, the High-Brilliance X-ray Kilometer-long Large-Area Expanded-beam Evaluation System (HBX-KLAEES). Owing to the high photon flux and the quasi-point-like source with a small divergence provided by HBX-KLAEES, the imaging performance was evaluated with high fidelity, resolving both the sharp core and large-angle components of the Point Spread Function (PSF). The results show an extremely sharp core with a Full Width at Half Maximum (FWHM) of 0.7 arcsec and a Half Power Diameter (HPD) of 14 arcsec, even after integration into the MMA. In addition, a positive correlation was found between angular resolution and axial figure error in both the primary and secondary mirror sections, indicating that axial figure errors contribute to image degradation. Based on these results, the MMA was selected as one of the hard X-ray optics for the FOXSI-4 sounding rocket experiment, which performs high-resolution soft and hard X-ray imaging spectroscopy of solar flares and was successfully launched. These results demonstrate the potential for further improvements in angular resolution and the development of high-resolution, ultra-short focal length X-ray optics for small satellites, including CubeSats.
Open AccessDevelopment of Electroformed X-ray Optics Bridging Synchrotron Technology and Space Astronomy
We have developed X-ray telescope mirrors using an original electroforming replication technique established through the fabrication of millimeter-aperture, ultra-short-focal-length nanofocusing mirrors for synchrotron X-ray microscopy. This paper presents detailed results of X-ray illumination tests of a 60-mm-diameter, full-circumference, double-reflection monolithic electroformed nickel mirror and its Mirror Module Assembly (MMA). The experiments were conducted at the 1-km beamline BL29XUL at SPring-8. To simulate a parallel X-ray beam from celestial sources, we constructed a dedicated evaluation system, the High-Brilliance X-ray Kilometer-long Large-Area Expanded-beam Evaluation System (HBX-KLAEES). Owing to the high photon flux and the quasi-point-like source with a small divergence provided by HBX-KLAEES, the imaging performance was evaluated with high fidelity, resolving both the sharp core and large-angle components of the Point Spread Function (PSF). The results show an extremely sharp core with a Full Width at Half Maximum (FWHM) of 0.7 arcsec and a Half Power Diameter (HPD) of 14 arcsec, even after integration into the MMA. In addition, a positive correlation was found between angular resolution and axial figure error in both the primary and secondary mirror sections, indicating that axial figure errors contribute to image degradation. Based on these results, the MMA was selected as one of the hard X-ray optics for the FOXSI-4 sounding rocket experiment, which performs high-resolution soft and hard X-ray imaging spectroscopy of solar flares and was successfully launched. These results demonstrate the potential for further improvements in angular resolution and the development of high-resolution, ultra-short focal length X-ray optics for small satellites, including CubeSats.
- Open Access
- 1 December 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (12)
Efficient and precise fabrication of Wolter type-I x-ray mirrors via nickel electroforming replication using quartz glass mandrels
This study presents an approach for fabricating Wolter type-I mirrors for x-ray telescopes using a nickel electroforming replication process with quartz glass mandrels. The proposed method addresses the challenges encountered in conventional fabrication techniques, which involve using electroless nickel-coated aluminum mandrels that are susceptible to corrosion and thermal deformation. Quartz glass mandrels offer excellent chemical, thermal, and mechanical stability, enabling the efficient production of high-performance mirrors. Wolter type-I mirrors for telescopes possess a large aperture that collects x-ray photons from the universe. However, previous nickel electroforming replication processes using quartz glass mandrels have challenges in fabricating large mirrors, particularly due to bubble pit formation during nickel shell development. In this study, we introduced an efficient pitting inhibition technique via vacuum degassing. This technique facilitates the precise replication of pit-free Wolter type-I mirrors for telescopes using quartz glass mandrels. We demonstrated the fabrication process on a Wolter type-I mirror proposed for FOXSI-4 [(FOXSI) Focusing Optics X-ray Solar Imager], resulting in three mirrors obtained from the same mandrel without repolishing or repairing. The figure error of the mirror was within 1 µm over most areas in both longitudinal and circumferential directions. The ray-tracing simulation indicated that the performance of the mirror was ∼12 arcsec in half-power diameter, comparable to the performance achieved by previous high-resolution x-ray missions.
- 1 December 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (12)
Open AccessEfficient and precise fabrication of Wolter type-I x-ray mirrors via nickel electroforming replication using quartz glass mandrels
This study presents an approach for fabricating Wolter type-I mirrors for x-ray telescopes using a nickel electroforming replication process with quartz glass mandrels. The proposed method addresses the challenges encountered in conventional fabrication techniques, which involve using electroless nickel-coated aluminum mandrels that are susceptible to corrosion and thermal deformation. Quartz glass mandrels offer excellent chemical, thermal, and mechanical stability, enabling the efficient production of high-performance mirrors. Wolter type-I mirrors for telescopes possess a large aperture that collects x-ray photons from the universe. However, previous nickel electroforming replication processes using quartz glass mandrels have challenges in fabricating large mirrors, particularly due to bubble pit formation during nickel shell development. In this study, we introduced an efficient pitting inhibition technique via vacuum degassing. This technique facilitates the precise replication of pit-free Wolter type-I mirrors for telescopes using quartz glass mandrels. We demonstrated the fabrication process on a Wolter type-I mirror proposed for FOXSI-4 [(FOXSI) Focusing Optics X-ray Solar Imager], resulting in three mirrors obtained from the same mandrel without repolishing or repairing. The figure error of the mirror was within 1 µm over most areas in both longitudinal and circumferential directions. The ray-tracing simulation indicated that the performance of the mirror was ∼12 arcsec in half-power diameter, comparable to the performance achieved by previous high-resolution x-ray missions.
- 1 January 1990
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 198 (1) , 176-179
New doors opened by the polar patrol balloon-cosmic quark matter, micrograins and gamma rays
Balloon experiments in Antarctica make possible to observe continuously the astrophysical objects in the southern polar sky during the flight of more than 20 days. New fields and instrument for the polar balloon experiment are proposed.
- 1 January 1990
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 198 (1) , 176-179
New doors opened by the polar patrol balloon-cosmic quark matter, micrograins and gamma rays
Balloon experiments in Antarctica make possible to observe continuously the astrophysical objects in the southern polar sky during the flight of more than 20 days. New fields and instrument for the polar balloon experiment are proposed.