Mahendra Bhadu
Research Subjects
Mahendra Bhadu has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Ajay Sharma
1 shared publication- Amit Arora
Advanced Materials Processing Research Group, Materials Engineering, Indian Institute of Technology Gandhinagar, Gandhinagar, India
1 shared publication - Amit Arora
Electrical Engineering Department, Engineering College Bikaner, Rajasthan, India
1 shared publication - Amit Sharma
Government Engineering College Bikaner
1 shared publication - Arvind Kumar
Department of Electrical Engineering, Engineering College Bikaner, Rajasthan, India
1 shared publication - Chandra Shekhar Rajoria
Government Engineering College Bikaner
1 shared publication
Latest Publications
- Open Access
- 28 June 2024
- Published by Universidad Nacional Autonoma de Mexico in Journal of Applied Research and Technology
- Vol. 22 (3) , 362-379
Improvement of an AC microgrid system’s stability by using a fuzzy logic-based PSS controller
This research article presents the low-frequency oscillation damping control of an AC Microgrid. It is integrated with four distributed generation units in which two DGs are renewable energy source based solar PV and wind energy using DFIG and the other two DGs are conventional synchronous generator-based hydro and diesel generators. There is insufficient generation through renewable-based DG then a diesel generator is employed as an emergency unit to fulfil the requirements and maintain and control the deviation of the frequency of the system. The use of renewable-based DG affected the system's dynamic stability and the characteristics of an integrated microgrid differ from conventional sources of generation. This investigation explores the impression of the deployment of multiple forms of the power oscillation damping (POD) controllers to distributed generation sources of grid forming AC Microgrid. The main various types of POD controllers are conventional lead-lag PSSs, MBPSS-4B, and proposed robust fuzzy logic PSS (FLPSS) controllers are implemented on distributed generation units of AC Microgrid for the elimination of low-frequency oscillation. Low oscillation frequencies between 0.1 and 2 Hz are the focus of this work. The system's damping ratios and stability margins because of MG integration are observed using eigenvalues analysis. The results of the simulation test demonstrate the accomplishment of the robust fuzzy logic PSS controller regarding conventional lead-lag PSSs and the MBPSS-4B controller during circumstances of fault.
- 28 June 2024
- Published by Universidad Nacional Autonoma de Mexico in Journal of Applied Research and Technology
- Vol. 22 (3) , 362-379
Open AccessImprovement of an AC microgrid system’s stability by using a fuzzy logic-based PSS controller
This research article presents the low-frequency oscillation damping control of an AC Microgrid. It is integrated with four distributed generation units in which two DGs are renewable energy source based solar PV and wind energy using DFIG and the other two DGs are conventional synchronous generator-based hydro and diesel generators. There is insufficient generation through renewable-based DG then a diesel generator is employed as an emergency unit to fulfil the requirements and maintain and control the deviation of the frequency of the system. The use of renewable-based DG affected the system's dynamic stability and the characteristics of an integrated microgrid differ from conventional sources of generation. This investigation explores the impression of the deployment of multiple forms of the power oscillation damping (POD) controllers to distributed generation sources of grid forming AC Microgrid. The main various types of POD controllers are conventional lead-lag PSSs, MBPSS-4B, and proposed robust fuzzy logic PSS (FLPSS) controllers are implemented on distributed generation units of AC Microgrid for the elimination of low-frequency oscillation. Low oscillation frequencies between 0.1 and 2 Hz are the focus of this work. The system's damping ratios and stability margins because of MG integration are observed using eigenvalues analysis. The results of the simulation test demonstrate the accomplishment of the robust fuzzy logic PSS controller regarding conventional lead-lag PSSs and the MBPSS-4B controller during circumstances of fault.
- Open Access
- 13 May 2024
- Published by Hindawi Limited in Journal of Electrical and Computer Engineering
- Vol. 2024, 1-9
Heart Signal Analysis Using Multistage Classification Denoising Model
Cardiovascular disease is a major cause of death worldwide, and the COVID-19 pandemic has only made the situation worse. The purpose of this work is to explore various time-frequency analysis methods that can be used to classify heart sound signals and identify multiple abnormalities in the heart, such as aortic stenosis, mitral stenosis, and mitral valve prolapse. The signal has been modified using three techniques—tunable quality wavelet transform (TQWT), discrete wavelet transform (DWT), and empirical mode decomposition—to detect heart signal abnormality. The proposed model detects heart signal abnormality at two stages, the user end and the clinical end. At the user end, binary classification of signals is performed, and if signals are abnormal then further classification is done at the clinic. The approach starts with signal preprocessing and uses the discrete wavelet transform (DWT) coefficients to train the hybrid model, which consists of one long short-term memory (LSTM) network layer and three convolutional neural network (CNN) layers. This method produced comparable results, with a classification accuracy for signals, through the utilization of the CNN and LSTM model. Combining the CNN’s skill in feature extraction with the LSTM’s capacity to record time-dependent features improves the efficacy of the model. Identifying issues early and initiating appropriate medication can alleviate the burden associated with heart valve diseases.
- 13 May 2024
- Published by Hindawi Limited in Journal of Electrical and Computer Engineering
- Vol. 2024, 1-9
Open AccessHeart Signal Analysis Using Multistage Classification Denoising Model
Cardiovascular disease is a major cause of death worldwide, and the COVID-19 pandemic has only made the situation worse. The purpose of this work is to explore various time-frequency analysis methods that can be used to classify heart sound signals and identify multiple abnormalities in the heart, such as aortic stenosis, mitral stenosis, and mitral valve prolapse. The signal has been modified using three techniques—tunable quality wavelet transform (TQWT), discrete wavelet transform (DWT), and empirical mode decomposition—to detect heart signal abnormality. The proposed model detects heart signal abnormality at two stages, the user end and the clinical end. At the user end, binary classification of signals is performed, and if signals are abnormal then further classification is done at the clinic. The approach starts with signal preprocessing and uses the discrete wavelet transform (DWT) coefficients to train the hybrid model, which consists of one long short-term memory (LSTM) network layer and three convolutional neural network (CNN) layers. This method produced comparable results, with a classification accuracy for signals, through the utilization of the CNN and LSTM model. Combining the CNN’s skill in feature extraction with the LSTM’s capacity to record time-dependent features improves the efficacy of the model. Identifying issues early and initiating appropriate medication can alleviate the burden associated with heart valve diseases.
- Open Access
- 1 February 2024
- Published by Wiley in Journal of Electrical and Computer Engineering
- Vol. 2024, 1-21
N − 1 Security Criteria Based Integrated Deterministic and Probabilistic Framework for Composite Power System Reliability
Unpredictable variations in load demand and unanticipated component failures are progressively impacting the operation of modern power systems, making system evaluation more stochastic in nature. Although deterministic approaches were formerly the norm for determining system status, probabilistic approaches have greatly improved the capacity to capture the stochastic behavior characteristic of power system operations. The presented work in the paper recommends the use of probabilistic modelling approaches with deterministic approaches, highlighting their crucial function in augmenting the reliability and security of contemporary power systems to unanticipated failures. In this paper, N1 security criteria based reliability of the composite power system (CPS) is proposed using an integrated deterministic and probabilistic framework (D-P) considering outage of the transmission line. For the deterministic approach (DA), line overloading on available lines is determined using the static security index (SSI). For the probabilistic approach (PA), reliability indices such as expected loss of power (ELOP), expected frequency of contingency (EFOC), expected loss of load (ELOL), probability of load curtailment (PLC), and expected duration of load curtailments (EDLC) are calculated. Further, for each contingency, a performance index is determined using both approaches to assess the severity of the contingency that occurred on the power system. Based on the N1 security criteria based reliability analysis using an integrated D-P framework, a credible critical set of transmission lines is obtained, which can serve as important information to system operators. The proposed techniques have been tested on IEEE 24 bus reliability test system (RTS).
- 1 February 2024
- Published by Wiley in Journal of Electrical and Computer Engineering
- Vol. 2024, 1-21
Open AccessN − 1 Security Criteria Based Integrated Deterministic and Probabilistic Framework for Composite Power System Reliability
Unpredictable variations in load demand and unanticipated component failures are progressively impacting the operation of modern power systems, making system evaluation more stochastic in nature. Although deterministic approaches were formerly the norm for determining system status, probabilistic approaches have greatly improved the capacity to capture the stochastic behavior characteristic of power system operations. The presented work in the paper recommends the use of probabilistic modelling approaches with deterministic approaches, highlighting their crucial function in augmenting the reliability and security of contemporary power systems to unanticipated failures. In this paper, N1 security criteria based reliability of the composite power system (CPS) is proposed using an integrated deterministic and probabilistic framework (D-P) considering outage of the transmission line. For the deterministic approach (DA), line overloading on available lines is determined using the static security index (SSI). For the probabilistic approach (PA), reliability indices such as expected loss of power (ELOP), expected frequency of contingency (EFOC), expected loss of load (ELOL), probability of load curtailment (PLC), and expected duration of load curtailments (EDLC) are calculated. Further, for each contingency, a performance index is determined using both approaches to assess the severity of the contingency that occurred on the power system. Based on the N1 security criteria based reliability analysis using an integrated D-P framework, a credible critical set of transmission lines is obtained, which can serve as important information to system operators. The proposed techniques have been tested on IEEE 24 bus reliability test system (RTS).
- 29 January 2024
- Published by Springer Nature in Electrical Engineering
- Vol. 106 (4) , 4339-4370
Hydro-thermal scheduling under RE uncertainties using an improved cheetah optimization
- 29 January 2024
- Published by Springer Nature in Electrical Engineering
- Vol. 106 (4) , 4339-4370
Hydro-thermal scheduling under RE uncertainties using an improved cheetah optimization
- Open Access
- 1 January 2024
- Published by Wiley in International Journal of Energy Research
- Vol. 2024 (1)
Numerical Simulation of Heat Transfer Characteristics for Optimum Air Flow Rate in Triangular PV/T System
The aim of this numerical study is to investigate the heat transfer characteristics of the air flowing in the triangular photovoltaic thermal (PV/T) array/system at variable velocities. The PV/T array in the present analysis is composed of seven photovoltaic (PV) panels connected in series along with a triangular duct throughout its length. The heat transfer analysis in the PV panel (solid component) and visualization of temperature distribution in the PV/T system has been simulated by the use of system coupling of steady state thermal and CFX tools in ANSYS 18.2. Experiment was initially performed at velocity of 1.5 m/s inside the duct by the use of ANSYS software to predict the glass temperature, outlet air temperature, and tedlar temperature of triangular PV/T system. Further, the velocity has been incremented by 1 m/s up to 6.5 m/s to see the overall performance of the system. The validation of simulation results showed a good agreement with the experimental results under reasonable limit. The gain in temperature with the increase in velocity becomes marginal (only 7%) after 4.5 m/s. The temperature contours from the numerical simulation also revealed that cooling up to the last panel is not significant beyond 4.5 m/s. Similar tendency is documented in the overall exergy efficiency which significantly increased to 4.5 m/s and became marginal with further increment in velocity. It can be inferred that the optimum velocity which can fulfill the requirement of cooling of all PV panels along with reasonable thermal output is 4.5 m/s. The thermal energy gain gradually increases as the day progresses and becomes maximum at 2:00 PM. The average thermal energy gain being 9.6% higher than that in the morning (10:00 AM) indicates its suitability for applications requiring moderately high temperature. The present numerical investigation focuses on improving the overall performance of the system without the involvement of any additional cost. The system can be used in various applications like crop drying, space heating, etc. Owing to different outlet air temperatures during the day, the applications can either be utilized independently or can be combined to be used at different times according to the temperature requirement.
- 1 January 2024
- Published by Wiley in International Journal of Energy Research
- Vol. 2024 (1)
Open AccessNumerical Simulation of Heat Transfer Characteristics for Optimum Air Flow Rate in Triangular PV/T System
The aim of this numerical study is to investigate the heat transfer characteristics of the air flowing in the triangular photovoltaic thermal (PV/T) array/system at variable velocities. The PV/T array in the present analysis is composed of seven photovoltaic (PV) panels connected in series along with a triangular duct throughout its length. The heat transfer analysis in the PV panel (solid component) and visualization of temperature distribution in the PV/T system has been simulated by the use of system coupling of steady state thermal and CFX tools in ANSYS 18.2. Experiment was initially performed at velocity of 1.5 m/s inside the duct by the use of ANSYS software to predict the glass temperature, outlet air temperature, and tedlar temperature of triangular PV/T system. Further, the velocity has been incremented by 1 m/s up to 6.5 m/s to see the overall performance of the system. The validation of simulation results showed a good agreement with the experimental results under reasonable limit. The gain in temperature with the increase in velocity becomes marginal (only 7%) after 4.5 m/s. The temperature contours from the numerical simulation also revealed that cooling up to the last panel is not significant beyond 4.5 m/s. Similar tendency is documented in the overall exergy efficiency which significantly increased to 4.5 m/s and became marginal with further increment in velocity. It can be inferred that the optimum velocity which can fulfill the requirement of cooling of all PV panels along with reasonable thermal output is 4.5 m/s. The thermal energy gain gradually increases as the day progresses and becomes maximum at 2:00 PM. The average thermal energy gain being 9.6% higher than that in the morning (10:00 AM) indicates its suitability for applications requiring moderately high temperature. The present numerical investigation focuses on improving the overall performance of the system without the involvement of any additional cost. The system can be used in various applications like crop drying, space heating, etc. Owing to different outlet air temperatures during the day, the applications can either be utilized independently or can be combined to be used at different times according to the temperature requirement.
- Open Access
- 1 January 2024
- Published by Wiley in Journal of Electrical and Computer Engineering
- Vol. 2024 (1)
Wind Farm Layout Optimization Problem Using Nature‐Inspired Algorithms
The wind farm layout optimization problem (WFLOP) is a significant problem in the field of renewable energy. In this development of wind farm, solving the WFLOP is a crucial task, which entails placing the turbines in the wind farm in the best locations to reduce wake effects and enhance predicted power generation. In recent decades, the WFLOP problem has been solved mathematically. Meanwhile, the growing load demand led to an increase in the complexity of WFLOP. The results obtained by mathematical methods were not accurate enough to suit complexity of WFLOP. Nowadays, researchers from a variety of fields are developing nature‐inspired algorithms (NIAs) to solve difficult real‐world problems. This study is an attempt to review the most important innovations in the field of NIAs to solve the WFLOP problem. The classification of the reviewed literature is based on different applied approaches and models. In addition to specific proposals, the advantages and disadvantages of certain domains are also discussed. This study provides a future direction to the fellow researchers who are working in the field of WFLOP.
- 1 January 2024
- Published by Wiley in Journal of Electrical and Computer Engineering
- Vol. 2024 (1)
Open AccessWind Farm Layout Optimization Problem Using Nature‐Inspired Algorithms
The wind farm layout optimization problem (WFLOP) is a significant problem in the field of renewable energy. In this development of wind farm, solving the WFLOP is a crucial task, which entails placing the turbines in the wind farm in the best locations to reduce wake effects and enhance predicted power generation. In recent decades, the WFLOP problem has been solved mathematically. Meanwhile, the growing load demand led to an increase in the complexity of WFLOP. The results obtained by mathematical methods were not accurate enough to suit complexity of WFLOP. Nowadays, researchers from a variety of fields are developing nature‐inspired algorithms (NIAs) to solve difficult real‐world problems. This study is an attempt to review the most important innovations in the field of NIAs to solve the WFLOP problem. The classification of the reviewed literature is based on different applied approaches and models. In addition to specific proposals, the advantages and disadvantages of certain domains are also discussed. This study provides a future direction to the fellow researchers who are working in the field of WFLOP.
- Open Access
- 16 December 2023
- Published by Wiley in Journal of Electrical and Computer Engineering
- Vol. 2023, 1-18
Thermal Modeling of Photovoltaic Panel for Cell Temperature and Power Output Predictions under Outdoor Climatic Conditions of Jodhpur
The rise in the temperature severely affects photovoltaic cell efficiency and hence its power output. Moreover, it also causes the development of thermal stresses that may reduce their life span. Thus, there is a need for an accurate estimation of the cell’s working temperature. In this paper, a detailed thermal model based on various heat transfer modes involved and their governing equations has been presented to estimate the cell temperature of a PV module using MATLAB software under different climatic and solar insolation conditions. In order to validate the presented model, an experimental setup has been built and operated under actual outdoor conditions of Jodhpur, a city in the Thar Desert of Rajasthan. For the peak summer month of June, the predicted glass cover outer surface temperature has been found to be within 0.2–4.5°C of experimentally measured values and the back sheet temperature is found to be within 0.5–5.5°C. The predicted and measured power outputs have been found to be within 0.85–1.2 W while the efficiency values are within 0.17–0.38%. For the early summer month of April, the variations are 0.13–4.1°C, 0.2–4.1°C, 0.44–1.65 W, and 0.1–0.5% for glass cover temperature, back sheet temperature, power output, and efficiency, respectively. Thus, the predictions of the developed thermal model have exhibited a good agreement with the experimental results. The maximum glass cover temperatures recorded were 60°C and 65.5°C when the ambient temperatures were 35°C and 42°C near the noon for the early summer and peak summer day experiments, respectively. The presented model can be used to generate a year-round cell temperature data for the known environmental data of a location, which can help in the selection or development of appropriate cooling technology at the planning stage of the installation of a solar PV plant.
- 16 December 2023
- Published by Wiley in Journal of Electrical and Computer Engineering
- Vol. 2023, 1-18
Open AccessThermal Modeling of Photovoltaic Panel for Cell Temperature and Power Output Predictions under Outdoor Climatic Conditions of Jodhpur
The rise in the temperature severely affects photovoltaic cell efficiency and hence its power output. Moreover, it also causes the development of thermal stresses that may reduce their life span. Thus, there is a need for an accurate estimation of the cell’s working temperature. In this paper, a detailed thermal model based on various heat transfer modes involved and their governing equations has been presented to estimate the cell temperature of a PV module using MATLAB software under different climatic and solar insolation conditions. In order to validate the presented model, an experimental setup has been built and operated under actual outdoor conditions of Jodhpur, a city in the Thar Desert of Rajasthan. For the peak summer month of June, the predicted glass cover outer surface temperature has been found to be within 0.2–4.5°C of experimentally measured values and the back sheet temperature is found to be within 0.5–5.5°C. The predicted and measured power outputs have been found to be within 0.85–1.2 W while the efficiency values are within 0.17–0.38%. For the early summer month of April, the variations are 0.13–4.1°C, 0.2–4.1°C, 0.44–1.65 W, and 0.1–0.5% for glass cover temperature, back sheet temperature, power output, and efficiency, respectively. Thus, the predictions of the developed thermal model have exhibited a good agreement with the experimental results. The maximum glass cover temperatures recorded were 60°C and 65.5°C when the ambient temperatures were 35°C and 42°C near the noon for the early summer and peak summer day experiments, respectively. The presented model can be used to generate a year-round cell temperature data for the known environmental data of a location, which can help in the selection or development of appropriate cooling technology at the planning stage of the installation of a solar PV plant.
- 8 June 2022
- Published by Taylor & Francis in IETE Journal of Research
- Vol. 69 (12) , 9016-9039
Coordinated Wide-Area Damping Control in Modern Power Systems Embedded with Utility-Scale Wind-Solar Plants
This paper presents a coordinated wide-area damping control of power system stabilizers (PSSs), static synchronous compensator (STATCOM), and static synchronous series compensator (SSSC) for grid-forming based wind and solar PV generation resources. The main objective of this work is to enhance the damping for inter-area oscillations while maintaining the voltage and frequency in the prescribed range, taking into consideration the operational uncertainties. Better voltage and reactive power support are provided by the use of STATCOM and for additional damping, an SSSC is employed with the coordinated wide-area damping controller (CWADC). Variable-speed wind turbine control methodology strategically combined with inertia control, de-loading control, pitch angle control, and electronic rotor speed control is employed to obtain an optimum response for discontinuous generation mixes and variable wind speed. The geometric measures of controllability/observability and residues method have been utilized to choose the appropriate input control signals and optimal location of CWADC. A multi-objective salp swarm algorithm has been used to optimize the parameters of the proposed CWADC. To demonstrate the efficacy of the proposed CWADC, nonlinear time-domain simulations are performed on a modified IEEE 68-bus test system embedded with hybrid wind-solar power plants considered multiple time delays.
- 8 June 2022
- Published by Taylor & Francis in IETE Journal of Research
- Vol. 69 (12) , 9016-9039
Coordinated Wide-Area Damping Control in Modern Power Systems Embedded with Utility-Scale Wind-Solar Plants
This paper presents a coordinated wide-area damping control of power system stabilizers (PSSs), static synchronous compensator (STATCOM), and static synchronous series compensator (SSSC) for grid-forming based wind and solar PV generation resources. The main objective of this work is to enhance the damping for inter-area oscillations while maintaining the voltage and frequency in the prescribed range, taking into consideration the operational uncertainties. Better voltage and reactive power support are provided by the use of STATCOM and for additional damping, an SSSC is employed with the coordinated wide-area damping controller (CWADC). Variable-speed wind turbine control methodology strategically combined with inertia control, de-loading control, pitch angle control, and electronic rotor speed control is employed to obtain an optimum response for discontinuous generation mixes and variable wind speed. The geometric measures of controllability/observability and residues method have been utilized to choose the appropriate input control signals and optimal location of CWADC. A multi-objective salp swarm algorithm has been used to optimize the parameters of the proposed CWADC. To demonstrate the efficacy of the proposed CWADC, nonlinear time-domain simulations are performed on a modified IEEE 68-bus test system embedded with hybrid wind-solar power plants considered multiple time delays.
- Open Access
- 20 August 2021
- Published by Elsevier in Journal of Engineering Research
Recommendations of Optimal Sampling Rates for Periodic Output Feedback Based Discrete Mode PSS
In this paper, an attempt is made to recommend the optimal sampling time period for Periodic Output Feedback (POF) based discrete mode power system stabilizer (DPSS). Various collection of input and output sampling time interval has been used in the designing of POF based DPSS. The Particle Swarm Optimization (PSO) technique is used to obtain the optimal gain matrix of the POF controller as well as the optimal sampling time intervals. The effectiveness of POF based DPSS over continuous mode lead-lag PSS is certified using small-signal stability studies. The parameters of lead-lag type continuous mode PSS is also tuned using the PSO technique. The PSS is designed using POF technique for single machine infinite bus (SMIB) system, considering a variety of sampling time intervals at input-output port. Finally, a trial is made to propose an optimum input and output sampling time period for SMIB test power system, through simulation studies.
- 20 August 2021
- Published by Elsevier in Journal of Engineering Research
Open AccessRecommendations of Optimal Sampling Rates for Periodic Output Feedback Based Discrete Mode PSS
In this paper, an attempt is made to recommend the optimal sampling time period for Periodic Output Feedback (POF) based discrete mode power system stabilizer (DPSS). Various collection of input and output sampling time interval has been used in the designing of POF based DPSS. The Particle Swarm Optimization (PSO) technique is used to obtain the optimal gain matrix of the POF controller as well as the optimal sampling time intervals. The effectiveness of POF based DPSS over continuous mode lead-lag PSS is certified using small-signal stability studies. The parameters of lead-lag type continuous mode PSS is also tuned using the PSO technique. The PSS is designed using POF technique for single machine infinite bus (SMIB) system, considering a variety of sampling time intervals at input-output port. Finally, a trial is made to propose an optimum input and output sampling time period for SMIB test power system, through simulation studies.