Amit Sharma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Amit Sharma has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Chandra Shekhar Rajoria
Government Engineering College Bikaner
4 shared publications - Dharmendra Singh
Engineering College Bikaner Department of Mechanical Engineering
3 shared publications - Ravi Kumar
National Institute of Technology Patna
2 shared publications J. P. Bhamu
Department of Mechanical Engineering, Government Engineering College Bikaner, India
1 shared publication- Mahendra Bhadu
Electrical Engineering Department, Engineering College Bikaner, Rajasthan, India
1 shared publication - Manoj Kumar Gaur
Madhav Institute of Technology & Science
1 shared publication
Latest Publications
- 1 October 2025
- Published by Springer Nature
- p. 135-145
Energy and Exergy Performance of an Opaque Photovoltaic (PV/T) Air Collector Under Different Weather Conditions of Rajasthan (INDIA)
- 1 October 2025
- Published by Springer Nature
- p. 135-145
Energy and Exergy Performance of an Opaque Photovoltaic (PV/T) Air Collector Under Different Weather Conditions of Rajasthan (INDIA)
- 19 April 2024
- Published by Springer Nature
- p. 201-214
Analysis of Thin Layer Mathematical Modelling for Mint Leaves Using Solar Photovoltaic/Thermal (PV/T) System
- 19 April 2024
- Published by Springer Nature
- p. 201-214
Analysis of Thin Layer Mathematical Modelling for Mint Leaves Using Solar Photovoltaic/Thermal (PV/T) System
- Open Access
- 1 January 2024
- Published by Wiley in International Journal of Energy Research
- Vol. 2024 (1)
Numerical Simulation of Heat Transfer Characteristics for Optimum Air Flow Rate in Triangular PV/T System
The aim of this numerical study is to investigate the heat transfer characteristics of the air flowing in the triangular photovoltaic thermal (PV/T) array/system at variable velocities. The PV/T array in the present analysis is composed of seven photovoltaic (PV) panels connected in series along with a triangular duct throughout its length. The heat transfer analysis in the PV panel (solid component) and visualization of temperature distribution in the PV/T system has been simulated by the use of system coupling of steady state thermal and CFX tools in ANSYS 18.2. Experiment was initially performed at velocity of 1.5 m/s inside the duct by the use of ANSYS software to predict the glass temperature, outlet air temperature, and tedlar temperature of triangular PV/T system. Further, the velocity has been incremented by 1 m/s up to 6.5 m/s to see the overall performance of the system. The validation of simulation results showed a good agreement with the experimental results under reasonable limit. The gain in temperature with the increase in velocity becomes marginal (only 7%) after 4.5 m/s. The temperature contours from the numerical simulation also revealed that cooling up to the last panel is not significant beyond 4.5 m/s. Similar tendency is documented in the overall exergy efficiency which significantly increased to 4.5 m/s and became marginal with further increment in velocity. It can be inferred that the optimum velocity which can fulfill the requirement of cooling of all PV panels along with reasonable thermal output is 4.5 m/s. The thermal energy gain gradually increases as the day progresses and becomes maximum at 2:00 PM. The average thermal energy gain being 9.6% higher than that in the morning (10:00 AM) indicates its suitability for applications requiring moderately high temperature. The present numerical investigation focuses on improving the overall performance of the system without the involvement of any additional cost. The system can be used in various applications like crop drying, space heating, etc. Owing to different outlet air temperatures during the day, the applications can either be utilized independently or can be combined to be used at different times according to the temperature requirement.
- 1 January 2024
- Published by Wiley in International Journal of Energy Research
- Vol. 2024 (1)
Open AccessNumerical Simulation of Heat Transfer Characteristics for Optimum Air Flow Rate in Triangular PV/T System
The aim of this numerical study is to investigate the heat transfer characteristics of the air flowing in the triangular photovoltaic thermal (PV/T) array/system at variable velocities. The PV/T array in the present analysis is composed of seven photovoltaic (PV) panels connected in series along with a triangular duct throughout its length. The heat transfer analysis in the PV panel (solid component) and visualization of temperature distribution in the PV/T system has been simulated by the use of system coupling of steady state thermal and CFX tools in ANSYS 18.2. Experiment was initially performed at velocity of 1.5 m/s inside the duct by the use of ANSYS software to predict the glass temperature, outlet air temperature, and tedlar temperature of triangular PV/T system. Further, the velocity has been incremented by 1 m/s up to 6.5 m/s to see the overall performance of the system. The validation of simulation results showed a good agreement with the experimental results under reasonable limit. The gain in temperature with the increase in velocity becomes marginal (only 7%) after 4.5 m/s. The temperature contours from the numerical simulation also revealed that cooling up to the last panel is not significant beyond 4.5 m/s. Similar tendency is documented in the overall exergy efficiency which significantly increased to 4.5 m/s and became marginal with further increment in velocity. It can be inferred that the optimum velocity which can fulfill the requirement of cooling of all PV panels along with reasonable thermal output is 4.5 m/s. The thermal energy gain gradually increases as the day progresses and becomes maximum at 2:00 PM. The average thermal energy gain being 9.6% higher than that in the morning (10:00 AM) indicates its suitability for applications requiring moderately high temperature. The present numerical investigation focuses on improving the overall performance of the system without the involvement of any additional cost. The system can be used in various applications like crop drying, space heating, etc. Owing to different outlet air temperatures during the day, the applications can either be utilized independently or can be combined to be used at different times according to the temperature requirement.
- 18 November 2021
- Published by Yildiz Technical University in Journal of Thermal Engineering
- Vol. 7 (7) , 1591-1603
Numerical simulation of heat transfer characteristics of taper helical and spiral tube heat exchanger
The paper investigates the heat transfer characteristics of the heat exchanger under two different configurations namely taper helical tube and spiral tube type heat exchanger. The working fluid is water which flows in tubes kept horizontally and the mass flow rate ranges from 0.04 kg/s to 0.16 kg/s. The effect of tube configuration parameters and Reynolds number on heat transfer coefficient and Nusselt number were studied. Regression equations have been developed for both the configurations under horizontal orientation using various process parameters and regression tools available in Minitab Software. A comparison has been made between the theoretical results and the results obtained from simulation gives an error of 15% which is well within the permissible limit. The result indicates that the highest value of Nusselt number is greater by 21% than taper helical tube heat exchanger which is attributed to better heat transfer characteristics of spiral tube heat exchanger and hence the former is thermally superior over the latter. In this study, temperature and velocity contour have been developed for both the configurations which clearly indicates that, when heat transfer is considered, spiral configuration should be preferred over taper helical configuration.
- 18 November 2021
- Published by Yildiz Technical University in Journal of Thermal Engineering
- Vol. 7 (7) , 1591-1603
Numerical simulation of heat transfer characteristics of taper helical and spiral tube heat exchanger
The paper investigates the heat transfer characteristics of the heat exchanger under two different configurations namely taper helical tube and spiral tube type heat exchanger. The working fluid is water which flows in tubes kept horizontally and the mass flow rate ranges from 0.04 kg/s to 0.16 kg/s. The effect of tube configuration parameters and Reynolds number on heat transfer coefficient and Nusselt number were studied. Regression equations have been developed for both the configurations under horizontal orientation using various process parameters and regression tools available in Minitab Software. A comparison has been made between the theoretical results and the results obtained from simulation gives an error of 15% which is well within the permissible limit. The result indicates that the highest value of Nusselt number is greater by 21% than taper helical tube heat exchanger which is attributed to better heat transfer characteristics of spiral tube heat exchanger and hence the former is thermally superior over the latter. In this study, temperature and velocity contour have been developed for both the configurations which clearly indicates that, when heat transfer is considered, spiral configuration should be preferred over taper helical configuration.