Ashwin Ramanathan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Ashwin Ramanathan has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Faezeh Marzbanrad
Monash University
3 shared publications - Kenneth Tan
Department of Paediatrics; Monash University; Melbourne Australia
3 shared publications Arrabella King
Monash Newborn, Monash Childrens Hospital and Department of Paediatrics, Monash University, Melbourne, Clayton, VIC, Australia
2 shared publications- Atul Malhotra
Monash Newborn, Monash Children’s Hospital, Melbourne, Australia
2 shared publications - Ethan Grooby
Department of Electrical and Computer Systems Engineering, Monash University, Melbourne, Clayton, VIC, Australia
2 shared publications - Lindsay Zhou
Department of Paediatrics Monash University Melbourne Australia
2 shared publications
Latest Publications
- Open Access
- 15 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Engineering in Medicine and Biology
- Vol. 5, 345-352
NeoSSNet: Real-Time Neonatal Chest Sound Separation Using Deep Learning
Goal: Auscultation for neonates is a simple and non-invasive method of diagnosing cardiovascular and respiratory disease. However, obtaining high-quality chest sounds containing only heart or lung sounds is non-trivial. Hence, this study introduces a new deep-learning model named NeoSSNet and evaluates its performance in neonatal chest sound separation with previous methods. Methods: We propose a masked-based architecture similar to Conv-TasNet. The encoder and decoder consist of 1D convolution and 1D transposed convolution, while the mask generator consists of a convolution and transformer architecture. The input chest sounds were first encoded as a sequence of tokens using 1D convolution. The tokens were then passed to the mask generator to generate two masks, one for heart sounds and one for lung sounds. Each mask is then applied to the input token sequence. Lastly, the tokens are converted back to waveforms using 1D transposed convolution. Results: Our proposed model showed superior results compared to the previous methods based on objective distortion measures, ranging from a 2.01 dB improvement to a 5.06 dB improvement. The proposed model is also significantly faster than the previous methods, with at least a 17-time improvement. Conclusions: The proposed model could be a suitable preprocessing step for any health monitoring system where only the heart sound or lung sound is desired.
- 15 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Engineering in Medicine and Biology
- Vol. 5, 345-352
Open AccessNeoSSNet: Real-Time Neonatal Chest Sound Separation Using Deep Learning
Goal: Auscultation for neonates is a simple and non-invasive method of diagnosing cardiovascular and respiratory disease. However, obtaining high-quality chest sounds containing only heart or lung sounds is non-trivial. Hence, this study introduces a new deep-learning model named NeoSSNet and evaluates its performance in neonatal chest sound separation with previous methods. Methods: We propose a masked-based architecture similar to Conv-TasNet. The encoder and decoder consist of 1D convolution and 1D transposed convolution, while the mask generator consists of a convolution and transformer architecture. The input chest sounds were first encoded as a sequence of tokens using 1D convolution. The tokens were then passed to the mask generator to generate two masks, one for heart sounds and one for lung sounds. Each mask is then applied to the input token sequence. Lastly, the tokens are converted back to waveforms using 1D transposed convolution. Results: Our proposed model showed superior results compared to the previous methods based on objective distortion measures, ranging from a 2.01 dB improvement to a 5.06 dB improvement. The proposed model is also significantly faster than the previous methods, with at least a 17-time improvement. Conclusions: The proposed model could be a suitable preprocessing step for any health monitoring system where only the heart sound or lung sound is desired.
- 14 December 2023
- Published by Wolters Kluwer Health in The Pediatric Infectious Disease Journal
- Vol. 43 (4) , e139-e141
Head-to-Head Comparison Between Respiratory Syncytial Virus and Human Metapneumovirus Bronchiolitis in the Setting of Increased Viral Testing
We compared the epidemiology, severity and management of hospitalized respiratory syncytial virus (n = 305) and human metapneumovirus (n = 39) bronchiolitis in a setting with high respiratory virus testing (95% of admissions tested). Respiratory syncytial virus-positive infants were younger and tended to require more hydration support and longer hospital stays compared to human metapneumovirus-positive infants. Respiratory support requirements were similar between groups despite significant age differences.
- 14 December 2023
- Published by Wolters Kluwer Health in The Pediatric Infectious Disease Journal
- Vol. 43 (4) , e139-e141
Head-to-Head Comparison Between Respiratory Syncytial Virus and Human Metapneumovirus Bronchiolitis in the Setting of Increased Viral Testing
We compared the epidemiology, severity and management of hospitalized respiratory syncytial virus (n = 305) and human metapneumovirus (n = 39) bronchiolitis in a setting with high respiratory virus testing (95% of admissions tested). Respiratory syncytial virus-positive infants were younger and tended to require more hydration support and longer hospital stays compared to human metapneumovirus-positive infants. Respiratory support requirements were similar between groups despite significant age differences.
- Open Access
Prediction of Neonatal Respiratory Distress in Term Babies at Birth from Digital Stethoscope Recorded Chest Sounds
Neonatal respiratory distress is a common condition that if left untreated, can lead to short- and long-term complications. This paper investigates the usage of digital stethoscope recorded chest sounds taken within 1min post-delivery, to enable early detection and prediction of neonatal respiratory distress. Fifty-one term newborns were included in this study, 9 of whom developed respiratory distress. For each newborn, 1min anterior and posterior recordings were taken. These recordings were pre-processed to remove noisy segments and obtain high-quality heart and lung sounds. The random undersampling boosting (RUSBoost) classifier was then trained on a variety of features, such as power and vital sign features extracted from the heart and lung sounds. The RUSBoost algorithm produced specificity, sensitivity, and accuracy results of 85.0%, 66.7% and 81.8%, respectively.
Open AccessPrediction of Neonatal Respiratory Distress in Term Babies at Birth from Digital Stethoscope Recorded Chest Sounds
Neonatal respiratory distress is a common condition that if left untreated, can lead to short- and long-term complications. This paper investigates the usage of digital stethoscope recorded chest sounds taken within 1min post-delivery, to enable early detection and prediction of neonatal respiratory distress. Fifty-one term newborns were included in this study, 9 of whom developed respiratory distress. For each newborn, 1min anterior and posterior recordings were taken. These recordings were pre-processed to remove noisy segments and obtain high-quality heart and lung sounds. The random undersampling boosting (RUSBoost) classifier was then trained on a variety of features, such as power and vital sign features extracted from the heart and lung sounds. The RUSBoost algorithm produced specificity, sensitivity, and accuracy results of 85.0%, 66.7% and 81.8%, respectively.
- 6 January 2020
- Published by Springer Nature in European Journal of Pediatrics
- Vol. 179 (5) , 781-789
Assessment of breath sounds at birth using digital stethoscope technology
Newborn transition is a phase of complex change involving lung fluid clearance and lung aeration. We aimed to use a digital stethoscope (DS) to assess the change in breath sound characteristics over the first 2 h of life and its relationship to mode of delivery. A commercially available DS was used to record breath sounds of term newborns at 1-min and 2-h post-delivery via normal vaginal delivery (NVD) or elective caesarean section (CS). Sound analysis was conducted, and two comparisons were carried out: change in frequency profiles over 2 h, and effect of delivery mode. There was a significant drop in the frequency profile of breath sounds from 1 min to 2 h with mean (SD) frequency decreasing from 333.74 (35.42) to 302.71 (47.19) Hz, p < 0.001, and proportion of power (SD) in the lowest frequency band increasing from 0.27 (0.11) to 0.37 (0.15), p < 0.001. At 1 min, NVD infants had slightly higher frequency than CS but no difference at 2 h. Conclusion: We were able to use DS technology in the transitioning infant to depict significant changes to breath sound characteristics over the first 2 h of life, reflecting the process of lung aeration. What is Known: • Lung fluid clearance and lung aeration are critical processes that facilitate respiration and mode of delivery can impact this • Digital stethoscopes offer enhanced auscultation and have been used in the paediatric population for the assessment of pulmonary and cardiac sounds What is New: • This is the first study to use digital stethoscope technology to assess breath sounds at birth • We describe a change in breath sound characteristics over the first 2 h of life and suggest a predictive utility of this analysis to predict the development of respiratory distress in newborns prior to the onset of symptoms
- 6 January 2020
- Published by Springer Nature in European Journal of Pediatrics
- Vol. 179 (5) , 781-789
Assessment of breath sounds at birth using digital stethoscope technology
Newborn transition is a phase of complex change involving lung fluid clearance and lung aeration. We aimed to use a digital stethoscope (DS) to assess the change in breath sound characteristics over the first 2 h of life and its relationship to mode of delivery. A commercially available DS was used to record breath sounds of term newborns at 1-min and 2-h post-delivery via normal vaginal delivery (NVD) or elective caesarean section (CS). Sound analysis was conducted, and two comparisons were carried out: change in frequency profiles over 2 h, and effect of delivery mode. There was a significant drop in the frequency profile of breath sounds from 1 min to 2 h with mean (SD) frequency decreasing from 333.74 (35.42) to 302.71 (47.19) Hz, p < 0.001, and proportion of power (SD) in the lowest frequency band increasing from 0.27 (0.11) to 0.37 (0.15), p < 0.001. At 1 min, NVD infants had slightly higher frequency than CS but no difference at 2 h. Conclusion: We were able to use DS technology in the transitioning infant to depict significant changes to breath sound characteristics over the first 2 h of life, reflecting the process of lung aeration. What is Known: • Lung fluid clearance and lung aeration are critical processes that facilitate respiration and mode of delivery can impact this • Digital stethoscopes offer enhanced auscultation and have been used in the paediatric population for the assessment of pulmonary and cardiac sounds What is New: • This is the first study to use digital stethoscope technology to assess breath sounds at birth • We describe a change in breath sound characteristics over the first 2 h of life and suggest a predictive utility of this analysis to predict the development of respiratory distress in newborns prior to the onset of symptoms