Sungwon Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sungwon Kim has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Chang Hoon Oh
Department of Radiology and Center for Imaging Sciences, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
2 shared publications - Sang Lim Choi
Department of Radiology, Chung-Ang University Gwangmyeong Hospital, Gwangmyeong 14353, Republic of Korea
2 shared publications - Hyeyoung Kwon
Department of Radiology, Chungnam University Hospital, School of Medicine, Chungnam University, Daejeon 35015, Republic of Korea
1 shared publication - Soo Buem Cho
Department of Radiology, Ewha Womans University Seoul Hospital, College of Medicine, Ewha Womans University, Seoul, Republic of Korea
1 shared publication - Yebin Kim
Department of Radiology, Ewha Womans University Mokdong Hospital, College of Medicine, Ewha Womans University, Seoul 07985, Republic of Korea
1 shared publication
Latest Publications
- Open Access
Temporary Ureter Occlusion with Simultaneous Urinary Diversion via a Single-Access Route Using a 4-French Balloon Catheter and a Pigtail Nephrostomy Drainage Catheter
Background and Objectives: This study evaluated the efficacy and safety of temporary ureteral occlusion combined with urinary diversion using a single-access route created by inserting a balloon catheter through a pigtail nephrostomy drainage catheter. With this approach, we aimed to offer an alternative for patients with ureteral leaks who are suboptimal surgical candidates. Materials and Methods: This retrospective study included nine patients (eight of which were bilateral cases and one was unilateral, totaling seventeen cases) who underwent the surgery between September 2023 and March 2024. The method involved gaining percutaneous access to the pelvicalyceal system, inserting a 4-French Fogarty balloon catheter through a pigtail nephrostomy catheter, and inflating the balloon at the proximal or mid-ureter. Results: All 17 cases achieved technical successful with no major complications. The procedure effectively relieved symptoms associated with urinary leakage in most patients. However, the significant deflation of the balloon catheter occurred in five cases (29.4%), with three (17.6%) experiencing complete deflation. In these five cases, the final balloon size was 5.81 mm (range: 0–8.9 mm), confirming a 25.0% decrease in size from pre- to post-procedure. Ureteral occlusion was 28.3 d long on average (range: 8–57 d). All patients experienced symptom relief during temporary ureteral occlusion. Except for two patients lost to follow-up, three patients showed symptom improvement with only PCN and four patients underwent surgical closure of the fistula tract before or after balloon catheter removal. Conclusions: This study confirms that this approach is safe and effective.
Open AccessTemporary Ureter Occlusion with Simultaneous Urinary Diversion via a Single-Access Route Using a 4-French Balloon Catheter and a Pigtail Nephrostomy Drainage Catheter
Background and Objectives: This study evaluated the efficacy and safety of temporary ureteral occlusion combined with urinary diversion using a single-access route created by inserting a balloon catheter through a pigtail nephrostomy drainage catheter. With this approach, we aimed to offer an alternative for patients with ureteral leaks who are suboptimal surgical candidates. Materials and Methods: This retrospective study included nine patients (eight of which were bilateral cases and one was unilateral, totaling seventeen cases) who underwent the surgery between September 2023 and March 2024. The method involved gaining percutaneous access to the pelvicalyceal system, inserting a 4-French Fogarty balloon catheter through a pigtail nephrostomy catheter, and inflating the balloon at the proximal or mid-ureter. Results: All 17 cases achieved technical successful with no major complications. The procedure effectively relieved symptoms associated with urinary leakage in most patients. However, the significant deflation of the balloon catheter occurred in five cases (29.4%), with three (17.6%) experiencing complete deflation. In these five cases, the final balloon size was 5.81 mm (range: 0–8.9 mm), confirming a 25.0% decrease in size from pre- to post-procedure. Ureteral occlusion was 28.3 d long on average (range: 8–57 d). All patients experienced symptom relief during temporary ureteral occlusion. Except for two patients lost to follow-up, three patients showed symptom improvement with only PCN and four patients underwent surgical closure of the fistula tract before or after balloon catheter removal. Conclusions: This study confirms that this approach is safe and effective.
- Open Access
- 16 December 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (24) , 7721
Percutaneous Ureteral Stent Insertion in Patients with Benign Uretero-Ileal Anastomosis Strictures Who Underwent Radical Cystectomy: Assessing Risk Factors for Stent Patency
We aimed to investigate the risk factors of early double-J ureteral stent (DJUS) dysfunction rates and the long-term patency of DJUSs inserted via a percutaneous approach in patients with benign uretero-ileal anastomosis stricture (UIAS) who had undergone radical cystectomy. In this retrospective study, 63 DJUS placements were placed via a percutaneous nephrostomy tract in 42 consecutive patients between May 2020 and March 2023. The technical success rate was 100% in all patients without major complications. The early dysfunction rate and long-term patency rate were 38.1% (24/63) and 84.2% (32/38), respectively. The blood clot retention grade, balloon dilatation, and length of the ureteral stricture exhibited a significant correlation with early DJUS dysfunction (blood clot retention grade: odds ratio (OR) 6.922 in grade two, p = 0.009; balloon dilatation: OR 0.186, p = 0.017; length of ureteral stricture: OR 8.715, p = 0.035 in moderate stenosis, and 7.646, p = 0.028 in severe stenosis). A multivariate Cox’s proportional hazard analysis revealed that blood clot retention grade and length of ureteral stricture were independent predictors of long-term DJUS patency. Percutaneous insertion of the DJUSs was safe and effective in patients with benign UIAS.
- 16 December 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (24) , 7721
Open AccessPercutaneous Ureteral Stent Insertion in Patients with Benign Uretero-Ileal Anastomosis Strictures Who Underwent Radical Cystectomy: Assessing Risk Factors for Stent Patency
We aimed to investigate the risk factors of early double-J ureteral stent (DJUS) dysfunction rates and the long-term patency of DJUSs inserted via a percutaneous approach in patients with benign uretero-ileal anastomosis stricture (UIAS) who had undergone radical cystectomy. In this retrospective study, 63 DJUS placements were placed via a percutaneous nephrostomy tract in 42 consecutive patients between May 2020 and March 2023. The technical success rate was 100% in all patients without major complications. The early dysfunction rate and long-term patency rate were 38.1% (24/63) and 84.2% (32/38), respectively. The blood clot retention grade, balloon dilatation, and length of the ureteral stricture exhibited a significant correlation with early DJUS dysfunction (blood clot retention grade: odds ratio (OR) 6.922 in grade two, p = 0.009; balloon dilatation: OR 0.186, p = 0.017; length of ureteral stricture: OR 8.715, p = 0.035 in moderate stenosis, and 7.646, p = 0.028 in severe stenosis). A multivariate Cox’s proportional hazard analysis revealed that blood clot retention grade and length of ureteral stricture were independent predictors of long-term DJUS patency. Percutaneous insertion of the DJUSs was safe and effective in patients with benign UIAS.